HomeMy WebLinkAboutDrawings_Baker Complex Kitchen RenovationsCB FP UPDNUPDNUPUPUP UP UP UP BAKER TOWER3004TBAKER SOUTH 3004SFOUNDERS HALL 3005BAKER NORTH 3004NBOLDT HALL 3006 WEST AVEUNIVERSITY AVE ALICE COOK HOUSE 3031 CARL BECKER HOUSE 3032 STEWART AVEAREA OF WORK FLORA ROSE HOUSE 3035 MENNEN HALL 3014LYON HALL 3011 BAKER TOWER -BASEMENT BAKER NORTH -GROUND FLOOR BAKER SOUTH -GROUND FLOOR AREA OF WORK AREA OF WORK B09 B08 G09 G10 G09 G10 T-000 TITLE SHEET ARCHITECTURAL A-000 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS A-101 BAKER TOWER KITCHEN DEMOLITION AND RENOVATION PLANS A-102 BAKER NORTH KITCHEN DEMOLITION AND RENOVATION PLANS A-103 BAKER SOUTH KITCHEN DEMOLITION AND RENOVATION PLANS MECHANICAL/ PLUMBING/ FIRE PROTECTION MP-001 GENERAL NOTES, SCHEDULES, AND SYMBOL LEGENDS MP-101 BAKER TOWER PARTIAL FLOOR PLANS MP-102 BAKER NORTH AND SOUTH GROUND FLOOR PARTIAL HVAC FLOOR PLANS MP-103 BAKER NORTH AND SOUTH GROUND FLOOR PARTIAL PLUMBING FLOOR PLANS ELECTRICAL E-001 GENERAL NOTES AND SYMBOL LEGENDS E-101 ELECTRICAL REMOVAL PLANS E-102 ELECTRICAL INSTALLATION PLANS E-501 PANEL SCHEDULESCORNE LL U N I V E R SI TYFOUN D E D 5681 AD CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University BAKER TOWER/ NORTH/ SOUTH BAKER COMPLEX KITCHEN RENOVATIONS T-000 11121224 TITLE SHEET FE DESIGN JGC 3004 DECEMBER 17, 2018 BAKER COMPLEX KITCHEN RENOVATIONS BUILDING CODE SUMMARYGENERAL SYMBOLS LEGEND EXTERIOR ELEVATION 1 1 1 1X-100 X-100 1 1 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE# DRAWING INDEX LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN PROJECT SCOPE PERSPECTIVE VIEW -BAKER NORTH # # KEY PLANS -BAKER TOWER, BAKER NORTH, BAKER SOUTH SITE LOCATION -BAKER COMPLEX APPLICABLE CODES 2015 (EXISTING) IBC (ADOPTED BY NEW YORK STATE) PROJECT SUMMARY THIS PROJECT INCLUDES THE RENOVATION OF 100 SF OF KITCHENS IN BAKER TOWER, BAKER NORTH, AND BAKER SOUTH. THE WORK IS ALTERATION LEVEL 2. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:2A CLASSIFICATION OF HAZARDS:NONE HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDINGS ARE SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:RESIDENTIAL (R-2) THE PURPOSE OF THIS PROJECT IS TO RENOVATE THREE KITCHENS LOCATED INSIDE OF BAKER COMPLEX 3004. WORK INCLUDES NEW FLOOR FINISHES, PAINT, CABINETS, COUNTERTOPS, AND APPLIANCES (BY OWNER). ALSO, INCLUDED IS NEW PLUMBING FIXTURES AND UPGRADED ELECTRICAL. THE LOUNGE AT BAKER TOWER WILL RECIEVE NEW FLOOR FINISH, PAINT, AND COUNTERTOP. 1 10/11/18 ISSUE FOR DD REVIEW 2 11/12/18 ISSUE FOR 95% REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION 101 A101 1 1 1 1 0 Name Elevation 101 X-X X 1t DN WALL -EXISTING WALL -METAL STUD/ GWB WALL -CONCRETE WALL -CMU WALL -BRICK ITEMS FOR DEMOLITION DOOR/ WALL -EXISTING DOOR/ WALL -NEW DOOR/ WALL -DEMOLITION TAG -DOOR TAG -WINDOW TAG -WALL TAG -ROOM # CENTER LINE PHOTO REFERENCE LEVEL MARKER COLUMN GRID MARKER ELEVATION MARKER UP ELEVATION CHANGE ARROWS BREAK LINE SYMBOLS 0' -0" ABBREVIATIONS A &AND @ AT ACT ACOUSTICAL CEILING TILE ALT ALTERNATE ALUM ALUMINUM AVG AVERAGE AFF ABOVE FINISH FLOOR B BD BOARD BLDG BUILDING BOD BOTTOM OF DECK BSMT BASEMENT C CG CORNER GUARDS CJ CONTROL JOINT CLG CEILING CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONF CONFERENCE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CRS COURSE(S) CT CERAMIC TILE D DEMO DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DO DOOR OPENING DWG DRAWING E EA EACH EJ EXPANSION JOINT ELEC ELECTRIC ELEV ELEVATION/ ELEVATOR EPDM RUBBER ROOF MEMBRANE EQ EQUAL EX'G EXISTING EXT EXTERIOR F FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FFE FINISH FLOOR ELEVATION FRP FIBER REINFORCED POLYESTER FT FOOT/FEET FTG FOOTING G GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERAL GL GLASS GWB GYPSUM WALL BOARD H HC HANDICAPPED HT HEIGHT HM HOLLOW METAL HR HOUR HVAC HEATING, VENTILATING & AC J JAN JANITOR L LAV LAVATORY LB/#POUND LGMF LIGHT GAGE METAL FRAMING M MFR MANUFACTURER MAT MATERIAL MAX MAXIMUM MEZZ MEZZANINE MIN MINIMUM MO MASONRY OPENING MTL METAL N NA NOT APPLICABLE NIC NOT IN CONTRACT NR NOT RATED NTS NOT TO SCALE O OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OSB ORIENTER STRAND BOARD P +/-PLUS OR MINUS PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED Q QTY QUANTITY R R RISER RD ROOF DRAIN REF REFRIGERATOR REQ REQUIRED REV REVISION RO ROUGH OPENING RTU ROOF TOP UNIT S SHTG SHEATHING SIM SIMILAR SF SQUARE FOOT/ FEET SS STAINLESS STEEL STL STEEL STD STANDARD T T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPERATURE TOS TOP OF STEEL TV TELEVISION TYP TYPICAL U UEV UNEVEN DOORS W/ VISION PANEL UEF UNEVEN FLUSH DOOR V VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD W W/O WITHOUT WD WOOD CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER TOWER/ NORTH/ SOUTH BAKER COMPLEX KITCHEN RENOVATIONS A-000 11121224 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS J. COOLBAUGH JGC 3004 DECEMBER 17, 2018 SCOPE OF WORK 1.0 REMOVE EXISTING CABINETS AND COUNTERTOP AND REPLACE WITH NEW ONES. 2.0 PROVIDE NEW WALL AND FLOOR FINISHES. 3.0 MODIFY EXISTING MABLE AROUND THE EXISTING WINDOW AND ADD WOOD TRIM. 4.0 INSTALL NEW OWNER SUPPLIED APPLIANCES. GENERAL NOTES 1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE, LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A ""NEW CONDITION"", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND NAME OF INSTALLER. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. 1 10/11/18 ISSUE FOR DD REVIEW 2 11/12/18 ISSUE FOR 95% REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION SUBMITTAL REGISTRY TITLE CATEGORY CASEWORK PRODUCT DATA, SHOP DRAWINGS FLOORING PRODUCT DATA GYPSUM BOARD ASSEMBLIES PRODUCT DATA GYPSUM PLASTER PRODUCT DATA INTERIOR PAINT PRODUCT DATA MILLWORK PRODUCT DATA, SHOP DRAWINGS QUARTZ COUNTERTOPS PRODUCT DATA, SHOP DRAWINGS, SAMPLES SEALANTS PRODUCT DATA SELF LEVELING UNDERLAYMENT PRODUCT DATA REF.UP REF. UP 1 23 4 5 6 7 4 4 5 SINK TO BE ABATED PRIOR TO THE START OF CONSTRUCTION UNDER SEPARATE CONTRACT. GC TO COORDINATE DEMO OF SINK WITH ABATEMENT CONTRACTOR. 4 EXISTING MARBLE TO REMAIN AT WINDOW, SEE DEMO PHOTO 6/A-101. EXISTING MARBLE TO REMAIN AT WINDOW 8 9 B09 B08 B00UB B00CA B06 B00SB B00CB A-101 5 43 2 1/2" 18 GA. G90 METAL STUDS AT 16" O.C. WITH DEFLECTION HEAD TRACK AND 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD. ATTACH TO WALLS, FLOOR, AND CEILING ABOVE WITH 1/4" x 1 1/2 WEDGE BOLTS AT 16" O.C. PROVIDE WOOD BLOCKING IN WALL WHERE BASE/ WALL CABINETS ARE TO BE LOCATED. TAPE, SPACKLE, PRIME AND PAINT (PT-1). 1 EXISTING MARBLE COUNTER TOP TO REMAIN AT WINDOW OPENING.2 3 PROVIDE NEW COUNTERTOP TO MATCH KITCHEN 2 B00CB B09 B00CA B00UB B06 B00SB B08 LVT CPT 10' - 0" +/-16' - 8" +/-14' - 9" +/-14' - 10" +/-V.I.F. 14' - 4" +/-FIN. WALL TO FACE OF STUD6' - 4 1/2"PATCH EXISTING WALLS WITH PLASTER WHERE MARBLE WAS REMOVED (TYP). PRIME AND PAINT (PT-1). PROVIDE TRANSITION STRIP AT DOOR/ EXISTING CARPET TO REMAIN. REMOVE EXISTING MARBLE PANELS (TYP). PATCH EXISTING WALLS WITH PLASTER WHERE MARBLE WAS REMOVED (TYP). PRIME AND PAINT (PT-1). EXISTING MARBLE TO REMAIN PROVIDE INSULATED METAL PANEL SCREWED TO EXISTING WINDOW WHERE DUCTWORK WAS REMOVED. SEAL AROUND OPENING WITH SEALANT. CUSTOM 18" DEEP BASE CABINETS THIS WALL ONLY. ALL OTHER CABINETS ARE FULL 24" DEPTH. PROVIDE WALL CABINETS WITHOUT DOORS (TYP) QUARTZ COUNTERTOP AND 4" BACKSPLASHNEW APPLIANCES (PROVIDED BY OWNER AND INSTALLED BY GC) PROVIDE WOOD BASE TRIM TO MATCH CABINETS AT TOE KICK . PT-1 PT-1 PT-1 PROVIDE CUSTOM FILLER PANEL AT CORNER. 