CONCRETE UNIT MASONRY 042200 - 1
SECTION 042200 - CONCRETE UNIT MASONRY
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Concrete masonry units.
2. Mortar and grout.
3. Steel reinforcing bars.
4. Masonry-joint reinforcement.
5. Miscellaneous masonry accessories.
6. Masonry-cell fill.
1.3 DEFINITIONS
A. CMU(s): Concrete masonry unit(s).
B. Reinforced Masonry: Masonry containing reinforcing steel in grouted cells.
1.4 PREINSTALLATION MEETINGS
A. Preinstallation Conference: Conduct conference at Project site.
1.5 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: For the following:
1. Masonry Units: Show sizes, profiles, coursing, and locations of special shapes.
2. Reinforcing Steel: Detail bending, lap lengths, and placement of unit masonry reinforcing
bars. Comply with ACI 315. Show elevations of reinforced walls.
3. Fabricated Flashing: Detail corner units, end-dam units, and other special applications.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 2
1.6 DELIVERY, STORAGE, AND HANDLING
A. Store masonry units on elevated platforms in a dry location. If units are not stored in an
enclosed location, cover tops and sides of stacks with waterproof sheeting, securely tied. If
units become wet, do not install until they are dry.
B. Store cementitious materials on elevated platforms, under cover, and in a dry location. Do not
use cementitious materials that have become damp.
C. Store aggregates where grading and other required characteristics can be maintained and
contamination avoided.
D. Deliver preblended, dry mortar mix in moisture-resistant containers. Store preblended, dry
mortar mix in delivery containers on elevated platforms in a dry location or in covered
weatherproof dispensing silos.
E. Store masonry accessories, including metal items, to prevent corrosion and accumulation of dirt
and oil.
1.7 FIELD CONDITIONS
A. Protection of Masonry: During construction, cover tops of walls, projections, and sills with
waterproof sheeting at end of each day's work. Cover partially completed masonry when
construction is not in progress.
1. Extend cover a minimum of 24 inches down both sides of walls, and hold cover securely
in place.
B. Do not apply uniform floor or roof loads for at least 12 hours and concentrated loads for at least
three days after building masonry walls or columns.
C. Stain Prevention: Prevent grout, mortar, and soil from staining the face of masonry to be left
exposed or painted. Immediately remove grout, mortar, and soil that come in contact with such
masonry.
1. Protect base of walls from rain-splashed mud and from mortar splatter by spreading
coverings on ground and over wall surface.
2. Protect sills, ledges, and projections from mortar droppings.
3. Protect surfaces of window and door frames, as well as similar products with painted and
integral finishes, from mortar droppings.
4. Turn scaffold boards near the wall on edge at the end of each day to prevent rain from
splashing mortar and dirt onto completed masonry.
D. Cold-Weather Requirements: Do not use frozen materials or materials mixed or coated with ice
or frost. Do not build on frozen substrates. Remove and replace unit masonry damaged by frost
or by freezing conditions. Comply with cold-weather construction requirements contained in
TMS 602/ACI 530.1/ASCE 6.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 3
1. Cold-Weather Cleaning: Use liquid cleaning methods only when air temperature is 40
deg F and higher and will remain so until masonry has dried, but not less than seven days
after completing cleaning.
E. Hot-Weather Requirements: Comply with hot-weather construction requirements contained in
TMS 602/ACI 530.1/ASCE 6.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations for Masonry Units: Obtain exposed masonry units of a uniform texture and
color, or a uniform blend within the ranges accepted for these characteristics, from single
source from single manufacturer for each product required.
B. Source Limitations for Mortar Materials: Obtain mortar ingredients of a uniform quality,
including color for exposed masonry, from single manufacturer for each cementitious
component and from single source or producer for each aggregate.
2.2 PERFORMANCE REQUIREMENTS
A. Provide unit masonry that develops net-area compressive strengths of 1,900 psi at 28 days and a
unit prism sterngth (f'M) of 1,500 psi.
1. Determine net-area compressive strength of masonry from average net-area compressive
strengths of masonry units and mortar types (unit-strength method) according to TMS
602/ACI 530.1/ASCE 6.
B. Determine net-area compressive strength of masonry by testing masonry prisms according to
ASTM C 1314.
2.3 UNIT MASONRY, GENERAL
A. Masonry Standard: Comply with TMS 602/ACI 530.1/ASCE 6 except as modified by
requirements in the Contract Documents.
B. Defective Units: Referenced masonry unit standards may allow a certain percentage of units to
contain chips, cracks, or other defects exceeding limits stated. Do not use units where such
defects are exposed in the completed Work and will be within 20 feet vertically and
horizontally of a walking surface.
C. Fire-Resistance Ratings: Comply with requirements for fire-resistance-rated assembly designs
indicated.
1. Where fire-resistance-rated construction is indicated, units shall be listed and labeled by a
qualified testing agency acceptable to authorities having jurisdiction.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 4
2.4 CONCRETE MASONRY UNITS
A. Shapes: Provide shapes indicated and as follows, with exposed surfaces matching exposed
faces of adjacent units unless otherwise indicated.
1. Provide special shapes for lintels, corners, jambs, sashes, movement joints, headers,
bonding, and other special conditions.
2. Provide square-edged units for outside corners unless otherwise indicated.
B. CMUs: ASTM C 90.
1. Density Classification: Lightweight unless otherwise indicated.
2. Size (Width): Manufactured to dimensions 3/8 inch less-than-nominal dimensions.
3. Exposed Faces: Provide color and texture matching the range represented by Architect's
sample.
2.5 MASONRY LINTELS
A. Concrete Lintels: ASTM C 1623, matching CMUs in color, texture, and density classification;
and with reinforcing bars indicated. Provide lintels with net-area compressive strength not less
than that of CMUs.
B. Masonry Lintels: Prefabricated or built-in-place masonry lintels made from bond beam CMUs
matching adjacent CMUs in color, texture, and density classification, with reinforcing bars
placed as indicated and filled with coarse grout. Cure precast lintels before handling and
installing. Temporarily support built-in-place lintels until cured.
2.6 MORTAR AND GROUT MATERIALS
A. Portland Cement: ASTM C 150/C 150M, Type I or II, except Type III may be used for
cold-weather construction. Provide natural color or white cement as required to produce mortar
color indicated.
1. Alkali content shall not be more than 0.1 percent when tested according to ASTM C 114.
B. Hydrated Lime: ASTM C 207, Type S.
C. Portland Cement-Lime Mix: Packaged blend of portland cement and hydrated lime containing
no other ingredients.
D. Mortar Cement: ASTM C 1329/C 1329M.
1.Products: Subject to compliance with requirements, available products that may be
incorporated into the Work include, but are not limited to, the following:
a.Lafarge North America Inc.; Lafarge Mortar Cement or Magnolia Superbond
Mortar Cement.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 5
E. Mortar Pigments: Natural and synthetic iron oxides and chromium oxides, compounded for use
in mortar mixes and complying with ASTM C 979/C 979M. Use only pigments with a record
of satisfactory performance in masonry mortar.
1. Pigments shall not exceed 10 percent of portland cement by weight.
F. Aggregate for Mortar: ASTM C 144.
1. For mortar that is exposed to view, use washed aggregate consisting of natural sand or
crushed stone.
2. For joints less than 1/4 inch thick, use aggregate graded with 100 percent passing the No.
16 sieve.
3. White-Mortar Aggregates: Natural white sand or crushed white stone.
4. Colored-Mortar Aggregates: Natural sand or crushed stone of color necessary to produce
required mortar color.
G. Aggregate for Grout: ASTM C 404.
H. Cold-Weather Admixture: Nonchloride, noncorrosive, accelerating admixture complying with
ASTM C 494/C 494M, Type C, and recommended by manufacturer for use in masonry mortar
of composition indicated.
1.Products: Subject to compliance with requirements, available products that may be
incorporated into the Work include, but are not limited to, the following:
a.BASF Corporation Chemicals - Building Systems; Trimix-NCA.
b.Euclid Chemical Company (The); an RPM company; Accelguard 80.
c.Grace Construction Products, W. R. Grace & Co. - Conn.; Morset.
I. Water: Potable.
2.7 REINFORCEMENT
A. Uncoated Steel Reinforcing Bars: ASTM A 615/A 615M or ASTM A 996/A 996M, Grade 60.
B. Reinforcing Bar Positioners: Wire units designed to fit into mortar bed joints spanning masonry
unit cells and to hold reinforcing bars in center of cells. Units are formed from 0.148-inch steel
wire, hot-dip galvanized after fabrication. Provide units designed for number of bars indicated.
C. Masonry-Joint Reinforcement, General: Ladder type complying with ASTM A 951/A 951M.
1. Interior Walls: Mill-galvanized carbon steel.
2. Wire Size for Side Rods: 0.187-inch diameter.
3. Wire Size for Cross Rods: 0.187-inch diameter.
4. Spacing of Cross Rods: Not more than 16 inches o.c.
5. Provide in lengths of not less than 10 feet, with prefabricated corner and tee units.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 6
2.8 MISCELLANEOUS MASONRY ACCESSORIES
A. Compressible Filler: Premolded filler strips complying with ASTM D 1056, Grade 2A1;
compressible up to 35 percent; of width and thickness indicated; formulated from neoprene,
urethane, or PVC.
B. Preformed Control-Joint Gaskets: Made from styrene-butadiene-rubber compound, complying
with ASTM D 2000, Designation M2AA-805 or PVC, complying with ASTM D 2287, Type
PVC-65406 and designed to fit standard sash block and to maintain lateral stability in masonry
wall; size and configuration as indicated.
C. Bond-Breaker Strips: Asphalt-saturated felt complying with ASTM D 226/D 226M, Type I
(No. 15 asphalt felt).
2.9 MASONRY-CELL FILL
A. Lightweight-Aggregate Fill: ASTM C 331/C 331M.
2.10 MORTAR AND GROUT MIXES
A. General: Do not use admixtures, including pigments, air-entraining agents, accelerators,
retarders, water-repellent agents, antifreeze compounds, or other admixtures unless otherwise
indicated.
1. Do not use calcium chloride in mortar or grout.
2. Use portland cement-lime or mortar cement mortar unless otherwise indicated.
3. Add cold-weather admixture (if used) at same rate for all mortar that will be exposed to
view, regardless of weather conditions, to ensure that mortar color is consistent.
B. Preblended, Dry Mortar Mix: Furnish dry mortar ingredients in form of a preblended mix.
Measure quantities by weight to ensure accurate proportions, and thoroughly blend ingredients
before delivering to Project site.
C. Mortar for Unit Masonry: Comply with ASTM C 270, Proportion Specification. Provide the
following types of mortar for applications stated unless another type is indicated or needed to
provide required compressive strength of masonry.
1. For masonry below grade or in contact with earth, use Type M.
2. For reinforced masonry, use Type N.
3. For interior nonload-bearing partitions, Type O may be used instead of Type N.
D. Grout for Unit Masonry: Comply with ASTM C 476.
1. Use grout of type indicated or, if not otherwise indicated, of type (fine or coarse) that will
comply with TMS 602/ACI 530.1/ASCE 6 for dimensions of grout spaces and pour
height.
2. Proportion grout in accordance with ASTM C 476, Table 1 or paragraph 4.2.2 for
specified 28-day compressive strength indicated, but not less than 2000 psi.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 7
3. Provide grout with a slump of 8 to 11 inches as measured according to ASTM C 143/C
143M.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine conditions, with Installer present, for compliance with requirements for installation
tolerances and other conditions affecting performance of the Work.
1. For the record, prepare written report, endorsed by Installer, listing conditions detrimental
to performance of the Work.
2. Verify that foundations are within tolerances specified.
3. Verify that reinforcing dowels are properly placed.
4. Verify that substrates are free of substances that would impair mortar bond.
B. Before installation, examine rough-in and built-in construction for piping systems to verify
actual locations of piping.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION, GENERAL
A. Use full-size units without cutting if possible. If cutting is required to provide a continuous
pattern or to fit adjoining construction, cut units with motor-driven saws; provide clean, sharp,
unchipped edges. Allow units to dry before laying unless wetting of units is specified. Install
cut units with cut surfaces and, where possible, cut edges concealed.
3.3 TOLERANCES
A. Dimensions and Locations of Elements:
1. For dimensions in cross section or elevation, do not vary by more than plus 1/2 inch or
minus 1/4 inch.
2. For location of elements in plan, do not vary from that indicated by more than plus or
minus 1/2 inch.
3. For location of elements in elevation, do not vary from that indicated by more than plus
or minus 1/4 inch in a story height or 1/2 inch total.
B. Lines and Levels:
1. For bed joints and top surfaces of bearing walls, do not vary from level by more than 1/4
inch in 10 feet, or 1/2-inch maximum.
2. For conspicuous horizontal lines, such as lintels, sills, parapets, and reveals, do not vary
from level by more than 1/8 inch in 10 feet, 1/4 inch in 20 feet, or 1/2-inch maximum.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 8
3. For vertical lines and surfaces do not vary from plumb by more than 1/4 inch in 10 feet,
3/8 inch in 20 feet, or 1/2-inch maximum.
4. For conspicuous vertical lines, such as external corners, door jambs, reveals, and
expansion and control joints, do not vary from plumb by more than 1/8 inch in 10 feet,
1/4 inch in 20 feet, or 1/2-inch maximum.
5. For lines and surfaces, do not vary from straight by more than 1/4 inch in 10 feet, 3/8
inch in 20 feet, or 1/2-inch maximum.
6. For vertical alignment of exposed head joints, do not vary from plumb by more than 1/4
inch in 10 feet, or 1/2-inch maximum.
7. For faces of adjacent exposed masonry units, do not vary from flush alignment by more
than 1/16 inch.
C. Joints:
1. For bed joints, do not vary from thickness indicated by more than plus or minus 1/8 inch,
with a maximum thickness limited to 1/2 inch.
2. For exposed bed joints, do not vary from bed-joint thickness of adjacent courses by more
than 1/8 inch.
3. For head and collar joints, do not vary from thickness indicated by more than plus 3/8
inch or minus 1/4 inch.
4. For exposed head joints, do not vary from thickness indicated by more than plus or minus
1/8 inch.
3.4 LAYING MASONRY WALLS
A. Lay out walls in advance for accurate spacing of surface bond patterns with uniform joint
thicknesses and for accurate location of openings, movement-type joints, returns, and offsets.
Avoid using less-than-half-size units, particularly at corners, jambs, and, where possible, at
other locations.
B. Bond Pattern for Exposed Masonry: Unless otherwise indicated, lay exposed masonry in
running bond; do not use units with less-than-nominal 4-inch horizontal face dimensions at
corners or jambs.
C. Lay concealed masonry with all units in a wythe in running bond or bonded by lapping not less
than 4 inches. Bond and interlock each course of each wythe at corners. Do not use units with
less-than-nominal 4-inch horizontal face dimensions at corners or jambs.
D. Stopping and Resuming Work: Stop work by stepping back units in each course from those in
course below; do not tooth. When resuming work, clean masonry surfaces that are to receive
mortar, remove loose masonry units and mortar, and wet brick if required before laying fresh
masonry.
E. Fill cores in hollow CMUs with grout 24 inches under bearing plates, beams, lintels, posts, and
similar items unless otherwise indicated.
F. Build nonload-bearing interior partitions full height of story to underside of solid floor or roof
structure above unless otherwise indicated.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 9
1. Install compressible filler in joint between top of partition and underside of structure
above.
2. Fasten partition top anchors to structure above and build into top of partition. Grout cells
of CMUs solidly around plastic tubes of anchors and push tubes down into grout to
provide 1/2-inch clearance between end of anchor rod and end of tube. Space anchors 48
inches o.c. unless otherwise indicated.
3. Wedge nonload-bearing partitions against structure above with small pieces of tile, slate,
or metal. Fill joint with mortar after dead-load deflection of structure above approaches
final position.
4. At fire-rated partitions, treat joint between top of partition and underside of structure
above to comply with Section 078443 "Joint Firestopping."
3.5 MORTAR BEDDING AND JOINTING
A. Lay hollow CMUs as follows:
1. Bed face shells in mortar and make head joints of depth equal to bed joints.
2. Bed webs in mortar in all courses of piers, columns, and pilasters.
3. Bed webs in mortar in grouted masonry, including starting course on footings.
4. Fully bed entire units, including areas under cells, at starting course on footings where
cells are not grouted.
B. Lay solid CMUs with completely filled bed and head joints; butter ends with sufficient mortar
to fill head joints and shove into place. Do not deeply furrow bed joints or slush head joints.
