Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_ALL Volume 2 Conformed Set 408
2 1 DC CR FIRST LEVEL 2 1 TELECOM ROOM B34 (MTR) TR 128 BASEMENT LEVEL SECOND LEVEL 3 THIRD LEVEL FOURTH LEVEL CAMPUS POLICE HEADEND AND MONITORING STATION UPSON HALL BARTON HALL CPW HDS JB REX ISC 4 5 6 3 ISC 3 7 DC CR 3 JB REX 4 5 7 3 2 1 TR 228 ISC DC CR 3 JB REX 4 5 7 3 2 1 TR 328 ISC DC CR 3 JB REX 4 5 7 3 2 1 TR 428 ISC DC CR 3 JB REX 4 5 7 3 FIFTH LEVEL 2 1 TR 528 ISC DC CR 3 JB REX 4 5 ROOF LA LA LA LA LA LA 3 3 3 3 3 SECURITY SYMBOLS LEGEND IP SURVEILLANCE CAMERALOCAL ALARM SOUNDERLA DOOR CONTACTDC JUNCTION BOXJB CARD READER DEVICECR INTELLIGENT SYSTEM CONTROLLERISC REQUEST-TO-EXIT DEVICEREX HEAD-END DATABASE SERVERHDS CAMPUS POLICE WORKSTATIONCPW Sheet Title Approved Checked Drawn Job Number Date Sheet Information Revisions MEP FP ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101 Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 162345 A E B C D 162345 A E B C D Copyright © 2013 Perkins+Will 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 AV/ IT/ ACOUSTICS The Sextant Group, Inc. 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 Y-4000 SECURITY RISER DIAGRAM Checker Author 031549.000 08/25/2015 Approver Upson Hall Renovation 124 Hoy Rd, Ithaca, NY 14850 Cornell University 215 Park Avenue South 4th Floor New York, NY 10003 t 212.251.7000 f 212.251.7111 www.perkinswill.com NO ISSUE DATE 1 ADDENDUM NO. 2 15/03/20 GENERAL NOTES 1. ALL DEVICES SHOWN AS TYPICAL. 2. ALL CONDUIT, CABLE TRAYS, PATHWAYS, AND CABLES TO BE COORDINATED WITH ELECTRICAL, TELECOMMUNICATIONS, AND ARCHITECT. 3. CONDUIT PATHWAYS AND CABLE TRAY SYSTEMS PROVIDED AND INSTALLED BY DIV. 26 CONTRACTOR. KEYED NOTES SECURITY WALL MOUNT ENCLOSURE1 TELECOM RACK. COORDINATE MOUNTING OF EQUIPMENT WITHIN RACK WITH OWNER AND DIV. 27 CONTRACTOR. 2 SEE SPECIFICATIONS FOR CABLE TYPE AND QUANTITY3 4 PROVIDE CATEGORY 6 CABLE TO DEVICE 3/8" = 1'-0"Y-4000 1 SECURITY RISER DIAGRAM GENERAL NOTES 1. THESE DRAWINGS MUST BE USED IN CONJUNCTION WITH THE SECURITY SYSTEM AND ELECTRICAL SPECIFICATIONS. 2. FURNISH AND INSTALL FIRE STOP TO ALL SLAB AND WALL PENETRATIONS PROVIDED FOR THE INSTALLATION OF SECURITY CABLE AS REQUIRED TO MAINTAIN FIRE RATING OF SLAB OR WALL. 3. NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THESE CONTRACT DRAWINGS AND FIELD CONDITIONS. 4. INSTALL ALL COMPONENTS AS PER MANUFACTURERS RECOMMENDATIONS AND PER ALL APPLICABLE CODES. 5. INDICATE ALL MOUNTING REQUIREMENTS IN THE LEGEND UNLESS OTHERWISE NOTED. 6. VERIFY AND COORDINATE THE EXACT MOUNTING LOCATION OF ALL DEVICES PRIOR TO INSTALLATION. 7. THE MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE DEVICE UNLESS OTHERWISE NOTED. 