1 1/4" WC-1 36" WC-4 36" WC-3 18"7/8" WC-5 30"7/8" WC-3 18" WC-2 30"1"84"30"18"36"12"7/8"SB-1 30" BC-1 18" 7/8" 30" 7/8"BC-1 18"36" BC-2 18" 1 1/4" 18" D EXISTING MARBLE TO REMAIN AT WINDOW. PROVIDE WOOD TRIM, PAINT. PT-1 PT-4 PT-3 EXISTING CAST-IN- PLACE BASE, PAINT PT-130"18"36"84"24" D 2 5/8"BC-3 18" BC-4 30"1 1/4"CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER TOWER/ NORTH/ SOUTH BAKER COMPLEX KITCHEN RENOVATIONS A-101 11121224 BAKER TOWER KITCHEN DEMOLITION AND RENOVATION PLANS J. COOLBAUGH JGC 3004 DECEMBER 17, 2018 # A-101 DEMOLITION KEY NOTES 1 REMOVE EXISTING VINYL FLOORING AND MASTIC. 2 REMOVE EXISTING ACT CEILING AND GRID. 3 REMOVE EXISTING CABINETS, COUNTERTOPS AND ALL BLOCKING. 4 REMOVE AND SALVAGE EXISTING MARBLE PANEL AND TRIM TO THE EXTENTS SHOWN ON DRAWING. TURN OVER TO OWNER 5 REMOVE EXISTING APPLIANCES. COORDINATE WITH OWNER. 6 REMOVE EXISTING DOOR. 7 REMOVE EXISTING ROLLING COUNTER DOOR. 8 REMOVE EXISTING COUNTERTOP. 9 REMOVE EXISTING CARPET IN IT'S ENTIRETY. # 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"1 DEMOLITION PLAN - TOWER BASEMENT SCALE:1/4" = 1'-0"2 RENOVATION PLAN - TOWER BASEMENT SCALE: NO SCALE 6 DEMO PHOTO SCALE: NO SCALE 5 INTERIOR ELEVATION SCALE: NO SCALE 3 INTERIOR ELEVATION SCALE: NO SCALE 4 INTERIOR ELEVATION A-101 RENOVATION KEY NOTES 1 SCRAPE LOOSE PAINT FROM UNDERSIDE OF FLOOR/ CEILING ABOVE. PREP AREA FOR PAINT. PRIME AND PAINT UNDERSIDE OF FLOOR ABOVE, CONDUIT, AND PIPING. PAINT PT-2. 2 PROVIDE NEW LVT FLOORING. 3 PROVIDE NEW CARPET TILE. GENERAL NOTES: 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO CABINET/APPLIANCE INSTALLATION NOTE MINIMUM CLEARANCE REQUIREMENTS. 2. PROVIDE FILLERS AS REQUIRED TO ALLOW PROPER CLEARANCE FOR DRAWERS, DOORS, & HARDWARE. 3. PATCH WALLS WITH LIKE MATERIALS AFTER THE REMOVAL OF EQUIPMENT, DOORS, WALLS, WINDOWS, ETC. PRIME AND PAINT. KITCHEN CABINETS AND COUNTERTOP: 1. CABINETS -DURA SUPREME -CRESTWOOD HUDSON DOOR IN OAK • ALL PLYWOOD CONSTRUCTION, SOLID HARDWOOD DOVETAILED DRAWERS • SOFT CLOSE HINGES AND FULL EXTENSION, SOFT CLOSE DRAWER TRACKS BY BLUM • PROVIDE UPPER CABINETS WITHOUT DOORS • HARDWARE -LIBERTY 3/4" X 3" STEEL BAR PULL, BRUSHED STAINLESS STEEL FINISH • 5-10 YEAR WARRANTY • FULLY SEALED FINISH 2. COUNTERTOPS -CORIAN QUARTZ BY DUPONT, • 1 1/8 THICK WITH FULL BULLNOSE EDGE • 4" BACKSPLASH & SIDESPLASH • COLOR: AS SELECTED FROM FULL LINE COLOR CHART PAINT: PT-1 -WALL PAINT -BENJAMIN MOORE, ECOSPEC -COLOR (TBD BY OWNER) PT-2 -CEILING PAINT -BENJAMIN MOORE, ECOSPEC -COLOR (TBD BY OWNER) PT-3 - DOOR FRAMES -BENJAMIN MOORE, ECOSPEC -COLOR (TBD BY OWNER) PT-4 -EXISTING WALL BASE -BENJAMIN MOORE, ECOSPEC -COLOR (TBD BY OWNER) CASEWORK SCHEDULE MARK WIDTH HEIGHT DEPTH MANUFACTURER (N) GROUND FLOOR BC-5 1' - 6" 2' - 8 3/4" 2' - 0" DURASUPREME BC-6 1' - 3" 2' - 8 3/4" 2' - 0" DURASUPREME SB-2 2' - 6" 2' - 8 3/4" 2' - 0" DURASUPREME WC-2 2' - 6" 2' - 6" 1' - 0" DURASUPREME WC-3 1' - 6" 2' - 6" 1' - 0" DURASUPREME WC-4 3' - 0" 1' - 0" 2' - 0" DURASUPREME WC-5 2' - 6" 1' - 0" 1' - 0" DURASUPREME (S) GROUND FLOOR BC-5 1' - 6" 2' - 8 3/4" 2' - 0" DURASUPREME BC-6 1' - 3" 2' - 8 3/4" 2' - 0" DURASUPREME SB-2 2' - 6" 2' - 8 3/4" 2' - 0" DURASUPREME WC-2 2' - 6" 2' - 6" 1' - 0" DURASUPREME WC-3 1' - 6" 2' - 6" 1' - 0" DURASUPREME WC-4 3' - 0" 1' - 0" 2' - 0" DURASUPREME WC-5 2' - 6" 1' - 0" 1' - 0" DURASUPREME (T) BASEMENT BC-1 1' - 6" 2' - 10 7/8" 2' - 0" DURASUPREME BC-2 1' - 6" 2' - 10 7/8" 2' - 0" DURASUPREME BC-3 1' - 6" 2' - 10 7/8" 1' - 6" DURASUPREME BC-4 2' - 6" 2' - 10 7/8" 1' - 6" DURASUPREME SB-1 2' - 6" 2' - 10 7/8" 2' - 0" DURASUPREME WC-1 3' - 0" 2' - 6" 1' - 0" DURASUPREME WC-2 2' - 6" 2' - 6" 1' - 0" DURASUPREME WC-3 1' - 6" 2' - 6" 1' - 0" DURASUPREME WC-4 3' - 0" 1' - 0" 2' - 0" DURASUPREME WC-5 2' - 6" 1' - 0" 1' - 0" DURASUPREME FLOORING: 1. PROVIDE ARDEX LU 100 SELF LEVELING UNDERLAYMENT MANNINGTON PLANK: • NATURES PATHS -#12237 MADISON MAPLE PEPPER BARK 6" X 36" PLANK INTERFACE CARPET TILE: • MONOCHROME CARPET TILE (MAIN COLOR -TBD BY OWNER) • MONOCHROME CARPET TILE (BOARDER COLOR -TBD BY OWNER) 1 10/11/18 ISSUE FOR DD REVIEW 2 11/12/18 ISSUE FOR 95% REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION REF.A-102 3 2 1 LVTEX. CPT RELOCATED VENDING MACHINE, COORDINATE WITH CIT FOR CONNECTIONS FIN. EX. WALL TO F.O. STUDS 6' - 7" +/-25' - 0" +/-(N) G10 (N) G08 (N) G09 PROVIDE 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD ATTACHED TO EXISTING STUD WALL. PROVIDE WOOD BLOCKING IN WALL WHERE BASE/ WALL CABINETS ARE TO BE LOCATED. TAPE, SPACKLE, PRIME AND PAINT (PT-1). PROVIDE TRANSITION STRIP EXISTING MARBLE TO REMAIN AT WINDOW. (N) G08 (N) G10 (N) G09 1 EXISTING CASEWORK AND FLOORING TO BE DEMOED (IN THIS AREA) AS PART OF BATHROOM RENOVATION PROJECT (UNDER A DIFFERENT CONTRACT) PRIOR TO THE START OF THIS PROJECT. PROVIDE TEMPORARY CONSTRUCTION PARTITION WITH DOOR PRIOR TO START OF KITCHEN RENOVATION 25' - 0" +/-BC-6 15" CLEAR 36" BC-6 15" V.I.F. 33" +/- BC-5 18" SB-2 30" BC-5 18" 1 1/2" +/- WC-5 30" 1 1/2" +/- WC-3 18" WC-2 30" WC-3 18" 3/4" WC-4 36"3/4" PROVIDE CUSTOM END CLOSURE PANEL. QUARTZ COUNTERTOP WITH FULL BULLNOSE AND 4" BACKSPLASH. PROVIDE BRACKETS AT OPEN AREA. NEW APPLIANCES (PROVIDED BY OWNER AND INSTALLED BY GC) PROVIDE WOOD BASE TRIM TO MATCH CABINETS AT TOE KICK . PT-1 PROVIDE CUSTOM TOE KICK/ FILLER PANEL AT STOVE.30"20"84"RELOCATED VENDING MACHINE, COORDINATE WITH CIT FOR CONNECTIONS MIN.27"WALL BASE (BEYOND) WALL BASE TO MATCH EXISTING PROVIDE CUSTOM WOOD VALANCE. COLOR AND WOOD TYPE TO MATCH CABINETS. ATTACHED TO EACH SIDE WITH ANGLE BRACKETS. PROVIDE ADA SINK BASE CABINET CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER TOWER/ NORTH/ SOUTH BAKER COMPLEX KITCHEN RENOVATIONS A-102 11121224 BAKER NORTH KITCHEN DEMOLITION AND RENOVATION PLANS J. COOLBAUGH JGC 3004 DECEMBER 17, 2018 SCALE: 1/4" = 1'-0" 2 RENOVATION PLAN - NORTH GROUND FLOOR SCALE: 1/4" = 1'-0" 1 DEMOLITION PLAN - NORTH GROUND FLOOR A-102 DEMOLITION KEY NOTES 1 REMOVE EXISTING GYPSUM WALL BOARD. EXISTING STUDS TO REMAIN. REVIEW CONDITION OF EXISTING STUDS, IF RUSTED OR ROTTED, PROVIDE NEW G90 STUDS TO MATCH EXISTING. SCALE: 1/4" = 1'-0" 3 INTERIOR ELEVATION A-102 RENOVATION KEY NOTES 1 SCRAPE LOOSE PAINT FROM UNDERSIDE OF FLOOR/ CEILING ABOVE. PREP AREA FOR PAINT. PRIME AND PAINT UNDERSIDE OF FLOOR ABOVE, CONDUIT, AND PIPING. PAINT PT-2. 2 PROVIDE NEW PLANK FLOORING. REFER TO A-101 FOR SPEC. 0' 2' 4' 8' SCALE: 1/4"=1'-0" # # 1 10/11/18 ISSUE FOR DD REVIEW 2 11/12/18 ISSUE FOR 95% REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION GENERAL NOTES: 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO CABINET/APPLIANCE INSTALLATION NOTE MINIMUM CLEARANCE REQUIREMENTS. 