Loading...
HomeMy WebLinkAbout_ALL Volume 2 Conformed Set 87F/SF/SF/SF/SF/SF/SF/SF/SF/SF/SF/S F/SF/SF/SF/SF/SF/SF/SF/SF/SF/SF/S123 5 891011121314151617181920 6.18.1 L M N P Q O R S T Q.1 Q.6 R.3 20.2 02 0205 0508 08 R.5 20.3 R.4 Faculty Office 343 Faculty Office 347 Faculty Office 351 Sm. Conference 349 Sm. Office-Students 344 Hybrid Lab - Unassigned 342 Grain Flow Research Lab 350 Energy Environ Research Lab 348 Hybrid Lab - Unassigned 329 Egress Stair N 30002 Elev P.3 30070 Faculty Office 305 Faculty Office 307 Faculty Office 309 Faculty Office 311 Faculty Office 315 Faculty Office 317 Faculty Office 319 Faculty Office 321 Faculty Office 313 Touch-Down / Hoteling Workspace 301 Emeritus Suite 310 Office-Students 314 Office-Students 302 NE Corridor 30041 Med. Office-Students 352 Exhibition 30040A Shaft SH301 Hybrid Lab - Unassigned 325 Shaft SH303 Faculty Service Center 340 Shaft SH203 Shaft SH306 Sm. Conference 323 West Corridor 30040 Shaft SH308 Shaft SH311 Shaft SH312 Elec 30060 Open Stair NE 30003 Egress Stair W 30001 Dry / Computational Lab 306 Research Conference 331 Informal Collaboration 337 Shaft SH304 Office-Students 304 Office-Students 341 V12 FCU V12 FCU V10 FCU V10 FCU V12 FCU V02 FCU V02 FCU V02 FCU V02 FCU V02 FCU V02 FCU V02 FCU V02 FCU V02 FCU V08 FCU V08 FCU V08 FCU V08 FCU V03 FCU V03 FCU V03 FCU V04 FCU HR02 FCU V10 FCU V10 FCU V10 FCU V10 FCU HR02 FCU H08 FCU H02 FCU H02 FCU H02 FCU H03 FCU V10 FCU V12 FCU 12"x8"SA 60 ZRT V06 FCU 30 ZRT TYP. OF 9 CD 220 CFM 3-1 VAVS 3-7 VAVS CR 200 CFM CD 200 CFM 3-5 VAVR 3-6 VAVS CD 200 CFM 3-3 VAVS CR 200 CFM CD 200 CFM 3-5 VAVS CR 280 CFM CD 280 CFM 3-2 VAVS CR 620 CFM CD 310 CFM 3-7 VAVR 3-8 VAVS CR 410 CFM 3-10 VAVS 3-11 VAVS CD 410 CFM CD 425 CFM 60 ZRT 100 ZRT 28X20 TEX UP 28X16 TEX DN HR06 FCU H06 FCU 50 ZRT 75 ZRT 75 ZRT EG 450 CFM 3-1 VAVE 3-2 VAVE 26"x8"EA EG 450 CFM 12"x8"RA 3-4 VAVR 3-1 VAVR 20' FT-A 5' FT-A 36' FT-A 12' FT-A 16"x8"RA80 ZRT 3-9 VAVS 12"x5"SA 3-8 VAVR 3-3 VAVE 3-4 VAVE 3-14 VAVS CD 400 CFM 3-16 VAVS 3-15 VAVS 3-6 VAVE (3)4" TAP W/CAP CD 260 CFM V02 FCU V12 FCU Telecom 328 Elec 30062 80 ZRT CR 260 CFM 3-11 VAVR CR 400 CFM 3-17 VAVE CD 220 CFM 3-7 VAVE 3-13 VAVR3-17 VAVS CR 220 CFM DUCT SHAFT 12 14X10 SAD UP/DN DUCT SHAFT 11 14X10 SAD UP/DN DUCT SHAFT 10 14X20 EAD UP 14X20 RAD UP/DN DUCT SHAFT 8 20X16 EAD UP/DN 20X18 FUTURE DUCT UP/DN 20X16 RAD UP/DN 20X35 SAD UP/DN