Loading...
HomeMy WebLinkAbout_ALL Volume 2 Conformed Set 245F/S F/S F/SF/S F/S F/SF/SF/SF/SF/SF/SF/SF/SF/S F/SF/SJ J J J J J J J J J J J J J J J J J J J JJ J J J J J J J J J J J J J J J J J J J J J J J J J J J J 123 5 891011121314151617181920 6.18.1 L M N P Q O R S T Q.1 Q.6 R.3 20.2 02 0205 0508 08 R.5 20.3 R.4 V10 FCU V10 FCU HR08 FCU HR02 FCU HR02 FCU H10 FCU H06 FCU V10 FCU V10 FCU V10 FCU V10 FCU V10 FCU V08 FCU V08 FCU V08 FCU H06 FCU V10 FCU V10 FCU V02 FCU V02 FCU V02 FCU V10 FCU V10 FCU V10 FCU V10 FCU V10 FCU H04 FCU H10 FCU HR08 FCUE-5003 3 Elec 20062 Telecom 228 Machine Shop / Support 252 Taylor Design Studio 242 Exam Storage/Workroom 246 Teaching Support 248 South Corridor 20042 Shaft SH204 Swanson Lab for Adv. Engineering Simulation 240 NE Corridor 20041 Open Stair NE 20003 Informal Collaboration 231 CIT Computer Lab 225 NE Corridor 20041 Unisex 20020 Custodial 20061 Women 20023 Service Corridor 20024 Men 20022 Elev P.2 20070 Shaft SH203 Egress Stair N 20002 West Corridor 20040 CIT Lab Staff Office 223 Lactation Room 221 West Corridor 20040 Medium Classroom 222 Homework Collection 281 Sm. Conference 219 Meeting 215 Shaft SH202 AV Storage 222A AV Storage 216A Medium Large Classroom 216 Med. Conf./Study 205C Med. Conf./Study 205B Med. Conf./Study 205A Med. Conf./Study 205 Touch-Down / Hoteling Workspace 201 Egress Stair W 20001 West Corridor 20040 Small Medium Classroom 202 Elec 20060 Shaft SH210 AV Storage 206A AV Storage 202A Medium Classroom 206 E-5001 4 2-5 VAVS 2-5 VAVR 2-4 VAVR 2-6 VAVS 2-7 VAVS 2-8 VAVS 2-6 VAVR 2-9 VAVS 2-10 VAVS 2-8 VAVR 2-1 VAVE 2-2 VAVE 2-4 VAVS2-1 VAVS 2-13 VAVS 2-14 VAVS H06 FCU Shaft SH209 Shaft SH201 HPP-2-1:1 HPP-2-1:2 HPP-2-1:3 HPP-2-1:5 HPP-2-1:7 HPP-2-1:4 HPP-2-1:9 HPP-2-1:6 HPP-2-1:11 HPP-2-1:13 HPP-2-1:15 HPP-2-1:8 HPP-2-1:17 80 ZRT 50 ZRT 75 ZRT 75 ZRT 60 ZRT 120 ZRT 60 ZRT 60 ZRT 2-12 VAVS TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TOTO TO TO TO DOWN TO LEVEL 01 UP TO LEVEL 03 LELP-2:5 LELP-2:7 HPP-2-1:30 MATCHLINE SEE /1 E-2002B MATCHLINE SEE /1 E-2002B 2-3 VAVE LELP-2:3 Shaft SH211 2-4 VAVE 2-9 VAVR 1 (TYP) H02 FCU TO 120 ZRT 2-11 VAVS Sheet Title Approved Checked Drawn Job Number Date Sheet Information Revisions MEP FP ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101 Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 162345 A E B C D 162345 A E B C D Copyright © 2013 Perkins+Will 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 AV / ACOUSTICS The Sextant Group 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 C:\Users\edgar.avila\Documents\Upson Hall_ELEC_russell.kent.rvtE-2002A ELECTRICAL CONSTRUCTION MECHANICAL EQUIPMENT PLAN - LEVEL 02 PART A MEE MEE 031549.000 11/07/2014 MEE Upson Hall Renovation 124 Hoy Rd, Ithaca, NY 14850 Cornell University 215 Park Avenue South 4th Floor New York, NY 10003 t 212.251.7000 f 212.251.7111 www.perkinswill.com GENERAL NOTES 1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND BE FAMILIAR WITH THE JOB SITE PRIOR TO BID. 2. ALL EQUIPMENT PROVIDED BY OTHERS SUCH AS: MECHANICAL, PLUMBING, FIRE PROTECTION, IT, AV, AND/OR ARCHITECTURAL, ETC IS SHOWN FOR ELECTRICAL CIRCUITING INFORMATION ONLY. FOR EXACT QUANTITIES AND LOCATIONS REFER TO THE DISCIPLINES PLANS/SPECIFICATIONS ACCORDINGLY. 3. COORDINATE WITH ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND MOUNTINGS HEIGHT OF ALL ELECTRICAL DEVICES. 4. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ALL MECHANICAL UNITS WITH MECHANICAL CONTRACTOR. 