Loading...
HomeMy WebLinkAboutArchitecturalAs_BuiltsPart1of4COMPILED DRAWING SET CORPORATE HEADQUARTERS TOMPKINS FINANCIAL CORPORATION 118 E SENEGA STREET, ITHACA, NEW YORK 14850 HOLTARCHITECTS HOLTARCHITECTS HOLT Architects, P.C. Architects, Planners, and Interior Designers 217 North Aurora Street, Ithaca, New York 14850 Tel 607.273.7600 Fax 607.273.0475 Trowbridge Wolf Michaels Landscape Architects, LLP Landscape Architects, Planners 1001 W. Seneca Street, Suite 101, Ithaca, New York 14850 Tel 607.277.1400 Fax 607.277.6092 Elwyn & Palmer Consulting Engineers, PLLC Structural Engineering 213 E Seneca Street, Ithaca, New York 14850 Tel 607.272.5060 Fax 607.272.5065 T.G. Miller, P.C. Civil Engineering 203 North Aurora Street, Ithaca, New York 14850 Tel 607.272.6477 Fax 607.273.6322 Sack & Associates Consulting Engineers, PLLC Mechanical, Electrical, and Plumbing Engineering 721 E. Genesee Street, Syracuse, New York 13210 Tel 315.471.4013 Fax 315.471.4044 LeChase Construction Services, LLC Construction Manager 205 Indigo Creek Drive, Rochester, New York 14626 Tel 585.254.3510 Fax 585.254.3871 DETAIL ENLARGEMENT DETAIL SECTION WALL SECTION BUILDING SECTION • 50'-6" 50'-6" INTERIOR ELEVATION Name Elevation CEILING HEIGHT PLAN ELEVATION SITE ELEVATION STRUCTURAL ELEVATION WORKING POINT FLOOR ELEVATION DOOR & INTERIOR — - - — CONTRACT LIMIT LINE WINDOW TAG REVISION CLOUD & TAG EXTERIOR WINDOW & LOUVER TAG EQUIPMENT TAG � PARTITIONS, DOORS AND \ i ITEMS TO BE REMOVED EXISTING DOOR ROOM NAME 101 ame Name Name WALL TAG ROOM IDENTIFICATION ROOM FINISH KEY NOTE KEY SCOPE LINE EXISTING PARTITION PROJECT INFORMATION DATE: JOB NUMBER: CONSTRUCTION CLASSIFICATION: SPRINKLER PROTECTION: BUILDING USE CLASSIFICATION: 19 SEP 2017 2015014 IB NFPA-13 B DIMENSION TO THE FACE OF FRAMING AT NEW CONSTRUCTION, TYP. DIMENSION TO THE FACE OF FINISH AT EXISTING CONSTRUCTION TOTAL EXISTING BUILDING AREA: FULL HEIGHT PARTITION SET NUMBER DIMENSION TO THE FACE OF FINISH PARTIAL HEIGHT PARTITION TOTAL AREA OF PROJECT: 108159 /19/2017 10:45:07 1 2 3 4 5 6 7 8 GENERAL * G002 G003 G004 G100 G101 G102 G103 G104 G105 G106 G107 G108 CIVIL — C000 — C001 — C100 — C101 — C102 — C103 — C201 DRAWING LIST BUILDING LOCATION PLAN CODE CONFORMANCE INFORMATION CODE COMPLIANCE PLAN - BASEMENT CODE COMPLIANCE PLAN - FIRST FLOOR CODE COMPLIANCE PLAN - SECOND FLOOR CODE COMPLIANCE PLAN - THIRD FLOOR CODE COMPLIANCE PLAN - FOURTH FLOOR CODE COMPLIANCE PLAN - FIFTH FLOOR CODE COMPLIANCE PLAN - SIXTH FLOOR CODE COMPLIANCE PLAN - SEVENTH FLOOR CODE COMPLIANCE PLAN - ROOF CIVIL LEGEND & NOTES BOUNDARY & TOPOGRAPHIC SURVEY EXISTING SITE CONDITIONS UTILITY DEMOLITION PLAN SITE UTILITY PLAN EROSION AND SEDIMENT CONTROL PLAN SITE UTILITY DETAILS LANDSCAPING — L101 DEMO PLAN — L201 LAYOUT PLAN — L301 — L401 — L501 — L502 GRADING PLAN PLANTING PLAN SITE DETAILS SITE DETAILS PR -12 03 MAY 20 — STRUCTURAL — S001 GENERAL NOTES AND SCHEDULES — S002 SCHEDULE OF SPECIAL INSPECTIONS — S100 BASEMENT FOUNDATION PLAN — S101 FIRST FLOOR FOUNDATION AND FRAMING PLAN — S102 SECOND FLOOR FRAMING PLAN — S103 THIRD FLOOR FRAMING PLAN — S104 FOURTH FLOOR FRAMING PLAN — S105 FIFTH FLOOR FRAMING PLAN — S106 SIXTH FLOOR FRAMING PLAN — S107 SEVENTH FLOOR FRAMING PLAN — S108 ROOF FRAMING PLAN — S300 FOUNDATION DETAILS — S301 FOUNDATION DETAILS — S302 FOUNDATION DETAILS — S303 STRUCTURAL DETAILS — S400 SOUTH ELEVATOR ELEVATION — S401 WEST ELEVATOR ELEVATION — S402 EAST ELEVATOR ELEVATION — S403 NORTH ELEVATOR ELEVATION — 3404 ELEVATOR MASONRY WALL ELEVATION — S405 STAIRWELL MASONRY WALL ELEVATION — S500 FRAMING DETAILS — S501 FRAMING DETAILS — S502 FRAMING DETAILS — S503 STRUCTURAL DETAILS 7 BY OWNER KEY * UPDATED PER ASI -22 MIN NOT INCLUDED IN SET ARCHITECTURAL - FIT OUT * A100a BASEMENT PLAN - FIT OUT A101 a FIRST FLOOR PLAN - FIT OUT * A102a SECOND FLOOR PLAN - FIT OUT * A103a THIRD FLOOR PLAN - FIT OUT * A104a FOURTH FLOOR PLAN - FIT OUT * A105a FIFTH FLOOR PLAN - FIT OUT * A106a SIXTH FLOOR PLAN - FIT OUT * A107a SEVENTH FLOOR PLAN - FIT OUT A108a MECHANICAL PENTHOUSE PLAN A150a BASEMENT REFLECTED CEILING PLAN - FIT OUT * A151a FIRST FLOOR REFLECTED CEILING PLAN - FIT OUT A152a SECOND FLOOR REFLECTED CEILING PLAN - FIT OUT A153a THIRD FLOOR REFLECTED CEILING PLAN - FIT OUT A154a FOURTH FLOOR REFLECTED CEILING PLAN - FIT OUT FIFTH FLOOR REFLECTED CEILING PLAN - FIT OUT SIXTH FLOOR REFLECTED CEILING PLAN - FIT OUT SEVENTH FLOOR REFLECTED CEILING PLAN - FIT A155a A156a * A157a U A160a BASEMENT FINISI I PLAN A161a FIRST FLOOR FINISI I PLAN A162a SECOND FLOOR FINISI I PLAN A163a TI IIRD FLOOR FINISI I PLAN A164a FOURTI I FLOOR FINIS! I PLAN A166a SIXTI I FLOOR FINISI I PLAN A167a SEVENTI I FLOOR FINISI I PLAN A1688 A250a * A251a A252a * A253a A254a A255a * A256a A257a A261a A262a * A401a A402a * A403a * A404a A455a A551 a A552a A561a A562a * A600a * A601a A602a A603a A604a FINISI I SCI IEDULE TYPICAL MOUNTING HEIGHTS AND ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS - TYPICAL CONFERENCE ROOM INTERIOR ELEVATIONS INTERIOR ELEVATIONS - RETAIL SERVICES GREETER & RECEPTION DESK DETAILS RETAIL MILLWORK ENLARGED FLOOR PLANS - FIT OUT TYPICAL TOILET ROOM - FLOOR PLANS AND ELEVATIONS THIRD FLOOR TOILET ROOM - FLOOR PLANS AND ELEVATIONS FIFTH FLOOR TOILET ROOM - FLOOR PLANS AND ELEVATIONS STAIR AND RAILING DETAILS INTERIOR DETAILS INTERIOR DETAILS REFLECTED CEILING PLAN DETAILS REFLECTED CEILING PLAN DETAILS DOOR SCHEDULE - FIT OUT DOOR SCHEDULE - FIT OUT DOOR AND FRAME TYPES - FIT OUT DOOR AND FRAME DETAILS DOOR AND FRAME DETAILS A702a SECOND FLOOR FURNITURE PLAN Mb Ilk - -- _.W A704a FOURTI I FLOOR FURNITURE PLAN A70cra FIFTI I FLOOR FURNITURE PLAN A706a