2. PROVIDE FILLERS AS REQUIRED TO ALLOW PROPER CLEARANCE FOR DRAWERS, DOORS, & HARDWARE. 3. PATCH WALLS WITH LIKE MATERIALS AFTER THE REMOVAL OF EQUIPMENT, DOORS, WALLS, WINDOWS, ETC. PRIME AND PAINT. 4. REFER TO A-101 FOR SPECIFICATION INFORMATION. REF.EXISTING MARBLE TO REMAIN AT WINDOW. 1 (S) G08 (S) G10 (S) G09 EXISTING CASEWORK AND FLOORING TO BE DEMOED (IN THIS AREA) AS PART OF BATHROOM RENOVATION PROJECT (UNDER A DIFFERENT CONTRACT) PRIOR TO THE START OF THIS PROJECT. PROVIDE TEMPORARY CONSTRUCTION PARTITION WITH DOOR PRIOR TO START OF KITCHEN RENOVATION 25' - 6" +/-A-102 3 SIM PROVIDE 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD ATTACHED TO EXISTING STUD WALL. PROVIDE WOOD BLOCKING IN WALL WHERE BASE/ WALL CABINETS ARE TO BE LOCATED. TAPE, SPACKLE, PRIME AND PAINT (PT-1). 2 1 FIN. EX. WALL TO F.O. STUDS 6' - 5" +/-25' - 6" +/-LVTEX. CPT RELOCATED VENDING MACHINE, COORDINATE WITH CIT FOR CONNECTIONS (S) G10 (S) G08 (S) G09 PROVIDE TRANSITION STRIP CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER TOWER/ NORTH/ SOUTH BAKER COMPLEX KITCHEN RENOVATIONS A-103 11121224 BAKER SOUTH KITCHEN DEMOLITION AND RENOVATION PLANS J. COOLBAUGH JGC 3004 DECEMBER 17, 2018 SCALE:1/4" = 1'-0"1 DEMOLITION PLAN - SOUTH GROUND FLOOR SCALE: 1/4" = 1'-0" 2 RENOVATION PLAN - SOUTH GROUND FLOOR A-103 DEMOLITION KEY NOTES 1 REMOVE EXISTING GYPSUM WALL BOARD. EXISTING STUDS TO REMAIN. REVIEW CONDITION OF EXISTING STUDS, IF RUSTED OR ROTTED, PROVIDE NEW G90 STUDS TO MATCH EXISTING. A-103 RENOVATION KEY NOTES 1 SCRAPE LOOSE PAINT FROM UNDERSIDE OF FLOOR/ CEILING ABOVE. PREP AREA FOR PAINT. PRIME AND PAINT UNDERSIDE OF FLOOR ABOVE, CONDUIT, AND PIPING. PAINT PT-2. 2 PROVIDE NEW PLANK FLOORING. REFER TO A-101 FOR SPEC. 0' 2' 4' 8' SCALE: 1/4"=1'-0" # # 1 10/11/18 ISSUE FOR DD REVIEW 2 11/12/18 ISSUE FOR 95% REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION GENERAL NOTES: 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO CABINET/APPLIANCE INSTALLATION NOTE MINIMUM CLEARANCE REQUIREMENTS. 2. PROVIDE FILLERS AS REQUIRED TO ALLOW PROPER CLEARANCE FOR DRAWERS, DOORS, & HARDWARE. 3. PATCH WALLS WITH LIKE MATERIALS AFTER THE REMOVAL OF EQUIPMENT, DOORS, WALLS, WINDOWS, ETC. PRIME AND PAINT. 4. REFER TO A-101 FOR SPECIFICATION INFORMATION. (T) BASEMENT 686' -0" (N) GROUND FLOOR 677' -0" (S) GROUND FLOOR 685' -0" 3/4" HHWS TO WITHIN WALL 3/4" HHWR TO WITHIN WALL CONNECT TO EXISTING HHWS AND HHWR 3/4" HHWS AND HHWR TO WITHIN WALL CAVITY BALANCING VALVE BV-1 FCU-G09 CONTROL VALVE CV-G09 SUPPLY RETURN BALL VALVE V-1 (TYP. OF 2) BALANCING VALVE PRESSURE/TEMPERATURE TEST PORT (TYP. OF 2) MANUAL AIR VENT COIL STRAINER BLOWDOWN WITH BRASS HOSE CONNECTION, CAP WITH CHAIN COIL DRAIN WITH BRASS HOSE CONNECTION, CAP AND CHAIN (TYP.)CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.IPP.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER COMPLEX BAKER COMPLEX KITCHEN RENOVATIONS MP-001 11121224 GENERAL NOTES, SCHEDULES, AND SYMBOL LEGENDS T. FISHER TRF 3004 December 17, 2018 MECHANICAL ABBREVIATIONS CO CLEAN OUT CD CONDENSATE DRAIN DHWS DOMESTIC COLD WATER SUPPLY DHWR DOMESTIC HOT WATER RETURN DCWR DOMESTIC HOT WATER SUPPLY FTR FIN TUBE RADIATION FP FIRE PROTECTION HHWR HEATING HOT WATER RETURN HHWS HEATING HOT WATER SUPPLY PF PLUMBING FIXTURE SAN SANITARY V VENT WCO WALL CLEANOUT MECHANICAL SYMBOLOGY 2-WAY ELECTRIC CONTROL VALVE 3-WAY ELECTRIC CONTROL VALVE ACOUSTICALLY ALIGNED DUCTWORK AIRFLOW AQUA STAT AUTOMATIC LOUVERED DAMPER IN DUCT BACKFLOW PREVENTER BALANCE VALVE BALL VALVE BOTTOM PIPE CONNECTION BUTTERFLY VALVE CAP OR PLUG CHECK VALVE CIRCULATING PUMP DIRECTION OF FLOW DUCT AIRFLOW DUCT DOWN (EXHAUST OR RETURN) DUCT DOWN (SUPPLY) DUCT UP (EXHAUST OR RETURN) DUCT UP (SUPPLY) EXHAUST FAN EXHAUST OR RETURN UP THROUGH NEXT FLOOR OR ROOF EXPANSION COMPENSATOR WITH EXPANSION GUIDES EXPANSION JOINT FIRE AND SMOKE DAMPER IN DUCT FIRE DAMPER IN DUCT FLANGE CONNECTION FLEX CONNECTOR FLEXIBLE CONNECTION FLEXIBLE DUCT FLOW METER FLOW SWITCH FUSIBLE LINK VALVE GLOBE VALVE MANUAL AIRVENT ORIFICE METER PIPE ANCHOR PIPE DOWN PIPE GUIDE PIPE UP PIPING REDUCER (CONCENTRIC) PIPING REDUCER (ECCENTRIC) PITCH PIPING (DOWN) PRESSURE GAUGE PRESSURE OR TEMPERATURE PETES PLUG PRESSURE REDUCING VALVE PRESSURE SWITCH RECTANGULAR ELBOW RECTANGULAR ELBOW WITH TURNING VANES RELIEF VALVE ROOF TOP HOOD SMOKE DAMPER IN DUCT SOLENOID VALVE STANDARD BRANCH DUCT STEAM TRAP STRAINER (DUPLEX) STRAINER WITH BLOWDOWN VALVE AND CAP SUPPLY THROUGH NEXT FLOOR OR ROOF TEMPERATURE WELL THERMOMETER THERMOMETER (DIAL) TOP PIPE CONNECTION TRIPLE DUTY VALVE UNION CONNECTION VACUUM BREAKER VOLUME DAMPER IN DUCT GENERAL DRAWING SYMBOLOGY DEMOLISHED WORK EXISTING PIPING TO REMAIN EXISTING TO REMAIN EXISTING WORK TO REMAIN NEW WORK POINT OF CONNECTION POINT OF DISCONNECTION PLUMBING FIXTURE SCHEDULE & SPEC TAG DESCRIPTION BOD MANUFACTURER MODEL DIMENSIONS MATERIAL FINISH / COLOR COLD WATER HOT WATER WASTE / SANITARY VENT NOTES STANDARDS PF-1 SINK - UNDERMOUNT ELKAY ECTSRAD25226BG 25" X 22" X 6" 304 STAINLESS STEEL POLISHED SATIN 1-1/2" 1-1/4" MINIMUM CABINET SIZE 36"ADA COMPLIANT FAUCET - DECK MOUNT MOEN CA87003RS N/A METAL STAINLESS 1/2" 1/2"SINGLE HANDLE, 3/8" COMPRESSION FITTING CONNECTIONS ADA COMPLIANT SUPPLIES - ANGLE (LOOSE KEY) T&S BRASS B-1335 1/2" NPT INLET BRASS CHROME 1/2" 1/2"COORDINATE OUTLET CONNECTION WITH FAUCET DRAIN ASSEMBLY DAYTON D1125 3-1/2" DIAMETER STAINLESS STEEL MATTE 1-1/2" GRID DRAIN WITH REMOVABLE STRAINER MECHANICAL/PLUMBING/FIRE PROTECTION PIPE AND FITTING SCHEDULE AND SPECIFICATIONS PIPE SERVICE ABBREVIATION PIPE SIZE MATERIAL FITTINGS JOINT INSULATION DOMESTIC WATER DCWS / DHWS 1-1/2" & BELOW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1/2" THICK FIBERGLASS, K=0.27 (MAX) WITH VAPOR RETARDER SANITARY DRAIN AND VENT SAN / V 2" & BELOW ASTM B306 DWV COPPER ASME B16.29 TYPE DWV WROUGHT COPPER ASTM B32 SOLDER N/A SANITARY DRAIN AND VENT SAN / V 2-1/2" & ABOVE ASTM A74, ASTM A888 SERVICE WEIGHT CAST IRON ASTM A74, ASTM A888 CAST IRON NO-HUB ASTM C1277 NEOPRENE GASKET SS BANDS N/A HEATING HOT WATER HWS/HWR 1-1/4" & BELOW ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1-1/2" THICK FIBERGLASS, K=0.29 (MAX) WITH VAPOR RETARDER DRY SPRINKLER DSP 2" & SMALLER ASTM A53, A135 OR A795 STEEL, SCH 40 BLACK ASME B16.3 MALLEABLE IRON, CLASS 125 AND 300 THREADED N/A MECH/PLUMBING/FP SCOPE OF WORK 1.0 PROVIDE PLUMBING, MECHANICAL, AND FIRE PROTECTION SYSTEM MODIFICATIONS AS REQUIRED TO SUPPORT THE RENOVATION OF THE NORTH, SOUTH, AND TOWER KITCHENS AT THE BAKER COMPLEX. 2.0 TOWER - DEMOLITION OF EXISTING EXHAUST FAN, DUCTWORK, GRILLE, AND ACCESSORIES. 3.0 TOWER/NORTH/SOUTH - SELECTIVE DEMOLITION OF EXISTING DOMESTIC WATER AND SANITARY DRAIN/VENT PIPING. 4.0 TOWER/NORTH/SOUTH - PROVIDE KITCHEN SINK, FAUCET, AND ACCESSORIES. 5.0 TOWER/NORTH/SOUTH - PROVIDE DOMESTIC WATER AND SANITARY DRAIN PIPING AS REQUIRED TO CONNECT SINK TO EXISTING SERVICES. 6.0 NORTH/SOUTH - DEMOLITION OF EXISTING FIN-TUBE, PIPING, VALVE, AND ACCESSORIES. 7.0 NORTH/SOUTH - PROVIDE FIN TUBE, ENCLOSURE, TEMPERATURE CONTROL, HEATING HOT WATER SUPPLY/RETURN PIPING, AND ACCESSORIES. 