8. RESTORE CEILINGS AND WALLS AND ANY OTHER SURFACES AFFECTED BY THIS WORK WITH LIKE MATERIALS TO MATCH EXISTING CONSTRUCTION UPON COMPLETION OF THE SECURITY WORK. ELECTRICAL DRAWINGS: 1. COORDINATE WALL BOX LOCATIONS AND DIMENSIONS WITH ARCHITECTURAL AND ELECTRICAL DRAWINGS. 2. COORDINATE WITH ELECTRICAL DRAWINGS FOR LOCATION OF ALL SECURITY INFRASTRUCTURE. CONDUIT: 1. COORDINATE CONDUIT AND LADDER RACK FOR SECURITY WIRING TO MAINTAIN A MINIMUM OF 5” SEPARATION FROM LIGHTING FIXTURES. 2. COORDINATE INSTALLATION OF CONDUITS AND CABLE TRAYS WITH OTHER COMPONENTS INSTALLED WITHIN THE CEILING. PREPARE ALL SHOP DRAWINGS TO DEMONSTRATE AND ENSURE PROPER INSTALLATION OF ALL COMPONENTS. 3. MAINTAIN MINIMUM BEND RADIUS OF 10 X O.D. FOR SECURITY CONDUITS EQUAL TO OR LESS THAN 2” DIAMETER. 4. PROVIDE PULL BOXES, ELBOWS IN LIEU OF A BEND. 5. REAM AND BUSH THE ENDS OF ALL CONDUITS. 6. PROVIDE AND LEAVE IN PLACE A PULL STRING IN EACH CONDUIT. PULL STRINGS SHALL ALSO BE INSTALLED IN ALL SPARE/EMPTY CONDUITS. 7. STUB UP CONDUIT SLEEVES THROUGH SLABS 6” ABOVE FINISHED FLOORS. 8. PROVIDE HANGARS, ANCHORS, MOUNTING HARDWARE, GROUND LUGS, AND STRAPS AS REQUIRED TO ENSURE PROPER INSTALLATION OF PATHWAY COMPONENTS. 9. PROVIDE ALL LADDER RACK AND CABLE TRAY LOCATIONS: RUNWAY, DROP-OFFS, SPICE HARDWARE, GROUND STRAPS, THERMAL EXPANSION PLATES, TERMINATION KITS, END SUPPORT KITS, AND CEILING SUPPORT HARDWARE. 10. REFER TO DISTRIBUTION PLANS FOR REQUIREMENTS FOR JUNCTION BOX AND CONDUITS TO SUPPORT WORKSTATION OUTLETS. 11. WHERE CABLE IS RUN ABOVE NON-ACCESSIBLE (I.E., GYPSUM BOARD) CEILING CONSTRUCTION, CONDUITS, AND PULL BOXES MUST BE INSTALLED TO PROPERLY ROUTE CABLE. 12. PROVIDE J-HOOKS AND CABLE STRAPS TO SUPPORT CABLE ABOVE ACCESSIBLE CEILING CONSTRUCTION EXCEPT IN AREAS WHERE CABLE TRAY OR CONDUIT IS INDICATED ON THE DRAWINGS. 13. ALL CONDUIT SHALL BE A MINIMUM OF 1” RGS UNLESS OTHERWISE NOTED. 14. ALL CONDUIT SHALL BE ROUTED ABOVE CEILING, BELOW FLOORS, OR WITHIN WALL SIN THE FINISHED AREAS. NO CONDUIT SHALL BE EXPOSED IN THE FINISHED AREAS UNLESS APPROVED BY DESIGNER. 15. ALL CONDUITS SHALL HAVE PLASTIC BUSHINGS INSTALLED AT OPEN ENDS PRIOR TO PULLING WIRE. 16. ALL BACK BOXES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED. 17. ALL BACK BOXES MOUNTED WITHIN FIRE RATED PARTITIONS SHALL MEET THE FIRE RATING OF THE PARTITION AS REQUIRED BY CODE. 18. COORDINATE THE EXACT LOCATION OF ALL PULL BOXES WITH ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS. 19. ALL JUNCTION AND PULL BOXES SHALL BE PROVIDED WITH ACCOMPANYING BLANK COVER PLATE. 20. JUNCTION BOXES LOCATED ABOVE DOORS WITH NO ACCESSIBLE CEILING SHALL BE SECURED WITH TAMPER PROOF SCREWS. 