SIXTI I FLOOR FURNITURE PLAN A707a SEVENTI I FLOOR FURNITURE PLAN ASI -22 12 SEP 2017 ARCHITECTURAL - SHELL AND CORE * A001 A002 A100 A101 A102 A103 A104 A105 A106 A107 * A108 Al 09 A151 * A201 A202 A203 * A204 * A205 A206 -R A301 A302 A303 A304 A305 * A311 * A312 * A313 A314 * A315 A316 * A317 * A318 * A319 * A401 * A402 A403 A404 * A451 * A452 A453 A454 A456 * A501 * A502 A503 A504 * A505 * A506 * A507 * A601 A602 A651 SKETCH SK -A SK -B SK -C SK -D SK -E SK -F SK -G SK -H SK -I 3 4 EXTERIOR SYSTEMS AND DETAILS INTERIOR SYSTEMS AND DETAILS BASEMENT PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN THIRD FLOOR PLAN FOURTH FLOOR PLAN FIFTH FLOOR PLAN SIXTH FLOOR PLAN SEVENTH FLOOR PLAN MECHANICAL PENTHOUSE PLAN ROOF PLAN FIRST FLOOR REFLECTED CEILING PLAN EXTERIOR ELEVATION - SOUTH EXTERIOR ELEVATION - WEST EXTERIOR ELEVATION - NORTH EXTERIOR ELEVATION - EAST EXTERIOR ELEVATIONS EXTEIOR ELEVATIONS - LIMESTONE PANEL LAYOUT BUILDING SECTION - NORTH/SOUTH BUILDING SECTION - NORTH/SOUTH BUILDING SECTION - NORTH/SOUTH BUILDING SECTION - EAST/WEST BUILDING SECTION - EAST/WEST SOUTH WALL SECTION SOUTH WALL SECTION @ ENTRY SOUTH WALL SECTION @ DRIVE EAST WALL SECTION NORTH WALL SECTION @ STAIR NORTH WALL SECTION WEST WALL SECTION WEST WALL SECTION @ DARK BRICK WALL SECTIONS ENLARGED FLOOR PLANS ENLARGED FLOOR PLANS ENLARGED FLOOR PLANS ENLARGED FLOOR PLANS SOUTH STAIR PLANS AND SECTIONS NORTH STAIR PLANS AND SECTIONS RETAIL STAIRS PLANS AND SECTIONS STAIR AND RAILING DETAILS ELEVATOR PLANS AND SECTIONS EXTERIOR PLAN DETAILS EXTERIOR PLAN DETAILS EXTERIOR PLAN DETAILS EXTERIOR PLAN DETAILS EXTERIOR SECTION DETAILS EXTERIOR SECTION DETAILS EXTERIOR SECTION DETAILS DOOR SCHEDULE DOOR DETAILS WINDOW ELEVATIONS SKETCH SHEET A SKETCH SHEET B SKETCH SHEET C SKETCH SHEET D SKETCH SHEET E SKETCH SHEET F SKETCH SHEET G SKETCH SHEET H SKETCH SHEET I 5 ASI -22 12 SEP 2017 ASI -08 28 OCT 2016 FIRE PROTECTION FP001 DRAWING INDEX, SYMBOL LISTS, ABBREVIATIONS, AND SCHEDULES FP002 DETAILS FP100 BASEMENT FLOOR PLAN - FIRE PROTECTION FP101 FIRST FLOOR PLAN - FIRE PROTECTION FP102 SECOND FLOOR PLAN - FIRE PROTECTION FP103 THIRD FLOOR PLAN - FIRE PROTECTION FP104 FOURTH FLOOR PLAN - FIRE PROTECTION FP105 FIFTH FLOOR PLAN - FIRE PROTECTION FP106 SIXTH FLOOR PLAN - FIRE PROTECTION FP107 SEVENTH FLOOR PLAN - FIRE PROTECTION FP108 ROOF PLAN - FIRE PROTECTION FP451 STAIR ELEVATIONS - FIRE PROTECTION PIPING RISERS PLUMBING P001 DRAWING INDEX, SYMBOL LISTS, ABBREVIATIONS, & DETAILS P002 PLUMBING SCHEDULES P003 PLUMBING DETAILS & DIAGRAMS P100 BASEMENT PLAN P101 FIRST FLOOR PLAN P102 SECOND FLOOR PLAN P103 THIRD FLOOR PLAN P104 FOURTH FLOOR PLAN P105 FIFTH FLOOR PLAN P106 SIXTH FLOOR PLAN P107 SEVENTH FLOOR PLAN P108 ROOF PLAN P109 ENLARGED PLANS P110 ENLARGED PENTHOUSE PLAN MECHANICAL M001 DRAWING INDEX, SYMBOL LISTS & NOTES M002 HVAC SCHEDULES M003 HVAC SCHEDULES M100 BASEMENT FLOOR PLAN M101 FIRST FLOOR PLAN - DUCTWORK M102 SECOND FLOOR PLAN - DUCTWORK M103 THIRD FLOOR PLAN - DUCTWORK M104 FOURTH FLOOR PLAN - DUCTWORK M105 FIFTH FLOOR PLAN - DUCTWORK M106 SIXTH FLOOR PLAN - DUCTWORK M107 SEVENTH FLOOR PLAN - DUCTWORK M108 ROOF PLANS M110 ENLARGED PENTHOUSE PLANS - DUCTWORK & EQUIPMENT M200 BASEMENT FLOOR PLAN - PIPING M201 FIRST FLOOR PLAN - PIPING M202 SECOND FLOOR PLAN - PIPING M203 THIRD FLOOR PLAN - PIPING M204 FOURTH FLOOR PLAN - PIPING M205 FIFTH FLOOR PLAN - PIPING M206 SIXTH FLOOR PLAN - PIPING M207 SEVENTH FLOOR PLAN - PIPING M210 ENLARGED PENTHOUSE PLANS - PIPING M301 HVAC DUCTWORK SCHEMATICS M302 SHAFT PRESSURIZATION SCHEMATICS M303 HVAC PIPING SCHEMATIC M401 HVAC SECTIONS M402 HVAC SECTIONS M501 HVAC DETAILS M502 HVAC DETAILS M503 HVAC DETAILS ELECTRICAL E001 E002 E003 E004 E005 El 00 El 01 E102 El 03 El 04 El 05 El 06 El 07 El 08 E401 E501 E502 E503 E504 E505 E506 DRAWING INDEX, SYMBOL LISTS, AND SCHEDULES POWER OUTLET SCHEDULE, DETAILS AND DIAGRAMS LIGHTING AND CONTROL SCHEDULES DETAILS AND DIAGRAMS POWER ONE LINE DIAGRAM BASEMENT FLOOR PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN THIRD FLOOR PLAN FOURTH FLOOR PLAN FIFTH FLOOR PLAN SIXTH FLOOR PLAN SEVENTH FLOOR PLAN PENTHOUSE AND ROOF PLAN ENLARGED CORE PLANS PANELBOARD SCHEDULES - BASEMENT PANELBOARD SCHEDULES - THIRD FLOOR PANELBOARD SCHEDULES - FIFTH FLOOR PANELBOARD SCHEDULES - SEVENTH FLOOR PANELBOARD SCHEDULES - PENTHOUSE PANELBOARD SCHEDULES - PENTHOUSE 6 7 8 9 10 FIRE PROTECTION - FIT OUT FP100a BASEMENT FLOOR PLAN FP101a FIRST FLOOR PLAN •' FP102a SECOND FLOOR PLAN FP103a THIRD FLOOR PLAN FP104a FOURTH FLOOR PLAN FP105a FIFTH FLOOR PLAN FP106a SIXTH FLOOR PLAN FP107a SEVENTH FLOOR PLAN (ISSUED UNDER FUTURE FP108a ROOF PLAN FP451a STAIR ELEVATIONS - FIRE PROTECTION PIPING RISERS '== :•'.' PLUMBING - FIT OUT P100a BASEMENT FLOOR PLAN P101 a FIRST FLOOR PLAN (ISSUED UNDER FUTURE ADDENDUM) P102a SECOND FLOOR PLAN P103a THRID FLOOR PLAN P104a FOURTH FLOOR PLAN P105a FIFTH FLOOR PLAN P106a SIXTH FLOOR PLAN P107a SEVENTH FLOOR PLAN (ISSUED UNDER FUTURE P108a ROOF PLAN P109a ENLARGED PLANS MECHANICAL - FIT OUT M100a BASEMENT FLOOR PLAN - DUCTWORK M101 a FIRST FLOOR PLAN - DUCTWORK (ISSUED UNDER FUTURE M102a M103a M104a M105a M106a M107a M200a M201a M202a M203a M204a M205a M206a M207a SECOND FLOOR PLAN - DUCTWORK THIRD FLOOR PLAN - DUCTWORK FOURTH FLOOR PLAN - DUCTWORK FIFTH FLOOR PLAN - DUCTWORK SIXTH FLOOR PLAN - DUCTWORK SEVENTH FLOOR PLAN - DUCTWORK FUTURE ADDENDUM) BASEMENT FLOOR PLAN - PIPING FIRST FLOOR PLAN - PIPING SECOND FLOOR PLAN - PIPING THIRD FLOOR PLAN - PIPING FOURTH FLOOR PLAN - PIPING FIFTH FLOOR PLAN - PIPING SIXTH FLOOR PLAN - PIPING SEVENTH FLOOR PLAN - PIPING ELECTRICAL - FIT OUT E100a BASEMENT