8.0 TOWER - DISCONNECT AND REMOVE SPECIFIED SPRINKLERS AND PIPING AS REQUIRED TO PROVIDE PROPER SPRINKLER PROTECTION DUE TO CEILING REMOVAL. 9.0 NORTH/SOUTH - TEST AND BALANCE HYDRONIC SYSTEM ASSOCIATED WITH NEW FIN-TUBE RADIATION, SUBMIT REPORT. MECHANICAL/PLUMBING GENERAL NOTES 1.0 DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. IF DIMENSIONS OR CONDITIONS ARE FOUND TO BE IN CONFLICT WITH THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY REFER THE CONFLICT TO THE ENGINEER. 2.0 UTILITY SHUTDOWNS: SHUTDOWN OF ANY BUILDING UTILITY SYSTEM SHALL BE COORDINATED WITH CUSTOMER SERVICE AT PH: 607-255-5322. THE CONTRACTOR SHALL BEAR THE COST OF THE UTILITY SHUTDOWN. SCHEDULE WORK TEN DAYS IN ADVANCE AND NOTIFY THE OWNER'S REPRESENTATIVE TO COORDINATE BUILDING FUNCTIONS WITH THE BUILDING COORDINATOR. 3.0 ALL PENETRATIONS THROUGH FULL HEIGHT WALLS ARE TO BE FIRESTOPPED IN ACCORDANCE WITH UL STANDARDS. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS ARE TO BE FIRE AND SMOKE STOPPED. CAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRESTOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. 4.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 5.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION, FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY. 6.0 VERIFY FINAL EQUIPMENT/FIXTURE LOCATIONS FOR ROUGHING-IN. 7.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. 8.0 CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, AND PATCHING TO COMPLETE THE WORK. WHERE EXISTING CONSTRUCTION IS REMOVED, CAUSING AN EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES, RESULTING SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. FIRE PROTECTION GENERAL NOTES 1.0 IT IS THE INTENT OF THESE DRAWINGS TO PROVIDE MODIFICATIONS TO THE EXISTING DRY-PIPE FIRE PROTECTION SYSTEM FOR THE PROTECTION OF THE BAKER TOWER B08 SPACE RENOVATIONS. 2.0 PRIOR TO ALTERATIONS, THE SPRINKLER CONTRACTOR SHALL FIELD VERIFY EXTENT OF ALTERATION AND NEW WORK, WITH REGARD TO EXISTING CONDITIONS AT PIPE PENETRATIONS THROUGH FLOORS, WALLS, CEILINGS AND SOFFITS. 3.0 ALL SPRINKLER COMPONENTS SHALL BE UNDERWRITER'S LABORATORIES (UL) AND FACTORY MUTUAL (FM) APPROVED. 4.0 THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE GENERAL ARRANGEMENT OF THE ITEMS INCLUDED IN THE FIRE PROTECTION WORK. AS SUCH, CONTRACTOR SHALL PROVIDE A COMPLETE SPRINKLER SYSTEM IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF FM GLOBAL STANDARDS, THE NFPA 13-INSTALLATION OF FIRE PROTECTION SYSTEMS, THE NEW YORK STATE BUILDING CODES, THE NEW YORK STATE FIRE CODES, LOCAL CODES, AND GOVERNING AUTHORITIES. THE DESIGN OF FIRE PROTECTION SYSTEMS TO WITHSTAND SEISMIC EVENTS SHALL BE IN ACCORDANCE WITH THE CRITERIA DEVELOPED BY THE NFPA. 5.0 SPRINKLER COVERAGE OR HEAT DETECTION SHALL BE MAINTAINED AT ALL TIMES DURING THE RENOVATION. CONTRACTOR SHALL REQUEST SPRINKLER SYSTEM SHUTDOWNS WITH THE BUILDING COORDINATOR A MINIMUM OF TEN (10) DAYS PRIOR TO THE SHUTDOWN DATE. THE CONTRACTOR SHALL BEAR THE COST OF THE UTILITY SHUTDOWN. NOTIFY THE OWNER'S REPRESENTATIVE TO COORDINATE BUILDING FUNCTIONS WITH THE BUILDING COORDINATOR. 6.0 COORDINATE THE EXACT LOCATION OF SPRINKLERS, EQUIPMENT, AND DEVICES WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND ALL OTHER TRADES DRAWINGS PRIOR TO ROUGH-IN AND INSTALLATION. 7.0 SPRINKLER PIPING SHALL BE ARRANGED TO DRAIN THROUGH THE MAIN DRAIN VALVE WHENEVER PRACTICAL. ALL TRAPPED SECTIONS OF PIPE, EXCEPT THOSE SUPPLYING A SINGLE SPRINKLER, SHALL BE PROVIDED WITH A DRUM-DRIP ASSEMBLY. 8.0 PENETRATIONS THROUGH CONCRETE FLOORS AND WALLS SHALL BE MADE WITH GALVANIZED PIPE SLEEVES. ALL PENETRATIONS SHALL CONTAIN FIRE STOPPING WITH A FIRE RATING EQUAL TO THAT OF THE AREA BEING PENETRATED. 9.0 SPRINKLER PIPING SHALL BE LABELED. 10.0 AFTER ALL WORK HAS BEEN COMPLETED, ACCEPTANCE TESTING SHALL BE SCHEDULED THROUGH EH&S, AND SHALL BE WITNESSED BY EH&S AND CITY OF ITHACA REPRESENTATIVES. 11.0 AIR TEST SHALL BE AT SYSTEM OPERATING PRESSURE, FOR A PERIOD OF 24-HOURS. 12.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. SPRINKLER SCHEDULE SPRINKLER TYPE SERVES MANF BOD MODEL BOD (SIN) RESPONSE ORIFICE (IN) K-FACTOR TEMPERATURE RATING (DEG F)CONSTRUCTION FINISH UPRIGHT KITCHEN B08 RELIABLE F1FR-56 (RA1425) QUICK 1/2 5.6 155 BRASS BRONZE 1 SOLDER FILLER METALS: ASTM B32, LEAD-FREE ALLOYS. INCLUDE WATER FLUSHABLE FLUX ACCORDING TO ASTM B813. 2 PIPE NIPPLES: SAME QUALITY, MATERIAL, CLASS AS PIPING. CLOSE NIPPLES ARE NOT PERMITTED. 3 INSTALL PLUMBING SYSTEMS TO FACILITATE SERVICE, MAINTENANCE AND REPAIR OR REPLACEMENT OF COMPONENTS. 4 USE APPROVED FITTINGS TO MAKE CHANGES IN DIRECTION, BRANCH TAKEOFFS FROM MAINS, AND REDUCTIONS IN PIPE SIZE. 5 PROVIDE DRAINS FOR COMPLETE SPRINKLER SYSTEM DRAINAGE, PER NFPA. 6 ALL WASTE PIPING SHALL BE PITCHED AT 1/8" PER FOOT. ALL SUPPLY PIPING SHALL BE PITCHED BACK TOWARDS CONNECTION TO THE ROOM ENTRANCE. 7 PROVIDE VAPOR RETARDER ON PIPING INSULATION SYSTEMS CARRYING FLUIDS WITH AN OPERATING TEMPERATURE LOWER THAN 60 DEGREES F. 8 DO NOT ENCLOSE, COVER OR PUT PLUMBING PIPING SYSTEMS INTO OPERATION UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE AUTHORITIES HAVING JURISDICTION. 9 LEAVE NEW, ALTERED, EXTENDED, OR REPLACED DOMESTIC WATER PIPING UNCOVERED AND UNCONCEALED UNTIL IT HAS BEEN TESTED. EXPOSE WORK THAT WAS COVERED OR CONCEALED BEFORE IT WAS TESTED. 10 PROVIDE PIPE LABLES AND DIRECTIONAL ARROWS ON ALL NEW PIPING SYSTEMS. LABELS SHALL BE PRINTED PLASTIC WITH CONTACT-TYPE, PERMANENT ADHESIVE BACKING. LETTERS SHALL BE 1/4-INCH. 11 PAINT ALL UNINSULATED PIPING, WHEN EXPOSED TO VIEW. 12 ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 13 TESTING OF DOMESTIC WATER PIPING: CAP AND SUBJECT DOMESTIC WATER PIPING TO STATIC WATER PRESSURE OF 50 PSIG ABOVE OPERATING PRESSURE, WITHOUT EXCEEDING PRESSURE RATING OF PIPING SYSTEM MATERIALS ISOLATE TEST SOURCE AND ALLOW TO STAND FOR FOUR HOURS. LEAKS AND LOSS IN TEST PRESSURE CONSTITUTE DEFECTS THAT MUST BE REPAIRED REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED. 14 TESTING OF DOMESTIC WASTE AND VENT PIPING: CAP AND SUBJECT DOMESTIC WASTE AND VENT PIPING TO STATIC WATER PRESSURE OF 10 FEET HEAD PRESSURE ABOVE HIGHEST POINT OF SYSTEM UNDERGOING TEST ISOLATE TEST SOURCE AND ALLOW TO STAND UNTIL SYSTEM CAN BE VISUALLY INSPECTED BY AUTHORITY HAVING JURISDICTION. LEAKS CONSTITUTE DEFECTS THAT MUST BE REPAIRED REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED. 15 TESTING OF HYDRONIC SYSTEMS: FILL SYSTEM WITH AMBIENT TEMPERATURE WATER. USE VENTS INSTALLED AT HIGH POINTS OF SYSTEM TO RELEASE AIR. USE DRAINS INSTALLED AT LOW POINTS FOR COMPLETE DRAINING OF TEST LIQUID. ISOLATE EXPANSION TANKS AND DETERMINE THAT HYDRONIC SYSTEM IS FULL OF WATER SUBJECT PIPING SYSTEM TO HYDROSTATIC TEST PRESSURE THAT IS NOT LESS THAN 1.5 TIMES THE SYSTEM WORKING PRESSURE. TEST PRESSURE SHALL NOT EXCEED MAXIMUM AFTER HYDROSTATIC TEST PRESSURE HAS BEEN APPLIED FOR AT LEAST 10 MINUTES, EXAMINE PIPING, JOINTS, AND CONNECTIONS FOR LEAKAGE. ELIMINATE LEAKS BY TIGHTENING, REPAIRING, OR