21. PROVIDE WATERTIGHT SEALING ASSEMBLIES WITH PRESSURE BUSHING AS REQUIRED FOR EXTERIOR PENETRATIONS. 22. JUNCTION AND PULL BOXES IN EXTERIOR LOCATIONS SHALL BE WATERPROOF. 23. JUNCTION AND PULL BOXES IN ROOM AREAS UTILIZING FM200 (SEE FIRE PROTECTION DRAWINGS) SHALL BE VAPOR TIGHT. 24. ALL CONDUIT ROUTING SHOWN IS SCHEMATIC AND DOES NOT REPRESENT INSTALLED PATHS OR DISTANCES. ACTUAL ROUTING AND BOX LOCATIONS SHALL BE FIELD VERIFIED AND COORDINATED WITH OTHER WORK OF THE CONTRACT. CABLE: 1. FURNISH AND INSTALL EACH CABLE SET INDICATED BY THE SYMBOLS LIST FROM THE OUTLET LOCATION BACK TO THE TR/MTR. 2. ALL CABLES SHALL BE PLENUM RATED WHERE REQUIRED. 3. WIRE SHEATH SHALL BE MAINTAINED TO FINAL TERMINATION. ALL TERMINATIONS SHALL MAINTAIN TWIST OF INDIVIDUAL PAIRS TO WITHIN 0.5” OR LESS OF FINAL TERMINATION. LABELING: 1. PROVIDE IDENTIFICATION LABELS FOR ALL TELECOMMUNICATIONS CABLES AT BOTH ENDS. 2. PROVIDE DESIGNATION LABELS FOR ALL TERMINATION BLOCKS, PATCH PANELS, AND WORKSTATION OUTLET FACEPLATES. 3. PRIOR TO SYSTEM ACCEPTANCE, SUBMIT A LABEL REPORT LISTING THE ROOM NUMBERS AND CABLE LENGTHS FOR EACH OF THE INSTALLED CABLES. 4. PROVIDE WHITE LABEL WITH TYPEWRITTEN LEGIBLE CHARACTERS PRINTED WITH NON-SMEAR TYPE INK. HANDWRITTEN LABELS ARE NOT PERMITTED. PROVIDE LABELS FOR CABLES WITH PROTECTIVE WRAP AROUND PLASTIC TRANSPARENT COVER WHICH WILL SERVE TO PROTECT THE INK FROM SMEARING AND SECURE THE LABEL TO THE CABLE. PROVIDE LABELS FOR CABLES WIDE ENOUGH FOR 24 CHARACTERS IN A SINGLE ROW. 5. RISER AND TIE CABLES SHALL BE LABELED WITHIN EACH TELECOMMUNICATIONS ROOM AT 50’ INTERVALS ABOVE CEILINGS OUTSIDE TELECOMMUNICATIONS CLOSETS. 6. ALL WIRES SHALL BE LABELED WITHIN 6.5” OF FINAL TERMINATION. CAMERAS: 1. THE CONTRACTOR SHALL PROVIDE THE MEANS FOR OPTIMUM CAMERA LOCATION, LENS SELECTION AND VIEW. THE CONTRACTOR SHALL PROVIDE A FIXED CAMERA WITH A SERIES OF VARI-FOCAL LENSES FOR THE PURPOSE OF ACQUIRING FIELD OF VIDEO AND VIDEO PICTURE FROM EACH INTENDED CAMERA LOCATION. TO SHOW VARYING FIELD OF VIEWS AND QUALITY OF CAMERA PICTURE. THE CONTRACTOR SHALL OBTAIN CONCURRENCES OF THE SELECTED CAMERA PLACEMENT, LENS SELECTION FIELD OF VIEW, AND PROVIDE IMAGES TO THE DESIGNER FOR ACCEPTED FIELD OF VIEW. 2. UPON COMPLETION OF INSTALLATION DOCUMENT THAT THE CAMERA LOCATIONS AND LENSES CHOSEN/UTILIZED ARE AS SELECTED IN THE INITIAL PROCEDURE AND SUBMIT THE FIELD OF VIEWS PROVIDED BY THE COMPLETED INSTALLATION FOR APPROVAL BY THE DESIGNER THAT THEY ARE COMPARABLE TO THOSE OBTAINED IN THE INITIAL SELECTION PROCEDURE. GENERAL NOTES 5 TYPICAL ACCESS CONTROL DOOR 6 CONNECT TO HEAD-END DATABASE SERVER VIA EXISTING CAMPUS BACKBONE INFRASTRUCTURE. 7 INTRA-BUILDING NETWORK BACKBONE PROVIDED IN PHASE 1. 1