FLOOR PLAN - POWER AND COMMUNICATION E101a FIRST FLOOR PLAN - POWER AND COMMUNICATION (ISSUED UNDER FUTURE ADDENDUM) E102a SECOND FLOOR PLAN - POWER AND COMMUNICATION E103a THIRD FLOOR PLAN - POWER AND COMMUNICATION E104a FOURTH FLOOR PLAN - POWER AND COMMUNICATION E105a FIFTH FLOOR PLAN - POWER AND COMMUNICATION E106a SIXTH FLOOR PLAN - POWER AND COMMUNICATION E107a SEVENTH FLOOR PLAN - POWER AND COMMUNICATION El 08a PENTHOUSE AND ROOF PLAN - POWER AND COMMUNICATION E150a BASEMENT FLOOR PLAN - LIGHTING AND FIRE ALARM E151a FIRST FLOOR PLAN - LIGHTING AND FIRE ALARM (ISSI~ UNDER iUTURE ADDENDUM) E152a SECOND FLOOR PLAN - LIGHTING AND FIRE ALARM E153a THIRD FLOOR PLAN - LIGHTING AND FIRE ALARM E154a FOURTH FLOOR PLAN - LIGHTING AND FIRE ALARM E155a FIFTH FLOOR PLAN - LIGHTING AND FIRE ALARM E156a SIXTH FLOOR PLAN - LIGHTING AND FIRE ALARM E157a SEVENTH FLOOR PLAN - LIGHTING AND FIRE ALARM (IS UNDER FUTURE ADDENDU RECO NGS , LLC 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273/600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE ASI -08 28 OCT 2016 PR -12 03 MAY 2017 ASI -22 12 SEP 2017 CORPORATE HEADQUARTERS 0 co 0 T -w i- z Q 0 0 1< 0 U z T U- z 0 0 I- 18 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author DRAWING LIST G002 G F E D C B 2 3 4 5 6 7 8 9 10 G F E D THE DEWITT MALL C a) a) a 0 0 w COI O 2 co U) oA U a) U 4) 0 U) I- U W O 0 EXISTING ADJACENT PARKING EXISTING ADJACENT PARKING AS PER CODE A MINIMUM OF 5' CLEAR BETWEEN THE BUILDING AND PROPERTY LINE MUST BE MAINTAINED 0111M MOM 10.00' SETBACK FROM F- w w � J (Y 1- 0 O W w W O (D c z a 0 NJ EXISTING ADJACENT PARKING AS PER CODE A MINIMUM OF 10' CLEAR BETWEEN THE BUILDING AND PROPERTY LINE MUST BE MAINTAINED. PROPERTY LINE PROPERTY LINE YARD SETBAC 0 AS PER CODE A MINIMUM OF 10' CLEAR BETWEEN THE BUILDING AND PROPERTY LINE MUST BE MAINTAINED. PROPERTY LINE 2 Li -Z1 -1-1 w 15 r20 cC W 0 U) CD eD o EL z z o p N 10' REAR YARD SETBACK P 5.20' -/ 10' REAR YARD SETBACK M 0 6.47' A BUILDING FACE CRITICAL MIN. 0.40' SETBACK FROM NEW HEADQUARTERS BUILDING 1ST FLOOR PROPERTY LINE (0' FRONT YARD SETBACK) STAIR I U m 1— W U) a >- w 0 U) w z >- I w a- O HILTON GARDEN INN /1— 5.15' +1-3.18' FROM PROPERTY LINE EAST SENECA STREET AS PER CODE A MINIMUM OF 18" CLEAR BETWEEN THE SUNSHADE AND CURB LINE MUST BE MAINTAINED, GENERAL NOTES - BUILDING LOCATION 1. BUILDING LOCATED FROM PROPERTY MONUMENTS (PROPERTY PINS). 2. NO PART OF BUILDING TO PROJECT PAST SETBACKS, UNLESS SPECIFICALLY NOTED AND ALLOWED BY CITY CODE. 3. ALL DIMENSIONS FROM FROM PROPERTY LINES TO BE MAINTAINED THROUGHOUT ALL STAGES OF CONSTRUCTION. NOTIFY DESIGN TEAM OF ANY CHANGES. 4. ANY CHANGE IN ARCHITECTURAL OR STRUCTURAL FOOTPRINT OR FACADE AFTER DATE OF ISSUE TO BE CHECKED FOR CONFLICTS WITH SETBACKS. NOTIFY ARCHITECT, LANDSCAPE ARCHITECT AND CIVIL ENGINEER IMMEDIATELY OF ANY CHANGES. 5. MONUMENTS TO BE IDENTIFIED AND PRESERVED OR RELOCATED BY A LICENSED SURVEYOR. 6. GENERAL CONTRACTOR SHALL NOTIFY ALL UTILITY OWNERS HAVING UNDERGROUND UTILITIES ON SITE PRIOR TO EXCAVATION. CONTRACTOR SHALL CONTACT UTILITY LOCATING COMPANY AND LOCATE ALL UTILITIES PRIOR TO ANY EXCAVATION. 7. SEE LANDSCAPE DRAWINGS L201 FOR LAYOUT OF NON -ARCH ITECURAL SITE ELEMENTS. 8. SEE CIVIL DRAWINGS FOR LAYOUT OF UNDERGROUND UTILITIES. 9. SEE ELECTRICAL DRAWINGS FOR LAYOUT OF UNDERGROUND ELECTRICAL AND LIGHTING. 10. SITE DRAWINGS BASED ON SURVEY BY: T.G. MILLER PC 203 North Aurora Street Ithaca, NY 14850 (607) 272-6477 INTERIM VERIFICATION ONCE CONSTRUCTED, VERIFY THAT COLUMN LOCATIONS AND FOUNDATIONS MATCH CURRENT ARCHITECTURAL AND STRUCTURAL DRAWINGS. IMMEDIATELY NOTIFY ARCHITECT, LANDSCAPE ARCHITECT, AND CIVIL ENGINEER OF ANY CONFLICTS WITH SETBACKS AND LIFE SAFETY ISSUES. CONTROL POINTS HORIZONTAL CONTROL POINTS (MONUMENTS) AND ASSOCIATED COORDINATES ON THE SURVEY DATUM FOR THE SITE TO BE VERIFIED PRIOR TO CONSTRUCTION. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. LEGEND SETBACK LINE PROPERTY LINE BUILDING COLUMN LINE BUILDING FOOTPRINT (FACE OF BUILDING - FIRST FLOOR) FACE OF BUILDING ABOVE SUNSHADE OR BUILDING ENTRANCE CANOPY LINE (ALLOW TO EXTEND TO WITHIN 18" OF CURB LINE PER 170-13.E.1) 10' 20' Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 1I 'It H:\ELti LANDSCAPE ARCHITECTS 1001 W. Seneca St., Ste. 101 Ithaca, NY 14850 607-277-1400 Fax 607-277-6092 REVISION SCHEDULE NAME DATE co (f) W O Cto� D < z Q.C� O U Wim~ =Qw 0 LJJo z F_ 0F;<co -0 Et r -9 0 w U-1 �w �Oo� (1)0-; DATE: PROJECT: OTHER: DRAWN BY: 22 JANUARY 2016 2015014 BUILDING LOCATION PLAN G003 1 2 3 4 5 6 7 8 9 10 6 CO STAIR - WEST S003 SHREDDING RECYCLING 005 COIN ROOM 004 COMMON PATH - 70'-0" DEAD END - 21'-6" – COORDINATE EXTENTS WITH VESTIBULE ABOVE C■ Min= _.4... 1111111111111110 MINIM - ,�4-±-4-4---$ --)-*- �. >>>c>>>� + X4-4-4-4 > > > _ _ - MINIM _ ELEVATOR AREA OF REFUGE ELEVATOR LOBBY 001 STAIR - SOUTH 5001 AMID NO OD MINIM MO CENTRAL SUPPLY & WAREHOUSE 006 EXIT TO EXIT DISTANCE - 79'-6" DIAGONAL DISTANCE - 109'-0" EXIT ACCESS TRAVEL DISTANCE - 115'-0" MIIIMMINO---e' --- a -f-- --_ COMMUNICATIONS ROOM 002A AREA OF REFUGE GENERATOR FUEL TANK ROOM 002B --11■111110-10-4110--411110111-- COORDINATE EXTENTS WITH VESTIBULE ABOVE 0' 2' 4' 8' 16' E!) AREAWAY 7 8 9 10 NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. 