C. Tool exposed joints slightly concave when thumbprint hard, using a jointer larger than joint
thickness unless otherwise indicated.
3.6 MASONRY-CELL FILL
A. Pour lightweight-aggregate fill into cavities to fill void spaces. Maintain inspection ports to
show presence of fill at extremities of each pour area. Close the ports after filling has been
confirmed. Limit the fall of fill to one story high, but not more than 20 feet.
3.7 MASONRY-JOINT REINFORCEMENT
A. General: Install entire length of longitudinal side rods in mortar with a minimum cover of 5/8
inch on exterior side of walls, 1/2 inch elsewhere. Lap reinforcement a minimum of 6 inches.
1. Space reinforcement not more than 16 inches o.c.
2. Provide reinforcement not more than 8 inches above and below wall openings and
extending 12 inches beyond openings in addition to continuous reinforcement.
B. Interrupt joint reinforcement at control and expansion joints unless otherwise indicated.
C. Provide continuity at wall intersections by using prefabricated T-shaped units.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 10
D. Provide continuity at corners by using prefabricated L-shaped units.
E. Cut and bend reinforcing units as directed by manufacturer for continuity at returns, offsets,
column fireproofing, pipe enclosures, and other special conditions.
3.8 LINTELS
A. Provide masonry lintels where shown and where openings of more than 12 inches for brick-size
units and 24 inches for block-size units are shown without structural steel or other supporting
lintels.
B. Provide minimum bearing of 8 inches at each jamb unless otherwise indicated.
3.9 REINFORCED UNIT MASONRY INSTALLATION
A. Temporary Formwork and Shores: Construct formwork and shores as needed to support
reinforced masonry elements during construction.
1. Construct formwork to provide shape, line, and dimensions of completed masonry as
indicated. Make forms sufficiently tight to prevent leakage of mortar and grout. Brace,
tie, and support forms to maintain position and shape during construction and curing of
reinforced masonry.
2. Do not remove forms and shores until reinforced masonry members have hardened
sufficiently to carry their own weight and other loads that may be placed on them during
construction.
B. Placing Reinforcement: Comply with requirements in TMS 602/ACI 530.1/ASCE 6.
C. Grouting: Do not place grout until entire height of masonry to be grouted has attained enough
strength to resist grout pressure.
1. Comply with requirements in TMS 602/ACI 530.1/ASCE 6 for cleanouts and for grout
placement, including minimum grout space and maximum pour height.
2. Limit height of vertical grout pours to not more than 60 inches.
3.10 FIELD QUALITY CONTROL
A. Testing and Inspecting: Owner will engage special inspectors to perform tests and inspections
and prepare reports. Allow inspectors access to scaffolding and work areas as needed to
perform tests and inspections. Retesting of materials that fail to comply with specified
requirements shall be done at Contractor's expense.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
CONCRETE UNIT MASONRY 042200 - 11
3.11 REPAIRING, POINTING, AND CLEANING
A. Remove and replace masonry units that are loose, chipped, broken, stained, or otherwise
damaged or that do not match adjoining units. Install new units to match adjoining units; install
in fresh mortar, pointed to eliminate evidence of replacement.
B. Pointing: During the tooling of joints, enlarge voids and holes, except weep holes, and
completely fill with mortar. Point up joints, including corners, openings, and adjacent
construction, to provide a neat, uniform appearance. Prepare joints for sealant application,
where indicated.
C. In-Progress Cleaning: Clean unit masonry as work progresses by dry brushing to remove
mortar fins and smears before tooling joints.
D. Final Cleaning: After mortar is thoroughly set and cured, clean exposed masonry as follows:
1. Remove large mortar particles by hand with wooden paddles and nonmetallic scrape hoes
or chisels.
2. Test cleaning methods on sample wall panel; leave one-half of panel uncleaned for
comparison purposes. Obtain Architect's approval of sample cleaning before proceeding
with cleaning of masonry.
3. Protect adjacent stone and nonmasonry surfaces from contact with cleaner by covering
them with liquid strippable masking agent or polyethylene film and waterproof masking
tape.
4. Wet wall surfaces with water before applying cleaners; remove cleaners promptly by
rinsing surfaces thoroughly with clear water.
5. Clean concrete masonry by applicable cleaning methods indicated in NCMA TEK 8-4A.
3.12 MASONRY WASTE DISPOSAL
A. Salvageable Materials: Unless otherwise indicated, excess masonry materials are Contractor's
property. At completion of unit masonry work, remove from Project site.
B. Masonry Waste Recycling: Return broken CMUs not used as fill to manufacturer for recycling.
C. Excess Masonry Waste: Remove excess clean masonry waste that cannot be used as fill, as
described above or recycled, and other masonry waste, and legally dispose of off Owner's
property.
END OF SECTION 042200
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
PIPE AND TUBE RAILINGS 055213 - 1
SECTION 055213 - PIPE AND TUBE RAILINGS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Aluminum pipe and tube railings.
1.3 COORDINATION
A. Coordinate selection of shop primers with topcoats to be applied over them. Comply with
paint and coating manufacturers' written recommendations to ensure that shop primers and
topcoats are compatible with one another.
B. Coordinate installation of anchorages for railings. Furnish setting drawings, templates, and
directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items
with integral anchors, that are to be embedded in concrete or masonry. Deliver such items to
Project site in time for installation.
C. Schedule installation so wall attachments are made only to completed walls. Do not support
railings temporarily by any means that do not satisfy structural performance requirements.
1.4 ACTION SUBMITTALS
A. Product Data: For the following:
1. Manufacturer's product lines of mechanically connected railings.
2. Railing brackets.
3. Grout, anchoring cement, and paint products.
B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.
C. Samples: For each type of exposed finish required.
1. Sections of each distinctly different linear railing member, including handrails, top rails,
posts, and balusters.
2. Fittings and brackets.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
PIPE AND TUBE RAILINGS 055213 - 2
D. Delegated-Design Submittal: For railings, including analysis data signed and sealed by the
qualified professional engineer responsible for their preparation.
1.5 QUALITY ASSURANCE
A. Welding Qualifications: Qualify procedures and personnel according to the following:
1. AWS D1.2/D1.2M, "Structural Welding Code - Aluminum."
1.6 DELIVERY, STORAGE, AND HANDLING
A. Protect mechanical finishes on exposed surfaces from damage by applying a strippable,
temporary protective covering before shipping.
1.7 FIELD CONDITIONS
A. Field Measurements: Verify actual locations of walls and other construction contiguous with
metal fabrications by field measurements before fabrication.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Aluminum Pipe and Tube Railings:
1. Manufacturers: Subject to compliance with requirements, available manufacturers
offering products that may be incorporated into the Work include, but are not limited to,
the following:
a.Blum, Julius & Co., Inc.
b.CraneVeyor Corp.
c.Superior Aluminum Products, Inc.
d.Thompson Fabricating, LLC.
e.Tri Tech, Inc.
f.Tubular Specialties Manufacturing, Inc.
g.Wagner, R & B, Inc.
B. Source Limitations: Obtain each type of railing from single source from single manufacturer.
2.2 PERFORMANCE REQUIREMENTS
A. Delegated Design: Engage a qualified professional engineer to design railings, including
attachment to building construction.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
PIPE AND TUBE RAILINGS 055213 - 3
B. Structural Performance: Railings, including attachment to building construction, shall
withstand the effects of gravity loads and the following loads and stresses within limits and
under conditions indicated:
1. Handrails and Top Rails of Guards:
a. Uniform load of 50 lbf/ ft. applied in any direction.
b. Concentrated load of 200 lbf applied in any direction.
c. Uniform and concentrated loads need not be assumed to act concurrently.
2. Infill of Guards:
a. Concentrated load of 50 lbf applied horizontally on an area of 1 sq. ft..
b. Infill load and other loads need not be assumed to act concurrently.
C. Thermal Movements: Allow for thermal movements from ambient and surface temperature
changes.
1. Temperature Change: 120 deg F, ambient; 180 deg F.
2.3 METALS, GENERAL
A. Metal Surfaces, General: Provide materials with smooth surfaces, without seam marks, roller
marks, rolled trade names, stains, discolorations, or blemishes.
B. Brackets, Flanges, and Anchors: Cast or formed metal of same type of material and finish as
supported rails unless otherwise indicated.
1. Provide type of bracket with flange tapped for concealed anchorage to threaded hanger
bolt and that provides 1-1/2-inch clearance from inside face of handrail to finished wall
surface.
2.4 ALUMINUM
A. Aluminum, General: Provide alloy and temper recommended by aluminum producer and
finisher for type of use and finish indicated, and with not less than the strength and durability
properties of alloy and temper designated below for each aluminum form required.
B. Extruded Bars and Tubing: ASTM B 221, Alloy 6063-T5/T52.
C. Extruded Structural Pipe and Round Tubing: ASTM B 429/B 429M, Alloy 6063-T6.
1. Provide Standard Weight (Schedule 40) pipe unless otherwise indicated.
D. Drawn Seamless Tubing: ASTM B 210, Alloy 6063-T832.
2.5 FASTENERS
A. General: Provide the following:
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
PIPE AND TUBE RAILINGS 055213 - 4
1. Stainless-Steel Railings: Type 304 stainless-steel fasteners.
B. Fasteners for Anchoring Railings to Other Construction: Select fasteners of type, grade, and
class required to produce connections suitable for anchoring railings to other types of
construction indicated and capable of withstanding design loads.
C. Fasteners for Interconnecting Railing Components:
1. Provide concealed fasteners for interconnecting railing components and for attaching
them to other work, unless otherwise indicated.
2. Provide tamper-resistant flat-head machine screws for exposed fasteners unless otherwise
indicated.
D. Post-Installed Anchors: Torque-controlled expansion anchors or chemical anchors capable of
sustaining, without failure, a load equal to 6 times the load imposed when installed in unit
masonry and 4 times the load imposed when installed in concrete, as determined by testing
according to ASTM E 488/E 488M, conducted by a qualified independent testing agency.
1. Material for Exterior Locations: Alloy Group 1 stainless-steel bolts, ASTM F 593, and
nuts, ASTM F 594.
2.6 MISCELLANEOUS MATERIALS
A. Welding Rods and Bare Electrodes: Select according to AWS specifications for metal alloy
welded.
1. For aluminum railings, provide type and alloy as recommended by producer of metal to
be welded and as required for color match, strength, and compatibility in fabricated
items.
B. Nonshrink, Nonmetallic Grout: Factory-packaged, nonstaining, noncorrosive, nongaseous
grout complying with ASTM C 1107/C 1107M. Provide grout specifically recommended by
manufacturer for interior and exterior applications.
2.7 FABRICATION
A. General: Fabricate railings to comply with requirements indicated for design, dimensions,
member sizes and spacing, details, finish, and anchorage, but not less than that required to
support structural loads.
B. Shop assemble railings to greatest extent possible to minimize field splicing and assembly.
Disassemble units only as necessary for shipping and handling limitations. Clearly mark units
for reassembly and coordinated installation. Use connections that maintain structural value of
joined pieces.
C. Cut, drill, and punch metals cleanly and accurately. Remove burrs and ease edges to a radius
of approximately 1/32 inch unless otherwise indicated. Remove sharp or rough areas on
exposed surfaces.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
PIPE AND TUBE RAILINGS 055213 - 5
D. Form work true to line and level with accurate angles and surfaces.
E. Fabricate connections that are exposed to weather in a manner that excludes water. Provide
weep holes where water may accumulate.
F. Cut, reinforce, drill, and tap as indicated to receive finish hardware, screws, and similar items.
G. Connections: Fabricate railings with either welded or nonwelded connections unless otherwise
indicated.
H. Welded Connections: Cope components at connections to provide close fit, or use fittings
designed for this purpose. Weld all around at connections, including at fittings.
1. Use materials and methods that minimize distortion and develop strength and corrosion
resistance of base metals.
2. Obtain fusion without undercut or overlap.
3. Remove flux immediately.
4. At exposed connections, finish exposed surfaces smooth and blended so no roughness
shows after finishing and welded surface matches contours of adjoining surfaces.
I. Nonwelded Connections: Connect members with concealed mechanical fasteners and fittings.
Fabricate members and fittings to produce flush, smooth, rigid, hairline joints.
1. Fabricate splice joints for field connection using an epoxy structural adhesive if this is
manufacturer's standard splicing method.
J. Form Changes in Direction as Follows:
1. By bending or by inserting prefabricated elbow fittings.
K. For changes in direction made by bending, use jigs to produce uniform curvature for each
repetitive configuration required. Maintain cross section of member throughout entire bend
without buckling, twisting, cracking, or otherwise deforming exposed surfaces of components.
L. Close exposed ends of railing members with prefabricated end fittings.
M. Provide wall returns at ends of wall-mounted handrails unless otherwise indicated. Close ends
of returns unless clearance between end of rail and wall is 1/4 inchor less.
N. Brackets, Flanges, Fittings, and Anchors: Provide brackets, flanges, miscellaneous fittings,
and anchors to interconnect railing members to other work unless otherwise indicated.
O. Provide inserts and other anchorage devices for connecting railings to concrete or masonry
work. Fabricate anchorage devices capable of withstanding loads imposed by railings.
Coordinate anchorage devices with supporting structure.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
PIPE AND TUBE RAILINGS 055213 - 6
2.8 ALUMINUM FINISHES
A. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are
acceptable if they are within one-half of the range of approved Samples. Noticeable variations
in the same piece are unacceptable. Variations in appearance of other components are
acceptable if they are within the range of approved Samples and are assembled or installed to
minimize contrast.
B. Clear Anodic Finish: AAMA 611, AA-M12C22A41.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Fit exposed connections together to form tight, hairline joints.
B. Perform cutting, drilling, and fitting required for installing railings. Set railings accurately in
location, alignment, and elevation; measured from established lines and levels and free of rack.
1. Do not weld, cut, or abrade surfaces of railing components that are coated or finished
after fabrication and that are intended for field connection by mechanical or other means
without further cutting or fitting.
2. Set posts plumb within a tolerance of 1/16 inch in 3 feet.
3. Align rails so variations from level for horizontal members and variations from parallel
with rake of steps and ramps for sloping members do not exceed 1/4 inch in 12 feet.
C. Control of Corrosion: Prevent galvanic action and other forms of corrosion by insulating
metals and other materials from direct contact with incompatible materials.
1. Coat, with a heavy coat of bituminous paint, concealed surfaces of aluminum that are in
contact with grout, concrete, masonry, wood, or dissimilar metals.
D. Adjust railings before anchoring to ensure matching alignment at abutting joints.
E. Fastening to In-Place Construction: Use anchorage devices and fasteners where necessary for
securing railings and for properly transferring loads to in-place construction.
3.2 RAILING CONNECTIONS
A. Nonwelded Connections: Use mechanical or adhesive joints for permanently connecting
railing components. Seal recessed holes of exposed locking screws using plastic cement filler
colored to match finish of railings.
B. Welded Connections: Use fully welded joints for permanently connecting railing components.
Comply with requirements for welded connections in "Fabrication" Article whether welding is
performed in the shop or in the field.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
PIPE AND TUBE RAILINGS 055213 - 7
3.3 ANCHORING POSTS
A. Anchor posts to surfaces with flanges, angle type, or floor type as required by conditions,
connected to posts and to metal supporting members as follows:
1. For aluminum pipe railings, attach posts using fittings designed and engineered for this
purpose.
3.4 ADJUSTING AND CLEANING
A. Clean aluminum by washing thoroughly with clean water and soap and rinsing with clean
water.
3.5 PROTECTION
A. Protect finishes of railings from damage during construction period with temporary protective
coverings approved by railing manufacturer. Remove protective coverings at time of
Substantial Completion.
END OF SECTION 055213
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 1
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes hollow-metal work.
B. Related Requirements:
1. Section 087100 "Door Hardware" for door hardware for hollow-metal doors.
1.3 DEFINITIONS
A. Minimum Thickness: Minimum thickness of base metal without coatings according to
NAAMM-HMMA 803 or SDI A250.8.
1.4 COORDINATION
A. Coordinate anchorage installation for hollow-metal frames. Furnish setting drawings, templates,
and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and
items with integral anchors. Deliver such items to Project site in time for installation.
1.5 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. Include construction details, material descriptions, core descriptions, fire-resistance
ratings as scheduled, temperature-rise ratings if required, and finishes.