REPLACING COMPONENTS, AND REPEAT HYDROSTATIC TEST UNTIL THERE ARE NO LEAKS. ARRANGE FOR INSPECTION BY FACILITIES MANAGEMENT PIPE SHOP. SCALE:1/2" = 1'-0"1 FINTUBE RADIATION ELEVATION 1 10/10/18 ISSUE FOR 50% DD REVIEW 2 11/12/18 ISSUE FOR 95% CD REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION CONTROL VALVE SCHEDULE & SPEC TAG MANF VALVE MODEL OPERATOR MODEL SIZE (IN) CV CAPACITY (GPM) MAX PD (PSIG) TYPE CV-G09S BELIMO CCV - B210 SGF24 1/2 1.9 0 - 2.6 4 2-WAY, PROPORTIONAL, SPRING RETURN CV-G09N BELIMO CCV - B210 SGF24 1/2 1.9 0 - 2.6 4 2-WAY, PROPORTIONAL, SPRING RETURN 1 ACCEPTABLE MANUFACTURERS: BELIMO, VSI 2 ELECTRIC INPUT: 0-10VDC 3 TWO-WAY VALVES: EQUAL PERCENTAGE FLOW CHARACTERISTIC 4 CONSTRUCTION: CHARACTERIZING DISK, FORGED BRASS, NICKEL PLATED BODY, STAINLESS STEEL BALL AND STEM, FIBERGLASS REINFORCED PTFE SEAT 5 RATINGS: 400 PSI PRESSURE, 0-212 F MEDIA TEMPERATURE RANGE 6 ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. CONTROL WIRING SHALL BE UNSPLICED FROM THE CONTROLLER TO THE SENSOR OR DEVICE. TEST EACH POINT THROUGH IT FULL OPERATING RANGE TO VERIFY THAT SAFETY AND OPERATING CONTROL SET POINTS ARE AS REQUIRED. 7 PROVIDE WITH ENCLOSURE MOUNTED POSITIONER (OPERATOR) PIPING ACCESSORIES SCHEDULE AND SPECIFICATIONS TAG DEVICE BOD MANUFACTURER MODEL PRESSURE RATING SPECIFICATIONS BV-1 BALANCE VALVE 3/4 INCH BELL & GOSSETT CB SERIES, CB 3/4 200 PSIG @ 250 DEGF 0.6 - 3.0 GPM RANGE, BRONZE, BALL OR PLUG TYPE BODY WITH CALIBRATED ORIFICE OR VENTURI; GLASS AND CARBON FILLED TFE OR EPDM SEAT RINGS, EPDM STEM O-RING, WITH INTEGRAL SEALS FOR PORTABLE DIFFERENTIAL PRESSURE METER, WITH LEVEL HANDLE AND MEMORY STOP TO RETAIN SET POSITION. V-1 SHUT-OFF BALL VALVE WATTS B6000-SS 300 PSIG WOG MSS SP-110, 2-PIECE, STANDARD PORT, BRONZE BODY, 316 SS BALL & STEM, PTFE OR TFE SEAT S-1 STRAINERS, WYE PATTERN WATTS SERIES 777 200 PSIG @ 210 ˚F WOG BRONZE BODY, #20 MESH 304 STAINLESS STEEL SCREEN, THREAD OR SWEAT CONNECTION. AV-1 AIR VENTS BELL & GOSSETT MODEL 87 150 PSIG BRASS BODY, NON-FERROUS INTERNALS 1 FOR VALVES INSTALLED IN INSULATED PIPING SYSTEMS, PROVIDE EXTENDED HANDLE 2 PROVIDE VALVES WITH UNIONS OR FLANGES AT EACH PIECE OF EQUIPMENT ARRANGED TO ALLOW SERVICE, MAINTENANCE AND EQUIPMENT REMOVAL WITHOUT SYSTEM SHUTDOWN 3 PROVIDE STRAINERS AT INLET OF CONTROL VALVES, STEAM TRAPS, AIR SEPARATORS, AND WHERE INDICATED. INSTALL NIPPLE AND BALL VALVE IN BLOWDOWN CONNECTION. 4 PROVIDE MANUAL AIR VENTS AT HIGH POINTS IN PIPING SYSTEM, HEAT TRANSFER COILS, AND ELSEWHERE AS REQUIRED FOR SYSTEM AIR VENTING. 5 PROVIDE DRAIN VALVES AT MAIN SHUT-OFF VALVES, LOW POINTS OF PIPING SYSTEM, AND ELSEWHERE AS REQUIRED FOR SYSTEM DRAINING. 6 PROVIDE TAGS FOR ALL NEW CONTROL AND SHUT-OFF VALVES. TAGS SHALL BE BRASS, 1-1/2-INCH ROUND, WITH STAMPED LETTERS AND NUMBERS. PROVIDE VALVE CHART. SCALE:1" = 1'-0"2 FAN COIL UNIT COIL PIPING DETAIL FAN COIL UNIT SCHEDULE TAG SERVES MAF BOD MODEL BOD CFM HEATING COIL ELECTRICAL CAPACITY (MBH) AIR SIDE WATER SIDE FLA V / PH / HZEAT DB (F) ESP (IN WG) EWT (F) LWT (F) GPM WPD (FT) TYPE FCU-G09 KITCHENETTE G09 TRANE FFJB0401B 400 27.12 70 NONE 140 110 1.81 4.61 3-ROW 3.10 115 / 1 / 60 1 RATINGS: ARI 440, ASHRAE 33, UL 1995 2 COIL: COPPER TUBE, ALUMINUM FINS, TESTED TO 200 PSIG, 220 DEGREE ENTERING WATER TEMPERATURE, WITH MANUAL AIR VENT AND DRAIN VALVE, LEFT HAND CONNECTIONS WITHOUT AUXILIARY DRAIN 3 FAN: DOUBLE WIDTH, DOUBLE INLET, FORWARD CURVED, CENTRIFUGAL 4 MOTOR: ECM 5 CABINET: VERTICAL SLOPE TOP, FRONT TOE SPACE INLET, TOP BAR GRILLE OUTLET, BAKED ENAMEL FINISH, COLOR SELECTED BY OWNER FROM STANDARD COLOR CHART , WITH 1/2-INCH COATED FIBERGLASS INSULATION, LEVELING FEET 6 FILTERS: MERV 8 7 OPTIONAL ACCESSORIES: UNIT MOUNTED ZONE SENSOR MODULE, FACTORY INSTALLED 8 INSTALL FAN COIL UNITS TO COMPLY WITH NFPA 90A. REF.REF. 1 SINK (D) 2 1 3 3 3 3 1" SP (E)1" SP (E)1" SP FLUSH VALVE (E) 1/2" SP (D) 1/2" SP (D) 2 CEILING EA GRILLE (D)2 6x6 EA (D) 12X6 EA (D) 1/2" DCW, 1/2" DHW RISERS (E)1/2" DCW (E)1/2" DHW (E)1-1/2" SAN (D) 4 1-1/2" SAN RISER (E) 4 2 3" SAN/VENT RISER (E) W.C.O. 1 2 1" SP (E) 2 3RANGE HOOD (N)1/2" DCW (E)1/2" DHW (E)4 1/2" DCW, 1/2" DHW RISERS WITHIN WALL (E) 5 3" SAN/VENT RISER (E) 0 1 2 4 SCALE: 1/2"=1'-0"CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.IPP.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER COMPLEX BAKER COMPLEX KITCHEN RENOVATIONS MP-101 11121224 BAKER TOWER PARTIAL FLOOR PLANS T. FISHER TRF 3004 December 17, 2018 MP-101 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING SINK AND ASSOCIATED FAUCET/DRAIN ASSEMBLY. REMOVE 1/2" DOMESTIC COLD WATER AND 1/2" DOMESTIC HOT WATER BRANCH LINES BACK TO RISER. EXISTING 1/2" RISERS TO REMAIN FOR RECONNECTION. PARTIALLY REMOVE 1-1/2" SANITARY DRAIN PIPING. 2 DISCONNECT AND REMOVE EXISTING EXHAUST FAN AND ASSOCIATED DUCTWORK, GRILLES, AND ACCESSORIES ABOVE CEILING. 3 DISCONNECT AND REMOVE EXISTING CONCEALED SPRINKLER HEAD AND ASSOCIATED 1/2" BRANCH PIPING BACK TO 1" MAIN. EXISTING 1" TEE TO REMAIN FOR RECONNECTION. 4 DISCONNECT AND REMOVE PORTION OF EXISTING 1-1/2" SANITARY DRAIN BACK TO DROP. EXISTING RISER FROM BELOW SLAB TO REMAIN FOR RECONNECTION. MP-101 KEYED CONSTRUCTION NOTES 1 PROVIDE SINK, FAUCET, 1/2" DOMESTIC COLD, 1/2" HOT WATER SUPPLY, 1-1/2" DRAIN, AND 1-1/4" VENT TO CABINET/COUNTER MOUNTED KITCHEN SINK. 2 PROVIDE UPRIGHT SPRINKLER HEAD. INSTALL/CONNECT TO EXISTING 1" SPRINKLER BRANCH PIPING TEE. 3 RECIRCULATING RANGE HOOD, REFER TO ARCHITECTURAL DRAWINGS. RANGE HOOD SHALL UTILIZE EXISTING ADJACENT NATURAL VENTILATION AS MAKE-UP AIR SOURCE. 4 PROVIDE 1/2" COLD AND 1/2" HOT DOMESTIC WATER SUPPLY TO SINK FAUCET WITH SUPPLY SHUTOFFS. CONNECT TO EXISTING 1/2" COLD AND 1/2" HOT DOMESTIC WATER SUPPLY RISERS. 5 PROVIDE 1-1/2" SANITARY DRAIN WITH TRAP TO SINK PF-1. CONNECT TO EXISTING 1-1/2" SANITARY DRAIN RISER. CONTRACTOR SHALL SCOPE EXISTING SANITARY LINE. # # MP-101 GENERAL PLUMBING NOTES 1.0 EXISTING DOCUMENTATION OF THE SANITARY AND VENT SYSTEM PIPING LAYOUT IS NOT AVAILABLE. CONTRACTOR SHALL SCOPE AND IDENTIFY EXISTING SANITARY AND VENT PIPING IN THE VACINITY OF THE SCOPE OF WORK. PROVIDE RESULTS TO FACILITIES ENGIEERING FOR REVIEW. SCALE:1/2" = 1'-0"1 BASEMENT MECHANICAL/PLUMBING DEMOLITION PLAN SCALE:1/2" = 1'-0"2 BASEMENT MECHANICAL/PLUMBING CONSTRUCTION PLAN 1 10/10/18 ISSUE FOR 50% DD REVIEW 2 11/12/18 ISSUE FOR 95% CD REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION REF.REF.REF.1 2" HHWR (E)2" HHWS (E)RADIATOR (D)1 (S) G10 (S) G09 (S) G08 1 MP-001 Sim 3 1 2 (S) G10 (S) G08 (S) G09 FCU-G09 3 1 MP-001 2 2" HHWR (E)2" HHWS (E)1FCU-G09 1 RADIATOR (D)2" HHWR (E)2" HHWS (E)1 CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.IPP.