1 2 3 4 5 6 7 8 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 0 co V-- Ct W 0 ("V� o w414Qz O°<ao¢ Q oLu� Qw W3a � Z �- QzQ Ct EL-- U O ZZ U -I D'_ a c(1)sli DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COMPLIANCE -B' - MENT G100 E D C B SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS (E) (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR (3) DIR COI ON O OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWINGDIRECTION DIRECTION OF EGRESS TRAVEL INDICATED BY ` > > > OR < < OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL _._._ 4— (5) REMOTENESS OF EXITS EXIT TO EXIT DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION —. s — - MOM - — MI — ® — - UMW - — (7) MINIMUM 2 HOUR CONSTRUCTION ...... .. IS MEM Ill MO Mill In SI AMINO IN INN UMW, la NO IIIIIIIIIIIIIII (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION (10) DEAD END CORRIDOR _ - - - - _ - _ (11) CONTRACT LIMIT LINE 111111111111111111111 • O • ®• O • 11111111111111110 (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED 0 1 HOUR 2 HOUR (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING O 1 HOUR 0 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. 1 2 3 4 5 6 7 8 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 0 co V-- Ct W 0 ("V� o w414Qz O°<ao¢ Q oLu� Qw W3a � Z �- QzQ Ct EL-- U O ZZ U -I D'_ a c(1)sli DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COMPLIANCE -B' - MENT G100 E D C B co 10 co ti N CN 1 2 3 4 5 6 7 8 9 8' - 9 1 /2" 01111101. 111.11111•••1111MININIMO .1•0111•11 6' - 9" 5' - 7 7/8" 7' - 7 1/4" EGRESS FRO SECOND FLOG G 5' - 10 3/4" PR -09 28 FEB 2017 • 10 NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. HLTARCHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS 26 FEB 2016 i (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR ADD.#4 20JUN2016 PR -09 28 FEB 2017 PR -09R 28 APR 2017 (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWING OF DOORS 11 5/8 DIRECTION OF EGRESS TRAVEL INDICATED BY \ `� 18' - 8" > j \ J OR < < < DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL — —>— —›-- ---)--- / .- > (5) REMOTENESS OF EXITS EXIT TO EXIT — DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION ® - MEN, - .EM - — - MEM! - _M - MINED - ..... (7) MINIMUM 2 HOUR CONSTRUCTION ___ - - MINN - - - - MEM - - NEED - - INININIM (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION ow en (10) DEAD END CORRIDOR - - - - - - - - —1 (11) CONTRACT LIMIT LINE WiNIFORD ® MIN ®41101•11111111 • OM • (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED 2 HOUR ® 1 HOUR (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING Q 1 HOUR ® 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE 'x k \< (15) EXIT DISCHARGE ® 4 4 4 , NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. HLTARCHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 ADD.#4 20JUN2016 PR -09 28 FEB 2017 PR -09R 28 APR 2017 PR -09 28 FEB 2017 63' - 6 5/8" i+ 26'-07/8" / /rte:// 0 10 CO SOUTH ELEVATION co 62' - 4 1/4" \_ OPEN ON TWO OR MORE SIDES YES /` 63' 6 0 10 CO SOUTH ELEVATION co 62' - 4 1/4" \_ OPEN ON TWO OR MORE SIDES YES /` 63' 6 5/8" 4880 SF 976 SF PROVIDED AREA OF OPENING (26'-0 7/8" x 14'-0") + (5'-11 5/8" x 14'-0") 2020 SF + (18'-8" x 14'-0") + (8'-4" x 14'-0") + (63'-6 5/8" x 14'-0") + (26'-0" x 8'-0") + (2 x (18'-8" x 2'-0")) + (10'-8" x 2'-0") 0 TOTAL PERIMETER 5' 11 5/8 i�/` 18' - 8" i% ///`' /i''// / PR -09R 28 APR 2017 WEST ELEVATION 115' - 8" NORTH ELEVATION } 136' - 4 5/8" DIAGONAL - DISTANCE - 109'-0" EXIT TO EXIT DISTANCE - 75'-0" 26' - 0" j % ■ 18' - 8" 10'-8" 18'-8" / K i Co EXIT ACCESS TRAVEL DISTANCE - 72'-0" EXIT ACCESS TRAVEL' DISTANCE - 75'-0 5' - 2 3/8" 7'-07/8" 5' - 1 3/4" EAST ELEVATION OPEN PARKING GARAGE REQUIREMENTS PER BCNYS SECTION 406.3.3.1 OPEN ON TWO OR MORE SIDES YES /` 63' 6 5/8" 4880 SF 976 SF PROVIDED AREA OF OPENING (26'-0 7/8" x 14'-0") + (5'-11 5/8" x 14'-0") 2020 SF + (18'-8" x 14'-0") + (8'-4" x 14'-0") + (63'-6 5/8" x 14'-0") + (26'-0" x 8'-0") + (2 x (18'-8" x 2'-0")) + (10'-8" x 2'-0") PERIMETER REQUIREMENT TOTAL PERIMETER REQUIRED PERIMETER REQUIRED LENGTH OF OPENING (40% OF PERIMETER LENGTH) 487.2 LF 194.9 LF PROVIDED LENGTH OF PERIMETER OPENING 26'-0 7/8" + 26'-0" + 18'-8" + 10'-8" + 18'-8" 196.6 LF + 8'-4" + 5'-11 5/8" + 63'-6 5/8" + 18'-8" NORTH ELEVATION } 136' - 4 5/8" DIAGONAL - DISTANCE - 109'-0" EXIT TO EXIT DISTANCE - 75'-0" 26' - 0" j % ■ 18' - 8" 10'-8" 18'-8" / K i Co EXIT ACCESS TRAVEL DISTANCE - 72'-0" EXIT ACCESS TRAVEL' DISTANCE - 75'-0 5' - 2 3/8" 7'-07/8" 5' - 1 3/4" EAST ELEVATION OPEN PARKING GARAGE REQUIREMENTS PER BCNYS SECTION 406.3.3.1 OPEN ON TWO OR MORE SIDES YES AREA REQUIREMENT TOTAL PERIMETER AREA REQUIRED AREA REQUIRED AREA OF OPENINGS (20% PERIMETER WALL AREA) 4880 SF 976 SF PROVIDED AREA OF OPENING (26'-0 7/8" x 14'-0") + (5'-11 5/8" x 14'-0") 2020 SF + (18'-8" x 14'-0") + (8'-4" x 14'-0") + (63'-6 5/8" x 14'-0") + (26'-0" x 8'-0") + (2 x (18'-8" x 2'-0")) + (10'-8" x 2'-0") PERIMETER REQUIREMENT TOTAL PERIMETER REQUIRED PERIMETER REQUIRED LENGTH OF OPENING (40% OF PERIMETER LENGTH) 487.2 LF 194.9 LF PROVIDED LENGTH OF PERIMETER OPENING 26'-0 7/8" + 26'-0" + 18'-8" + 10'-8" + 18'-8" 196.6 LF + 8'-4" + 5'-11 5/8" + 63'-6 5/8" + 18'-8" PARKING VENTILATION REQUIREMENTS CODE PLAN - FIRST FLOOR 1/8" = 1'-0" ALJ 0' 2' 4' 8' 1/32" = 1'-O" INOS est LLS 0 >Z O w LL O 0 tea/ Q O u j �--- U Lu U Q Z �I-^ • V, Z � U Zw -w (f) 0_w G E D C B PROJECT: OTHER: 26 FEB 2016 2015014 W N BY: uthor CODE COMPLIANCE PLAN - FIRST OR 16' 2 7 1 2 3 4 5 6 7 8 C) CHIEF INVESTMENT OFFICER 205G COO-TFA & CHIEF F. OFFICER 205F FUTURE 1RUST& ESTATE TAX MGR. 205E 0 FACILITIES & PURCHASING MANAGER 206 j FACILITIES & PURCHASING ASSOCIATE 207 STAIR - A.O.R. S202A STAIR - !NORTH COMMUNITY BANKING OFFICER 204B SVP COMMUNITY BANKING 204A ONO MUM MO STORAGE 204C • AREA OF REFUGE • •••••I BRANCH ADMINISTRATION 204 1 / CORRIDOR C200A! / CORRIDOR C200B TFA OPERATIONS DEAD END - 15'-0" CONFERENCE ROOM 203F CONFERENCE ROOM 221 203F FACILITIES L208 CO"RID •R 200 MARKETING & SALES OPERATIONS MANAGER. 