B. Shop Drawings: Include the following:
1. Elevations of each door type.
2. Details of doors, including vertical- and horizontal-edge details and metal thicknesses.
3. Frame details for each frame type, including dimensioned profiles and metal thicknesses.
4. Locations of reinforcement and preparations for hardware.
5. Details of each different wall opening condition.
6. Details of anchorages, joints, field splices, and connections.
7. Details of accessories.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 2
8. Details of moldings, removable stops, and glazing.
9. Details of conduit and preparations for power, signal, and control systems.
C. Schedule: Provide a schedule of hollow-metal work prepared by or under the supervision of
supplier, using same reference numbers for details and openings as those on Drawings.
Coordinate with final Door Hardware Schedule.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver hollow-metal work palletized, packaged, or crated to provide protection during transit
and Project-site storage. Do not use nonvented plastic.
1. Provide additional protection to prevent damage to factory-finished units.
B. Deliver welded frames with two removable spreader bars across bottom of frames, tack welded
to jambs and mullions.
C. Store hollow-metal work vertically under cover at Project site with head up. Place on minimum
4-inch- high wood blocking. Provide minimum 1/4-inch space between each stacked door to
permit air circulation.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A.Manufacturers: Subject to compliance with requirements, available manufacturers offering
products that may be incorporated into the Work include, but are not limited to, the following:
1.Ceco Door; ASSA ABLOY.
2.Curries Company; ASSA ABLOY.
3.Deansteel Manufacturing Company, Inc..
4.Door Components, Inc.
5.Hollow Metal Xpress.
6.Mesker Door Inc.
7.MPI Group, LLC (The).
8.Pioneer Industries, Inc.
9.Republic Doors and Frames.
10.Security Metal Products Corp.
11.Steelcraft; an Ingersoll-Rand company.
B. Source Limitations: Obtain hollow-metal work from single source from single manufacturer.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 3
2.2 REGULATORY REQUIREMENTS
A. Fire-Rated Assemblies: Complying with NFPA 80 and listed and labeled by a qualified testing
agency acceptable to authorities having jurisdiction for fire-protection ratings and
temperature-rise limits indicated, based on testing at positive pressure according to NFPA 252
or UL 10C.
2.3 INTERIOR DOORS AND FRAMES
A. Construct interior doors and frames to comply with the standards indicated for materials,
fabrication, hardware locations, hardware reinforcement, tolerances, and clearances, and as
specified.
B. Extra-Heavy-Duty Doors and Frames: SDI A250.8, Level 3. At locations indicated in the Door
and Frame Schedule.
1. Physical Performance: Level A according to SDI A250.4.
2. Doors:
a. Type: As indicated in the Door and Frame Schedule.
b. Thickness: 1-3/4 inches.
c. Face: Uncoated, cold-rolled steel sheet, minimum thickness of 0.053 inch.
d. Edge Construction: Model 2, Seamless or Model 3, Stile and Rail, as detailed.
3. Frames:
a. Materials: Uncoated, steel sheet, minimum thickness of 0.053 inch.
b. Sidelite and Transom Frames: Fabricated from same thickness material as adjacent
door frame.
c. Construction: Full profile welded.
4. Exposed Finish: Prime.
2.4 FRAME ANCHORS
A. Jamb Anchors:
1. Masonry Type: Adjustable strap-and-stirrup or T-shaped anchors to suit frame size, not
less than 0.042 inch thick, with corrugated or perforated straps not less than 2 inches
wide by 10 inches long; or wire anchors not less than 0.177 inch thick.
2. Stud-Wall Type: Designed to engage stud, welded to back of frames; not less than 0.042
inch thick.
3. Postinstalled Expansion Type for In-Place Concrete or Masonry: Minimum 3/8-inch-
diameter bolts with expansion shields or inserts. Provide pipe spacer from frame to wall,
with throat reinforcement plate, welded to frame at each anchor location.
B. Floor Anchors: Formed from same material as frames, minimum thickness of 0.042 inch, and
as follows:
1. Monolithic Concrete Slabs: Clip-type anchors, with two holes to receive fasteners.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 4
2.5 MATERIALS
A. Recycled Content of Steel Products: Postconsumer recycled content plus one-half of
preconsumer recycled content not less than 25 percent.
B. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B; suitable
for exposed applications.
C. Hot-Rolled Steel Sheet: ASTM A 1011/A 1011M, Commercial Steel (CS), Type B; free of
scale, pitting, or surface defects; pickled and oiled.
D. Frame Anchors: ASTM A 879/A 879M, Commercial Steel (CS), 04Z coating designation; mill
phosphatized.
E. Inserts, Bolts, and Fasteners: Hot-dip galvanized according to ASTM A 153/A 153M.
F. Powder-Actuated Fasteners in Concrete: Fastener system of type suitable for application
indicated, fabricated from corrosion-resistant materials, with clips or other accessory devices
for attaching hollow-metal frames of type indicated.
G. Grout: ASTM C 476, except with a maximum slump of 4 inches, as measured according to
ASTM C 143/C 143M.
H. Mineral-Fiber Insulation: ASTM C 665, Type I (blankets without membrane facing); consisting
of fibers manufactured from slag or rock wool; with maximum flame-spread and
smoke-developed indexes of 25 and 50, respectively; passing ASTM E 136 for combustion
characteristics.
I. Glazing: Comply with requirements in Section 088813 "Fire-Resistant Glazing."
J. Bituminous Coating: Cold-applied asphalt mastic, compounded for 15-mil dry film thickness
per coat. Provide inert-type noncorrosive compound free of asbestos fibers, sulfur components,
and other deleterious impurities.
2.6 FABRICATION
A. Fabricate hollow-metal work to be rigid and free of defects, warp, or buckle. Accurately form
metal to required sizes and profiles, with minimum radius for metal thickness. Where practical,
fit and assemble units in manufacturer's plant. To ensure proper assembly at Project site, clearly
identify work that cannot be permanently factory assembled before shipment.
B. Hollow-Metal Doors:
1. Steel-Stiffened Door Cores: Provide minimum thickness 0.026 inch, steel vertical
stiffeners of same material as face sheets extending full-door height, with vertical webs
spaced not more than 6 inches apart. Spot weld to face sheets no more than 5 inches o.c.
Fill spaces between stiffeners with glass- or mineral-fiber insulation.
2. Vertical Edges for Single-Acting Doors: Bevel edges 1/8 inch in 2 inches.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 5
3. Top Edge Closures: Close top edges of doors with inverted closures, except provide flush
closures at exterior doors of same material as face sheets.
4. Bottom Edge Closures: Close bottom edges of doors with end closures or channels of
same material as face sheets.
5. Exterior Doors: Provide weep-hole openings in bottoms of exterior doors to permit
moisture to escape. Seal joints in top edges of doors against water penetration.
C. Hollow-Metal Frames: Where frames are fabricated in sections due to shipping or handling
limitations, provide alignment plates or angles at each joint, fabricated of same thickness metal
as frames.
1. Sidelite and Transom Bar Frames: Provide closed tubular members with no visible face
seams or joints, fabricated from same material as door frame. Fasten members at
crossings and to jambs by butt welding.
2. Provide countersunk, flat- or oval-head exposed screws and bolts for exposed fasteners
unless otherwise indicated.
3. Grout Guards: Weld guards to frame at back of hardware mortises in frames to be
grouted.
4. Floor Anchors: Weld anchors to bottoms of jambs with at least four spot welds per
anchor; however, for slip-on drywall frames, provide anchor clips or countersunk holes at
bottoms of jambs.
5. Jamb Anchors: Provide number and spacing of anchors as follows:
a. Masonry Type: Locate anchors not more than 16 inches from top and bottom of
frame. Space anchors not more than 32 inches o.c., to match coursing, and as
follows:
1) Two anchors per jamb up to 60 inches high.
2) Three anchors per jamb from 60 to 90 inches high.
b. Stud-Wall Type: Locate anchors not more than 18 inches from top and bottom of
frame. Space anchors not more than 32 inches o.c. and as follows:
1) Three anchors per jamb up to 60 inches high.
2) Four anchors per jamb from 60 to 90 inches high.
c. Compression Type: Not less than two anchors in each frame.
d. Postinstalled Expansion Type: Locate anchors not more than 6 inches from top and
bottom of frame. Space anchors not more than 26 inches o.c.
6. Head Anchors: Two anchors per head for frames more than 42 inches wide and mounted
in metal-stud partitions.
7. Door Silencers: Except on weather-stripped frames, drill stops to receive door silencers
as follows. Keep holes clear during construction.
a. Single-Door Frames: Drill stop in strike jamb to receive three door silencers.
D. Fabricate concealed stiffeners and edge channels from either cold- or hot-rolled steel sheet.
E. Hardware Preparation: Factory prepare hollow-metal work to receive templated mortised
hardware; include cutouts, reinforcement, mortising, drilling, and tapping according to SDI
A250.6, the Door Hardware Schedule, and templates.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 6
1. Reinforce doors and frames to receive nontemplated, mortised, and surface-mounted door
hardware.
2. Comply with applicable requirements in SDI A250.6 and BHMA A156.115 for
preparation of hollow-metal work for hardware.
F. Stops and Moldings: Provide stops and moldings around glazed lites and louvers where
indicated. Form corners of stops and moldings with butted or mitered hairline joints.
1. Single Glazed Lites: Provide fixed stops and moldings welded on outside of hollow-metal
work.
2. Provide fixed frame moldings on outside of exterior and interior doors and frames.
3. Provide loose stops and moldings on inside of hollow-metal work.
4. Coordinate rabbet width between fixed and removable stops with glazing and installation
types indicated.
2.7 STEEL FINISHES
A. Prime Finish: Clean, pretreat, and apply manufacturer's standard primer.
1. Shop Primer: Manufacturer's standard, fast-curing, lead- and chromate-free primer
complying with SDI A250.10; recommended by primer manufacturer for substrate;
compatible with substrate and field-applied coatings despite prolonged exposure.
2.8 ACCESSORIES
A. Louvers for Fire-Rated Doors: Metal louvers with fusible link and closing device, listed and
labeled for use in doors with fire-protection rating of 1-1/2 hours and less.
1.Manufacturers: Subject to compliance with requirements, provide products by one of
the following:
a.Air Louvers Inc.
b.Anemostat; a Mestek company.
c.Louvers & Dampers, Inc.; a Mestek company.
2. Metal and Finish: Hot-dip galvanized steel, 0.040 inch thick, with baked-enamel- or
powder-coated finish.
B. Mullions and Transom Bars: Join to adjacent members by welding or rigid mechanical anchors.
C. Grout Guards: Formed from same material as frames, not less than 0.016 inch thick.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 7
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, areas, and conditions, with Installer present, for compliance with
requirements for installation tolerances and other conditions affecting performance of the Work.
B. Examine roughing-in for embedded and built-in anchors to verify actual locations before frame
installation.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Remove welded-in shipping spreaders installed at factory. Restore exposed finish by grinding,
filling, and dressing, as required to make repaired area smooth, flush, and invisible on exposed
faces.
B. Drill and tap doors and frames to receive nontemplated, mortised, and surface-mounted door
hardware.
3.3 INSTALLATION
A. General: Install hollow-metal work plumb, rigid, properly aligned, and securely fastened in
place. Comply with Drawings and manufacturer's written instructions.
B. Hollow-Metal Frames: Install hollow-metal frames for doors, transoms, sidelites, borrowed
lites, and other openings, of size and profile indicated. Comply with SDI A250.11 as required
by standards specified.
1. Set frames accurately in position; plumbed, aligned, and braced securely until permanent
anchors are set. After wall construction is complete, remove temporary braces, leaving
surfaces smooth and undamaged.
a. Where frames are fabricated in sections because of shipping or handling
limitations, field splice at approved locations by welding face joint continuously;
grind, fill, dress, and make splice smooth, flush, and invisible on exposed faces.
b. Install frames with removable stops located on inside of opening.
c. Install door silencers in frames before grouting.
d. Remove temporary braces necessary for installation only after frames have been
properly set and secured.
e. Check plumb, square, and twist of frames as walls are constructed. Shim as
necessary to comply with installation tolerances.
f. Field apply bituminous coating to backs of frames that will be filled with grout
containing antifreezing agents.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
HOLLOW METAL DOORS AND FRAMES 081113 - 8
2. Floor Anchors: Provide floor anchors for each jamb and mullion that extends to floor,
and secure with postinstalled expansion anchors.
a. Floor anchors may be set with powder-actuated fasteners instead of postinstalled
expansion anchors if so indicated and approved on Shop Drawings.
3. Masonry Walls: Coordinate installation of frames to allow for solidly filling space
between frames and masonry with grout.
4. In-Place Concrete or Masonry Construction: Secure frames in place with postinstalled
expansion anchors. Countersink anchors, and fill and make smooth, flush, and invisible
on exposed faces.
5. Installation Tolerances: Adjust hollow-metal door frames for squareness, alignment,
twist, and plumb to the following tolerances:
a. Squareness: Plus or minus 1/16 inch, measured at door rabbet on a line 90 degrees
from jamb perpendicular to frame head.
b. Alignment: Plus or minus 1/16 inch, measured at jambs on a horizontal line parallel
to plane of wall.
c. Twist: Plus or minus 1/16 inch, measured at opposite face corners of jambs on
parallel lines, and perpendicular to plane of wall.
d. Plumbness: Plus or minus 1/16 inch, measured at jambs at floor.
C. Hollow-Metal Doors: Fit hollow-metal doors accurately in frames, within clearances specified
below. Shim as necessary.
1. Non-Fire-Rated Steel Doors:
a. Between Door and Frame Jambs and Head: 1/8 inch plus or minus 1/32 inch.
b. Between Edges of Pairs of Doors: 1/8 inch to 1/4 inch plus or minus 1/32 inch.
c. At Bottom of Door: 5/8 inch plus or minus 1/32 inch.
d. Between Door Face and Stop: 1/16 inch to 1/8 inch plus or minus 1/32 inch.
D. Glazing: Comply with installation requirements in Section 088113 "Fire-Resistant Glazing" and
with hollow-metal manufacturer's written instructions.
1. Secure stops with countersunk flat- or oval-head machine screws spaced uniformly not
more than 9 inches o.c. and not more than 2 inches o.c. from each corner.
3.4 ADJUSTING AND CLEANING
A. Final Adjustments: Check and readjust operating hardware items immediately before final
inspection. Leave work in complete and proper operating condition. Remove and replace
defective work, including hollow-metal work that is warped, bowed, or otherwise unacceptable.
B. Remove grout and other bonding material from hollow-metal work immediately after installation.
C. Prime-Coat Touchup: Immediately after erection, sand smooth rusted or damaged areas of
prime coat and apply touchup of compatible air-drying, rust-inhibitive primer.
END OF SECTION 081113
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FLUSH WOOD DOORS 081416 - 1
SECTION 081416 - FLUSH WOOD DOORS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Solid-core doors with wood-veneer faces.
2. Factory finishing flush wood doors.
3. Factory fitting flush wood doors to frames and factory machining for hardware.
B. Related Requirements:
1. Section 087100 "Door Hardware" for door hardware for hollow-metal doors.
1.3 PREINSTALLATION MEETINGS
A. Preinstallation Conference: Conduct conference at Project site.
1.4 ACTION SUBMITTALS
A. Product Data: For each type of door. Include details of core and edge construction, louvers,
and trim for openings. Include factory-finishing specifications.
B. Shop Drawings: Indicate location, size, and hand of each door; elevation of each kind of door;
construction details not covered in Product Data; and the following:
1. Dimensions and locations of blocking.
2. Dimensions and locations of mortises and holes for hardware.
3. Undercuts.
4. Doors to be factory finished and finish requirements.
C. Samples for Initial Selection:
1. Samples, 4 inches square, for matching factory-finished materials to existing doors.
a. Special Instructions: Provide samples to Owner and Architect for separate review.
D. Samples for Verification:
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FLUSH WOOD DOORS 081416 - 2
1. Factory finishes applied to actual door face materials, approximately 8 by 10 inches, for
each material and finish. For each wood species and transparent finish, provide set of
three Samples showing typical range of color and grain to be expected in finished Work.
a. Special Instructions: Provide samples to Owner and Architect for separate review.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: A qualified manufacturer that is certified for chain of custody by
an FSC-accredited certification body and is a certified participant in AWI's Quality
Certification Program.
B. Vendor Qualifications: A vendor that is certified for chain of custody by an FSC-accredited
certification body.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Comply with requirements of referenced standard and manufacturer's written instructions.
B. Package doors individually in plastic bags or cardboard cartons.
C. Mark each door on bottom rail with opening number used on Shop Drawings.
1.7 FIELD CONDITIONS
A. Environmental Limitations: Do not deliver or install doors until spaces are enclosed and
weathertight, wet work in spaces is complete and dry, and HVAC system is operating and
maintaining ambient temperature and humidity conditions at occupancy levels during
remainder of construction period.