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER COMPLEX BAKER COMPLEX KITCHEN RENOVATIONS MP-102 11121224 BAKER NORTH AND SOUTH GROUND FLOOR PARTIAL HVAC FLOOR PLANS T. FISHER TRF 3004 December 17, 2018 SCALE:1/4" = 1'-0"1 SOUTH GROUND FLOOR PARTIAL HVAC DEMOLITION PLAN SCALE:1/4" = 1'-0"2 SOUTH GROUND FLOOR PARTIAL HVAC CONSTRUCTION PLAN SCALE:1/4" = 1'-0"4 NORTH GROUND FLOOR PARTIAL HVAC CONSTRUCTION PLAN SCALE:1/4" = 1'-0"3 NORTH GROUND FLOOR PARTIAL HVAC DEMOLITION PLAN MP-102 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING FIN TUBE RADIATION, COVER, CONTROL VALVE, AND THERMOSTAT. REMOVE PIPING BACK TO MAINS AND CAP. MP-102 KEYED CONSTRUCTION NOTES 1 VERTICAL SLOPE TOP FAN COIL UNIT. MOUNT FAN COIL UNIT AND ENCLOSURE TO STUD WALL WITH MANUFACTURERS PROVIDED BRACKETS. REFER TO SCHEDULE FOR SPECIFICATIONS AND ACCESSORIES. REFER TO 2/M-001 FOR PIPING DETAILS. 2 RECIRCULATING RANGE HOOD, REFER TO ARCHITECTURAL DRAWINGS. RANGE HOOD SHALL UTILIZE EXISTING ADJACENT NATURAL VENTILATION AS MAKE-UP AIR SOURCE. 3 CONNECT 3/4" HYDRONIC HEATING SUPPLY AND RETURN TO EXISTING 2" HYDRONIC SUPPLY AND RETURN PIPING WITH SHUTOFF VALVES. ROUTE 3/4" PIPING EXPOSED TO DROPS WITHIN STUD WALL TO FINTUBE RADIATION ENCLOSURE. 1 10/10/18 ISSUE FOR 50% DD REVIEW 2 11/12/18 ISSUE FOR 95% CD REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION # # 0 2 4 8 SCALE: 1/4"=1'-0" REF.REF.REF.REF.1 MP-001 PF-1 1 4" SP (E)2" DCW (E)2" DHW (E)1" DHWR (E)2 3 1/2" DCW DROP 1/2" DHW DROP 3 3 4 1 4" SP (E)2" DCW (E)1" DHWR (E)1/2" DCW, 1/2" DHW DROPS (D)2" DCW (E)1 1/2" DCW, 1/2" DHW DROPS (D)4" SP (E)2" DHW (E)2" DCW (E)1" DHWR (E)4" SP (E)2" DHW (E)2" DCW (E)1" DHWR (E)PF-1 1 4 1/2" DCW DROP 3 1/2" DHW DROP 3 CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.IPP.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 BAKER COMPLEX BAKER COMPLEX KITCHEN RENOVATIONS MP-103 11121224 BAKER NORTH AND SOUTH GROUND FLOOR PARTIAL PLUMBING FLOOR PLANS T. FISHER TRF 3004 December 17, 2018 SCALE:1/4" = 1'-0"4 NORTH GROUND FLOOR PARTIAL PLUMBING CONSTRUCTION PLAN SCALE:1/4" = 1'-0"3 NORTH GROUND FLOOR PARTIAL PLUMBING DEMOLITION PLAN MP-103 KEYED CONSTRUCTION NOTES 1 PROVIDE SINK, FAUCET, 1/2" DOMESTIC COLD, 1/2" HOT WATER SUPPLY, 1-1/2" DRAIN, AND 1-1/4" VENT TO CABINET/COUNTER MOUNTED KITCHEN SINK. 2 RECIRCULATING RANGE HOOD, REFER TO ARCHITECTURAL DRAWINGS. RANGE HOOD SHALL UTILIZE EXISTING ADJACENT NATURAL VENTILATION AS MAKE-UP AIR SOURCE. 3 PROVIDE 1/2" COLD AND 1/2" HOT DOMESTIC WATER SUPPLY TO SINK FAUCET WITH SUPPLY SHUTOFFS. CONNECT TO EXISTING 1/2" COLD AND 1/2" HOT DOMESTIC WATER SUPPLY TAPS ON EXISTING MAINS. ROUTE PIPING WITHIN STUD WALL DOWN TO WITHIN SINK BASE CABINET. 4 PROVIDE 1-1/2" SANITARY DRAIN WITH TRAP TO SINK PF-1. CONNECT TO EXISTING 2" SANITARY DRAIN RISER WITHIN WALL. MP-103 KEYED DEMOLITION NOTES 1 REMOVE 1/2" DOMESTIC COLD WATER AND 1/2" DOMESTIC HOT WATER BRANCH LINES BACK TO MAINS AND CAP. REMOVE 1-1/2" SANITARY DRAIN PIPING FROM SINK TO WITHIN WALL AND CAP. SCALE:1/4" = 1'-0"1 SOUTH GROUND FLOOR PARTIAL PLUMBING DEMOLITION PLAN SCALE:1/4" = 1'-0"2 SOUTH GROUND FLOOR PARTIAL PLUMBING CONSTRUCTION PLAN 1 10/10/18 ISSUE FOR 50% DD REVIEW 2 11/12/18 ISSUE FOR 95% CD REVIEW 3 11/20/18 ISSUE FOR COORDINATED REVIEW 4 12/17/18 ISSUE FOR CONSTRUCTION 0 2 4 8 SCALE: 1/4"=1'-0" # # CORNELLUNIVERS IT Y F O U NDED5681ADFACILITIESENGINEERINGARCHIVE BAR CODEITHACA, NEW YORKARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:DATE:FACILITY:DESIGN:DRAWN:WWW.FCS.CORNELL.EDUIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION.WARNINGREVISIONSARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING201 HUMPHREYS SERVICE BLDGITHACA, NEW YORK 14853-3701BAKER COMPLEXBAKER COMPLEXKITCHENRENOVATIONSE-001.GENERALNOTES ANDSYMBOLLEGENDSE.REICHARDETR3004DECEMBER 17, 2018ELECTRICAL SUBMITTAL SCHEDULEMATERIALSCHEDULE/SHOPDWGS.PRODUCTDATASAMPLESINSPECTIONS& TESTSO&M DATA WARRANTIESPANELBOARDS XLIGHT FIXTURES AND LIGHTING CONTROL XWIRING DEVICES XCONDUCTORS XRACEWAYSXFIRE ALARMXLUMINAIRE SCHEDULETYPE DESCRIPTION MOUNTING SIZE MANUFACTURER CATALOG NO. VOLTAGE LAMPS WATTAGE FINISHA2 LED UNDERCABINET FIXTURE SURFACE 12" ECOSENSE SCDM1235MULT 120-277VLED 4 WHITEA3 LED INDIIRECT FIXTURE PENDANT 1x8 FINELITE S12-LED-ID-WCB-8-2E-S-835-OPEN-120V-SC-FA-FE-C4-OBO120V LED 23 WHITEA3E LED INDIIRECT FIXTURE PENDANT 1x8 FINELITE S12-LED-ID-WCB-8-2E-S-835-OPEN-120V-SC-FA-FE-C4-OBO W/ EM DRIVER120V LED 23 WHITEA4 LED INDIIRECT FIXTURE PENDANT 1x4 FINELITE S12-LED-ID-WCB-4-3E-SS-835-OPEN-120V-SC-FA-FE-C4-OBO120V LED 23 WHITEA5 LED INDIIRECT FIXTURE PENDANT 1x4 FINELITE S12-LED-ID-WCB-4-3E-HH-8-35-OPEN-120V-SC-FA-FE-C4-OBO120V LED 44 WHITEA5E LED INDIIRECT FIXTURE PENDANT 1x8 FINELITE S12-LED-ID-WCB-8-3E-HH-8-35-OPEN-120V-SC-FA-FE-C4-OBO W/EM DRIVER120V LED 44 WHITEGENERAL ELECTRICAL NOTES1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS AREDIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENTROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANYCONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALLBE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORKPROCEEDS.2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREASFROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OFWASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROMTHE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN ANDOPERABLE.3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/ORFLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THEMATERIAL PENETRATED.4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACTDOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OFINSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVALPRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK.5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDEEQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ONCONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTEDWITH ASSOCIATED PHASE CONDUCTORS.6.0 PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD. LABELALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDEPERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE ANDINVENTORY NUMBERS. COORDINATE EQUIPMENT INVENTORY NUMBERS WITHCORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667.7.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRALCONDUCTORS.8.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WETAREAS.9.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BEELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTEDOTHERWISE.10.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVEPANELBOARD. SIZE AS INDICATED.11.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORTHANGERS FOR CONDUIT AS NEEDED.12.