HomeMy WebLinkAboutDeltaTauDeltaCodeRemediation 18029 stamped setGENERALG001 COVER SHEETARCHITECTURALA101 GROUND, FIRST & SECOND FLOOR PLANSA601 DOOR SCHEDULE AND DETAILSASBESTOS ABATEMENTAA-100 ASBESTOS ABATEMENT GROUND, FIRST &SECOND FLOOR PLANSPROJECT INFORMATIONDATE:JOB NUMBER:CONSTRUCTION CLASSIFICATION:SPRINKLER PROTECTION:BUILDING USE CLASSIFICATION:HOLT Architects, P.C.Architects, Planners, and Interior Designers619 W. State Street, Ithaca, New York 14850132 E. Jefferson Street, Syracuse, New York 13202Tel 607.273.7600 www.holt.comHOLTARCHITECTS104 Mary Ann Wood Drive,Ithaca, NYCornell University2/4/201918029TYPE 3NFPA 13 THROUGHOUTBCNYS: R2Cornell UniversityDelta Tau DeltaDelta Tau DeltaCode RemediationG001GENERAL NOTES1 DIMENSIONS NOTES "EQ" ARE EQUAL TO EACH OTHER ONLY IF THEY ARE ON THE SAME DIMENSION STRING AND IN THE SAME ROW.2 DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. REFER TO DRAWINGS FOR DIMENSIONS. REQUIRED CRITICAL DIMENSIONS NOT FOUND SHOULD BE FIELD VERIFIED OR OBTAINEDFROM ARCHITECT. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN FIELD (EXISTING AND PROPOSED CONSTRUCTION) AND BRING ANY DISCREPANCIES TO THEIMMEDIATE ATTENTION OF THE ARCHITECT3 ALL WOOD COMPONENTS, ROUGH AND FINISHED, IN CORRIDORS, FIRE STAIRS, AND LOBBIES SHALL RECEIVE FIRE RETARDING TREATMENT (FRT)4 ROOM NUMBERING IS FOR CONSTRUCTION PURPOSES ONLY. ACTUAL ROOM NUMBERING TO BE COORDINATED WITH OWNER PRIOR TO ANY SCHEDULING OR LABELING5 CONTRACTOR SHALL PROVIDE BLOCKING OR PROVISIONS FOR SOLID ANCHORAGE AT WALL AND CEILING MOUNTED EQUIPMENT AND ACCESSORIES PROVIDED UNDER THISCONTRACT AND EQUIPMENT TO BE PROVIDED BY THE OWNER6 MAINTAIN EXISTING FIRE PROOFING AND FIRE RATED CONSTRUCTION. PATCH AS NEEDED TO MEET REQUIREMENTS.7 PATCH TO MATCH ALL FLOOR, BASE, WALL, AND CEILING FINISHES AFFECTED BY NEW WORK.8 ALL DIMENSIONS ARE TO FACE OF FRAMING, FACE OF MASONRY UNIT, OR FINISHED FACE OF EXISTING CONSTRUCTION.9 VERIFY ALL DIMENSIONS IN THE FIELD. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND FIELD CONDITIONS.10 ALL MASONRY DIMENSIONS ARE NOMINAL.11 PROPERTY LINE IS CONTRACT LIMIT LINE UNLESS OTHERWISE SHOWN.12 DOCUMENTS ARE BASED UPON ORIGINAL CONSTRUCTION DRAWINGS, EXISTING CONDITIONS MAY VARY. CONTACT ARCHITECT IF DISCREPANCIES ARISE.13 PROTECT ALL EXISTING FINISH SURFACES TO REMAIN. PATCH EXISTING CONSTRUCTION TO MATCH ADJACENT FINISHES TO REMAIN AT ALL REMOVALS AND AS REQUIRED BY NEWWORK (IE: PIPE PENETRATIONS, ETC). CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE RESULTING FROM HIS WORK, WHETHER INSIDE OR OUTSIDE CONTRACT LIMIT LINE.14 PROVIDE ACCESS PANELS AS REQUIRED AT ALL WALLS AND CEILINGS AT ALL VALVES, DAMPERS, CONCEALED JUNCTION BOXES, AND OTHER EQUIPMENT REQUIRING MAINTENANCE,ADJUSTMENTS OR SERVICING.15 NOTES ON ONE DETAIL OR DRAWING APPLY TO ALL SIMILAR DETAILS OR DRAWINGS.16 EXTEND ALL PARTITIONS FROM FLOOR TO UNDERSIDE OF DECK ABOVE UNLESS OTHERWISE INDICATED. MAKE THIS JOINT SMOKE TIGHT AND FIRESTOP AT RATED PARTITIONS.17 MISCELLANEOUS ELECTRICAL PANEL COVERS, GRILLES, ETC. TO BE PAINTED TO MATCH ADJACENT WALL SURFACES.18 MAINTAIN MEANS OF EGRESS, KEEPING IT FULLY SEPARATED FROM CONSTRUCTION AREA AT ALL TIMES WITH A 1-HOUR FIRE RESISTANT RATED BARRIER (U.L. DESIGN 309)19 PROVIDE A FRAMED, DUST PROOF BARRIER TO SEPARATE