5. ALL EXPOSED CONDUIT SHALL BE ROUTED PERPENDICULAR, PARALLEL, AND TIGHT TO COLUMNS AND BEAMS. 6. PROVIDE CONDUIT, WIRE, BACKBOXES, ETC AS REQUIRED FOR ALL SECURITY DEVICES. 7. ALL BACK BOXES SHALL BE FLUSH MOUNTED UNLESS NOTED OTHERWISE. 8. PROVIDE A 120V, 20A EMERGENCY CONNECTION TO ALL SMOKE AND FIRE/SMOKE DAMPERS. DAMPERS SHALL CLOSE UPON ACTIVATION OF LOCAL SMOKE OR DUCT SMOKE DETECTOR. 9. CONDUIT ROUTING IS SHOWN FOR GENERAL INFORMATION ONLY. EXACT ROUTING IS TO BE COORDINATED IN FIELD. 10. ALL RECEPTACLES LOCATED IN ELEVATOR SHAFTS, ELEVATOR MACHINE ROOMS, AND EXTERIOR AREAS ARE TO BE WEATHER PROOF, GFI TYPE. 11. REFER TO TECHNOLOGY DRAWINGS FOR CONDUIT AND BACKBOX REQUIREMENTS AND LOCATIONS OF TEL/DATA DEVICES. 12. ALL MOTORS AND MOTORIZED EQUIPMENT SHALL HAVE OVERCURRENT PROTECTION/DISCONNECTING MEANS AT THE MOTOR/UNIT UON. 13. PROVIDE (1) NEUTRAL FOR EACH HOT. NO COMMON NEUTRALS ARE ALLOWED PER HOME RUN. PROVIDE (1) COMMON GROUND FOR EACH HOMERUN UNLESS NOTED OTHERWISE. 14. PROVIDE ALL WIRE, CONDUIT, ETC. FOR ALL DEVICES AS REQUIRED. 15. PROVIDE #10 WIRING FOR ALL BRANCH CIRCUITS WHERE CIRCUIT LENGTH EXCEEDS 70 FEET, UNLESS NOTED OTHERWISE. 16. FIRE STOP ALL PENETRATIONS THROUGH WALLS AND FLOORS. 17. FOR MORE INFORMATION REFER TO DETAILS SHEETS. 18. PROVIDE EXPANSION FITTINGS FOR ALL CONDUIT CROSSING EXPANSION JOINTS, AND/OR MOVING STRUCTURES THAT MOVE AT DIFFERENT RATE RELATIVE TO EACH OTHER. 19. ROUTE ALL CIRCUITRY FOR FIRE SMOKE DAMPERS VIA FIRE ALARM RELAY. 20. FOR ALL RECEPTACLES LOCATED AT MILLWORK, CONTRACTOR SHALL MOUNT RECEPTACLES FLUSH WITH MILLWORK. COORDINATE WITH MILLWORK CONTRACTOR. 21. ALL WIRE ROUTED IN EXPOSED CEILING SHALL BE ROUTED IN CONDUIT UNLESS OTHERWISE NOTED. ROUTE EXPOSED CONDUIT PERPENDICULAR, PARALLEL, AND TIGHT TO COLUMNS AND BEAMS. ALL EXPOSED CONDUIT ROUTING SHALL BE COORDINATED WITH ENGINEER AND ARCHITECT PRIOR TO INSTALLATION. NO ADDITIONAL COST TO OWNER WILL BE ALLOWED FOR RELOCATING CONDUIT DUE TO THE LACK OF COORDINATION WITH ARCHITECT. 22. ALL DISCONNECTS INDICATED ON DRAWINGS SHALL BE HEAVY DUTY TYPE FUSIBLE UON. ALL DISCONNECTS AND STARTERS SHALL BE NEMA 3R WHEN LOCATED ON ROOFS AND IN OUTDOOR ENVIRONMENT. 23. COORDINATE PHASING, SHUTDOWNS, AND SWING-OVER OF FEEDERS WITH OWNER/FACILITIES THREE WEEKS IN ADVANCE. PROVIDE ALL SHUTDOWNS AND SWING-OVERS OF ALL FEEDERS AT NIGHT. 24. PROVIDE ALL REQUIRED SECURITY CABLING AND RACEWAY FOR ALL DOOR ACCESS CONTROL COMPONENTS (CARD READER, ELECTRIC STRIKE, ETC.) ROUTED FROM DOOR TO TEL/DATA CLOSET SERVING AREA. REFER TO ELECTRICAL DETAILS SHEET (E-4002/X,Y,Z,AA) FOR TYPICAL DOOR ACCESS CONTROL LAYOUT AND ARCHITECTURAL PLAN FOR ACCESS CONTROL DEVICE LOCATIONS AND QUANTITY. 25. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGN GUIDELINES FOR LAYOUT AND PLACEMENT OF ALL EXPOSED INFRASTRUCTURE INCLUDING PIPING, SPRINKLERS, CONDUIT, DUCTWORK, CABLE TRAYS, LIGHTING AND CEILING DEVICES. CONSULT ARCHITECT IF ANY QUESTIONS ARISE ABOUT DESIGN INTENT. KEYNOTES# NO ISSUE DATE 1 100% DD DOCUMENTS 14/08/28 2 50% CONSTRUCTION DOCUMENTS 14/11/07 3 BID SET 15/02/27 4 Addendum No. 3 15/03/31 1/8" = 1'-0"1 ELECTRICAL MECHANICAL EQUIPMENT PARTIAL PLAN - LEVEL 02 PART A 1 POWER CONNECTION TO MECHANICAL DAMPERS AND FIRE/SMOKE DAMPER. CONTRACTOR SHALL COORDINATE EXACT QUANTITIES AND REQUIREMENTS WITH MECHANICAL CONTRACTOR. EXACT LOCATION SHALL BE FIELD COORDINATED.