Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_ALL Volume 2 Conformed Set 173
123 456 891011 6.18.1 8.910.1 2.6 A B C D E F G H J K L M N P Q O R S T Q.1 R.3 02 0205 0508 08 R.5 4"RD 4"VTR 4"VTR 4"VTR 5"V UP THRU ROOF 123 456 891011 6.18.1 8.910.1 2.6 A B C D E F G H J K L M N P Q O R S T Q.1 R.3 02 0205 0508 08 R.5 4"OD 4"RD 4"OD 4"RD 4"OD 4"RD 4"OD 4"RD 4"OD 4"ST/OST DN 3"ST UP TO OD 3"ST UP TO OD 3"ST UP TO RD 3"ST UP TO RD 3"ST UP TO OD 3"ST UP TO RD 3"ST UP TO OD 3"ST UP TO RD 3"ST/OST DN ST 5 ST 1 3"RD 3"OD FD FD FD FD 1-1/2"V DN TO FD 1-1/2"V TO FD 2 FP-5000 Elev F.P 60071 Shaft SH601 Egress Stair N 60002 Elev. Machine Room 60070 Shaft 60061 Mech Penthouse Area 60060 Egress Stair S Top 60004 Elev. Control 60073 Elev F.P 60071 Shaft SH601 Mech Penthouse Area 60064 Egress Stair N 60002 Elev. Machine Room 60070 Shaft 60061 Mech Penthouse Area 60060 Egress Stair S Top 60004 Elev. Control 60073 2"COPPER LINE TO (TVC) IN ROOM 450 TERMINATE 4FT ABOVE ROOF SURFACE OF SHAFT ENCLOSURE WITH GOOSENECK CO CO CO CO3"ST 3"OST 3"ST3"OST3"ST 3"OST 1-1/2"V 1-1/2"V 3"ST3"OSTNote: Refer to architectural drawings for design guidelines for layout and placement of all exposed infrastructure including piping, sprinklers, conduit, ductwork, cable trays, lighting and ceiling devices. Consult architect if any questions arise about design intent. 891011 6.18.1 P Q O R Q.1 R.3 08 08 5"VTR 891011 6.18.1 P Q O R Q.1 R.3 08 08 3"RD 3"OD 3"RD 3"OD 456 2.6 A B C D E 05 05 3"OD 456 2.6 A B C D E 05 05 3"RD 3"OD 3"RD Sheet Title Approved Checked Drawn Job Number Date Sheet Information Revisions MEP FP ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 162345 A E B C D 162345 A E B C D Copyright © 2013 Perkins+Will 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 AV / ACOUSTICS The Sextant Group 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 C:\Users\edgar.avila\Documents\Upson Hall_MECH_PLUMB_FP_ethan.case.rvtP-2006 PLUMBING CONSTRUCTION OVERALL PLAN - LEVEL 06 AND LEVEL 07 MEE MEE 031549.000 11/07/2014 MEE Upson Hall Renovation 124 Hoy Rd, Ithaca, NY 14850 Cornell University 215 Park Avenue South 4th Floor New York, NY 10003 t 212.251.7000 f 212.251.7111 www.perkinswill.com 3/32" = 1'-0"1 PLUMBING CONSTRUCTION OVERALL PLAN - LEVEL 06 NO ISSUE DATE 1 100% DD DOCUMENTS 14/08/28 2 50% CONSTRUCTION DOCUMENTS 14/11/07 3 BID SET 15/02/27 4 Addendum No. 3 15/03/31 3/32" = 1'-0"2 PLUMBING CONSTRUCTION OVERALL PLAN - LEVEL 07 PENTHOUSE ROOF PART A 3/32" = 1'-0"3 PLUMBING CONSTRUCTION OVERALL PLAN - LEVEL 07 PENTHOUSE ROOF PART B