205D SECURITIES ASSOCIATE 205C FUTURE LOAN OFFICER 6 201 A LOAN OFFICER 2 201B LOAN OFFICER 1 1201 C VP SALES MANAGER 201D • / 1 MAIL 202A / COFFEE / COATS SECURE FILE 202B 205B ELEC / DAT SECURE FILE 205Aa • • '. • 4• CONFERENCE ROOM 201 L ELEVATOR, LOBBY CORRIDOR C200C ELEVATOR E 200 n STAIR - SOUTH 5201 TOMPKINS INSURANCE UNASSIGNED 202C-. 202 CbPY • ,CONFERENCE ROOM 202D 202D °•% .•ice 1 111 0 ; n / CONFERENCE ROOM 201K 201K OPEN TO BELOW RETAIL SERVICES / RESIDENTIAL SALES 201 EXIT ACCESS n TRAVEL DISTANCE 128'-0" n 7 7 i \ / OPEN TO BELL 7 - 7 COMMON PATH - 30'-0" 7 7 —F — LOAN OFFICER 5 201E RESIDENTIAL) MORTGAGE LENDING OFFICER 201F FUTURE MARKETING 201G CODE PLAN - SECOND FLOOR 2 1/8" = 1'-0" COMMERCIAL SERVICES OFFICE 201 H 4 CONFERENCE ROOM 201J 1201 J 5 PL ACCOUNT EXECUTIVE 202E CNY CLAIMS 202F Ell I 0' 2' 4' 8' 16' 6 MARKETING SALES MGR 203D COMMUNITY SERVICES OFFICER 203C BANKING PRODUCT MANAGER j 203B MARKETING SALES & SERVICE DIRECTOR 203A DIAGONAL DISTANCE - 178'-0" EXIT TO EXIT DISTANCE - 62'-0" CNY CL/PL SUPERVISOR 202G 7 9 10 NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. 8 10 HOLTA CHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 CORPORATE HEADQUARTERS THACA, NEW YORK 14850 118 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COMPI CE D c B P -S O F OOR G102 SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR ` J (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWING OF DOORS DIRECTION OF EGRESS TRAVEL INDICATED BY > > OR DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL -- —- --->.— -�-- _> (5) REMOTENESS OF EXITS EXIT TO EXIT DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION Mil. • MOM NO =JIM NO r • MOM ® MM. v ®• MINIM (7) MINIMUM 2 HOUR CONSTRUCTION _ CM all ® - SD WOW - - .� - ® ® - - �® (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION so ma (10) DEAD END CORRIDOR -- - - - - —� (11) CONTRACT LIMIT LINE ®• MO • ®• MID • (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED I 1 HOUR 2 HOUR ❑ (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING O 1 HOUR @ 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE r ~ . NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. 8 10 HOLTA CHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 CORPORATE HEADQUARTERS THACA, NEW YORK 14850 118 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COMPI CE D c B P -S O F OOR G102 1 2 N CN 0 TELLER TRAINING 309 UNASSIGNED 310 VP, COMPLIANCE/BSA & SECURITY 301A SVP, COMMUNITY REINVESTMENT ACCT. 301B 6 7 STAIR A.O.R. S302A1 STAIR NORTH $302 SECONDARY MARKET COORDINATOR 302E 44•1 '40 aimmi 40- maim, AREA OF REFUGE CENTRAL BREAK ROOM TRAINING ROOM 303 DIAGONAL DISTANCE - 178'-0" KITCHEN 305 VENDING BREAK/ TRAINING ROOM STORAGE EXIT TO EXIT DISTANCE - 62'-0" 303A CORRIDOR C302 NURSING MOTHFR ELEC/DAT • 01 :, 44 • ♦'bwa SECURITY 300A WOI'N T302 CORRIDOR C303 • COMMON PATH - 38'-0" 4' -± --** .046 • •• SI w D1 COPY AREA 301 M EXIT ACCESS TRAVEL DISTANCE - 128'-0" CORPORATE RISK MANAGEMENT ^ 301 CR3 EXAMINERS ROOM 1301C CORP. COMPLIANCE ASST. MGR. 301 D FLOOR PLAN - THIRD FLOOR 1/8" = SECURITY OFFICER 301 E SECURITY MGR. 301 F CONFERENCE ROOM 301G 301G I AVP, INTERNAL AUDIT MGR. 301 H CORPORATE RISK MGR. 301J I 0' 2' 4' 8' 16' SVP, RESIDENTIAL MORTGAGE LENDING AND OPERATION MGR. 302 D RESIDENTIAL UNDERWRITING MANAGER 3020 RESIDENTIAL MORTGAGE COMPLIANCE OFFICER 302B CONFERENCE ROOM 302A I 302A CORP AUDIT ASST MGR 301L SR. CORPORATE INTERNAL AUDITOR 301K NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. 1 2 3 4 5 6 7 8 RED LeC a Con 0 9 10 2 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 CORPORATE HEADQUARTERS z 0 rt0 0 Ct 0 0 U z z (/) Z 0 O THACA, NEW YORK 14850 18 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COCE N F OOR G103 D C B A SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS E) (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR ` 1 J J (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWING OF DOORS DIRECTION OF EGRESS TRAVEL INDICATED BY \ j > 9 OR DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL 4-- > - ►— --)----->"— (5) REMOTENESS OF EXITS EXIT TO EXIT DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION ««w� m 41011100 • ®I. WIMI0 • MTh 010 MOM 00 MOM ON 0101009001 (7) MINIMUM 2 HOUR CONSTRUCTION ,-. ND s MEMO OA® =WPM 411 110 IS r MIMS m CD 001011191110110/ (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) OtOOOOOOOOOOOOOOOOOOOOOOOOOO OOOOOOOOOOOOOOOOO (9) SMOr:E PARTITION sio 4.4 (10) DEAD END CORRIDOR [*--. - - - - - - - - (11) CONTRACT LIMIT LINE 4111111111111111111D ®® i 41111111111111111111 i NMI 0 Mil= (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED 2 HOUR 0 1 HOUR ! (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING O 1 HOUR 0 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE % ti f NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. 