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT ANDDEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE ANDREPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MINDSHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIESARE CORRECTED.ELECTRICAL SCOPE OF WORK1.0 PROVIDE POWER AND LIGHTING UPGRADES FOR THE KITCHEN RENOVATIONS INNORTH BAKER, SOUTH BAKER AND BAKER TOWER.ELECTRICAL LEGENDLIGHTING LEGENDMOTOR1'x4' LUMINAIREHARDWIRED EQUIPMENT CONNECTIONP-1A12HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT.EMERGENCY POWER OFF (EPO)GROUND ROD ELECTRODEDUPLEX RECEPTACLE WITH GFCI PROTECTIONDUPLEX RECEPTACLE WITH AFCI PROTECTIONQUAD RECEPTACLELINETYPES LEGENDSPECIAL RECEPTACLE5-30RPANELBOARDJUNCTION BOXB = INSTALLED IN BASEBOARDTR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTTSR = SURFACE RACEWAYWP = WEATHERPROOFAC = AIR CONDITIONERXDUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLEMOTOR STARTERJ2'x4' LUMINAIRECEILING MOUNTED LUMINAIREEM LIGHTING BATTERY UNITCOMBO EXIT SIGN/EM LIGHTING BATTERY UNITSINGLE FACE, WALL MOUNT EXIT SIGNDOUBLE FACE, WALL MOUNT EXIT SIGNSINGLE FACE, CEILING MOUNT EXIT SIGNDOUBLE FACE, CEILING MOUNT EXIT SIGNLIGHT SWITCH:SAFETY SWITCH (NON-FUSED)SAFETY SWITCH (FUSED)X3 = 3-WAY SWITCH4 = 4-WAY SWITCHD = DIMMER SWITCHO = WALL SWITCH OCCUPANCY SENSORV = WALL SWITCH VACANCY SENSORW = WIRELESS SWITCHS = WIRELESS SCENE SWITCHWIRELESS OCCUPANCY SENSORWIRELESS DAYLIGHT SENSOROSWDS1'x2' LUMINAIREFIRE ALARM LEGENDFIRE ALARM CONTROL PANELBATTERY CABINETWATER FLOW SWITCHMUXPADREMOTE ANNUNCIATORD = DUCT SMOKE DETECTORR = RELAY BASEBR = BEAM RECEIVERBT = BEAM TRANSMITTERSB = SOUNDER BASESMOKE DETECTOR: TAMPER SWITCHAUDIBLE NOTIFICATION APPLIANCEFACPBATTMUXFAANAC PANELNACMANUAL PULL STATIONFSXF = FIXED TEMPERATURER = RATE OF RISER/F = COMBINATION RISE/FIXED TEMPERATUREHEAT DETECTOR: HXCARBON MONOXIDE DETECTORCOAMFXXcdCFSFSXXcdCTSADDRESSABLE MODULEXXcd = CANDELAC = CEILINGCOMBO A/V NOTIFICATION APPLIANCE: XXcd = CANDELAC = CEILINGVISUAL NOTIFICATION APPLIANCE:SUPPRESSION SYSTEMELECTRICAL ABBREVIATIONSAC AIR CONDITIONERAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFI ARC FAULT INTERRUPTERAMM ADDRESSABLE MONITOR MODULEAOM ADDRESSABLE OUTPUT MODULEARB AUXILIARY RELAY BOARDATS AUTOMATIC TRANSFER SWITCHB BASEBOARDBKR BREAKERC CONDUITCD CANDELACKT CIRCUITCR CONTROL RELAYEC ELECTRICAL CONTRACTOREMT ELECTRICAL METALLIC TUBINGEPO EMERGENCY POWER OFF STATIONFAA FIRE ALARM ANNUNCIATOR PANELFACP FIRE ALARM CONTROL PANELFSD FIRE SMOKE DAMPERGAA GENERATOR ALARM ANNUNCIATORGFI GROUND FAULT INTERRUPTERGND GROUNDHP HORSEPOWERKW KILOWATTLC LIGHTING CONTACTORLFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUITLTG LIGHTINGMCB MAIN CIRCUIT BREAKERMLO MAIN LUG ONLYMTS MANUAL TRANSFER SWITCHNAC NOTIFICATION APPLIANCE CIRCUITNIC NOT IN CONTRACTOE OVERHEAD ELECTRICPC PHOTOCELLPM PLUGMOLDPP POWER PANELPVC POLYVINYL CHLORIDE CONDUITRGS RIGID GALVANIZED STEEL CONDUITSR SURFACE RACEWAYST SHUNT TRIPTM THERMAL MAGNETICTR TRIM/CASEWORK/WAINSCOTTTSP TWISTED SHIELDED PAIRTYP TYPICALUE UNDERGROUND ELECTRICUON UNLESS OTHERWISE NOTEDUPS UNINTERRUPTIBLE POWER SUPPLYVVOLTSVA VOLT AMPSWP WATERPROOFUNDERGROUND ELECTRICUEUNDERGROUND LIGHTINGULOVERHEAD ELECTRICOETO BE PROVIDEDDEMOLITION / TO BE RELOCATEDEXISTING TO REMAINUNDERGROUND TELCOUCMOUNTING HEIGHTSCARD READER 48" TOP OF BOXLIGHT SWITCH 48" TOP OF BOXRECEPTACLE 18" TOP OF BOXDATA OUTLET 18" TOP OF BOXTV OUTLET 84" TOP OF BOXPHONE OUTLET 48" TOP OF BOXSAFETY SWITCH 60" CENTERLINE OF HANDLEMOTOR STARTER 60" CENTERLINE OF HANDLEPANELBOARD 72" TOP OF PANELBOARDMANUAL PULL STATION 48" OPERABLE HANDLENOTIFICATION APPLIANCE 80" BOTTOM OF LENSDOOR HOLD OPEN COORDINATE IN FIELDEM BATTERY UNIT 96" BOTTOM OF UNITEM REMOTE UNIT 102" BOTTOM OF UNITEXIT SIGN 96" BOTTOM OF UNITLIGHT POLE WITH LED LUMINAIRES, REFER TO PLANS FOR NUMBER AND CONFIGURATION OFHEADSGENERAL ELECTRICAL DEMOLITION NOTES1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDINGASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHERAPPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED.REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTEDOTHERWISE.2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEWWORK SHALL BE REUSED WHERE POSSIBLE.3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTINGSYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWNTO BE DEMOLISHED.4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITHTHE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRERATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCHSURROUNDING MATERIALS, FINISHES, AND COLORS.5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROMDEMOLITION NOT SPECIFIED TO BE INFILLED.6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURINGCONSTRUCTION.1 10/11/18 ISSUE FOR DD REVIEW2 11/12/18 ISSUE FOR 95% REVIEW3 11/20/18 ISSUE FOR COORDINATED REVIEW4 12/17/18 ISSUE FOR CONSTRUCTION 208V50AGFIHFGFIGFI33GFIDEF123945168677777SSSFPANEL A NORTHFSSSPANEL A SOUTHCORNELLUNIVERS IT Y F O U NDED5681ADFACILITIESENGINEERINGNARCHIVE BAR CODEITHACA, NEW YORKARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:DATE:FACILITY:DESIGN:DRAWN:WWW.FCS.CORNELL.EDUIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION.WARNINGREVISIONSARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING201 HUMPHREYS SERVICE BLDGITHACA, NEW YORK 14853-3701BAKER COMPLEXBAKER COMPLEXKITCHENRENOVATIONSE-101.ELECTRICALREMOVALPLANSE.REICHARDETR3004DECEMBER 17, 2018#E-101 KEYED DEMOLITION NOTES1 DISCONNECT AND REMOVE RECEPTACLES AT COUNTER TOP. REMOVE CONDUITAND CONDUCTORS BACK TO KITCHEN LOAD CENTER.2 DISCONNECT AND REMOVE RECEPTACLE UNDER SINK. REMOVE CONDUIT ANDCONDUCTORS BACK TO KITCHEN LOAD CENTER.3 DISCONNECT AND REMOVE RANGE RECEPTACLE. REMOVE CONDUIT ANDCONDUCTORS BACK TO KITCHEN LOAD CENTER.4 DISCONNECT AND REMOVE REFRIGERATOR RECEPTACLE. REMOVE CONDUIT ANDCONDUCTORS BACK TO KITCHEN LOAD CENTER.5 DISCONNECT AND REMOVE EXHAUST FAN POWER AND SWITCH. REMOVE CONDUITAND CONDUCTORS BACK TO KITCHEN LOAD CENTER.6 DISCONNECT AND REMOVE LIGHT FIXTURES AND SWITCH. REMOVE CONDUIT ANDCONDUCTORS BACK TO SOURCE.7 DISCONNECT AND REMOVE LIGHT FIXTURES AND SWITCHES. REMOVE CONDUITAND CONDUCTORS BACK TO EXISTING JUNCTION BOXES ON CEILING AND SAVEFOR REUSE.8 DISCONNECT AND REMOVE HEAT DETECTOR. SAVE CIRCUIT FOR REUSE.9 DISCONNECT AND REMOVE KITCHEN LOAD CENTER. REMOVE FEED BACK TOJUNCTION BOX SPLICE(FORMER MDP).10 DISCONNECT AND REMOVE RECEPTACLE AT FLOOR LEVEL. REMOVE CONDUIT ANDCONDUCTORS BACK TO KITCHEN LOAD CENTER.11 DISCONNECT AND REMOVE EXISTING DATA JACKS. PROVIDE 4”X4” COVER ONEXISTING DATA JUNCTION BOX AND SAVE EXISTING DATA WIRING FOR REUSE TOEXTEND TO NEW VENDING MACHINE LOCATION. COORIDATE WITH CIT.12 DISCONNECT AND REMOVE KITCHEN LOAD CENTER AND BACKBOX. REMOVEEXISTING CONDUCTORS BACK TO EXISTING SPLICE IN JUNCTION BOX INELECTRICAL ROOM. TAG AND SAVE FEEDER CONDUCTORS FROM MDP-1 FORREUSE TO FEED NEW PANEL.024 8SCALE: 1/4"=1'-0"SCALE:1/4" = 1'-0"1BAKER TOWER BASEMENT POWER REMOVAL PLANSCALE:1/4" = 1'-0"2BAKER TOWER BASEMENT LIGHTING AND FIRE ALARM REMOVAL PLANSCALE:1/4" = 1'-0"3NORTH BAKER BASEMENT REMOVAL PLANS777777777777721SCALE:1/4" = 1'-0"4SOUTH BAKER 1ST FLOOR REMOVAL PLANS717777777710111021112121 10/11/18 ISSUE FOR DD REVIEW2 11/12/18 ISSUE FOR 95% REVIEW3 11/20/18 ISSUE FOR COORDINATED REVIEW4 12/17/18 ISSUE FOR CONSTRUCTION F208V50ADOCDHS208V50A208V50ADDD33DD33DFDOCDDDHSKITCHEN PANEL LPP-G1JUNCTION BOX314522PANEL ANORTH225410143111213FCU-G0910141042253PANEL ASOUTH121113FCU-G091066677SSSFA3A3A5EA5A4A2A26677A3A3A5EA5A4A2A2FSSSA-5E96786A-3A-3A-3EA-3A-2A-2A-2666E-102 KEYED CONSTRUCTION NOTES1 PROVIDE 100 AMP, MLO PANEL IN LOCATION INDICATED. PROVIDE 3-#6 & 1-#6G IN 1'EMT FROM JUNCTION BOX SPLICE.2 PROVIDE NEMA 5-20R RECEPTACLE 6” ABOVE COUNTERTOP IN LOCATIONINDICATED.PROVIDE 2-#12 & 1-#12 GND (THHN) FROM 20A BREAKER IN PANEL TORECEPTACLES. PROVIDE SURFACE RACEWAY FROM PANEL TO THE NEW WALL.PROVIDE 3/4” EMT BEHIND WALL TO RECEPTACLES. REFER TO