1.8 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace doors that fail in materials or
workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Warping (bow, cup, or twist) more than 1/4 inch in a 42-by-84-inch section.
b. Telegraphing of core construction in face veneers exceeding 0.01 inch in a 3-inch span.
2. Warranty shall also include installation and finishing that may be required due to repair
or replacement of defective doors.
3. Warranty Period for Solid-Core Interior Doors: Life of installation.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FLUSH WOOD DOORS 081416 - 3
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A.Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
1.Algoma Hardwoods, Inc.
2.Eggers Industries.
3.Graham Wood Doors; an Assa Abloy Group company.
4.Marshfield Door Systems, Inc.
5.Oshkosh Door Company.
B. Source Limitations: Obtain flush wood doors from single manufacturer.
2.2 PERFORMANCE REQUIREMENTS
A. Fire-Rated Wood Door Assemblies: Assemblies complying with NFPA 80 that are listed and
labeled by a qualified testing agency acceptable to authorities having jurisdiction, for
fire-protection ratings indicated on Drawings, based on testing at positive pressure in
accordance with UL 10C or NFPA 252.
1. Cores: Provide core specified or mineral core as needed to provide fire-protection rating
indicated.
2. Edge Construction: Provide edge construction with intumescent seals concealed by
outer stile. Comply with specified requirements for exposed edges.
2.3 FLUSH WOOD DOORS, GENERAL
A. Quality Standard: In addition to requirements specified, comply with AWI's, AWMAC's, and
WI's "Architectural Woodwork Standards."
1. Contract Documents contain selections chosen from options in quality standard and
additional requirements beyond those of quality standard. Comply with those selections
and requirements in addition to quality standard.
B. Certified Wood: Flush wood doors shall be certified as "FSC Pure"or "FSC Mixed Credit"
according to FSC STD-01-001, "FSC Principles and Criteria for Forest Stewardship," and to
FSC STD-40-004, "FSC Standard for Chain of Custody Certification."
C. Low-Emitting Materials: Fabricate doors with adhesives and composite wood products that do
not contain urea formaldehyde.
D. Structural-Composite-Lumber-Core Doors:
1. Structural Composite Lumber: WDMA I.S.10.
a. Screw Withdrawal, Face: 700 lbf.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FLUSH WOOD DOORS 081416 - 4
b. Screw Withdrawal, Edge: 400 lbf.
E. Mineral-Core Doors:
1. Core: Noncombustible mineral product complying with requirements of referenced
quality standard and testing and inspecting agency for fire-protection rating indicated.
2. Blocking: Provide composite blocking with improved screw-holding capability
approved for use in doors of fire-protection ratings indicated as needed to eliminate
through-bolting hardware.
3. Edge Construction: At hinge stiles, provide laminated-edge construction with improved
screw-holding capability and split resistance. Comply with specified requirements for
exposed edges.
4. Screw-Holding Capability: 550 lbf per WDMA T.M.-10.
2.4 VENEER-FACED DOORS FOR TRANSPARENT FINISH
1. Grade: Premium, with Grade A faces.
2. Species: Red oak.
3. Cut: Plain sliced (flat sliced).
4. Match between Veneer Leaves: Book match.
5. Assembly of Veneer Leaves on Door Faces: Center-balance match.
6. Pair and Set Match: Provide for doors hung in same opening or separated only by mullions.
7. Room Match: Match door faces within each separate room or area of building.
Corridor-door faces do not need to match where they are separated by 20 feet or more.
8. Exposed Vertical Edges: Same species as faces - edge Type A.
9. Core: Structural composite lumber or mineral-cire.
10. Construction: Five or seven plies. Stiles and rails are bonded to core, then entire unit is
abrasive planed before veneering. Faces are bonded to core using a hot press.
2.5 FABRICATION
A. Factory fit doors to suit frame-opening sizes indicated. Comply with clearance requirements
of referenced quality standard for fitting unless otherwise indicated.
1. Comply with NFPA 80 requirements for fire-rated doors.
B. Factory machine doors for hardware that is not surface applied. Locate hardware to comply
with DHI-WDHS-3. Comply with final hardware schedules, door frame Shop Drawings,
BHMA-156.115-W, and hardware templates.
2.6 FACTORY FINISHING
A. General: Comply with referenced quality standard for factory finishing. Complete
fabrication, including fitting doors for openings and machining for hardware that is not surface
applied, before finishing.
1. Finish faces, all four edges, edges of cutouts, and mortises. Stains and fillers may be
omitted on bottom edges, edges of cutouts, and mortises.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FLUSH WOOD DOORS 081416 - 5
B. Factory finish doors.
C. Transparent Finish:
1. Grade: Premium.
2. Finish: AWI's, AWMAC's, and WI's "Architectural Woodwork Standards" System 5,
conversion varnish or System 11, catalyzed polyurethane.
3. Staining: As selected by Architect from manufacturer's full range.
4. Effect: Open-grain finish.
5. Sheen: Satin.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine doors and installed door frames, with Installer present, before hanging doors.
1. Verify that installed frames comply with indicated requirements for type, size, location,
and swing characteristics and have been installed with level heads and plumb jambs.
2. Reject doors with defects.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Hardware: For installation, see Section 087100 "Door Hardware."
B. Installation Instructions: Install doors to comply with manufacturer's written instructions and
referenced quality standard, and as indicated.
1. Install fire-rated doors according to NFPA 80.
C. Factory-Fitted Doors: Align in frames for uniform clearance at each edge.
D. Factory-Finished Doors: Restore finish before installation if fitting or machining is required at
Project site.
3.3 ADJUSTING
A. Operation: Rehang or replace doors that do not swing or operate freely.
B. Finished Doors: Replace doors that are damaged or that do not comply with requirements.
Doors may be repaired or refinished if Work complies with requirements and shows no
evidence of repair or refinishing.
END OF SECTION 081416
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 1
SECTION 087100 – DOOR HARDWARE
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section includes commercial door hardware for the following:
1. Swinging doors.
B. Door hardware includes, but is not necessarily limited to, the following:
1. Mechanical door hardware.
C. Related Sections:
1. Division 08 Section “Hollow Metal Doors and Frames”.
2. Division 08 Section “Flush Wood Doors”
D. Codes and References: Comply with the version year adopted by the Authority Having
Jurisdiction.
1. ANSI A117.1 - Accessible and Usable Buildings and Facilities.
2. ICC/IBC - International Building Code.
3. NFPA 70 - National Electrical Code.
4. NFPA 80 - Fire Doors and Windows.
5. NFPA 101 - Life Safety Code.
6. NFPA 105 - Installation of Smoke Door Assemblies.
7. State Building Codes, Local Amendments.
E. Standards: All hardware specified herein shall comply with the following industry standards:
1. ANSI/BHMA Certified Product Standards - A156 Series
2. UL10C – Positive Pressure Fire Tests of Door Assemblies
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 2
1.3 SUBMITTALS
A. Product Data: Manufacturer's product data sheets including installation details, material
descriptions, dimensions of individual components and profiles, operational descriptions and
finishes.
B. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing fabrication
and assembly of door hardware, as well as procedures and diagrams. Coordinate the final Door
Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand,
function, and finish of door hardware.
1. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and
Format for the Hardware Schedule."
2. Organization: Organize the Door Hardware Schedule into door hardware sets indicating
complete designations of every item required for each door or opening. Organize door
hardware sets in same order as in the Door Hardware Sets at the end of Part 3. Submittals
that do not follow the same format and order as the Door Hardware Sets will be rejected
and subject to resubmission.
3. Content: Include the following information:
a. Type, style, function, size, label, hand, and finish of each door hardware
item.
b. Manufacturer of each item.
c. Fastenings and other pertinent information.
d. Location of door hardware set, cross-referenced to Drawings, both on floor
plans and in door and frame schedule.
e. Explanation of abbreviations, symbols, and codes contained in schedule.
f. Mounting locations for door hardware.
g. Door and frame sizes and materials.
h. Warranty information for each product.
4. Submittal Sequence: Submit the final Door Hardware Schedule at earliest possible date,
particularly where approval of the Door Hardware Schedule must precede fabrication of
other work that is critical in the Project construction schedule. Include Product Data,
Samples, Shop Drawings of other work affected by door hardware, and other information
essential to the coordinated review of the Door Hardware Schedule.
C. Keying Schedule: After a keying meeting with the owner has taken place prepare a separate
keying schedule detailing final instructions. Submit the keying schedule in electronic format.
Include keying system explanation, door numbers, key set symbols, hardware set numbers and
special instructions. Owner must approve submitted keying schedule prior to the ordering of
permanent cylinders/cores.
D. Operating and Maintenance Manuals: Provide manufacturers operating and maintenance
manuals for each item comprising the complete door hardware installation in quantity as
required in Division 01, Closeout Submittals.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 3
1.4 QUALITY ASSURANCE
A. Manufacturers Qualifications: Engage qualified manufacturers with a minimum 5 years of
documented experience in producing hardware and equipment similar to that indicated for this
Project and that have a proven record of successful in-service performance.
B. Installer Qualifications: A minimum 3 years documented experience installing both standard
and electrified door hardware similar in material, design, and extent to that indicated for this
Project and whose work has resulted in construction with a record of successful in-service
performance.
C. Door Hardware Supplier Qualifications: Experienced commercial door hardware distributors
with a minimum 5 years documented experience supplying both mechanical and
electromechanical hardware installations comparable in material, design, and extent to that
indicated for this Project. Supplier recognized as a factory direct distributor by the
manufacturers of the primary materials with a warehousing facility in Project's vicinity.
Supplier to have on staff a certified Architectural Hardware Consultant (AHC) available during
the course of the Work to consult with Contractor, Architect, and Owner concerning both
standard and electromechanical door hardware and keying.
D. Each unit to bear third party permanent label demonstrating compliance with the referenced
standards.
E. Keying Conference: Conduct conference to comply with requirements in Division 01 Section
"Project Meetings." Keying conference to incorporate the following criteria into the final keying
schedule document:
1. Function of building, purpose of each area and degree of security required.
2. Plans for existing and future key system expansion.
3. Requirements for key control storage and software.
4. Installation of permanent keys, cylinder cores and software.
5. Address and requirements for delivery of keys.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Inventory door hardware on receipt and provide secure lock-up and shelving for door hardware
delivered to Project site. Do not store electronic access control hardware, software or
accessories at Project site without prior authorization.
B. Tag each item or package separately with identification related to the final Door Hardware
Schedule, and include basic installation instructions with each item or package.
C. Deliver, as applicable, permanent keys, cylinders, cores, access control credentials, software
and related accessories directly to Owner via registered mail or overnight package service.
Instructions for delivery to the Owner shall be established at the "Keying Conference".
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 4
1.6 COORDINATION
A. Templates: Obtain and distribute to the parties involved templates for doors, frames, and other
work specified to be factory prepared for installing standard and electrified hardware. Check
Shop Drawings of other work to confirm that adequate provisions are made for locating and
installing hardware to comply with indicated requirements.
B. Door and Frame Preparation: Doors and corresponding frames are to be prepared, reinforced
and pre-wired (if applicable) to receive the installation of the specified electrified, monitoring,
signaling and access control system hardware without additional in-field modifications.
1.7 WARRANTY
A. General Warranty: Reference Division 01, General Requirements. Special warranties specified
in this Article shall not deprive Owner of other rights Owner may have under other provisions
of the Contract Documents and shall be in addition to, and run concurrent with, other warranties
made by Contractor under requirements of the Contract Documents.
B. Warranty Period: Written warranty, executed by manufacturer(s), agreeing to repair or replace
components of standard and electrified door hardware that fails in materials or workmanship
within specified warranty period after final acceptance by the Owner. Failures include, but are
not limited to, the following:
1. Structural failures including excessive deflection, cracking, or breakage.
2. Faulty operation of the hardware.
3. Deterioration of metals, metal finishes, and other materials beyond normal weathering.
4. Electrical component defects and failures within the systems operation.
C. Standard Warranty Period: One year from date of Substantial Completion, unless otherwise
indicated.
D. Special Warranty Periods:
1. Ten years for mortise locks and latches.
2. Five years for exit hardware.
3. Twenty five years for manual surface door closer bodies.
PART 2 - PRODUCTS
2.1 SCHEDULED DOOR HARDWARE
A. General: Provide door hardware for each door to comply with requirements in Door Hardware
Sets and each referenced section that products are to be supplied under.
B. Designations: Requirements for quantity, item, size, finish or color, grade, function, and other
distinctive qualities of each type of door hardware are indicated in the Door Hardware Sets at
the end of Part 3. Products are identified by using door hardware designations, as follows:
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 5
1. Named Manufacturer's Products: Product designation and manufacturer are listed for
each door hardware type required for the purpose of establishing requirements.
Manufacturers' names are abbreviated in the Door Hardware Schedule.
C. Substitutions: Requests for substitution and product approval for inclusive mechanical and
electromechanical door hardware in compliance with the specifications must be submitted in
writing and in accordance with the procedures and time frames outlined in Division 01,
Substitution Procedures. Approval of requests is at the discretion of the architect, owner, and
their designated consultants.
2.2 HANGING DEVICES
A. Hinges: ANSI/BHMA A156.1 certified butt hinges with number of hinge knuckles and other
options as specified in the Door Hardware Sets.
1. Quantity: Provide the following hinge quantity:
a. Two Hinges: For doors with heights up to 60 inches.
b. Three Hinges: For doors with heights 61 to 90 inches.
c. Four Hinges: For doors with heights 91 to 120 inches.
d. For doors with heights more than 120 inches, provide 4 hinges, plus 1 hinge
for every 30 inches of door height greater than 120 inches.
2. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized
for door thickness and clearances required:
a. Widths up to 3’0”: 4-1/2” standard or heavy weight as specified.
b. Sizes from 3’1” to 4’0”: 5” standard or heavy weight as specified.
3. Hinge Weight and Base Material: Unless otherwise indicated, provide the following:
a. Exterior Doors: Heavy weight, non-ferrous, ball bearing or oil impregnated
bearing hinges unless Hardware Sets indicate standard weight.
b. Interior Doors: Standard weight, steel, ball bearing or oil impregnated
bearing hinges unless Hardware Sets indicate heavy weight.
4. Hinge Options: Comply with the following:
a. Non-removable Pins: Provide set screw in hinge barrel that, when tightened
into a groove in hinge pin, prevents removal of pin while door is closed; for
the all out-swinging lockable doors.
5. Manufacturers:
a. Bommer Industries (BO).
b. Hager Companies (HA).
c. McKinney Products; ASSA ABLOY Architectural Door Accessories (MK).
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 6
2.3 CYLINDERS AND KEYING
A. General: Cylinder manufacturer to have minimum (10) years experience designing secured
master key systems and have on record a published security keying system policy.
1. Manufacturers:
a. Sargent Manufacturing (SA).
b. No Substitution.
B. Cylinders: Original manufacturer cylinders complying with the following:
1. Mortise Type: Threaded cylinders with rings and cams to suit hardware application.
2. Rim Type: Cylinders with back plate, flat-type vertical or horizontal tailpiece, and raised
trim ring.
3. Bored-Lock Type: Cylinders with tailpieces to suit locks.
4. Mortise and rim cylinder collars to be solid and recessed to allow the cylinder face to be
flush and be free spinning with matching finishes.
5. Keyway: Match Facility Standard.
C. Keying System: Each type of lock and cylinders to be factory keyed.
1. Conduct specified "Keying Conference" to define and document keying system
instructions and requirements.
2. Furnish factory cut, nickel-silver large bow permanently inscribed with a visual key
control number as directed by Owner.
3. Existing System: Key locks to Owner's existing system.
D. Key Quantity: Provide the following minimum number of keys:
1. Change Keys per Cylinder: Two (2)
2. Master Keys (per Master Key Level/Group): Five (5).
3. Construction Keys (where required): Ten (10).
E. Construction Keying: Provide construction master keyed cylinders.
F. Key Registration List (Bitting List):
1. Provide transcript list in writing or electronic file as directed by the Owner.
2.4 MECHANICAL LOCKS AND LATCHING DEVICES
A. Mortise Locksets, Grade 1 (Heavy Duty): ANSI/BHMA A156.13, Series 1000, Operational
Grade 1 certified. Locksets are to be manufactured with a corrosion resistant steel case and be
field-reversible for handing without disassembly of the lock body.
1. Manufacturers:
a. Sargent Manufacturing (SA) – 8200 Series.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 7
b. No Substitution.
2.5 LOCK AND LATCH STRIKES
A. Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with
curved lip extended to protect frame, finished to match door hardware set, unless otherwise
indicated, and as follows:
1. Flat-Lip Strikes: For locks with three-piece antifriction latchbolts, as recommended by
manufacturer.