1 2 3 4 5 6 7 8 RED LeC a Con 0 9 10 2 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 CORPORATE HEADQUARTERS z 0 rt0 0 Ct 0 0 U z z (/) Z 0 O THACA, NEW YORK 14850 18 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COCE N F OOR G103 D C B A G N 1 CHIEF TECH. OFFICER 404K IT SERVICES MANAGER 404L 2 3 IT SUPPORT SERVICES IT SYSTEMS MANAGER MANAGER 404J 404H 4 STAIR NOFI;TI1 S432 5 COMPUTER OPERATIONS MANAGER 1 404F 6 CONFERENCE1 ROOM 404E 404E 400404 STAIR A.O.R. S402A 1 4444 s 0, AREA OF REFUGE SECURE STORAGE ROOM AVP, INFORMATION SECURITY OFFICER 0 3.8 AD5A INFO. SYTEMS SECURITY ADMIN 405B • RECE VING STO GE COMPUTER OPERATIONS MANAGER 2 404D 1 APPLICATION SYSTEM MANAGER 404C BANKING SYSTEMS MANAGER 404B PRINT ROOM 404A 7 DIAGONAL DISTANCE - 178'-0" EXIT TO EXIT DISTANCE - 62'-0" COMPUTER OPERATIONS INFORMATION SECURITY MAIL ROOM C401A ELEC/DAT J.C. -401A EXIT ACCESS TRAVEL DISTANCE - 124'-0" ELEVATOR LOBBY n COMPUTER ROOM CS SUPERVISOR 406A AVP MGR. 406B CORRIDOR C401 403 n n /1 < < < < C < < < < < < < CM REMOTE BANKING CASH MANAGEMENT MANAGER 401 C 1 ATM WORK COPY / LAB COFFEE 4016 401A 1403A COMMON PATH - 54'-0" • CASH... MANAGEMENT KEE O CASH MANAGEMENT SUPERVISOR 401 D CODE PLAN - FOURTH FLOOR Al 1/8" = 1'-0" CONFERENCE ROOM 401E 3 4 401 E REMOTE ANKING ERVISOR 5 402A 8 9 10 SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS E (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT j IN THE MOST REMOTE ROOM ON THE FLOOR ' (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWING OF DOORS DIRECTION OF EGRESS TRAVEL INDICATED BY E --"- > > > OR DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL — "±-- —)— —›— > > -.> (5) REMOTENESS OF EXITS EXIT TO EXIT DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION 4410111100 • 0000 • 40610910 01111111111110 • 010040 • 4114110111 • 00040 • 011000 • (7) MINIMUM 2 HOUR CONSTRUCTION MEM ••� s••41iM••®0440-•• (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION SW UM (10) DEAD END CORRIDOR . - - - - (11) CONTRACT LIMIT LINE 111M1111111110 iD ® i 41111111111110 ! ®• (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED ® 1 HOUR 2 HOUR ® (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING 0 1 HOUR 0 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 CORPORATE HEADQUARTERS 0 L(� 0 0 U U z z Cf) z 0 0 THACA, NEW YORK 14850 118 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COMPLIANCE PLAN - F• TH F OOR F E D c B A 2 3 4 5 6 7 8 9 10 STAIR - NORTH 3/24/2016 9:52:29 PM DEPOSIT OPERATIONS ECM MANAGER MANAGER I 503F G STAIR - A.O.R. S502A COPY )6ff38FJGE ECM LEAD TECHNICIAN CONSUMER UW & LS MGR. CONSUMER LOAN ORIG. SUPERVISOR 504B ASSISTANT SYSTEMS ADMIN. 503D BANKIN OPERATIO S NORTH DEPOSIT OPERATIONS SUPERVISOR LS SUPERVISOR INTERNET BANKING MAIL / COATS / COFFEE DIAGONAL DISTANCE - 178'-0" EXIT TO EXIT DISTANCE 62'-0" NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. E REVISION SCHEDULE NAME CD Updates ADD. #2 DATE 26 FEB 2016 24 MAR 2016 CONFERENCE ROOM 504D COMMON PATH - 32`-0" ELEC/DAT LS SUPERVISOR TAXES & INSURANCE 504E SECURITY 500A IP MANAGER WORKFLOW A&P CORRIDOR ELEVATOR BANKING OPERATIONS WEST E501 ELEVATOR LOBBY^ ADJUSTER 3 MEN T50 .. R •I 0 s BANKING OPERATIONS EAST ADJUSTER 2 ARC IVAL STO'•GE 5 8 EXIT ACCESS TRAVEL DISTANCE - 130'-0" BANKING OPERATIONS SOUTH 501 C.R. MGR (I) w Z Q O O D 0- Q W U J W U F.. z QCt 0 (1)z Et O 2 ° PROJECT: OTHER: HACA, NEW YORK 14850 D c 118 E SENECA STREET, B 26 FEB 2016 2015014 DRAWN BY: Author FUTURE ADJUSTER 1 ADJUSTER 4 501A j 501 B SR. LOAN FUTURE FUTURE BUSINESS ADJUSTER 5 ADJUSTER 6 ANALYST CONFERENCE ROOM 501F SVP, BANKING BUSINESS OPERATIONS ANALYST-DEPOSI IS MGR. 501G 501 H CODE COMPLIANCE PLAN - 1F� F R A CODE PLA 1/8" = 1'-0" - FIFTH FLOOR 2 2 4 6 7 10 SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS E (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR fj (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWING OF DOORS DIRECTION OF EGRESS TRAVEL \ \ INDICATED BY E -'----- ,/ OR , / DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL -- > (5) REMOTENESS OF EXITS EXIT TO EXIT _ DIAGONAL r (6) MINIMUM 1 HOUR CONSTRUCTION ® • ® 411 M • - S IM.. MO MOM MO IMMOID IMO MOM! (7) MINIMUM 2 HOUR CONSTRUCTION mamma - w mom m • m— r „ mom ,o a . i (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION mi. 110 (10) DEAD END CORRIDOR - - `-�- - - - - (11) CONTRACT LIMIT LINE IIIIMIIIIIII • IMMO • 11111110111110 • CEID • (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED 0 1 HOUR 2 HOUR 11:1 (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING 0 1 HOUR ® 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE ;f \ NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. E REVISION SCHEDULE NAME CD Updates ADD. #2 DATE 26 FEB 2016 24 MAR 2016 CONFERENCE ROOM 504D COMMON PATH - 32`-0" ELEC/DAT LS SUPERVISOR TAXES & INSURANCE 504E SECURITY 500A IP MANAGER WORKFLOW A&P CORRIDOR ELEVATOR BANKING OPERATIONS WEST E501 ELEVATOR LOBBY^ ADJUSTER 3 MEN T50 .. R •I 0 s BANKING OPERATIONS EAST ADJUSTER 2 ARC IVAL STO'•GE 5 8 EXIT ACCESS TRAVEL DISTANCE - 130'-0" BANKING OPERATIONS SOUTH 501 C.R. MGR (I) w Z Q O O D 0- Q W U J W U F.. z QCt 0 (1)z Et O 2 ° PROJECT: OTHER: HACA, NEW YORK 14850 D c 118 E SENECA STREET, B 26 FEB 2016 2015014 DRAWN BY: Author FUTURE ADJUSTER 1 ADJUSTER 4 501A j 501 B SR. LOAN FUTURE FUTURE BUSINESS ADJUSTER 5 ADJUSTER 6 ANALYST CONFERENCE ROOM 501F SVP, BANKING BUSINESS OPERATIONS ANALYST-DEPOSI IS MGR. 501G 501 H CODE COMPLIANCE PLAN - 1F� F R A CODE PLA 1/8" = 1'-0" - FIFTH FLOOR 2 2 4 6 7 10 6 9:52:34 PM 1 2 3 4 5 6 7 8 9 10 EB ACCOUNT EXECUTIVE O 604E CL A.E. 1 604F CL A.E. 2 604G CNY WEALTH MGMT. DIR. 601A FUTURE WEALTH ADVISOR 4 601B WEALTH ADVISOR 3 601 C WEALTH ADVISOR 2 601D FINANCIAL PLANNER 601E WEALTH ADVISOR 1 601F CONFERENCE ROOM 604D 604D CNY EVP 604C 0 CL A.E. 4 6046 CL A.E. 5 604A AIR NORTH S602 SVP. SR. LOAN OFFICER 603G SVP, SR. CREDIT OFFICER 603F 4111.111 OW MM. 1 STAIR A.O.R.''? S602A IS =MOM • AREA OF REFUGE CL7 (FUTURE) 603J CORRIDOR CORRIDOR CLI 603E COMMON PATH - 40'-0" DEAD END - 14'-0" EB PRODUCER (FUTURE) CL A.E. 3 CL A.E. 6 CL2 603D CNY RKETING LOAN ADMIN. / PROCESSOR 603A CONFERENCE ROOM504N STORAGE COMMERCIAL LENDING CORRIDOR / C605 603 ELEC / DAT COPY / MAIL / COFFEE •.•ilea i• • is i 4+ �1 • t.* ++i FUTURE WEALTH ADVISOR 5 601P.L ELEVAT,4R LOBBY 600,s n ELEVATOR n MEN T601 --#•11 i !