PANEL SCHEDULESFOR COUNTERTOP CIRCUITING.3 PROVIDE NEMA 5-20R RECEPTACLE INSIDE TOP CABINET FOR MICROWAVE POWER.PROVIDE 2-#12 & 1-#12 GND (THHN) FROM 20A BREAKER IN PANEL TO RECEPTACLE.PROVIDE SURFACE RACEWAY FROM PANEL TO THE NEW WALL. PROVIDE 3/4” EMTBEHIND WALL TO RECEPTACLE.REFER TO PANEL SCHEDULE FOR CIRCUITING.4 PROVIDE NEMA 14-50R RECEPTACLE FOR RANGE AT 18” AFF IN LOCATIONINDICATED. PROVIDE 3-#8 & 1-#10G IN ¾” EMT FROM PANEL TO RANGERECEPTACLE. REFER TO PANEL SCHEDULE FOR CIRCUITING.5 PROVIDE NEMA 5-20R RECEPTACLE AT 18” AFF IN LOCATION INDICATED FORREFIGERATOR.PROVIDE 2-#12 & 1-#12 GND (THHN) FROM 20A BREAKER IN PANEL TORECEPTACLE. PROVIDE SURFACE RACEWAY FROM PANEL TO THE NEW WALL.PROVIDE 3/4” EMT BEHIND WALL TO RECEPTACLE. REFER TO PANEL SCHEDULEFOR CIRCUITING.6 PROVIDE LIGHT FIXTURE IN LOCATION INDICATED. PENDANT MOUNT FIXTURE FROMCEILING AT 8' AFF. FOR 3-WAY CIRCUITS, PROVIDE LEVITON CAT NO. IP710LFZDIMMING SWITCH AT EXISTING SWITCH LOCATION AT ONE END AND LEVITON#5622-2W 3-WAY SWITCH AT THE OTHER. PROVIDE DIMMING SWITCH ONLY FOR THEBAKER TOWER LOUNGE AND LIGHTS IN FRONT OF VENDING MACHINES. PROVIDELOW VOLTAGE WIRING FOR DIMMING. CONNECT TO CIRCUITING SAVED FROMREMOVALS.7 PROVIDE UNDER CABINET FIXTURE IN LOCATION INDICATED. PROVIDE SENSORSWITCH CAT NO. SPODMRD DIMMER SWICH AT 6" ABOVE COUNTERTOPBACKSPLASH. CONNECT TO LIGHTING CIRCUIT SAVED FROM REMOVALS. PROVIDESURFACE RACEWAY FROM LIGHTING JUNCTION BOX ON CEILING TO WALL ANDPROVIDE 3/4" EMT BEHIND WALL.8 PROVIDE HEAT DETECTOR IN LOCATION INDICATED. RECONNECT TO EXISTINGCIRCUIT SAVED FROM REMOVALS.9 PROVIDE 75CD FIRE ALARM STROBE AT 84" IN LOCATION INDICATED. PROVIDE 2-#14IN 3/4" EMT FROM EXISTING FIRE ALARM STROBE CIRCUIT IN LOUNGE AND EXTENDNOTIFICATION CIRUIT FOR NEW DEVICE.10 PROVIDE NEMA 5-20R RECEPTACLE 6” ABOVE COUNTERTOP IN LOCATIONINDICATED.PROVIDE 2-#12 & 1-#12 GND (THHN) FROM 20A BREAKER IN PANEL TORECEPTACLES. PROVIDE SURFACE RACEWAY FROM PANEL TO THE NEW WALL.PROVIDE 3/4” EMT BEHIND WALL TO RECEPTACLE. REFER TO PANEL SCHEDULESFOR COUNTERTOP CIRCUITING.11 PROVIDE DATA JACKS IN NEW LOCATION FOR VENDING MACHINES. PROVIDE NEWCAT6 FROM WIRING SAVED FROM REMOVAL TO NEW LOCATION. COORDINATE ALLWORK WITH CIT.12 PROVIDE 100 AMP, SEMI-RECESSED MAIN BREAKER PANEL IN LOCATION INDICATED.CONNECT ALL BRANCH CIRCUITS AND FEEDER CABLES SAVED FROM REMOVALS.REFER TO PANEL SCHEDULE ON E-501 FOR ADDITIONAL INFORMATION.13 PROVIDE 2-#12 & 1-#12 GND (THHN) FROM 20A BREAKER IN PANEL TO THE CABINETHEATER. PROVIDE SURFACE RACEWAY FROM PANEL TO THE NEW WALL. PROVIDE3/4” EMT BEHIND WALL TO THE CABINET HEATER. REFER TO PANEL SCHEDULE FORCIRCUITING.14 PROVIDE DEDICATED NEMA 5-20R RECEPTACLE 18” ABOVE FLOOR FOR EACHVENDING MACHINE IN LOCATION INDICATED.PROVIDE 2-#12 & 1-#12 GND (THHN)FROM 20A BREAKER IN PANEL TO RECEPTACLE. PROVIDE SURFACE RACEWAYFROM PANEL TO RECEPTACLE.REFER TO PANEL SCHEDULE FOR CIRCUITING.#SCALE: 3/16"=1'-0"024612CORNELLUNIVERS IT Y F O U NDED5681ADFACILITIESENGINEERINGNARCHIVE BAR CODEITHACA, NEW YORKARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:DATE:FACILITY:DESIGN:DRAWN:WWW.FCS.CORNELL.EDUIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION.WARNINGREVISIONSARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING201 HUMPHREYS SERVICE BLDGITHACA, NEW YORK 14853-3701BAKER COMPLEXBAKER COMPLEXKITCHENRENOVATIONSE-102.ELECTRICALINSTALLATIONPLANSE.REICHARDETR3004DECEMBER 17, 2018SCALE:3/16" = 1'-0"1BAKER TOWER POWER INSTALLATIONSCALE:3/16" = 1'-0"2NORTH BAKER POWER PLANSCALE:3/16" = 1'-0"5SOUTH BAKER POWER PLANSCALE:3/16" = 1'-0"3NORTH BAKER LIGHTING PLANSCALE:3/16" = 1'-0"6SOUTH BAKER LIGHTING PLANSCALE:3/16" = 1'-0"4BAKER TOWER LIGHTING INSTALLATION1 10/11/18 ISSUE FOR DD REVIEW2 11/12/18 ISSUE FOR 95% REVIEW3 11/20/18 ISSUE FOR COORDINATED REVIEW4 12/17/18 ISSUE FOR CONSTRUCTION CORNELLUNIVERS IT Y F O U NDED5681ADFACILITIESENGINEERINGARCHIVE BAR CODEITHACA, NEW YORKARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:DATE:FACILITY:DESIGN:DRAWN:WWW.FCS.CORNELL.EDUIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION.WARNINGREVISIONSARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING201 HUMPHREYS SERVICE BLDGITHACA, NEW YORK 14853-3701BAKER COMPLEXBAKER COMPLEXKITCHENRENOVATIONSE-501.PANELSCHEDULESE.REICHARDETR3004DECEMBER 17, 2018TOTAL DEMAND AMPS:0 ATOTAL CONN AMPS:0 ATOTAL DEMAND:0 VATOTAL CONN LOAD:0 VALOAD CLASSIFICATION CONN LOAD DEMAND FACTOR EST DEMAND PANEL TOTALSTOTAL AMPS:0 A 0 ATOTAL LOAD:0 VA 0 VA2324212219201718151613 SPARE 20 1 0 0 1 20 SPARE 1411 SPARE 20 1 0 0 1 20 SPARE 129 SPARE 20 1 0 0 1 20 SPARE 107 SPARE 20 1 0 0 1 20 SPARE 85 COUNTERTOP RECEPTACLES 20 1 0 01 20 REFRIGERATOR RECEPTACLE 63 -- -- -- 0 0 1 20 MICROWAVE RECEPTACLE 41 RANGE 20 2 0 0 1 20 LIGHTING 2CKT DESCRIPTION TRIP POLES A B POLES TRIP DESCRIPTION CKTENCLOSURE:NEMA 1MOUNTING:SURFACEWIRES:3MAINS RATING:100 AFED FROM: PHASE:1MAINS TYPE:MLOLOCATION:Room B08VOLTS:120/240VAIC RATING:10,000 AMPSPANEL LPP-G1TOTAL DEMAND AMPS:0 ATOTAL CONN AMPS:0 ATOTAL DEMAND:0 VATOTAL CONN LOAD:0 VALOAD CLASSIFICATION CONN LOAD DEMAND FACTOR EST DEMAND PANEL TOTALSTOTAL AMPS:0 A 0 ATOTAL LOAD:0 VA 0 VA29 -- -- -- 0 0 -- -- -- 3027 -- -- -- 0 0 -- -- -- 2825 PANEL A-1 60 3 0 0 3 100 MAIN 2623 -- -- -- 0 0 -- -- -- 2421 -- -- -- 0 0 2 20 ATTIC EX FAN FOR BATHS 2219 3PH MOTORS MECH RM 40 3 0 0 1 20 SPARE 2017 SPARE 20 1 0 0 1 20 SPARE 1815 VENDING MACHINE 20 1 0 0 1 20 SPARE 1613 VENDING MACHINE 20 1 0 0 1 20 COUNTERTOP RECEPTACLES 1411 REC 20 1 0 0 1 20 REFRIGERATOR 129 AIR DRYER 20 1 0 0 1 20 HAND DRYER BATH 107 -- -- -- 0 0 1 20 COUNTERTOP RECEPTACLES 85 AIR COMPRESSOR 20 2 0 0 1 20 MICROWAVE 63 SPARE 20 1 0 0 -- -- -- 41 CABINET HEATER 20 1 0 0 2 50 RANGE 2CKT DESCRIPTION TRIP POLES A B POLES TRIP DESCRIPTION CKTENCLOSURE:NEMA 1MOUNTING:SURFACEWIRES:4MAINS RATING:100 AFED FROM: PHASE:3MAINS TYPE:MAIN BREAKERLOCATION:Room (N) G09VOLTS:208Y/120VAIC RATING:10,000 AMPSPANEL PANEL A NORTHTOTAL DEMAND AMPS:0 ATOTAL CONN AMPS:0 ATOTAL DEMAND:0 VATOTAL CONN LOAD:0 VALOAD CLASSIFICATION CONN LOAD DEMAND FACTOR EST DEMAND PANEL TOTALSTOTAL AMPS:0 A 0 A 0 ATOTAL LOAD:0 VA 0 VA 0 VA29 -- -- -- 0 0 -- -- -- 3027 -- -- -- 0 0 -- -- -- 2825 HEAT 40 3 0 0 3 100 MAIN 2623 -- -- -- 0 0 -- -- -- 2421 RANGE 50 2 0 0 2 20 AIR COMPRESSOR 2219 STAIRWAY HEATER EAST 20 1 0 0 -- -- -- 2017 MICROWAVE 20 1 0 0 2 30 DRYER BASEMENT 1815 KITCHEN DINING LIGHTS 20 1 0 0 1 20 HAND DRYER BATH 1613 EXISTING LOAD 20 1 0 0 1 20 STAIRWELL HEATERS WEST 1411 EXISTING LOAD 20 1 0 0 1 20 DSC 8500 UPS REC 129 COUNTERTOP RECEPTACLES 20 1 0 0 1 20 HW DISPENSER 107 COUNTERTOP RECEPTACLES 20 1 0 0 1 20 VENDING MACHINE 85 SPARE 20 1 0 0 1 20 VENDING MACHINE 63 REFRIGERATOR 20 1 0 0 1 20 SPARE 41 CABINET HEATER 20 1 0 0 1 20 SPARE 2CKT DESCRIPTION TRIP POLES A B C POLES TRIP DESCRIPTION CKTENCLOSURE:Type 1MOUNTING:SurfaceWIRES:4MAINS RATING:100 AFED FROM: PHASE:3MAINS TYPE:MAIN BREAKERLOCATION:Room (S) G09VOLTS:208Y/120VAIC RATING:10,000 AMPSPANEL PANEL A SOUTH1 10/11/18 ISSUE FOR DD REVIEW2 11/12/18 ISSUE FOR 95% REVIEW3 11/20/18 ISSUE FOR COORDINATED REVIEW4 12/17/18 ISSUE FOR CONSTRUCTION