B. Standards: Comply with the following:
1. Strikes for Mortise Locks and Latches: BHMA A156.13.
2.6 CONVENTIONAL EXIT DEVICES
A. General Requirements: All exit devices specified herein shall meet or exceed the following
criteria:
1. At doors not requiring a fire rating, provide devices complying with NFPA 101 and listed
and labeled for "Panic Hardware" according to UL305. Provide proper fasteners as
required by manufacturer including sex nuts and bolts at openings specified in the
Hardware Sets.
2. Where exit devices are required on fire rated doors, provide devices complying with
NFPA 80 and with UL labeling indicating "Fire Exit Hardware". Provide devices with the
proper fasteners for installation as tested and listed by UL. Consult manufacturer’s
catalog and template book for specific requirements.
3. Lever Operating Trim: Where exit devices require lever trim, furnish manufacturer's
heavy duty escutcheon trim with threaded studs for thru-bolts.
a. Lock Trim Design: As indicated in Hardware Sets, provide finishes and
designs to match that of the specified locksets.
b. Where function of exit device requires a cylinder, provide a cylinder (Rim or
Mortise) as specified in Hardware Sets.
4. Rail Sizing: Provide exit device rails factory sized for proper door width application.
5. Through Bolt Installation: For exit devices and trim as indicated in Door Hardware Sets.
B. Conventional Push Rail Exit Devices (Heavy Duty): ANSI/BHMA A156.3, Grade 1 certified
panic and fire exit hardware devices furnished in the functions specified in the Hardware Sets.
Exit device latch to be stainless steel, pullman type, with deadlock feature.
1. Manufacturers:
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 8
a. Sargent Manufacturing (SA) - 80 Series.
b. Stanley Precision (PR) - Apex 2000 Series.
c. Von Duprin (VD) - 35A/98 XP Series.
2.7 DOOR CLOSERS
A. All door closers specified herein shall meet or exceed the following criteria:
1. General: Door closers to be from one manufacturer, matching in design and style, with
the same type door preparations and templates regardless of application or spring size.
Closers to be non-handed with full sized covers including installation and adjusting
information on inside of cover.
2. Standards: Closers to comply with UL-10C for Positive Pressure Fire Test and be U.L.
listed for use of fire rated doors.
3. Cycle Testing: Provide closers which have surpassed 10 million cycles in a test witnessed
and verified by UL.
4. Size of Units: Comply with manufacturer's written recommendations for sizing of door
closers depending on size of door, exposure to weather, and anticipated frequency of use.
Where closers are indicated for doors required to be accessible to the physically
handicapped, provide units complying with ANSI ICC/A117.1.
5. Closer Arms: Provide heavy duty, forged steel closer arms unless otherwise indicated in
Hardware Sets.
6. Closers shall not be installed on exterior or corridor side of doors; where possible install
closers on door for optimum aesthetics.
7. Closer Accessories: Provide door closer accessories including custom templates, special
mounting brackets, spacers and drop plates as required for proper installation. Provide
through-bolt and security type fasteners as specified in the hardware sets.
B. Door Closers, Surface Mounted (Heavy Duty): ANSI/BHMA A156.4, Grade 1 surface
mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6; and
fully operational adjustable according to door size, frequency of use, and opening force. Closers
to be rack and pinion type, one piece cast iron or aluminum alloy body construction, with
adjustable backcheck and separate non-critical valves for closing sweep and latch speed control.
Provide non-handed units standard.
1. Manufacturers:
a. LCN Closers (LC) - 4040 Series.
b. Sargent Manufacturing (SA) - 351 Series.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 9
2.8 ARCHITECTURAL TRIM
A. Door Protective Trim
1. General: Door protective trim units to be of type and design as specified below or in the
Hardware Sets.
2. Size: Fabricate protection plates (kick, armor, or mop) not more than 2" less than door
width (LDW) on stop side of single doors and 1” LDW on stop side of pairs of doors, and
not more than 1" less than door width on pull side. Coordinate and provide proper width
and height as required where conflicting hardware dictates. Height to be as specified in
the Hardware Sets.
3. Where plates are applied to fire rated doors with the top of the plate more than 16” above
the bottom of the door, provide plates complying with NFPA 80. Consult manufacturer’s
catalog and template book for specific requirements for size and applications.
4. Protection Plates: ANSI/BHMA A156.6 certified protection plates (kick, armor, or mop),
fabricated from the following:
a. Stainless Steel: 300 grade, 050-inch thick.
5. Options and fasteners: Provide manufacturer's designated fastener type as specified in the
Hardware Sets. Provide countersunk screw holes.
6. Manufacturers:
a. Burns Manufacturing (BU).
b. Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).
c. Trimco (TC).
2.9 DOOR STOPS AND HOLDERS
A. General: Door stops and holders to be of type and design as specified below or in the Hardware
Sets.
B. Door Stops and Bumpers: ANSI/BHMA A156.16, Grade 1 certified door stops and wall
bumpers. Provide wall bumpers, either convex or concave types with anchorage as indicated,
unless floor or other types of door stops are specified in Hardware Sets. Do not mount floor
stops where they will impede traffic. Where floor or wall bumpers are not appropriate, provide
overhead type stops and holders.
1. Manufacturers:
a. Burns Manufacturing (BU).
b. Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).
c. Trimco (TC).
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 10
2.10 ARCHITECTURAL SEALS
A. General: Thresholds, weatherstripping, and gasket seals to be of type and design as specified
below or in the Hardware Sets. Provide continuous weatherstrip gasketing on exterior doors and
provide smoke, light, or sound gasketing on interior doors where indicated. At exterior
applications provide non-corrosive fasteners and elsewhere where indicated.
B. Smoke Labeled Gasketing: Assemblies complying with NFPA 105 that are listed and labeled by
a testing and inspecting agency acceptable to authorities having jurisdiction, for smoke control
ratings indicated, based on testing according to UL 1784.
1. Provide smoke labeled perimeter gasketing at all smoke labeled openings.
C. Fire Labeled Gasketing: Assemblies complying with NFPA 80 that are listed and labeled by a
testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings
indicated, based on testing according to UL-10C.
1. Provide intumescent seals as indicated to meet UL10C Standard for Positive Pressure
Fire Tests of Door Assemblies, and NPFA 252, Standard Methods of Fire Tests of Door
Assemblies.
D. Sound-Rated Gasketing: Assemblies that are listed and labeled by a testing and inspecting
agency, for sound ratings indicated.
E. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are easily
replaceable and readily available from stocks maintained by manufacturer.
F. Manufacturers:
1. National Guard Products (NG).
2. Pemko Products; ASSA ABLOY Architectural Door Accessories (PE).
3. Reese Enterprises, Inc. (RE).
2.11 FABRICATION
A. Fasteners: Provide door hardware manufactured to comply with published templates generally
prepared for machine, wood, and sheet metal screws. Provide screws according to
manufacturers recognized installation standards for application intended.
2.12 FINISHES
A. Standard: Designations used in the Hardware Sets and elsewhere indicate hardware finishes
complying with ANSI/BHMA A156.18, including coordination with traditional U.S. finishes
indicated by certain manufacturers for their products.
B. Provide quality of finish, including thickness of plating or coating (if any), composition,
hardness, and other qualities complying with manufacturer's standards, but in no case less than
specified by referenced standards for the applicable units of hardware
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 11
C. Protect mechanical finishes on exposed surfaces from damage by applying a strippable,
temporary protective covering before shipping.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine scheduled openings, with Installer present, for compliance with requirements for
installation tolerances, labeled fire door assembly construction, wall and floor construction, and
other conditions affecting performance.
B. Notify architect of any discrepancies or conflicts between the door schedule, door types,
drawings and scheduled hardware. Proceed only after such discrepancies or conflicts have been
resolved in writing.
3.2 PREPARATION
A. Hollow Metal Doors and Frames: Comply with ANSI/DHI A115 series.
B. Wood Doors: Comply with ANSI/DHI A115-W series.
3.3 INSTALLATION
A. Install each item of mechanical and electromechanical hardware and access control equipment
to comply with manufacturer's written instructions and according to specifications.
1. Installers are to be trained and certified by the manufacturer on the proper installation and
adjustment of fire, life safety, and security products including: hanging devices; locking
devices; closing devices; and seals.
B. Mounting Heights: Mount door hardware units at heights indicated in following applicable
publications, unless specifically indicated or required to comply with governing regulations:
1. Standard Steel Doors and Frames: DHI's "Recommended Locations for Architectural
Hardware for Standard Steel Doors and Frames."
2. Wood Doors: DHI WDHS.3, "Recommended Locations for Architectural Hardware for
Wood Flush Doors."
3. Where indicated to comply with accessibility requirements, comply with ANSI A117.1
"Accessibility Guidelines for Buildings and Facilities."
4. Provide blocking in drywall partitions where wall stops or other wall mounted hardware
is located.
C. Retrofitting: Install door hardware to comply with manufacturer's published templates and
written instructions. Where cutting and fitting are required to install door hardware onto or into
surfaces that are later to be painted or finished in another way, coordinate removal, storage, and
reinstallation of surface protective trim units with finishing work specified in Division 9
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 12
Sections. Do not install surface-mounted items until finishes have been completed on substrates
involved.
D. Thresholds: Set thresholds for exterior and acoustical doors in full bed of sealant complying
with requirements specified in Division 7 Section "Joint Sealants."
E. Storage: Provide a secure lock up for hardware delivered to the project but not yet installed.
Control the handling and installation of hardware items so that the completion of the work will
not be delayed by hardware losses before and after installation.
3.4 FIELD QUALITY CONTROL
A. Field Inspection: Supplier will perform a final inspection of installed door hardware and state in
report whether work complies with or deviates from requirements, including whether door
hardware is properly installed, operating and adjusted.
3.5 ADJUSTING
A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to
ensure proper operation or function of every unit. Replace units that cannot be adjusted to
operate as intended. Adjust door control devices to compensate for final operation of heating
and ventilating equipment and to comply with referenced accessibility requirements.
3.6 CLEANING AND PROTECTION
A. Protect all hardware stored on construction site in a covered and dry place. Protect exposed
hardware installed on doors during the construction phase. Install any and all hardware at the
latest possible time frame.
B. Clean adjacent surfaces soiled by door hardware installation.
C. Clean operating items as necessary to restore proper finish. Provide final protection and
maintain conditions that ensure door hardware is without damage or deterioration at time of
owner occupancy.
3.7 DOOR HARDWARE SETS
A. The hardware sets represent the design intent and direction of the owner and architect. They are
a guideline only and should not be considered a detailed hardware schedule. Discrepancies,
conflicting hardware and missing items should be brought to the attention of the architect with
corrections made prior to the bidding process. Omitted items not included in a hardware set
should be scheduled with the appropriate additional hardware required for proper application
and functionality.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 13
B. The supplier is responsible for handing and sizing all products and providing the correct option
for the appropriate door type and material where more than one is presented in the hardware
sets. Quantities listed are for each pair of doors, or for each single door.
C. Manufacturer’s Abbreviations:
1. MK - McKinney
2. SA - Sargent
3. RO - Rockwood
4. PE - Pemko
Hardware Sets
Set: 1.0
Doors: 114, G07
3 Hinge As Required US26D MK
1 Office Lock 60 8205 LNL US26D SA
1 Door Closer 351 UO EN SA
1 Kick Plate K1050 6" high US32D RO
1 Wall Stop 406 EN RO
1 Gasketing S773 BL PE
Set: 2.0
Doors: 10042, G0044
3 Hinge As Required US26D MK
1 Exit Device (classroom) 12 60 8813 ETL US32D SA
1 Door Closer 351 UO EN SA
1 Kick Plate K1050 6" high US32D RO
1 Wall Stop 406 EN RO
1 Gasketing S773 BL PE
Notes: Reuse existing magnetic hold open
Set: 3.0
Doors: G0002, G06
3 Hinge As Required US26D MK
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
DOOR HARDWARE 087100 - 14
1 Exit Device (classroom) 12 60 8813 ETL US32D SA
1 Door Closer 351 UO EN SA
1 Kick Plate K1050 6" high US32D RO
1 Wall Stop 406 EN RO
1 Gasketing S773 BL PE
Set: 4.0
Doors: 101, 108, 109, 110, 113, 120A, 200, 201, 208, 210, 214
3 Hinge As Required US26D MK
1 Dormitory/Exit Lock 60 8225 LNL US26D SA
1 Door Closer 351 UO EN SA
1 Kick Plate K1050 6" high US32D RO
1 Wall Stop 406 EN RO
1 Gasketing S773 BL PE
Set: 5.0
Doors: 102, 103, 104, 105, 106, 107, 111, 112, 202, 203, 204, 205, 206, 207, 209, 211, 212, 213
3 Hinge As Required US26D MK
1 Dormitory/Exit Lock 60 8225 LNL US26D SA
1 Door Closer 351 UO EN SA
1 Kick Plate K1050 6" high US32D RO
1 Door Stop 441CU US26D RO
1 Gasketing S773 BL PE
Set: 6.0
Doors: 10060, 115, 116, 121, 20060, G0042, G0043, G0060, G02, G03, G05A
1 Core 6300 US15 SA
END OF SECTION 087100
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 1
SECTION 088813 - FIRE-RESISTANT GLAZING
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Fire-protection-rated glazing.
1.3 DEFINITIONS
A. Glass Manufacturers: Firms that produce primary glass, fabricated glass, or both, as defined in
referenced glazing publications.
B. Glass Thicknesses: Indicated by thickness designations in millimeters according to ASTM C 1036.
1.4 COORDINATION
A. Coordinate glazing channel dimensions to provide necessary bite on glass, minimum edge and
face clearances, and adequate sealant thicknesses, with reasonable tolerances.
1.5 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Glass Samples: For each type of glass product; 12 inches square.
C. Glazing Schedule: List glass types and thicknesses for each size opening and location. Use
same designations indicated on Drawings.
1.6 QUALITY ASSURANCE
A. Installer Qualifications: A qualified installer who employs glass installers for this Project who
are certified under the National Glass Association's Certified Glass Installer Program.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 2
1.7 DELIVERY, STORAGE, AND HANDLING
A. Protect glazing materials according to manufacturer's written instructions. Prevent damage to
glass and glazing materials from condensation, temperature changes, direct exposure to sun, or
other causes.
1.8 FIELD CONDITIONS
A. Environmental Limitations: Do not deliver or install fire-resistant glazing until spaces are
enclosed and weathertight and temporary HVAC system is operating and maintaining ambient
temperature conditions at occupancy levels during the remainder of the construction period.
1.9 WARRANTY
A. Manufacturer's Special Warranty on Laminated Glass: Manufacturer agrees to replace
laminated-glass units that deteriorate within specified warranty period. Deterioration of
laminated glass is defined as defects developed from normal use that are not attributed to glass
breakage or to maintaining and cleaning laminated glass contrary to manufacturer's written
instructions. Defects include edge separation, delamination materially obstructing vision
through glass, and blemishes exceeding those allowed by referenced laminated-glass standard.
1. Warranty Period: Five years from date of Substantial Completion.
B. Manufacturer's Special Warranty on Double Glazing Units with Clear Gel Fill: Manufacturer
agrees to replace units that deteriorate within specified warranty period. Deterioration of double
glazing units with clear gel fill is defined as failure of hermetic seal under normal use that is not
attributed to glass breakage or to maintaining and cleaning glass contrary to manufacturer's
written instructions. Evidence of failure is the leakage of gel fill from units, air bubbles within
units, or obstruction of vision by contamination or deterioration of gel.
1. Warranty Period: 10 years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations for Glass: Obtain from single source from single manufacturer for each
glass type.
B. Source Limitations for Glazing Accessories: Obtain from single source from single
manufacturer for each product and installation method.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 3
2.2 PERFORMANCE REQUIREMENTS
A. General: Installed glazing systems shall withstand normal thermal movement and impact loads
(where applicable) without failure, including loss or glass breakage attributable to the
following: defective manufacture, fabrication, or installation; deterioration of glazing materials;
or other defects in construction.
2.3 GLASS PRODUCTS, GENERAL
A. Glazing Publications: Comply with published recommendations of glass product manufacturers
and organization below unless more stringent requirements are indicated. Refer to these
publications for glazing terms not otherwise defined in this Section or in referenced standards.
1. GANA Publications: "Laminated Glazing Reference Manual" and "Glazing Manual."
B. Safety Glazing Labeling: Permanently mark glazing with certification label of the Safety
Glazing Certification Council or another certification agency acceptable to authorities having
jurisdiction or the manufacturer. Label shall indicate manufacturer's name, type of glass, glass
thickness, and safety glazing standard with which glass complies.