**1.6 *i ♦ �o* 1 I ; TOMPKINS FINANCIAL ST COPY 2 601 r. TOMPKINS FINANCIAL EAST 602 EXIT ACCESS TRAVEL DISTANCE - 115'-0" 1 PRES DENT TFA 601 G 0 CODE PLAN - SIXTH FLOOR FUTURE TRUST OFFICER 6 601 H TRUST OFFICER 5 601J TRUST OFFICER 4 601 K TRUST OFFICER 3 601L 1/8" = 1'-0" 3 CONFERENCE ROOM 602A 1602A �0FFICERTRUST 2 602B TRUST OFFICER 1 602C ADMIN MANAGER 602D CL3 603C EXIT TO EXIT DISTANCE - 62'-0" DIAGONAL DISTANCE - 178'-0" NOTE: - GENERIC FURNITURE I5 SHOWN FOR REFERENCE ONLY. 4 5 6 7 8 9 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 co (I) 711" Ct W 0 � o> � shall a p aQ UJo ~ = Q Li W3c t Q cin Q zQ � ZLIJ z O �w coi•-• DATE: FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author F E D c B CODE COMPLIANCE PLAN - TH A F OOR G 106 10 SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS E (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR J J J (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF OF DOORS DIRECTION OF EGRESS TRAVEL INDICATED BY % / > > > OR < < <SWING DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL --- -÷— - — > —>.--- -3-- -->--- -3 (5) REMOTENESS OF EXITS EXIT TO EXIT DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION �� • MINIM • ®• COMM I. ® • IIIMIRID p e • ■d (7) MINIMUM 2 HOUR CONSTRUCTION ,_®.. . ®... ®. ... .. _ e ...® (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION (10) DEAD END CORRIDOR - - —� — - - - - (11) CONTRACT LIMIT LINE ®• ®• MEN= • ®• tIIIIIIIIIIIIMIII (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED ® 1 HOUR D 2 HOUR (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING j O 1 HOUR OD 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVEt'` j < / NOTE: - GENERIC FURNITURE I5 SHOWN FOR REFERENCE ONLY. 4 5 6 7 8 9 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 co (I) 711" Ct W 0 � o> � shall a p aQ UJo ~ = Q Li W3c t Q cin Q zQ � ZLIJ z O �w coi•-• DATE: FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author F E D c B CODE COMPLIANCE PLAN - TH A F OOR G 106 10 1 2 3 4 FUTURE OFFICE 1 703E PRESIDENT + CEO - TTG 703F HUMAN RESOURCES OFFICE 703G CD CD PRESIDENT + CEO - TFC 703D EVP/CFO/ CORPORATE COO COUNCIL 703C 703B FUTURE OFFICE / MEETING ROOM 703A STAIR - NORTH S702 5 6 7 8 9 10 CONTROLLER CONTROLLER 2 1 ; 702F 702E •41111 STAIR - A.O.R. S702A SVP/ CHIEF ACCOUNTING OFFICER 702D AREA OF REFUGE • EXIT ACCESS TRAVEL D STANCE - 146'-0" • CORPORIrE> OFFICES > > > 703 0 U ti t RM.,/ CR4 CONF. UDITOR No, ACCOUNTING / FINANCIAL PLANNING 702 MAIUCOPY KITCHENETTE 703N ELEC / DAT SECURITY WOMEN CONFERENCE ROOM 703H ELEVATOR ELEVATOR LOBBY MEDIA CLOSET 703K j STAIR - SOUTH S701 VP, FINANCIAL PLANNING SVP, CORP ANALYST DEVELOPMENT MGt Ot"rICCR 7t2K 702L BOARD ROOM VESTIBULE SECURE FILE ROOM BO#RD ROOM 704B CONFdRENCE ROOM 701A 701A KITCHEN 704C FLOOR PLAN - SEVENTH FLOOR 1/8" = 1'-0" FUTURE H OFFICER 701B EMPLOYEE RELATIONS OFFICER 1701C 2 3 4 5 HR MANAGER 701D j HR ANALYST 701E FINANCIAL CONTROLS MANAGER 702C FINANCIAL REPORTING MANAGER 702B CR4 CONFERENCE ROOM/ FUTURE OFFICE 702A DIAGONAL DISTANCE - 178'-0" EXIT TO EXIT DISTANCE - 62'-0" COMMON PATH - 68'-0" NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. HOLTARCH1TECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 0 co co w 0 1— >- Lt < w D < 0 u.1 L1.1 Lt z I- < (/) Ct E. 0 w a. Lu ct u 0 F) co C.) I— DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COMPLIANCE PLA LOOR G107 6 10 SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS 1 (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR } (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWING OF DOORS ' DIRECTION OF EGRESS TRAVEL INDICATED BY > > > OR < < < DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL — 4— -3 (5) REMOTENESS OF EXITS EXIT TO EXIT DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION ®M,•!MI • MINIM •®•®•-•.�•MIM. (7) MINIMUM 2 HOUR CONSTRUCTION Bio • • .•• • • S • • ® • • ® • • (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION (10) DEAD END CORRIDOR )- . - _ - _ - (11) CONTRACT LIMIT LINE • ®s • a 0 — (12) COLUMN ARE PROTECTION - GYPSUM ENCLOSED � 2 HOUR ® 1 HOUR (13) COLUMN ARE PROTECTION - SPRAY APPLIED FIRE PROOFING 0 1 HOUR 0 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE ti y NOTE: - GENERIC FURNITURE IS SHOWN FOR REFERENCE ONLY. HOLTARCH1TECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE CD Updates 26 FEB 2016 ADD. #2 24 MAR 2016 0 co co w 0 1— >- Lt < w D < 0 u.1 L1.1 Lt z I- < (/) Ct E. 0 w a. Lu ct u 0 F) co C.) I— DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: Author CODE COMPLIANCE PLA LOOR G107 6 10 0_ 00 G N 0) C0 Q N 2 3 11111/110 • 4 MECHANICAL. PENTHOUSE 801 .MEM.1111 0111111110 i• 01111111110 011•1111111 OP 5 N./ No' v v v v N./ 6 Ne. > .t X v < <'v ROOF EXIT ACCESS TRAVEL DISTANCE - 154'-0" ELEVATOR. CONTROL ROOM 801 B EXIT ACCESS TRAVEL DISTANCE - 154"-0" 1 2 3 0' 2' 4' 8' 16' 14) 7 8 9 10 4 5 6 7 8 RECORD LAC e Con WINGS prices, LLC 9 10 HOLTARCHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE ADD. #2 24 MAR 2016 CORPORATE HEADQUARTERS co L.L 0 >- 0 W I- Z I V 0 Q 0 0 J U z z z 0 0 118 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: ETB CODE COMPLIANCE PLAN - : • OF G108 D c B A 2 SYMBOL ON DRAWING (IF APPLICABLE) (1) LOCATION OF EXITS (2) EXIT ACCESS TRAVEL DISTANCE: DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR (3) DIRECTION OF EGRESS TRAVEL, INCLUDING DIRECTION OF SWING OF DOORS DIRECTION OF EGRESS TRAVEL INDICATED BY \ , OR { DIRECTION OF DOOR SWING IS SHOWN GRAPHICALLY FOR EACH DOOR (4) COMMON PATH OF EGRESS TRAVEL — > > -�-- (5) REMOTENESS OF EXITS EXIT TO EXIT — i DIAGONAL (6) MINIMUM 1 HOUR CONSTRUCTION gib aMOM • OMB • MOM, Mil OMNI •IMMMII•MEMO ••®MUM (7) MINIMUM 2 HOUR CONSTRUCTION IMMOMMID Mt e MM. • • IMAM • • MMIIM • a. MISMO • • rill (8) SMOKE BARRIER (1 HOUR CONSTRUCTION) (9) SMOKE PARTITION (10) DEAD END CORRIDOR -- - - - - —� (11) CONTRACT LIMIT LINE GINOMMIND ®®• i ® i — (12) COLUMN FIRE PROTECTION - GYPSUM ENCLOSED ® 1 HOUR 2 HOUR ❑ (13) COLUMN FIRE PROTECTION - SPRAY APPLIED FIRE PROOFING 0 1 HOUR 0 2 HOUR (14) 2HR FIRE RATED FLOOR AND BEAM ASSEMBLY ABOVE 4 5 6 7 8 RECORD LAC e Con WINGS prices, LLC 9 10 HOLTARCHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE ADD. #2 24 MAR 2016 CORPORATE HEADQUARTERS co L.L 0 >- 0 W I- Z I V 0 Q 0 0 J U z z z 0 0 118 E SENECA STREET, DATE: 26 FEB 2016 PROJECT: 2015014 OTHER: DRAWN BY: ETB CODE COMPLIANCE PLAN - : • OF G108 D c B A 2 SURVEY MAP CML LEGEND NOTES EXISTING ITE CONDITIONS LJTILITY DEMOLITION PLAN SITE UTILITY N EFOSION AND SEDIMENT T LPLAN SITE UTILI1YDETAILS CIVIL/SURVEY DRAWING LIST ELECTRIC AND G : — TELEPHONE: STORM: - WATER AND SANITARY: — CABLE TELEVISION: NEW YORK STATE 'ELECTRIC D GAS DENNIS KUHN — ELECTRIC 607-347-2501 RALPH HOY — GAS 800-572-1111 VERIZON 607-734-0279 MIKE CLARK CITY- OF ITHACA STREETS AND FACILITIES 607-277-1718 RAY BENJAMIN CITYOF ITHACA WATER AND SEWER 607-272-1717 ERIK WHITNEY, P.E. TIME WARNER CABLE 607-272-3456 JEFF COLBERT UTILITY OWNERS AND CONTACTS NOT TO SCALE A.D. area drain N rrortl N.I.C. riot ire contact BLDG du€lding N.T.S. riot to scale BOP iziegirining of project NO, number CAL. caliper 0,C, on center C.l.cast irr G.D. outside diameter C.B. catch basin PE potyetrrylee C.G. cleanout PERF. perforated C.L,center lira PVC; polyvinyl chloride C°NC. concrete PCC point of con/pound clip Lire C.L.L. contract lirrrit lira 1 PC point of curvature CIDP corrugated metal pipe Pl point of inflection PRC point of reverse curvature DI drainage inlet PT point of tangent D.I. ductile iron PV1 point of Vertical intersection DIA, di meter PVT point of Vertical tangent D.S. downspout REBAR reinforce bar DAG drawing RCP reinforced concrete pipe ' R.P. radius point E' east RR railraad ELV., EL elevation= REV. revision EOP end ofproject SAN sanitary FFE firnished floor elevation ' SCH schedule FT foot Or fleet ' S south STA station GALV galvanized G.V. gas valve TEL. telephone TRANS Transite HP high point TYP. typical HDPE high density polyethylene HOR. horizontal VAR, Varies VERT, Vertical 1.D. inside dial/laterVC Vertical curve1NV invert VCT Vitrified clay the VPC Vertical print of curvature L, length (of curve) VPT vertical point of tangent LF lydar feet i VPI' Vertical point of inflectin LP low point west MH rr arrlole IVF Welded wire fabric ax um MIN. rl rrrrtrrrr It11C. miscellaneous STANDARD ABBREVIATIONS NOT TO SCALE 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 „11R, P.C. ENGINEERS AND SURVEYORS 203 NORTH AURORA CA, NEW YORK 14850 www.tgmillerpc.com 60"7-272-6477 tel. 607-273-6322 fax WARNING:; ALTERATIONS TO THIS "MAP NOT CONFORMING TO SECTION 7209, SUBDIVISION 2, NEW YORK` STATE EDUCATION LAW, ARE PROHIBITED BY LAW, ALL CERTIFICATIONS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF SAID MAP OR COPIES BEAR THE SEAL OF THE LICENSED PROFESSIONAL ENGINEER WHOSE SIGNATURE APPEARS HEREON. LOCATION NOT TO CAL PROPERTY INFORMATION SHOWN IS BASED ON MAP TITLED"BOUNDARY & TOPOGRAPHIC MAP SHOWING LANDS OF TOMPKINS TRUST COMPANY LOCATED AT NO. 118 EAST SENECA STREET" DATED 2/25/2015 BY T.G. MILLER, P.C. - TOPOGRAPHIC AND UTILITY INFORMATION SHOWN IS BASED ON MAP TITLED "BOUNDARY & TOPOGRAPHIC MAP SHOWING LANDS OF TOMPKINS TRUST COMPANY LOCATED AT NO. 118 EAST SENECA STREET" DATED 2/25/2015 BY T.G. MILLER, P.C. AS WELL AS RECENT SITE OBSERVATIONS, CITY FACILITIES MAPS, AND 1976-1977 CONSTRUCTION DOCUMENTS BY WILLIAM DOWNING ASSOCIATES ARCHITECTS AND OTHERS TITLED "TCTC DRIVE-IN FACILITY." EXISTING UTILITIES SHOWN ARE IN APPROXIMATE LOCATION ONLY. VERIFY EXACT LOCATION OF ALL UTILITIES BEFORE BEGINNING CONSTRUCTION. NOTIFY DIG SAFELY NEW YORK (D.S.N.Y. 1-800-962-7962) A MINIMUM 2 WORKING DAYS PRIOR TO BEGINNING CONSTRUCTION. - ALL DIMENSIONS TO BUILDINGS OR CURBS ARE TO EXTERIOR FACE OF BUILDING FOUNDATION WALL OR FACE OF CURB. ALL DIMENSIONS ARE PERPENDICULAR OR PARALLEL TO THE LINES FROM WHICH THEY ARE DRAWN ` UNLESS OTHERWISE NOTED. - DATUM OF ELEVATIONS IS APPROXIMATE NGVD29. CONTRACTOR TO OBTAIN PLUMBING PERMIT FROM CITY DPW (WATER AND SEWER DIVISION), PAY ALL ASSOCIATED FEES AND COMPLY WITH ALL PERMIT REQUIREMENTS. LOCATE, EXPOSE AND DOCUMENT EXACT LOCATION AND ELEVATION OF EXISTING UTILITIES AT THE CONNECTION POINTS WITH PROPOSED UTILITY IMPROVEMENTS. NOTIFY OWNER OF ANY DISCREPANCIES WITH CHARTED LOCATIONS OR ESTIMATED ELEVATIONS PRIOR TO BEGINNING INSTALLATION OF PROPOSED UTILITY IMPROVEMENTS. - ANY CONTRACTOR OR ENTITY PERFORMING UTILITY WORK WITHIN THE NYSDOT RIGHT—OF—WAY SHA OBTAIN A UTILITY WORK PERMIT FROM THE NYSDOT PRIOR TO STARTING SUCH WORK. NOT TO SCALE EX ISTING LIGHT POLE 0 EXISTING UTIUTY POLE C EXISTING GUY WIRE KLA EXISTING GAS VALVE EXISTING TRAFFIC SIGN EXISTING DRAINAGE INLET 0 EXISTING UTILITY MANHOLE -b- EXISTING FIRE HYDRANT M EXI NG WATER VALVE El EXISTING PARKING' METER PROPOSED OR IMPROVED D NAGE NLET C.O. PROPOSED CLEANOUT ' + PROPOSED 'DRYWELL � e PROPOSED GAS METER ASSEMBLY PROPERTY UNE OR STRESTREET LINE EXISTING GRADE CONTOUR EXISTING FENCE UNE EXISTING OVERH UTIES EXISTING ELECTRIC EXISTING TELECOM EXISTING GAS UNE EXISTING WATER MAIN' EXISTING SANITARY SEWER EXISTING STORM SEWER PROPOSED ELECTRIC PROPOSED TELECOM PROPOSED WATER PIPE PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED GAS UNE' DATE: PROJECT: OTHER: DRAWN BY: 26 FEB 2016 2015014 E 5-19 FLS/TRT NOT TO L C000