Loading...
HomeMy WebLinkAbout_Conformed Set Volume 1 10UP122345688910111213141516171819206.18.18.910.12.6ABCDEFGHJKLMNPQOSTQ.1Q.6R.3290 SFBuilding Services142 SFElev F.1246 SFEgress Stair S45 SFShaft197 SFEgress Stair N75 SFElev P.1227 SFEgress Stair WDrop Tower Shaft1231 SFSouth CorridorMail RoomAcct RepresentativesAcct RepresentativesLead FinanceResearch AdminSmall Medium ClassroomLarge Multi-Purpose Conference Pantry KitchenInformal Collaboration25 SFAV Storage34 SFAV Storage23 SFAV Storage19 SFAV StorageLoungeSmall ClassroomMAE Wind Tunnel EquipmentSmall ClassroomLarge Flexible ClassroomFluid Dynamics - Wind Tunnel LabWind Energy Lab (Barthelmie)Fluid Dynamics - Tow Tank LabFluid Dynamics - Water Channel Lab19 SFAV Storage152 SFTerrace Vestibule1929 SFWest Corridor1741 SFNE Lobby171 SFNE Vestibule96 SFShaft54 SFShaft402 SFGrumman Corridor92 SFToilets24 SFCustodialShaftDirector AdministrationMAE Student Support OfficeOffice Service CenterShaft294 SFOpen Stair NE31 SFElecSm. ConferenceMAE Administration Office2FB2FB 2FB2FB2FB2FB2FB2FB 2FB2FB2FB2FB 2FB2FB2FB 2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FBDOOR419453 68"63"2FB2FB2FB2FB2FB2FB 2FB2FB2FB2FB2FB2FB2FB2FB2FB2FBUG Program Asst & Work StudyUndergrad Advisor/Coord.2FB2FB2FB2FB2FB2FBEXITEXITROOFElec2FB2FBTelecom2FB2FB1FB 1FB 1FB 1FB1FB1FB1FB 1FB 1FB2FB2FB 2FB2FB 2FB2FB 2FB2FB2FB2FBGATEOPEN TOBELOW29 SFElecCONVERGING OCCUPANTLOAD (BASEMENT ANDSECOND FLOOR) =417CONVERGINGOCCUPANT LOAD(BASEMENT ANDSECOND FLOOR) =419R.520.3R.41119 SF75 OCC.A315-ASSEMBLY1365 SF91 OCC.A315-ASSEMBLY815 SF41 OCC.A320-ASSEMBLY269 SF3 OCC.B100-BUSINESS215 SF15 OCC.B15-BUSINESS402 SF4 OCC.B100-BUSINESS93 SF1 OCC.B300-BUSINESS159 SF2 OCC.B100-BUSINESS163 SF2 OCC.B100-BUSINESS207 SF3 OCC.B100-BUSINESS134 SF2 OCC.B100-BUSINESS154 SF2 OCC.B100-BUSINESS144 SF2 OCC.B100-BUSINESS138 SF2 OCC.B100-BUSINESS137 SF2 OCC.B100-BUSINESS577 SF29 OCC.B20-BUSINESS574 SF29 OCC.B20-BUSINESS1977 SF99 OCC.A320-ASSEMBLY2529 SF52 OCC.A350-ASSEMBLY604 SF13 OCC.B50-BUSINESS620 SF13 OCC.B50-BUSINESS948 SF19 OCC.B50-BUSINESS666 SF14 OCC.B50-BUSINESS334 SF23 OCC.B15-BUSINESSGRUMMAN3972 SF50&100 71 OCC.262 SF3 OCC.B100-BUSINESSFIXED BENCH SEATING18" PER PERSON = 37 OCCUPANTS170 SF1 OCC.B300-BUSINESS417440 66"63"DOOR148440 66"32"DOOR405440 66"52"DOOR405440 66"52"DOOR405440 66"61"DOOR2FB2FB71440 66"32"DOORTOTAL DISTANCE154'-9" < 250'-0"TOTAL DISTANCE151'-7" < 