2.4 GLASS PRODUCTS
A. Float Glass: ASTM C 1036, Type I, Quality-Q3, Class I (clear) unless otherwise indicated.
B. Tempered Float Glass: ASTM C 1048, Kind FT (fully tempered), Condition A (uncoated)
unless otherwise indicated, Type I, Class I (clear) unless otherwise indicated, Quality-Q3.
1. Fabrication Process: By horizontal (roller-hearth) process with roll-wave distortion
parallel to bottom edge of glass as installed unless otherwise indicated.
C. Laminated Glass: ASTM C 1172. Use materials that have a proven record of no tendency to
bubble, discolor, or lose physical and mechanical properties after fabrication and installation.
1. Construction: Laminate glass with polyvinyl butyral interlayer unless fire-protection or
fire-resistance rating is based on another product.
2. Interlayer Thickness: Provide thickness as needed to comply with requirements.
3. Interlayer Color: Clear unless otherwise indicated.
2.5 FIRE-PROTECTION-RATED GLAZING
A. Fire-Protection-Rated Glazing: Listed and labeled by a testing agency acceptable to authorities
having jurisdiction, for fire-protection ratings indicated, based on positive-pressure testing
according to NFPA 257 or UL 9, including the hose-stream test, and shall comply with NFPA
80.
1. Fire-protection-rated glazing required to have a fire-protection rating of 20 minutes shall
be exempt from the hose-stream test.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 4
B. Fire-Protection-Rated Glazing Labeling: Permanently mark fire-protection-rated glazing with
certification label of a testing agency acceptable to authorities having jurisdiction. Label shall
indicate manufacturer's name; test standard; whether glazing is permitted to be used in doors or
openings; if permitted in openings, whether or not glazing has passed the hose-stream test;
whether or not glazing meets 450 deg F (250 deg C) temperature-rise limitation; and the
fire-resistance rating in minutes.
C. Fire-Protection-Rated Tempered Glass: 6-mm thickness, fire-protection-rated tempered glass;
and complying with 16 CFR 1201, Category II.
1.Products: Subject to compliance with requirements, provide one of the following:
a.InterEdge Technologies by AGC Flat Glass; PyroEdge-20.
b.Safti First Fire Rated Glazing Solutions; SuperLite I.
c.Technical Glass Products; Fireglass20.
d.Vetrotech Saint-Gobain; SSG Pyroswiss US.
D. Laminated Ceramic Glazing: Laminated glass made from two plies of clear, ceramic glass;
8-mm total thickness; and complying with 16 CFR 1201, Category II.
1.Products: Subject to compliance with requirements, provide one of the following:
a.Safti First Fire Rated Glazing Solutions; Pyran Platinum L
b.Schott North America, Inc.; Pyran Platinum L.
c.Technical Glass Products; FireLite Plus.
d.Vetrotech Saint-Gobain; SGG Keralite FR-L.
2.6 GLAZING ACCESSORIES
A. Provide glazing gaskets, glazing sealants, glazing tapes, setting blocks, spacers, edge blocks,
and other glazing accessories that are compatible with glazing products and each other and are
approved by testing agencies that listed and labeled fire-resistant glazing products with which
products are used for applications and fire-protection ratings indicated.
B. Glazing Sealants for Fire-Rated Glazing Products: Neutral-curing silicone glazing sealant
complying with ASTM C 920, Type S, Grade NS, Class 50, Use NT. Comply with sealant and
glass manufacturers' written instructions for selecting glazing sealants suitable for applications
indicated.
1.Products: Subject to compliance with requirements, provide one of the following:
a.Dow Corning Corporation; 795.
b.GE Construction Sealants; Momentive Performance Materials Inc; SilGlaze II
SCS2800.
c.Tremco Incorporated; Spectrem 2.
2. Sealants shall have a VOC content of 250 g/L or less.
3. Colors of Exposed Glazing Sealants: As selected by Architect from manufacturer's full
range.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 5
C. Back-Bedding Mastic Glazing Tapes: Preformed, butyl-based, 100 percent solids elastomeric
tape; nonstaining and nonmigrating in contact with nonporous surfaces; with or without spacer
rod as recommended in writing by tape and glass manufacturers for application indicated; and
complying with ASTM C 1281 and AAMA 800 for products indicated below:
1. AAMA 806.3 tape, for glazing applications in which tape is subject to continuous
pressure.
2. AAMA 807.3 tape, for glazing applications in which tape is not subject to continuous
pressure.
D. Expanded Cellular Glazing Tapes: Closed-cell, PVC foam tapes; factory coated with adhesive
on both surfaces; and complying with AAMA 800 for the following types:
1. AAMA 810.1, Type 1, for glazing applications in which tape acts as the primary sealant.
2. AAMA 810.1, Type 2, for glazing applications in which tape is used in combination with
a full bead of liquid sealant.
2.7 MISCELLANEOUS GLAZING MATERIALS
A. General: Provide products of material, size, and shape complying with referenced glazing
standard, requirements of manufacturers of glass and other glazing materials for application
indicated, and with a proven record of compatibility with surfaces contacted in installation.
B. Cylindrical Glazing Sealant Backing: ASTM C 1330, Type O (open-cell material), of size and
density to control glazing sealant depth and otherwise produce optimum glazing sealant
performance.
C. Perimeter Insulation for Fire-Resistive Glazing: Product that is approved by testing agency that
listed and labeled fire-resistant glazing product with which it is used for application and
fire-protection rating indicated.
2.8 FABRICATION OF GLAZING UNITS
A. Fabricate glazing units in sizes required to fit openings indicated for Project, with edge and face
clearances, edge and surface conditions, and bite complying with written instructions of product
manufacturer and referenced glazing publications, to comply with system performance
requirements.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine framing, glazing channels, and stops, with Installer present, for compliance with
manufacturing and installation tolerances, including those for size, squareness, and offsets at
corners, and for compliance with minimum required face and edge clearances.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 6
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Clean glazing channels and other framing members receiving glass immediately before glazing.
Remove coatings not firmly bonded to substrates.
B. Examine glazing units to locate fire side and protected side. Label or mark units as needed so
that fire side and protected side are readily identifiable. Do not use materials that leave visible
marks in the completed work.
3.3 GLAZING, GENERAL
A. Use methods approved by testing agencies that listed and labeled fire-resistant glazing
products.
B. Comply with combined written instructions of manufacturers of glass, sealants, gaskets, and
other glazing materials unless more stringent requirements are indicated, including those in
referenced glazing publications.
C. Protect glass edges from damage during handling and installation. Remove damaged glass from
Project site and legally dispose of off Project site. Damaged glass is glass with edge damage or
other imperfections that, when installed, could weaken glass and impair performance and
appearance.
D. Apply primers to joint surfaces where required for adhesion of sealants, as determined by
preconstruction testing.
E. Install setting blocks in sill rabbets, sized and located to comply with referenced glazing
publications unless otherwise required by glass manufacturer. Set blocks in thin course of
compatible sealant suitable for heel bead.
F. Do not exceed edge pressures stipulated by glass manufacturers for installing glass lites.
G. Provide spacers for glass lites where length plus width is larger than 50 inches.
1. Locate spacers directly opposite each other on both inside and outside faces of glass.
Install correct size and spacing to preserve required face clearances unless gaskets and
glazing tapes are used that have demonstrated ability to maintain required face clearances
and to comply with system performance requirements.
2. Provide 1/8-inch minimum bite of spacers on glass and use thickness equal to sealant
width. With glazing tape, use thickness slightly less than final compressed thickness of
tape.
H. Provide edge blocking where indicated or needed to prevent glass lites from moving sideways
in glazing channel, as recommended in writing by glass manufacturer and according to
requirements in referenced glazing publications.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 7
I. Set glass lites with proper orientation so that coatings face fire side or protected side as
specified.
J. Where wedge-shaped gaskets are driven into one side of channel to pressurize sealant or gasket
on opposite side, provide adequate anchorage so gasket cannot walk out when installation is
subjected to movement.
K. Square cut wedge-shaped gaskets at corners and install gaskets in a manner recommended by
gasket manufacturer to prevent corners from pulling away; seal corner joints and butt joints
with sealant recommended by gasket manufacturer.
3.4 TAPE GLAZING
A. Position tapes on fixed stops so that, when compressed by glass, their exposed edges are flush
with or protrude slightly above sightline of stops.
B. Install tapes continuously, but not necessarily in one continuous length. Do not stretch tapes to
make them fit opening.
C. Cover vertical framing joints by applying tapes to heads and sills first and then to jambs. Cover
horizontal framing joints by applying tapes to jambs and then to heads and sills.
D. Place joints in tapes at corners of opening with adjoining lengths butted together, not lapped.
Seal joints in tapes with compatible sealant approved by tape manufacturer.
E. Do not remove release paper from tape until right before each glazing unit is installed.
F. Center glass lites in openings on setting blocks and press firmly against tape by inserting dense
compression gaskets formed and installed to lock in place against faces of removable stops.
Start gasket applications at corners and work toward centers of openings.
3.5 GASKET GLAZING (DRY)
A. Cut compression gaskets to lengths recommended by gasket manufacturer to fit openings
exactly, with allowance for stretch during installation.
B. Insert soft compression gasket between glass and frame or fixed stop, so it is securely in place
with joints miter cut and bonded together at corners.
C. Installation with Drive-in Wedge Gaskets: Center glass lites in openings on setting blocks and
press firmly against soft compression gasket by inserting dense compression gaskets formed
and installed to lock in place against faces of removable stops. Start gasket applications at
corners and work toward centers of openings.
D. Install gaskets so they protrude past face of glazing stops.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
FIRE-RESISTANT GLAZING 088813 - 8
3.6 SEALANT GLAZING (WET)
A. Install continuous spacers, or spacers combined with cylindrical sealant backing, between glass
lites and glazing stops to maintain glass face clearances. Secure spacers or spacers and backings
in place and in position to control depth of installed sealant relative to edge clearance for
optimum sealant performance.
3.7 CLEANING AND PROTECTION
A. Protect glass from contact with contaminating substances resulting from construction
operations. Examine glass surfaces adjacent to or below exterior concrete and other masonry
surfaces at frequent intervals during construction, but not less than once a month, for buildup of
dirt, scum, alkaline deposits, or stains.
1. If, despite such protection, contaminating substances do come into contact with glass,
remove substances immediately as recommended in writing by glass manufacturer.
B. Remove and replace glass that is damaged during construction period.
C. Wash glass on both exposed surfaces in each area of Project not more than four days before
date scheduled for inspections that establish date of Substantial Completion. Wash glass as
recommended in writing by glass manufacturer.
END OF SECTION 088813
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
NON-STRUCTURAL METAL FRAMING 092216 - 1
SECTION 092216 - NON-STRUCTURAL METAL FRAMING
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Non-load-bearing steel framing systems for interior partitions.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Fire-Test-Response Characteristics: For fire-resistance-rated assemblies that incorporate
non-load-bearing steel framing, provide materials and construction identical to those tested in
assembly indicated, according to ASTM E 119 by an independent testing agency.
B. STC-Rated Assemblies: For STC-rated assemblies, provide materials and construction identical
to those tested in assembly indicated, according to ASTM E 90 and classified according to
ASTM E 413 by an independent testing agency.
C. Horizontal Deflection: For wall assemblies, limited to 1/360 of the wall height based on
horizontal loading of 10 lbf/sq. ft. .
2.2 FRAMING SYSTEMS
A. Manufacturers: Subject to compliance with requirements; provide products by one or more of
the following:
1. Clark Dietrich Building Systems.
2. Fire Trak Corp.
3. Marino/Ware Division of Ware Industries.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
NON-STRUCTURAL METAL FRAMING 092216 - 2
4. Metal-Lite.
5. SCAFCO Corporation.
6. Steel Network, Inc. (The)
7. Studco Building Systems.
8. Telling Industries.
B. Recycled Content of Steel Products: Postconsumer recycled content plus one-half of
preconsumer recycled content not less than 25 percent.
C. Framing Members, General: Comply with ASTM C 754 for conditions indicated.
1. Steel Sheet Components: Comply with ASTM C 645 requirements for metal unless
otherwise indicated.
2. Protective Coating: ASTM A 653/A 653M, G40 , hot-dip galvanized unless otherwise
indicated.
D. Studs and Runners: ASTM C 645. Use either steel studs and runners or embossed steel studs
and runners.
1. Steel Studs and Runners:
a. Minimum Base-Metal Thickness: 0.0296 inch, 20-gauge equivalent, non-structural.
For framed openings more than 40 inches wide, increase metal thickness to
16-gage equivalent.
b. Depth: As indicated on Drawings.
2. Embossed Steel Studs and Runners:
a. Minimum Base-Metal Thickness: 0.0190 inch to 0.0209 inch, 20-gauge
equivalent, non-structural, depending on the depth of stud. For framed openings
more than 40 inches wide, increase metal thickness to 16-gage equivalent.
b. Depth: As indicated on Drawings.
E. Slip-Type Head Joints: Where indicated, provide one of the following:
1. Single Long-Leg Runner System: ASTM C 645 top runner with 2-inchdeep flanges in
thickness not less than indicated for studs, installed with studs friction fit into top runner
and with continuous bridging located within 12 inchesof the top of studs to provide
lateral bracing.
2. Double-Runner System: ASTM C 645 top runners, inside runner with 2-inch deep
flanges in thickness not less than indicated for studs and fastened to studs, and outer
runner sized to friction fit inside runner.
3. Deflection Track: Steel sheet top runner manufactured to prevent cracking of finishes
applied to interior partition framing resulting from deflection of structure above; in
thickness not less than indicated for studs and in width to accommodate depth of studs.
F. Firestop Tracks: Top runner manufactured to allow partition heads to expand and contract with
movement of structure while maintaining continuity of fire-resistance-rated assembly indicated;
in thickness not less than indicated for studs and in width to accommodate depth of studs.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
NON-STRUCTURAL METAL FRAMING 092216 - 3
G. Flat Strap and Backing Plate: Steel sheet for blocking and bracing in length and width
indicated.
1. Minimum Base-Metal Thickness: 0.0296 inch, 20-gauge equivalent, non-structural.
H. Cold-Rolled Channel Bridging: Steel, 0.0538-inch, 16-gauge equivalent minimum base-metal
thickness, with minimum 1/2-inchwide flanges.
1. Depth: Not less than 1-1/2 inches.
2. Clip Angle: Not less than 1-1/2 by 1-1/2 inches, 0.068-inchthick, galvanized steel.
2.3 AUXILIARY MATERIALS
A. General: Provide auxiliary materials that comply with referenced installation standards.
1. Fasteners for Metal Framing: Of type, material, size, corrosion resistance, holding power,
and other properties required to fasten steel members to substrates.
B. Isolation Strip at Exterior Walls: Provide one of the following:
1. Asphalt-Saturated Organic Felt: ASTM D 226/D 226M, Type I (No. 15 asphalt felt),
nonperforated.
2. Foam Gasket: Adhesive-backed, closed-cell vinyl foam strips that allow fastener
penetration without foam displacement, 1/8 inchthick, in width to suit steel stud size.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine areas and substrates, with Installer present, and including welded hollow-metal
frames, cast-in anchors, and structural framing, for compliance with requirements and other
conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Suspended Assemblies: Coordinate installation of suspension systems with installation of
overhead structure to ensure that inserts and other provisions for anchorages to building
structure have been installed to receive hangers at spacing required to support the Work and
that hangers will develop their full strength.
1. Furnish concrete inserts and other devices indicated to other trades for installation in
advance of time needed for coordination and construction.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
NON-STRUCTURAL METAL FRAMING 092216 - 4
3.3 INSTALLATION, GENERAL
A. Installation Standard: ASTM C 754.
1. Gypsum Board Assemblies: Also comply with requirements in ASTM C 840 that apply
to framing installation.
B. Install framing and accessories plumb, square, and true to line, with connections securely
fastened.
C. Install bracing at terminations in assemblies.
D. Do not bridge building control and expansion joints with non-load-bearing steel framing
members. Frame both sides of joints independently.
3.4 INSTALLING FRAMED ASSEMBLIES
A. Install framing system components according to spacings indicated, but not greater than
spacings required by referenced installation standards for assembly types.
1. Single-Layer Application: 16 inches o.c. unless otherwise indicated.
B. Where studs are installed directly against exterior masonry walls or dissimilar metals at exterior
walls, install isolation strip between studs and exterior wall.
