Loading...
HomeMy WebLinkAbout_Conformed Set Volume 1 116NUP12358910111213141516171819206.18.1MNPQORSTQ.1Q.6R.3C3A-3001C5A-3002A5A-3101A2A-3101C1A-3100A1A-3100B0063MechanicalB0070Elev P.0B0001Egress Stair WB0002Egress Stair N20.2B0042South CorridorExhibitionB52Teams Pod Design AreaB0023WomenB0022MenB40Emerson Manufacturing Teaching LabB34TelecomB36Staff OfficeEXISTINGAREAWAYSTO REMAINA-5100B6A6A-5100D6D3B23Teams Pod Design AreaSHB01ShaftB38CAD/CAM LabB0040West CorridorB01West VestibuleB40AStaff OfficeB56Teams Pod Build AreaA4A-3002C3A-3004B50Student Orgs. Office2A-3110A-5270A1A-5270C1A-7001AA3B22Rapid Prototyping LabB0064ElecB0065ElecB40BStorage-13'-0"B0061CustodialB32Projects StorageEXISTINGEGRESS STAIRNEW MONUMENTALSTAIR9D9D9DFIXEDCASEWORKFIXED CASEWORKB39VendingEXISTING LOUVERS TO REMAINB01AB01BB22BB0002AB0002BB0022B50B0064B0065AB0063B40CB34B32B36AB40AB40BB52B56B0001BGLAZED OPENINGA-5200A2A-5201C2MATCHLINESEE/1A-2100B10"2' - 8" 3' - 10" 5' - 4" 4' - 0" 2' - 8" 2' - 8" 5' - 4" 4' - 8" 3' - 4" 4' - 0" 5' - 4" 4' - 0" 2' - 8" 4' - 0" 5' - 4" 4' - 0" 2' - 8" 4' - 0"4' - 0" 3' - 0"1' - 9"2' - 9"2' - 4"1' - 0 5/8"6' - 0"1' - 7"3' - 10 1/2"3' - 10"9' - 4"5' - 4"4' - 0"5' - 4"4' - 0"2' - 8"1' - 0"3' - 1"A-5201A2R.520.3R.4A-5202AA3A-7100A5A-7003A2A-7002A2A-5321A11' - 5 3/4"4' - 6 1/4"5' - 4"5' - 4"5' - 4"2' - 8"5' - 4"2' - 8"2' - 8"UPUPB02Team ConferenceB04Team ConferenceB10Teams Pod Design AreaB06Swanson DirectorB14Teams Pod Build AreaB18Teams Pod Build AreaB15Teams Pod Design AreaB19Teams Pod Design AreaB35ElecB30Shower RoomB30A-5270D1B0041AB0042AB0065BA-7101C11A-3101PROVIDE A WATER PROOFING, INSULATION ANDDRAINAGE PANEL. EXTEND DRAINAGE BOARD TOINVERT OF FOUNDATION DRAIN AND BACKFILL WITH12” OF DRAINAGE MATERIAL AT WEST FOUNDATION9D9D19D19D19D19D19D9D9D9D3H13D9D9D9D9D9D9D13D9D3H9D9D3H9D19D19D21M21M19D9D9D9D9D9D9D9D9D9D9D9D3H9D9DEXISTING EGRESS STAIR,SEE A-700321M21M13DB02B04B069' - 10"11' - 2"27' - 0"16' - 0" 16' - 0" 16' - 0"16' - 0" 16' - 0" 16' - 0"B11B11StorageACCESSSCONTROLPOSTA-7001CA5A-7001CA319DA5A-54209D9D9D9D9D9D9D9D9D9D13D13D1A2B3H3H3H2G3H3HB0040BB0001AB22AB0061B35B36BB384' - 11"16' - 4"9' - 5"12' - 8 1/2"9 1/2"4' - 6"1' - 0"1' - 2 5/16"9' - 11"ALIGN CENTERLINEOF PARTITION WITHCOL GRID9 1/2"1' - 0 3/4"4' - 0"ALIGN CENTERLINEOF PARTITION WITHCOL GRID3' - 2"7' - 5"7' - 5"3' - 1"5' - 6 1/4"2' - 0"4' - 4"4' - 10 7/8"2' - 6"3' - 10 1/2"1' - 1"3' - 4"ALIGN9' - 1 1/4"12' - 7"5' - 9"15' - 2 1/2"ALIGN PARTITION WITHGRID CENTERLINE1' - 4"1' - 4"2' - 2"11' - 8 1/4"1' - 1"10' - 1"1' - 4"24' - 1"6' - 4"4' - 8"5' - 6"5' - 8"7' - 6"6' - 9"A-5100C4A-5100C4B0005OPEN STAIR NWA-52041EQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQ EQEQA-5321A2Sim.A-5321A2Sim.A-5321A4Sim.A-5321A3A-5321A3Sim.A-5321A4Sim.Sim.2B3G3' - 0"1' - 11"3H1' - 9"12' - 0"6' - 3 1/8"6' - 8 1/2"6' - 10 3/4"21M21M9D7' - 11"3H3' - 4"1' - 0"5' - 4"TRASH RECEPTACLE, SEE A-5500 SERIES10D10D9D9DE1A-5400AWIRE MESHSTORAGE CAGE2' - 0"WIRE MESHSTORAGE CAGES13D13FEXISTING FOUNDATION WALL3' - 0 1/2"4 MODULES @ 4'16' - 0"4 MODULES @ 4'16' - 0"PLAN LEGENDDENOTES AREA NOT IN PROJECT SCOPESCOPE LIMITED TO NEW SPRINKLER COVERAGEMILLWORKNEW WALL CONSTRUCTIONEXISTING PARTITION TO REMAINNEW DOOREXISTING DOOR TO REMAINEQUIPMENT ZONEEQ.PARTITION & DOOR NOTES1. PARTITIONS LOCATED BY DIMENSION STRING ARE DIMENSIONED TO THE UNFINISHED FACE OF THEWALL UNLESS NOTED OTHERWISE.2. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA:- CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE(SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THANSTUD WIDTH ON THE LINE.- ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED.- MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".3. UNLESS NOTED OTHERWISE, TYPICAL PARTITION TYPE IS 9D.4. DOOR OPENINGS ARE DIMENSIONED TO CENTERLINE OF OPENING U.O.N. IF NOT DIMENSIONED, THEHINGE SIDE OF DOOR JAMBS SHALL BE SPACED 4" FROM THE ADJACENT WALL.01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 3:25:34 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtA-2100ALEVEL 00 PARTIALPLAN - PART ACAS/WCMDC/CW031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.com 1/8" = 1'-0"1ENLARGED LEVEL 00 - Part ANO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/31