Loading...
HomeMy WebLinkAbout_ALL Volume 2 Conformed Set 264J123 58910111213141516171819206.18.1LMNPQORSTQ.1Q.6R.320.2020205050808R.520.3R.4Egress Stair N10002Elev P.110070Egress Stair W10001Small Medium Classroom102Large Multi-PurposeConference106Pantry Kitchen110Informal Collaboration115AV Storage102AAV Storage106AAV Storage142AAV Storage152ALounge116Small Classroom152Small Classroom146Large Flexible Classroom142AV Storage146ATerrace Vestibule119West Corridor10040NE Lobby10041NE Vestibule10046ShaftSH101Service Corridor10027ShaftSH103ShaftSH104Open Stair NE10003Exhibition140Exhibition325Elec10060Mail Room141Acct Representatives143Acct Representatives147Lead Finance149Research Admin151Elec10062Telecom128Unisex10020Men10022Women10023Custodial10061Bench Seating10040AShaftSH106Sm. Conference135Director MAE139MAE Student Support Office125MAE Administration Office130UG Program Asst & WorkStudy127Undergrad Advisor/Coord.129Director Administration137A1A1A2A2A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A2A2E-50012E-50032A1A2A1LPP-1-3:1LPP-1-3:2LPP-1-3:3LPP-1-3:4LPP-1-3:5LPP-1-3:6LPP-1-3:7LPP-1-3:8LPP-1-3:9LPP-1-3:10LPP-1-3:11LPP-1-3:12LPP-1-3:13LPP-1-3:14LPP-1-1:2LPP-1-1:3LPP-1-1:4LPP-1-1:5LPP-1-1:6LPP-1-1:7LPP-1-1:11LPP-1-1:12LPP-1-1:13LPP-1-1:14LPP-1-1:15LPP-1-1:16LPP-1-1:17LPP-1-1:18LPP-1-1:19LPP-1-1:20LPP-1-1:21LPP-1-1:22LPP-1-1:23LPP-1-1:24LPP-1-1:26LPP-1-1:27LPP-1-1:28LPP-1-3:16LPP-1-3:17LPP-1-3:18LPP-1-3:19LPP-1-3:20LPP-1-3:21LPP-1-3:22LPP-1-3:23LPP-1-3:24LPP-1-3:25LPP-1-3:26LPP-1-3:27LPP-1-3:28LPP-1-3:29LPP-1-3:30LPP-1-3:31LPP-1-3:32LPP-1-3:33LPP-1-3:34GFIGFIGFIGFIGFILPP-1-1:31LPP-1-1:32LPP-1-1:33LPP-1-1:34LPP-1-1:35LPP-1-1:36LPP-1-1:37LPP-1-1:38West Corridor10040LPP-1-1:39LPP-1-1:40LPP-1-1:41LPP-1-1:42LPP-1-1:43LPP-1-1:44LPP-1-1:45LPP-1-1:46LPP-1-1:47LPP-1-1:48LPP-1-1:49LPP-1-1:50LPP-1-1:51LPP-1-1:52LPP-1-1:54LPP-1-1:55LPP-1-1:57LPP-1-1:56LPP-1-1:58LPP-1-1:60LPP-1-1:61LPP-1-1:62GFILPP-1-3:36MATCHLINESEE/1E-2101BMATCHLINESEE/1E-2101BStorage131Office Service Center132Storage / Closet133Duffield Vestibule123Facilities Coordinator153LPP-1-3:35GFIGFIGFIGFIGFI1LPP-1-3:3922222222222222222222PTPTPTPTPTPTPTPTPTPT3333LSPP-B:5LPP-1-3:43,45,472SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.9619C:\Users\wtsui\Documents\REVIT 2015\Upson Hall_ELEC_wtsui.rvtE-2101AELECTRICALCONSTRUCTIONRECEPTACLEPLAN - LEVEL 01PART ACheckerAuthor031549.00011/07/2014ApproverUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.comNO ISSUE DATE1 BID SET 15/02/272 Addendum No. 515/04/08GENERAL NOTES1. CONTRACTOR SHALL VERIFY ALL EXISTINGCONDITIONS AND BE FAMILIAR WITH THE JOBSITE PRIOR TO BID.2. ALL EQUIPMENT PROVIDED BY OTHERSSUCH AS: MECHANICAL, PLUMBING, FIREPROTECTION, IT, AV, AND/OR ARCHITECTURAL,ETC IS SHOWN FOR ELECTRICAL CIRCUITINGINFORMATION ONLY. FOR EXACT QUANTITIESAND LOCATIONS REFER TO THE DISCIPLINESPLANS/SPECIFICATIONS ACCORDINGLY.3. COORDINATE WITH ARCHITECTURAL PLANSFOR EXACT LOCATIONS AND MOUNTINGSHEIGHT OF ALL ELECTRICAL DEVICES.4. ELECTRICAL CONTRACTOR SHALLCOORDINATE EXACT LOCATION OF ALLMECHANICAL UNITS WITH MECHANICALCONTRACTOR.5. ALL EXPOSED