C. Install studs so flanges within framing system point in same direction.
D. Install tracks (runners) at floors and overhead supports. Extend framing full height to structural
supports or substrates above suspended ceilings except where partitions are indicated to
terminate at suspended ceilings. Continue framing around ducts that penetrate partitions above
ceiling.
1. Slip-Type Head Joints: Where framing extends to overhead structural supports, install to
produce joints at tops of framing systems that prevent axial loading of finished
assemblies.
2. Door Openings: Screw vertical studs at jambs to jamb anchor clips on door frames; install
runner track section (for cripple studs) at head and secure to jamb studs.
a. Install two studs at each jamb unless otherwise indicated.
1) For framed openings more than 40 inches wide, increase metal thickness to
16-gage equivalent.
b. Install cripple studs at head adjacent to each jamb stud, with a minimum
1/2-inchclearance from jamb stud to allow for installation of control joint in
finished assembly.
3. Other Framed Openings: Frame openings other than door openings the same as required
for door openings unless otherwise indicated. Install framing below sills of openings to
match framing required above door heads.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
NON-STRUCTURAL METAL FRAMING 092216 - 5
4. Fire-Resistance-Rated Partitions: Install framing to comply with fire-resistance-rated
assembly indicated and support closures and to make partitions continuous from floor to
underside of solid structure.
a. Firestop Track: Where indicated, install to maintain continuity of
fire-resistance-rated assembly indicated.
5. Sound-Rated Partitions: Install framing to comply with sound-rated assembly indicated.
E. Installation Tolerance: Install each framing member so fastening surfaces vary not more than
1/8 inchfrom the plane formed by faces of adjacent framing.
END OF SECTION 092216
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
GYPSUM BOARD 092900 - 1
SECTION 092900 - GYPSUM BOARD
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Interior gypsum board.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
1.4 DELIVERY, STORAGE AND HANDLING
A. Store materials inside under cover and keep them dry and protected against weather,
condensation, direct sunlight, construction traffic, and other potential causes of damage. Stack
panels flat and supported on risers on a flat platform to prevent sagging.
1.5 FIELD CONDITIONS
A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board
manufacturer's written instructions, whichever are more stringent.
B. Do not install paper-faced gypsum panels until installation areas are enclosed and conditioned.
C. Do not install panels that are wet, moisture damaged, and mold damaged.
1. Indications that panels are wet or moisture damaged include, but are not limited to,
discoloration, sagging, or irregular shape.
2. Indications that panels are mold damaged include, but are not limited to, fuzzy or
splotchy surface contamination and discoloration.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
GYPSUM BOARD 092900 - 2
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. STC-Rated Assemblies: For STC-rated assemblies, provide materials and construction identical
to those tested in assembly indicated according to ASTM E90 and classified according to
ASTM E 413 by an independent testing agency.
2.2 GYPSUM BOARD, GENERAL
A. Size: Provide maximum lengths and widths available that will minimize joints in each area and
that correspond with support system indicated.
2.3 INTERIOR GYPSUM BOARD
A. Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
1.CertainTeed Corporation.
2.Georgia-Pacific Building Products.
3.National Gypsum Company.
4. United States Gypsum Company.
B. Gypsum Wallboard: ASTM C1396/C 1396M.
1. Thickness: 1/2 inch.
2. Long Edges: Tapered.
C. Gypsum Board, Type X: ASTM C1396/C 1396M.
1. Thickness: 5/8 inch15.9 mm.
2. Long Edges: Tapered.
2.4 TRIM ACCESSORIES
A. Interior Trim: ASTM C 1047.
1. Material: Galvanized or aluminum-coated steel sheet, rolled zinc, plastic, or paper-faced
galvanized-steel sheet.
2. Shapes:
a. Cornerbead.
2.5 JOINT TREATMENT MATERIALS
A. General: Comply with ASTM C 475/C 475M.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
GYPSUM BOARD 092900 - 3
B. Joint Tape:
1. Interior Gypsum Board: Paper.
C. Joint Compound for Interior Gypsum Board: For each coat, use formulation that is compatible
with other compounds applied on previous or for successive coats.
1. Prefilling: At open joints and damaged surface areas, use setting-type taping compound.
2. Embedding and First Coat: For embedding tape and first coat on joints, fasteners, and
trim flanges, use setting-type taping compound.
3. Fill Coat: For second coat, use drying-type, all-purpose compound.
4. Finish Coat: For third coat, use drying-type, all-purpose compound.
5. Skim Coat: For final coat of Level 5 finish, use drying-type, all-purpose compound or
high-build interior coating product designed for application by airless sprayer and to be
used instead of skim coat to produce Level 5 finish.
2.6 AUXILIARY MATERIALS
A. General: Provide auxiliary materials that comply with referenced installation standards and
manufacturer's written instructions.
B. Laminating Adhesive: Adhesive or joint compound recommended for directly adhering gypsum
panels to continuous substrate.
1. Adhesives shall have a VOC content of 50 g/L or less.
C. Steel Drill Screws: ASTM C1002 unless otherwise indicated.
1. Use screws complying with ASTM C 954 for fastening panels to steel members from
0.033 to 0.112 inch thick.
2. For fastening cementitious backer units, use screws of type and size recommended by
panel manufacturer.
D. Sound-Attenuation Blankets: ASTM C 665, Type I (blankets without membrane facing)
produced by combining thermosetting resins with mineral fibers manufactured from glass, slag
wool, or rock wool.
E. Acoustical Sealant: Manufacturer's standard nonsag, paintable, nonstaining latex sealant
complying with ASTM C 834. Product effectively reduces airborne sound transmission through
perimeter joints and openings in building construction as demonstrated by testing representative
assemblies according to ASTM E 90.
1. Sealant shall have a VOC content of 250 g/L or less.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
GYPSUM BOARD 092900 - 4
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine areas and substrates including welded hollow-metal frames and support framing, with
Installer present, for compliance with requirements and other conditions affecting performance
of the Work.
B. Examine panels before installation. Reject panels that are wet, moisture damaged, and mold
damaged.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 APPLYING AND FINISHING PANELS, GENERAL
A. Comply with ASTM C 840.
B. Install panels with face side out. Butt panels together for a light contact at edges and ends with
not more than 1/16 inch of open space between panels. Do not force into place.
C. Locate edge and end joints over supports, except in ceiling applications where intermediate
supports or gypsum board back-blocking is provided behind end joints. Do not place tapered
edges against cut edges or ends. Stagger vertical joints on opposite sides of partitions. Do not
make joints other than control joints at corners of framed openings.
D. Cover both faces of support framing with gypsum panels in concealed spaces (above ceilings,
etc.), except in chases braced internally.
1. Unless concealed application is indicated or required for sound, fire, air, or smoke
ratings, coverage may be accomplished with scraps of not less than 8 sq. ft. in area.
2. Fit gypsum panels around ducts, pipes, and conduits.
3. Where partitions intersect structural members projecting below underside of floor/roof
slabs and decks, cut gypsum panels to fit profile formed by structural members; allow
1/4- to 3/8-inch- wide joints to install sealant.
E. Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural
abutments. Provide 1/4- to 1/2-inch- wide spaces at these locations and trim edges with edge
trim where edges of panels are exposed. Seal joints between edges and abutting structural
surfaces with acoustical sealant.
F. STC-Rated Assemblies: Seal construction at perimeters, behind control joints, and at openings
and penetrations with a continuous bead of acoustical sealant. Install acoustical sealant at both
faces of partitions at perimeters and through penetrations. Comply with ASTM C 919 and with
manufacturer's written instructions for locating edge trim and closing off sound-flanking paths
around or through assemblies, including sealing partitions above acoustical ceilings.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
GYPSUM BOARD 092900 - 5
G. Install sound attenuation blankets before installing gypsum panels unless blankets are readily
installed after panels have been installed on one side.
3.3 APPLYING INTERIOR GYPSUM BOARD
A. Single-Layer Application:
1. On partitions/walls, apply gypsum panels vertically (parallel to framing) unless otherwise
indicated or required by fire-resistance-rated assembly, and minimize end joints.
a. Stagger abutting end joints not less than one framing member in alternate courses
of panels.
2. Fastening Methods: Apply gypsum panels to supports with steel drill screws.
B. Laminating to Substrate: Where gypsum panels are indicated as directly adhered to a substrate
(other than studs, joists, furring members, or base layer of gypsum board), comply with gypsum
board manufacturer's written instructions and temporarily brace or fasten gypsum panels until
fastening adhesive has set.
3.4 INSTALLING TRIM ACCESSORIES
A. General: For trim with back flanges intended for fasteners, attach to framing with same
fasteners used for panels. Otherwise, attach trim according to manufacturer's written
instructions.
B. Control Joints: Install control joints according to ASTM C840 and in specific locations
approved by Architect for visual effect.
C. Interior Trim: Install in the following locations:
1. Cornerbead: Use at outside corners.
3.5 FINISHING GYPSUM BOARD
A. General: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations,
fastener heads, surface defects, and elsewhere as required to prepare gypsum board surfaces for
decoration. Promptly remove residual joint compound from adjacent surfaces.
B. Prefill open joints and damaged surface areas.
C. Apply joint tape over gypsum board joints, except for trim products specifically indicated as
not intended to receive tape.
D. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to
ASTM C 840:
1. Level 1: Ceiling plenum areas, concealed areas, and where indicated.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
GYPSUM BOARD 092900 - 6
2. Level 2: Panels that are substrate for ceramic or acoustical tile.
3. Level 3: Not used.
4. Level 4: At panel surfaces that will be exposed to view unless otherwise indicated.
5. Level 5: Not used.
3.6 PROTECTION
A. Protect adjacent surfaces from drywall compound and promptly remove from floors and other
non-drywall surfaces. Repair surfaces stained, marred, or otherwise damaged during drywall
application.
B. Protect installed products from damage from weather, condensation, direct sunlight,
construction, and other causes during remainder of the construction period.
C. Remove and replace panels that are wet, moisture damaged, and mold damaged.
1. Indications that panels are wet or moisture damaged include, but are not limited to,
discoloration, sagging, or irregular shape.
2. Indications that panels are mold damaged include, but are not limited to, fuzzy or
splotchy surface contamination and discoloration.
END OF SECTION 092900
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT BASE AND ACCESSORIES 096513 - 1
SECTION 096513 - RESILIENT BASE AND ACCESSORIES
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Resilient base.
2. Resilient molding accessories.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Samples for Initial Selection: For each type of product indicated.
C. Samples for Verification: For each type of product indicated and for each color, texture, and
pattern required in manufacturer's standard-size samples, but not less than 12 inches long.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Store resilient products and installation materials in dry spaces protected from the weather, with
ambient temperatures maintained within range recommended by manufacturer, but not less than
50 deg F or more than 90 deg F.
1.5 FIELD CONDITIONS
A. Maintain ambient temperatures within range recommended by manufacturer, but not less than
70 deg F or more than 95 deg F, in spaces to receive resilient products during the following
time periods:
1. 48 hours before installation.
2. During installation.
3. 48 hours after installation.
B. After installation and until Substantial Completion, maintain ambient temperatures within range
recommended by manufacturer, but not less than 55 deg F or more than 95 deg F.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT BASE AND ACCESSORIES 096513 - 2
C. Install resilient products after other finishing operations, including painting, have been
completed.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. FloorScore Compliance: Resilient base and stair accessories shall comply with requirements
of FloorScore certification.
2.2 THERMOPLASTIC-RUBBER BASE
A. Products: Subject to compliance with requirements, provide products by one of the following:
1.Armstrong World Industries, Inc.
2.Johnsonite; A Tarkett Company; TRADITIONAL.
3. Mannington Commercial; PREMIUM EDGE.
4.Roppe Corporation, USA; 700 SERIES.
B. Product Standard: ASTM F 1861, Type TP (rubber, thermoplastic).
1. Group: I (solid, homogeneous).
2. Style and Location:
a. Style A, Straight: Provide in areas with carpet.
b. Style B, Cove: Provide in areas with resilient flooring.
C. Thickness: 0.125 inch.
D. Height: 4 inches.
E. Lengths: Cut lengths 48 inches long or coils in manufacturer's standard length.
F. Outside Corners: Preformed.
G. Inside Corners: Job formed or preformed.
H. Colors: Match existing.
2.3 VINYL MOLDING ACCESSORY
A. Description: Vinyl transition strips.
B. Profile and Dimensions: As indicated.
C. Locations: Provide vinyl molding accessories in areas indicated.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT BASE AND ACCESSORIES 096513 - 3
D. Colors and Patterns: As selected by Architect from full range of industry colors.
2.4 INSTALLATION MATERIALS
A. Trowelable Leveling and Patching Compounds: Latex-modified, portland cement based or
blended hydraulic-cement-based formulation provided or approved by resilient-product
manufacturer for applications indicated.
B. Adhesives: Water-resistant type recommended by resilient-product manufacturer for resilient
products and substrate conditions indicated.
1. Adhesives shall have a VOC content of 50 g/L or less except that adhesive for rubber
stair treads shall have a VOC content of 60 g/L or less.
C. Floor Polish: Provide protective, liquid floor-polish products recommended by resilient
stair-tread manufacturer.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, with Installer present, for compliance with requirements for maximum
moisture content and other conditions affecting performance of the Work.
1. Verify that finishes of substrates comply with tolerances and other requirements specified
in other Sections and that substrates are free of cracks, ridges, depressions, scale, and
foreign deposits that might interfere with adhesion of resilient products.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
1. Installation of resilient products indicates acceptance of surfaces and conditions.
3.2 PREPARATION
A. Prepare substrates according to manufacturer's written instructions to ensure adhesion of
resilient products.
B. Fill cracks, holes, and depressions in substrates with trowelable leveling and patching
compound; remove bumps and ridges to produce a uniform and smooth substrate.
C. Do not install resilient products until they are the same temperature as the space where they are
to be installed.
1. At least 48 hours in advance of installation, move resilient products and installation
materials into spaces where they will be installed.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT BASE AND ACCESSORIES 096513 - 4
D. Immediately before installation, sweep and vacuum clean substrates to be covered by resilient
products.
3.3 RESILIENT BASE INSTALLATION
A. Comply with manufacturer's written instructions for installing resilient base.
B. Apply resilient base to walls, columns, pilasters, casework and cabinets in toe spaces, and other
permanent fixtures in rooms and areas where base is required.
C. Install resilient base in lengths as long as practical without gaps at seams and with tops of
adjacent pieces aligned.
D. Tightly adhere resilient base to substrate throughout length of each piece, with base in
continuous contact with horizontal and vertical substrates.
E. Do not stretch resilient base during installation.
F. On masonry surfaces or other similar irregular substrates, fill voids along top edge of resilient
base with manufacturer's recommended adhesive filler material.
G. Preformed Corners: Install preformed corners before installing straight pieces.
H. Job-Formed Corners:
1. Inside Corners: Use straight pieces of maximum lengths possible and form with returns
not less than 4 inches in length.
a. Miter or cope corners to minimize open joints.
3.4 RESILIENT ACCESSORY INSTALLATION
A. Comply with manufacturer's written instructions for installing resilient accessories.
B. Resilient Molding Accessories: Butt to adjacent materials and tightly adhere to substrates
throughout length of each piece. Install reducer strips at edges of floor covering that would
otherwise be exposed.
3.5 CLEANING AND PROTECTION
A. Comply with manufacturer's written instructions for cleaning and protecting resilient products.
B. Perform the following operations immediately after completing resilient-product installation:
1. Remove adhesive and other blemishes from exposed surfaces.
2. Sweep and vacuum horizontal surfaces thoroughly.
3. Damp-mop horizontal surfaces to remove marks and soil.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT BASE AND ACCESSORIES 096513 - 5
C. Protect resilient products from mars, marks, indentations, and other damage from construction
operations and placement of equipment and fixtures during remainder of construction period.
D. Floor Polish: Remove soil, visible adhesive, and surface blemishes from resilient stair treads
before applying liquid floor polish.
1. Apply two coat(s).
E. Cover resilient products subject to wear and foot traffic until Substantial Completion.
END OF SECTION 096513
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT TILE FLOORING 096519 - 1
SECTION 096519 - RESILIENT TILE FLOORING
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Vinyl composition floor tile.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: For each type of floor tile. Include floor tile layouts, edges, columns,
doorways, enclosing partitions, built-in furniture, cabinets, and cutouts.
1. Show details of special patterns.
C. Samples for Verification: Full-size units of each color and pattern of floor tile required.
D. Product Schedule: For floor tile. Use same designations indicated on Drawings.
1.4 CLOSEOUT SUBMITTALS
A. Maintenance Data: For each type of floor tile to include in maintenance manuals.
1.5 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials that match products installed and that are packaged with protective
covering for storage and identified with labels describing contents.