DUCT SHAFT 9 55X18 SAN UP/DN 22X18 RAD UP/DN 24X18 EAD UP/DN DUCT SHAFT 15 20X16 EAD UP/DN 12X12 RAD UP/DN 20X30 SAD UP/DN DUCT SHAFT 14 26X24 SAD UP/DN 26X24 RAD UP/DN DUCT SHAFT 13 24X18 SAD UP 16X14 SAN DN 20X18 RAD UP 16X14 RAD DN DUCT SHAFT 2 24X10 SAD UP 12X6 SAD DN DUCT SHAFT 10 34X20 SAD UP 14X20 SAD DN 12"x6"RA CD 310 CFM 12"x6"SA 16"x8"SA12"x5"SA 12"x5"RA CR 200 CFM V10 FCU DUCT SHAFT 3 16X12 RAD UP/DN 20X12 SAD UP/DN 12"x8"SA 14"x6"SA 20"x8"SA 24"x8"EA 14"x8"EA14"x8"EA12"x8"SA 20"x8"RA (6)4" TAP W/CAP TYP. 14"x8"SA 20"x8"EA 16"x8"SA 14"x8"EA (2)4" TAP W/CAP MATCHLINE SEE /1 M-2003B MATCHLINE SEE /1 M-2003B CD 180 CFM CR 180 CFM 3-12 VAVS 3-10 VAVR CD 180 CFM 14"x6"SA 3-25 VAVS HR04 FCU HR04 FCU 20"x12"TRANSFERTG 16"x16" TYP (4)16"x6"SA16"x6"SA 16"x6"EA CR 16"x6"EA12"x6"RA 12"x6"SA 12"x5"SA WG 220 CFM 3-19 VAVS 14"x8"EA CR 12"x5"RA12"x6"SAL01a3-2 VAVR 3-4 VAVS CD 220 CFM 12"x6"SA CR 220 CFM 3-3 VAVR 12"x6"SA 12"x5"RA12"x5"RA CD 100 CFM CD 100 CFM 3-27 VAVS 12"x5"RA12"x6"SA 12"x6"RA Office 322B Conference 316 CR 425 CFM 3-9 VAVR CR CR CR 7 FT-C 8' FT-C Biomechanics Computing Lab 322 Office 322A CD 100 CFM 3-28 VAVS 12"x5"SA 3-13 VAVS WG 400 CFM BMS CONTROL PANEL COORDINATE EXACT LOCATION WITH IT 12"x6"SA12"x5"SA 3-5 VAVE (3)4" TAP W/CAP 12"x6"RA 120 ZRT 6"øEA 16"x8"SA 12"x5"EA 16"x8"EA20"x10"EA 14"x8"EA 18"x8"SA HR06 FCU Sheet Title Approved Checked Drawn Job Number Date Sheet Information Revisions MEP FP ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 162345 A E B C D 162345 A E B C D Copyright © 2013 Perkins+Will 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 AV / ACOUSTICS The Sextant Group 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 C:\Users\edgar.avila\Documents\Upson Hall_MECH_PLUMB_FP_Josue.Avila.rvtM-2003A MECHANICAL CONSTRUCTION PLAN - LEVEL 03 PART A MEE MEE 031549.000 11/07/2014 MEE Upson Hall Renovation 124 Hoy Rd, Ithaca, NY 14850 Cornell University 215 Park Avenue South 4th Floor New York, NY 10003 t 212.251.7000 f 212.251.7111 www.perkinswill.com GENERAL NOTES 1. SEE PHASING NOTES ON LEGEND SHEETS 2. CONDENSATE DRAIN PIPE SHALL BE PITCHED AT 1/8" PER FOOT. 3. DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND ARE PROVIDED TO CONVEY THE DESIGN INTENT. REGARDLESS OF HOW INDICATED, ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ALL MANUFACTURER'S RECOMMENDATIONS AND AS REQUIRED TO PROVIDE NEC, SERVICE AND MAINTENANCE CLEARANCES. PROVIDE ADDITIONAL OFFSETS AND FITTINGS AS REQUIRED FOR DUCTWORK AND PIPING. 