250'-0"TOTAL DISTANCE104'-2" < 250'-0"TOTAL DISTANCE164'-0" < 250'-0"GATE6' - 8"5' - 7"2 HR RATED RETRACTABLEFIRE DOOR81 SF1 OCC.S2300-STORAGE140 SF1 OCC.B300-BUSINESSDNDNDNDNUPDNUPOPEN TO BELOWSTAIR148220 33"32"2FB95 SFToilets1FB 1FB132 SF1 OCC.B300-BUSINESS337 SF4 OCC.B100-BUSINESSDirector MAE90909090902FB2FB9082 SF1 OCC.B300-BUSINESSStorage / ClosetStorage1FB1FB1FB9045CRCRCRCRCRCRCRCRCRCRCRCRCRCRCRCRCRCRCRShaftDN45452FBSTAIR247270 54"50"STAIR287310 62"57"STAIR247270 54"50"2FB2FB2FB90CONTROL AREA BOUNDARYCONTROL AREA BOUNDARYCONTROL AREA BOUNDARYCONTROL AREA BOUNDARYOPEN TO BELOWFEC2FB2FB2FB2FB296 SF3 OCC.B100-BUSINESSExhibitionCustodialUnisexMen Women3' - 8"DNEXITFEFEFEFE2FB2FB2FBEXISTING SHAFTCONFIRMRATING OFEXISTING SHAFTWALL, TYP.2FB2FBEXISTING DRINKING FOUNTAIN2FB2FB2FB2FB1FBFECFVCFECFECFECR1:12 RAMP 1:12 RAMP1:12 RAMP2FB2FB2FB2FB2FB 2FB2FBMAINTAIN EXISTINGFIRE RATEDSEPARATIONEXISTINGTERRACE3FB3FB3FB3FB3FB3FB3FB 3FB3FBFE4' - 9"5' - 1 1/8"1FB1FB 1FB1FBCOVER WINDOWWITH SOLID WALLCONSTRUCTION1801801801FB1FB1FB4545INCREASEDSPRINKLERCOVERAGECONTROL AREA BOUNDARY3FB 3FB1FB3FB2FB2FB2FBA3-ASSEMBLY1217 SF15 82 OCC.3FB3FB3FB3FB3FB180EXISTING CMU WALL AND OPENINGS TOREMAIN2FB2FB1FB1FB 1FB1FBCRMMMFECEXISTING TERRACEAND EXTERIOR EGRESSPATH TO REMAINPARTITION RATINGS DESIGNATIONS3-HOUR FIRE BARRIER2-HOUR FIRE BARRIER1-HOUR FIRE BARRIER1-HOUR SMOKE BARRIERDOOR SYMBOLSEXIT SIGNAGEPATH OF TRAVELLIFE SAFETY EGRESS SYMBOL3FB2FB1FBSB140240 72"44"CORRACTUAL CUMULATIVEPOPULATIONWIDTH REQ'D BY CODEBASED ON ACTUALCUMULATIVEPOPULATIONACTUAL WIDTHPROVIDEDPOPULATION PERMITTEDBASED ON WIDTHPROVIDED3FB2FB1FBSBNOTE: S-1 AND S-2 OCCUPANCIES ARE LIMITED TO 10% OFTHE FLOOR AREA AND ARE CONSIDERED ACCESSORYSPACES.FIRE PROTECTION EQUIPMENTFEC10'-0" <250'-0"SEMI-RECESSED FIREEXTINGUISHER CABINETFVCTRAVEL DISTANCE< REQ'D DISTANCEEXITSURFACE MOUNTED FIREDEPARTMENT VALVE CABINET WITHFIRE DEPARTMENT VALVE AND 10#ABC FIRE EXTINGUISHER.OCCUPANCY CLASSIFICATIONSLIFE SAFETY LEGENDA3-ASSEMBLY3,557 SF20 178 OCC.OCCUPANCY GROUPAREATOTAL OCCUPANTSOCCUPANT LOAD FACTORCREXIT DOORACCESS CONTROL DOORSEQUIPPED WITH CARD READERWALL MOUNTEDCLG MOUNTEDBRACKET MOUNTED FIREEXTINGUISHER.FEFECSURFACE MOUNTED FIREEXTINGUISHER CABINETFVCSEMI-RECESSED FIREDEPARTMENT VALVE CABINET WITHFIRE DEPARTMENT VALVE AND 10#ABC FIRE EXTINGUISHER.MACCESS CONTROL DOORSEQUIPPED WITH DOOR MONITORFIRE SERVICE