1. Floor Tile: Furnish one box for every 50 boxes or fraction thereof, of each type, color,
and pattern of floor tile installed.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT TILE FLOORING 096519 - 2
1.6 QUALITY ASSURANCE
A. Installer Qualifications: A qualified installer who employs workers for this Project who are
competent in techniques required by manufacturer for floor tile installation and seaming
method indicated.
1. Engage an installer who employs workers for this Project who are trained or certified by
floor tile manufacturer for installation techniques required.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Store floor tile and installation materials in dry spaces protected from the weather, with ambient
temperatures maintained within range recommended by manufacturer, but not less than 50 deg
F or more than 90 deg F. Store floor tiles on flat surfaces.
1.8 FIELD CONDITIONS
A. Maintain ambient temperatures within range recommended by manufacturer, but not less than
70 deg F or more than 95 deg F, in spaces to receive floor tile during the following time
periods:
1. 48 hours before installation.
2. During installation.
3. 48 hours after installation.
B. After installation and until Substantial Completion, maintain ambient temperatures within range
recommended by manufacturer, but not less than 55 deg F or more than 95 deg F.
C. Close spaces to traffic during floor tile installation.
D. Close spaces to traffic for 48 hours after floor tile installation.
E. Install floor tile after other finishing operations, including painting, have been completed.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Fire-Test-Response Characteristics: For resilient tile flooring, as determined by testing
identical products according to ASTM E 648 or NFPA 253 by a qualified testing agency.
1. Critical Radiant Flux Classification: Class I, not less than 0.45 W/sq. cm.
B. FloorScore Compliance: Resilient tile flooring shall comply with requirements of FloorScore
certification.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT TILE FLOORING 096519 - 3
2.2 VINYL COMPOSITION FLOOR TILE
A.Products: Subject to compliance with requirements, available products that may be
incorporated into the Work include, but are not limited to, the following:
1.AB; American Biltrite.
2.Armstrong World Industries, Inc.
3. Johnsonite; a Tarkett Company.
B. Tile Standard: ASTM F 1066, Class 2, through-pattern.
C. Wearing Surface: Smooth.
D. Thickness: 0.125 inch.
E. Size: 12 by 12 inches.
F. Colors and Patterns: Match Architect's sample.
2.3 INSTALLATION MATERIALS
A. Trowelable Leveling and Patching Compounds: Latex-modified, portland cement based or
blended hydraulic-cement-based formulation provided or approved by floor tile manufacturer
for applications indicated.
B. Adhesives: Water-resistant type recommended by floor tile and adhesive manufacturers to suit
floor tile and substrate conditions indicated.
1. Adhesives shall comply with the following limits for VOC content:
a. Vinyl Composition Tile Adhesives: 50 g/L or less.
C. Floor Polish: Provide protective, liquid floor-polish products recommended by floor tile
manufacturer.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates, with Installer present, for compliance with requirements for maximum
moisture content and other conditions affecting performance of the Work.
1. Verify that finishes of substrates comply with tolerances and other requirements specified
in other Sections and that substrates are free of cracks, ridges, depressions, scale, and
foreign deposits that might interfere with adhesion of floor tile.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT TILE FLOORING 096519 - 4
3.2 PREPARATION
A. Prepare substrates according to floor tile manufacturer's written instructions to ensure adhesion
of resilient products.
B. Concrete Substrates: Prepare according to ASTM F 710.
1. Verify that substrates are dry and free of curing compounds, sealers, and hardeners.
2. Remove substrate coatings and other substances that are incompatible with adhesives and
that contain soap, wax, oil, or silicone, using mechanical methods recommended by floor
tile manufacturer. Do not use solvents.
3. Alkalinity and Adhesion Testing: Perform tests recommended by floor tile manufacturer.
Proceed with installation only after substrate alkalinity falls within range on pH scale
recommended by manufacturer in writing, but not less than 5 or more than 9 pH.
4. Moisture Testing: Proceed with installation only after substrates pass testing according
to floor tile manufacturer's written recommendations, but not less stringent than the
following:
a. Perform relative humidity test using in situ probes according to ASTM F 2170.
Proceed with installation only after substrates have a maximum 75 percent relative
humidity level.
C. Fill cracks, holes, and depressions in substrates with trowelable leveling and patching
compound; remove bumps and ridges to produce a uniform and smooth substrate.
D. Do not install floor tiles until they are the same temperature as the space where they are to be
installed.
1. At least 48 hours in advance of installation, move resilient floor tile and installation
materials into spaces where they will be installed.
E. Immediately before installation, sweep and vacuum clean substrates to be covered by resilient
floor tile.
3.3 FLOOR TILE INSTALLATION
A. Comply with manufacturer's written instructions for installing floor tile.
B. Lay out floor tiles from center marks established with principal walls, discounting minor
offsets, so tiles at opposite edges of room are of equal width. Adjust as necessary to avoid
using cut widths that equal less than one-half tile at perimeter.
1. Lay tiles in pattern indicated.
C. Match floor tiles for color and pattern by selecting tiles from cartons in the same sequence as
manufactured and packaged, if so numbered. Discard broken, cracked, chipped, or deformed
tiles.
1. Lay tiles in pattern of colors and sizes indicated.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
RESILIENT TILE FLOORING 096519 - 5
D. Scribe, cut, and fit floor tiles to butt neatly and tightly to vertical surfaces and permanent
fixtures including built-in furniture, cabinets, pipes, outlets, and door frames.
E. Extend floor tiles into toe spaces, door reveals, closets, and similar openings. Extend floor
tiles to center of door openings.
F. Maintain reference markers, holes, and openings that are in place or marked for future cutting
by repeating on floor tiles as marked on substrates. Use chalk or other nonpermanent marking
device.
G. Adhere floor tiles to flooring substrates using a full spread of adhesive applied to substrate to
produce a completed installation without open cracks, voids, raising and puckering at joints,
telegraphing of adhesive spreader marks, and other surface imperfections.
3.4 CLEANING AND PROTECTION
A. Comply with manufacturer's written instructions for cleaning and protecting floor tile.
B. Perform the following operations immediately after completing floor tile installation:
1. Remove adhesive and other blemishes from exposed surfaces.
2. Sweep and vacuum surfaces thoroughly.
3. Damp-mop surfaces to remove marks and soil.
C. Protect floor tile from mars, marks, indentations, and other damage from construction
operations and placement of equipment and fixtures during remainder of construction period.
D. Floor Polish: Remove soil, adhesive, and blemishes from floor tile surfaces before applying
liquid floor polish.
1. Apply two coat(s).
E. Cover floor tile until Substantial Completion.
END OF SECTION 096519
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
INTERIOR PAINTING 099123 - 1
SECTION 099123 - INTERIOR PAINTING
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes surface preparation and the application of paint systems on interior substrates.
1.3 DEFINITIONS
A. MPI Gloss Level 1: Not more than five units at 60 degrees and 10 units at 85 degrees,
according to ASTM D 523.
B. MPI Gloss Level 3: 10 to 25 units at 60 degrees and 10 to 35 units at 85 degrees, according to
ASTM D 523.
C. MPI Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D 523.
D. MPI Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D 523.
1.4 ACTION SUBMITTALS
A. Product Data: For each type of product. Include preparation requirements and application
instructions.
1. Include Printout of current "MPI Approved Products List" for each product category
specified, with the proposed product highlighted.
2. Indicate VOC content.
B. Samples for Verification: For each type of paint system and in each color and gloss of topcoat.
1. Submit Samples on rigid backing, 8 inches square.
2. Apply coats on Samples in steps to show each coat required for system.
3. Label each coat of each Sample.
4. Label each Sample for location and application area.
C. Product List: Cross-reference to paint system and locations of application areas. Use same
designations indicated on Drawings and in schedules. Include color designations.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
INTERIOR PAINTING 099123 - 2
1.5 DELIVERY, STORAGE, AND HANDLING
A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient
temperatures continuously maintained at not less than 45 deg F.
1. Maintain containers in clean condition, free of foreign materials and residue.
2. Remove rags and waste from storage areas daily.
1.6 FIELD CONDITIONS
A. Apply paints only when temperature of surfaces to be painted and ambient air temperatures are
between 50 and 95 deg F.
B. Do not apply paints when relative humidity exceeds 85 percent; at temperatures less than 5
deg F above the dew point; or to damp or wet surfaces.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
1.Benjamin Moore & Co.
2.PPG Architectural Finishes, Inc.
3.Pratt & Lambert.
4.Sherwin-Williams Company (The).
B. Products: Subject to compliance with requirements, provide products listed in the Interior
Painting Schedule for each paint category indicated in Part 3 below.
2.2 PAINT, GENERAL
A. MPI Standards: Products shall comply with MPI standards indicated and shall be listed in its
"MPI Approved Products Lists."
B. Material Compatibility:
1. Materials for use within each paint system shall be compatible with one another and
substrates indicated, under conditions of service and application as demonstrated by
manufacturer, based on testing and field experience.
2. For each coat in a paint system, products shall be recommended in writing by topcoat
manufacturers for use in paint system and on substrate indicated.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
INTERIOR PAINTING 099123 - 3
C. VOC Content: For field applications that are inside the weatherproofing system, paints and
coatings shall comply with VOC content limits of authorities having jurisdiction and the
following VOC content limits:
1. Flat Paints and Coatings: 50 g/L.
2. Nonflat Paints and Coatings: 50 g/L.
3. Primers, Sealers, and Undercoaters: 100 g/L.
4. Zinc-Rich Industrial Maintenance Primers: 100 g/L.
D. Colors: As scheduled in the Drawings.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions, with Applicator present, for compliance with requirements
for maximum moisture content and other conditions affecting performance of the Work.
B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter
as follows:
1. Concrete: 12 percent.
2. Masonry (Clay and CMUs): 12 percent.
3. Wood: 15 percent.
4. Gypsum Board: 12 percent.
5. Plaster: 12 percent.
C. Gypsum Board Substrates: Verify that finishing compound is sanded smooth.
D. Verify suitability of substrates, including surface conditions and compatibility, with existing
finishes and primers.
E. Proceed with coating application only after unsatisfactory conditions have been corrected.
1. Application of coating indicates acceptance of surfaces and conditions.
3.2 PREPARATION
A. Comply with manufacturer's written instructions and recommendations in "MPI Architectural
Painting Specification Manual" applicable to substrates and paint systems indicated.
B. Remove hardware, covers, plates, and similar items already in place that are removable and are
not to be painted. If removal is impractical or impossible because of size or weight of item,
provide surface-applied protection before surface preparation and painting.
1. After completing painting operations, use workers skilled in the trades involved to
reinstall items that were removed. Remove surface-applied protection if any.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
INTERIOR PAINTING 099123 - 4
C. Clean substrates of substances that could impair bond of paints, including dust, dirt, oil, grease,
and incompatible paints and encapsulants.
1. Remove incompatible primers and reprime substrate with compatible primers or apply tie
coat as required to produce paint systems indicated.
D. Masonry Substrates: Remove efflorescence and chalk. Do not paint surfaces if moisture content
or alkalinity of surfaces or mortar joints exceeds that permitted in manufacturer's written
instructions.
E. Steel Substrates: Remove rust, loose mill scale, and shop primer, if any. Clean using methods
recommended in writing by paint manufacturer.
F. Shop-Primed Steel Substrates: Clean field welds, bolted connections, and areas where shop
paint is abraded. Paint exposed areas with the same material as used for shop priming to
comply with SSPC-PA 1 for touching up shop-primed surfaces.
G. Wood Substrates:
1. Scrape and clean knots, and apply coat of knot sealer before applying primer.
2. Sand surfaces that will be exposed to view, and dust off.
3. Prime edges, ends, faces, undersides, and backsides of wood.
4. After priming, fill holes and imperfections in the finish surfaces with putty or plastic
wood filler. Sand smooth when dried.
H. Cotton or Canvas Insulation Covering Substrates: Remove dust, dirt, and other foreign material
that might impair bond of paints to substrates.
3.3 APPLICATION
A. Apply paints according to manufacturer's written instructions and to recommendations in "MPI
Manual."
1. Use applicators and techniques suited for paint and substrate indicated.
2. Paint surfaces behind movable equipment and furniture same as similar exposed surfaces.
Before final installation, paint surfaces behind permanently fixed equipment or furniture
with prime coat only.
3. Paint front and backsides of access panels, removable or hinged covers, and similar
hinged items to match exposed surfaces.
4. Do not paint over labels of independent testing agencies or equipment name,
identification, performance rating, or nomenclature plates.
5. Primers specified in painting schedules may be omitted on items that are factory primed
or factory finished if acceptable to topcoat manufacturers.
B. Tint each undercoat a lighter shade to facilitate identification of each coat if multiple coats of
same material are to be applied. Tint undercoats to match color of topcoat, but provide
sufficient difference in shade of undercoats to distinguish each separate coat.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
INTERIOR PAINTING 099123 - 5
C. If undercoats or other conditions show through topcoat, apply additional coats until cured film
has a uniform paint finish, color, and appearance.
D. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks,
roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color
breaks.
E. Painting Fire Suppression, Plumbing, HVAC, Electrical, Communication, and Electronic Safety
and Security Work:
1. Paint the following work where exposed in occupied spaces:
a. Equipment, including panelboards.
b. Uninsulated metal piping.
c. Uninsulated plastic piping.
d. Pipe hangers and supports.
e. Metal conduit.
f. Plastic conduit.
g. Duct, equipment, and pipe insulation having cotton or canvas insulation covering
or other paintable jacket material.
h. Other items as directed by Architect.
2. Paint portions of internal surfaces of metal ducts, without liner, behind air inlets and
outlets that are visible from occupied spaces.
3.4 CLEANING AND PROTECTION
A. At end of each workday, remove rubbish, empty cans, rags, and other discarded materials from
Project site.
B. After completing paint application, clean spattered surfaces. Remove spattered paints by
washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces.
C. Protect work of other trades against damage from paint application. Correct damage to work of
other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and
leave in an undamaged condition.
D. At completion of construction activities of other trades, touch up and restore damaged or
defaced painted surfaces.
3.5 INTERIOR PAINTING SCHEDULE
A. CMU Substrates:
1. Institutional Low-Odor/VOC Latex System MPI INT 4.2E:
a. Block Filler: Block filler, latex, interior/exterior.
b. Intermediate Coat: Latex, interior, institutional low odor/VOC, matching topcoat.
Cornell University
DELTA TAU DELTA CODE REMEDIATION
104 Mary Ann Wood Drive
Ithaca, NY 14850
HOLT Project No. 2018029
INTERIOR PAINTING 099123 - 6
c. Topcoat: Latex, interior, institutional low odor/VOC, semi-gloss (MPI Gloss
Level 5).
B. Steel Substrates:
1. Water-Based Light Industrial Coating System, MPI INT 5.1B:
a. Application: Hollow metal door frames.
b. Prime Coat: Primer, rust-inhibitive, water based, MPI #107.
c. Intermediate Coat: Light industrial coating, interior, water based, matching topcoat.
d. Topcoat: Light industrial coating, interior, water based, semi-gloss (MPI Gloss
Level 5), MPI #153.
C. Galvanized-Metal Substrates:
1. Institutional Low-Odor/VOC Latex System MPI INT 5.3N:
a. Prime Coat: Primer, galvanized, water based, MPI #134.
b. Intermediate Coat: Latex, interior, institutional low odor/VOC, matching topcoat.
c. Topcoat: Latex, interior, institutional low odor/VOC, semi-gloss (MPI Gloss
Level 5), MPI #147.
D. Wood Substrates: Wood trim and wood board paneling.
1. Institutional Low-Odor/VOC Latex System MPI INT 6.3V:
a. Prime Coat: Primer, latex, for interior wood, MPI #39.
b. Intermediate Coat: Latex, interior, institutional low odor/VOC, matching topcoat.
c. Topcoat: Latex, interior, institutional low odor/VOC, semi-gloss (MPI Gloss
Level 5), MPI #147.
E. Gypsum Board Substrates:
1. Institutional Low-Odor/VOC Latex System MPI INT 9.2M:
a. Prime Coat: Primer sealer, interior, institutional low odor/VOC, MPI #149.
b. Intermediate Coat: Latex, interior, institutional low odor/VOC, matching topcoat.
c. Topcoat: Latex, interior, institutional low odor/VOC, flat (MPI Gloss
Level 1), MPI #143.
d. Topcoat: Latex, interior, institutional low odor/VOC (MPI Gloss
Level 3), MPI #145.
END OF SECTION 099123