CONDUIT SHALL BE ROUTEDPERPENDICULAR, PARALLEL, AND TIGHT TOCOLUMNS AND BEAMS.6. PROVIDE CONDUIT, WIRE, BACKBOXES, ETCAS REQUIRED FOR ALL SECURITY DEVICES.7. ALL BACK BOXES SHALL BE FLUSHMOUNTED UNLESS NOTED OTHERWISE.8. PROVIDE A 120V, 20A EMERGENCYCONNECTION TO ALL SMOKE AND FIRE/SMOKEDAMPERS. DAMPERS SHALL CLOSE UPONACTIVATION OF LOCAL SMOKE OR DUCTSMOKE DETECTOR.9. CONDUIT ROUTING IS SHOWN FOR GENERALINFORMATION ONLY. EXACT ROUTING IS TO BECOORDINATED IN FIELD.10. ALL RECEPTACLES LOCATED IN ELEVATORSHAFTS, ELEVATOR MACHINE ROOMS, ANDEXTERIOR AREAS ARE TO BE WEATHERPROOF, GFI TYPE.11. REFER TO TECHNOLOGY DRAWINGS FORCONDUIT AND BACKBOX REQUIREMENTS ANDLOCATIONS OF TEL/DATA DEVICES.12. ALL MOTORS AND MOTORIZED EQUIPMENTSHALL HAVE OVERCURRENTPROTECTION/DISCONNECTING MEANS AT THEMOTOR/UNIT UON.13. PROVIDE (1) NEUTRAL FOR EACH HOT. NOCOMMON NEUTRALS ARE ALLOWED PERHOME RUN. PROVIDE (1) COMMON GROUNDFOR EACH HOMERUN UNLESS NOTEDOTHERWISE.14. PROVIDE ALL WIRE, CONDUIT, ETC. FORALL DEVICES AS REQUIRED.15. PROVIDE #10 WIRING FOR ALL BRANCHCIRCUITS WHERE CIRCUIT LENGTH EXCEEDS70 FEET, UNLESS NOTED OTHERWISE.16. FIRE STOP ALL PENETRATIONS THROUGHWALLS AND FLOORS.17. FOR MORE INFORMATION REFER TODETAILS SHEETS.18. PROVIDE EXPANSION FITTINGS FOR ALLCONDUIT CROSSING EXPANSION JOINTS,AND/OR MOVING STRUCTURES THAT MOVE ATDIFFERENT RATE RELATIVE TO EACH OTHER.19. ROUTE ALL CIRCUITRY FOR FIRE SMOKEDAMPERS VIA FIRE ALARM RELAY.20. FOR ALL RECEPTACLES LOCATED ATMILLWORK, CONTRACTOR SHALL MOUNTRECEPTACLES FLUSH WITH MILLWORK.COORDINATE WITH MILLWORK CONTRACTOR.21. ALL WIRE ROUTED IN EXPOSED CEILINGSHALL BE ROUTED IN CONDUIT UNLESSOTHERWISE NOTED. ROUTE EXPOSEDCONDUIT PERPENDICULAR, PARALLEL, ANDTIGHT TO COLUMNS AND BEAMS. ALLEXPOSED CONDUIT ROUTING SHALL BECOORDINATED WITH ENGINEER ANDARCHITECT PRIOR TO INSTALLATION. NOADDITIONAL COST TO OWNER WILL BEALLOWED FOR RELOCATING CONDUIT DUE TOTHE LACK OF COORDINATION WITH ARCHITECT.22. ALL DISCONNECTS INDICATED ONDRAWINGS SHALL BE HEAVY DUTY TYPEFUSIBLE UON. ALL DISCONNECTS ANDSTARTERS SHALL BE NEMA 3R WHENLOCATED ON ROOFS AND IN OUTDOORENVIRONMENT.23. COORDINATE PHASING, SHUTDOWNS, ANDSWING-OVER OF FEEDERS WITHOWNER/FACILITIES THREE WEEKS INADVANCE. PROVIDE ALL SHUTDOWNS ANDSWING-OVERS OF ALL FEEDERS AT NIGHT.24. PROVIDE ALL REQUIRED SECURITYCABLING AND RACEWAY FOR ALL DOORACCESS CONTROL COMPONENTS (CARDREADER, ELECTRIC STRIKE, ETC.) ROUTEDFROM DOOR TO TEL/DATA CLOSET SERVINGAREA. REFER TO ELECTRICAL DETAILS SHEET(E-4002/X,Y,Z,AA) FOR TYPICAL DOOR ACCESSCONTROL LAYOUT AND ARCHITECTURAL PLANFOR ACCESS CONTROL DEVICE LOCATIONSAND QUANTITY.25. REFER TO ARCHITECTURAL DRAWINGS FORDESIGN GUIDELINES FOR LAYOUT ANDPLACEMENT OF ALL EXPOSEDINFRASTRUCTURE INCLUDING PIPING,SPRINKLERS, CONDUIT, DUCTWORK, CABLETRAYS, LIGHTING AND CEILING DEVICES.CONSULT ARCHITECT IF ANY QUESTIONS ARISEABOUT DESIGN INTENT.KEYNOTES# 1/8" = 1'-0"1ELECTRICAL CONSTRUCTION RECEPTACLE PLAN - LEVEL 01 PART A1 CONNECT FLOW TEST PUMPS TO CIRCUITLPP-B-1:32.2 ROUTE CONDUITS IN CEILING OF FLOORBELOW.3 PROVIDE POE CAMERA CABLE IN 3/4"CONDUIT TO TEL/DATA CLOSET SERVINGAREA.