CONSTRUCTION AREA FROM THE REST OF THE FACILITY AT ALL TIMES. PROVIDE TEMPORARY FILTERS, AND/OR NEGATIVEAIR, AS REQUIRED TO PREVENT THE SPREAD OF DUST, FUMES, AND ODORS THROUGHOUT THE BUILDING. UPON COMPLETION OF THE WORK, REMOVE AND REPAIR ANY DAMAGECAUSED BY THE UNSTALLATION/PRESENCE OF THE TEMPORARY BARRIER TO A NEW-LIKE CONDITION.20 CONTRACTOR TO ARRANGE FOR SMOKE DETECTOR SHUTDOWNS TO PREVENT NUISANCE ALARMS CAUSED BY CONSTRUCTION ACTIVITIES OR CHANGE EXISTING SMOKE DETECTORSTO HEAT DETECTORS.PROJECT LOCATIONGENERAL NOTESSHEET LIST
11211111010910810710610510410310210110042113INFILL EXISTING OPENINGINCLUDING FLAT ARCHABOVE NEW DOOR; MATCHADJACENT WALLTHICKNESS AND FINISHES1114C1A601111111111120A208 209210211212213214200201202203204205206207KEYED NOTESREMOVE SECTION OF PARTITION TO ENLARGE DOOR OPENING WIDTHAPPROXIMATELY 4". REPAIR WALL TO MATCH EXISTING. REPAIR FLOOR WHEREVAT IS REMOVED AT EACH SIDE OF FRAME AS REQUIRED FOR REMOVAL OFEXISTING AND INSTALLATION OF NEW FRAMES. COLOR TO BE SELECTED BYARCHITECT TO MATCH EXISTING FLOORING AS CLOSELY AS POSSIBLE. TOUCHUP WALL PAINT AT FRAMES TO MATCH EXISTING.111111111111G0044G0002G06G072REMOVE EXISTING DOOR ANDINFILL WITH CONSTRUCTION TOMATCH ADJACENT WALLS ANDFINISHESPROVIDE OPENING FOR NEWDOOR: SAWCUT ANDREMOVE CMU, PROVIDE 1/2"X WIDTH OF WALL STEELPLATE LINTEL WITH 4"BEARING EACH END. SHORECMU ABOVE DURINGREMOVAL AND INSTALLATION.SHORTEN AND CAP EXISTINGELECTRICAL RACEWAY TOACCOMMODATE NEW DOOROPENINGPROVIDE 20A GFI OUTLET PER NEC2014 210.8(B) FOR RELOCATEDREFRIGERATOR ON WEST WALL.CONFIRM LOCATION WITH OWNERRELOCATE EXISTING LIGHTFIXTURE AND (2) 2 1/2" EMPTYTEL/DATA CONDUITS TO HIGHERON WALL OR CEILING TOACCOMMODATE NEW DOOROPENINGPROVIDE WOOD TRIM TO FINISHEXISTING WOOD PANELING TONEW DOOR FRAME. ALL SIDES.4' - 0" +/-ALIGN WITH CMU COURSINGRELOCATE EXISTING LIGHTSWITCH. PROVIDE COVERPLATEAT JUNCTION BOX ANDSURFACE RACEWAY.REMOVE AND REINSTALL DRYWALL SOFFIT AT CEILINGOVER DOOR G06 TO FACILITATE DUCT DISCONNECTIONAND RECONNECTION FOR NEW DOOR FRAMEINSTALLATION. RECONNECT DUCT DAMPER ANDCONNECTION TO LOCAL SMOKE DETECTOR.REMOVE SECTION OF FIN COVERFROM WALL TO WINDOW JAMB TOFIT RELOCATED REFRIGERATOR.CAP END.REL.REF.WALL TYPE: SEE A601X 1/8" = 1'-0"A4FIRST FLOOR KEY PLANABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design619 W. State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.comWARNING: It is a violation of NewYork State Law for any person,unless acting under the direction ofa licensed Architect, to alter thisdocument in any way. If a documentbearing the seal of an Architect isaltered, the altering Architect shallaffix to such document his seal andthe notation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.DATE:PROJECT:OTHER:DRAWN BY:2/4/2019 4:27:57 PM104 Mary Ann Wood Drive, Ithaca, NYA101GROUND,FIRST &SECONDFLOOR PLANS2/4/2019Cornell UniversityDelta Tau Delta18029HSCode Remediation 1/8" = 1'-0"C8SECOND FLOOR KEY PLAN 1/8" = 1'-0"A1GROUND FLOOR KEY PLANALIGN WITH DOOR JAMBNEW STAIRRAILSGENERAL FLOOR PLAN NOTES1 REFER TO ASBESTOS DRAWING AA-100 AND SPECIFICATION SECTION 02 82 00FOR FLOORING ABATEMENT SCOPE.2 PATCH FLOOR WHERE ASBESTOS FLOOR TILE IS REMOVED WITH NEW VCT.2 PROVIDE FLOOR TRANSITION STRIP BETWEEN NEW VCT FLOORIING ANDEXISTING CARPET.REVISION SCHEDULENAME DATE