PHONE01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96194/1/2015 2:34:37 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtLS-0101LEVEL 01 LIFESAFETY OVERALLCASAHS031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity 3/32" = 1'-0"1LEVEL 01 LIFE SAFETY OVERALL215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.comNOTE: NO SCOPE AT GRUMMAN. SHARE EGRESSWITH UPSON.REQUIRED:WATER CLOSETLAVATORIESMALEFEMALEMALEFEMALEDRINKINGFOUNTAINSBATHTUBS ORSHOWERSSERVICE SINKPLUMBING CODE CALCULATIONSOCCUPANTS: 358(179 MALE 179 FEMALE)OCCUPANCY: ASSEMBLY - A-31.001.002.751.431.00REQUIRED:DRINKINGFOUNTAINSBATHTUBS ORSHOWERSSERVICE SINKWATER CLOSETLAVATORIESMALEFEMALEMALEFEMALEOCCUPANTS: 303(152 MALE 152 FEMALE)1OCCUPANCY: Business - B12.902.904.044.043.03OCCUPANCY LOAD - LEVEL 01Name Area SF/Occ. OccupantsA3Large Flexible Classroom 1,977 SF 20 99Large Multi-Purpose Conference 1,119 SF 15 75Lounge 1,365 SF 15 91MAE Wind Tunnel Equipment 2,529 SF 50 51Small Medium Classroom 815 SF 20 41357BAcct Representatives 154 SF 100 2Acct Representatives 144 SF 100 2Bench Seating 19 SF 0.525 37Director Administration 159 SF 100 2Director MAE 337 SF 100 4Drop Tower Shaft 170 SF 300 1Exhibition 296 SF 100 3Fluid Dynamics - Tow Tank Lab 604 SF 50 13Fluid Dynamics - Water Channel Lab 620 SF 50 13Fluid Dynamics - Wind Tunnel Lab 948 SF 50 19Informal Collaboration 334 SF 15 23Lead Finance 138 SF 100 2MAE Administration Office 402 SF 100 5MAE Student Support Office 269 SF 100 3Mail Room 134 SF 100 2Office Service Center 132 SF 300 1Pantry Kitchen 262 SF 100 3Research Admin 137 SF 100 2Sm. Conference 215 SF 15 15Small Classroom 577 SF 20 29Small Classroom 574 SF 20 29Storage 93 SF 300 1Storage / Closet 82 SF 300 1Telecom 140 SF 300 1UG Program Asst & Work Study 207 SF 100 3Undergrad Advisor/Coord. 163 SF 100 2Wind Energy Lab (Barthelmie) 666 SF 50 14232S2Elec 81 SF 300 11TOTAL 590TOTAL REQUIRED:641744TOTAL PROVIDED:*Per IPC 410.1, Water Coolers with Bottled Water Dispensers shall be permitted to be substituted for notmore than 50 percent of the required drinking fountains.Refer to IBC Chapter 29 and Table 29-A "Minimum Plumbing Fixtures" for specifics, exceptions, andfootnotes.75*28560GRUMMAN LEVEL 01Name SF/Occ. OccupantsGrumman Labs 50 60Grumman Offices 100 1171661TOTAL OCCUPANTS:OCCUPANCY =1 PERSON PER18" OF BENCH1540TOTAL EXIT CAPACITY:NO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/3118"/OCC55 LF