4. REFER TO SPECS FOR INSULATION REQUIREMENTS ON DUCTWORK AND PIPING. ALL CONCEALED DUCTWORK AND PIPING SHALL BE INSULATED PER ENERGY CODE. 5. ALL EXPOSED DUCTWORK SHALL BE PAINTED AS PER ARCHITECT SPECIFICATION AND NOT INSULATED. ALL CONCEALED DUCTWORK SHALL BE INSULATED AS PER SPECIFICATIONS. 6. ALL VAV BOX AND FAN COIL HOUSING SHALL BE LINED AS PER ACOUSTICAL ENGINEERS REPORT. 7. BRANCH DUCT SIZES TO AIR DEVICES ARE EQUAL TO AIR DEVICE NECK SIZE, UNLESS NOTED OTHERWISE. 8. PROVIDE AN ACCESSIBLE, MANUAL VOLUME DAMPER AT EVERY BRANCH DUCT AND FOR EVERY INLET/OUTLET. PROVIDE MANUAL VOLUME DAMPER UPSTREAM OF ALL ZONE REGISTER TERMINALS. 9. ROUND SUPPLY DUCT SIZES TO VAV BOXES ARE EQUAL TO CONNECTION SIZE UNLESS NOTED OTHERWISE. 10. PROVIDE RECOMMENDED STRAIGHT DUCT INLET LENGTHS FOR ALL SOUND ATTENUATORS AND VAV BOXES. 11. ALL VAV BOXES SHALL BE INSTALLED ABOVE CEILINGS. 12. COORDINATE WITH ALL TRADES TO MAINTAIN ACCESS CLEARANCE TO EQUIPMENT. 13. CONTRACTOR TO FIELD COORDINATE ACCESS PANELS IN FINISH CEILING TO MAINTAIN ACCESS TO EXISTING DUCT MOUNTED ACCESS DOORS. SUBMIT PROPOSED ACCESS PANEL LOCATIONS FOR APPROVAL PRIOR TO INSTALLATION. 14. ALL DUCTS PENETRATING 1-HOUR RATED CONSTRUCTION SHALL BE EQUIPPED WITH AN APPROVED FIRE DAMPER AND INSTALLED AS PER DETAIL. 15. ALL DUCTS PENETRATING RATED SHAFTS AND 2-HOUR RATED CONSTRUCTION SHALL BE EQUIPPED WITH AN APPROVED FIRE SMOKE DAMPER AND INSTALLED AS PER DETAIL. 16. ALL PIPING PENETRATION 1-HOUR AND 2- HOUR RATED CONSTRUCTION SHALL BE INSTALLED AS PER DETAIL. 17. ALL DIFFUSERS SHALL BE HARD DUCTED AS PER DETAIL. 18. ALL PIPING FOR VERTICAL FAN COIL UNITS IS TO BE LOCATED WITHIN PIPE ENCLOSURE BELOW WINDOWS. 19. CONTROL VALVES SHALL BE PROVIDED FOR EACH PIECE OF HYDRONIC EQUIPMENT. SEE DETAIL SHEETS FOR PIPING CONFIGURATION. 19. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGN GUIDELINES FOR LAYOUT AND PLACEMENT OF ALL EXPOSED INFRASTRUCTURE INCLUDING PIPING, SPRINKLERS, CONDUIT, DUCTWORK, CABLE TRAYS, LIGHTING AND CEILING DEVICES. CONSULT ARCHITECT IF ANY QUESTIONS ARISE ABOUT DESIGN INTENT. KEYNOTES# NO ISSUE DATE 1 100% DD DOCUMENTS 14/08/28 2 50% CONSTRUCTION DOCUMENTS 14/11/07 3 BID SET 15/02/27 4 Addendum No. 3 15/03/31 1/8" = 1'-0"1 MECHANICAL CONSTRUCTION PLAN - LEVEL 03 PART A