HomeMy WebLinkAboutDRAWINGS - Cornell - Carpenter Hall Renovations - MEP (2)MVAVMN.O.N.C.C.N.C.FC.N.O.PPTPDNSDFSDTORX"xX"DSFDHVAC LEGENDSDESCRIPTIONABBREVIATIONABBREVIATIONDESCRIPTIONDESCRIPTIONABBREVIATIONABBREVIATIONDESCRIPTIONAADAUTOMATIC DAMPERACUAIR CONDITIONING UNITADACCESS DOORAFFABOVE FINISH FLOORAHUAIR HANDLING UNITAPDAIR PRESSURE DROP IN. WGATUAIR TERMINAL UNITAWTAVERAGE WATER TEMPERATUREBASBUILDING AUTOMATION SYSTEMBDDBACK DRAFT DAMPERBFSBOILER FEED STATIONBHPBRAKE HORSEPOWERBTUBRITISH THERMAL UNITBTUHBRITISH THERMAL UNITS PER HOURCFMCUBIC FEET PER MINUTECUCONDENSING UNITCUHCABINET UNIT HEATERDDIFFUSERdbDRY BULB (°F)DDCDIRECT DIGITAL CONTROLDHWDOMESTIC HOT WATERDIA,øDIAMETERDNDOWNDWGDRAWINGDXDIRECT EXPANSION(E)EXISTINGEAEXHAUST AIREATENTERING AIR TEMPERATURE (°F)ECELECTRICAL CONTRACTOREDBENTERING DRY BULBEFFEFFICIENCYESPEXTERNAL STATIC PRESSUREEWBENTERING WET BULB (°F)EWTENTERING WATER TEMPERATURE (°F)FFAN°FDEGREES FAHRENHEITFAFREE AREA (SQ. FT.)FCUFAN COIL UNITFDFIRE DAMPER (WITH ACCESS DOOR)FLAFULL LOAD AMPSFPIFINS PER INCHFPMFEET PER MINUTEFSDFIRE-SMOKE DAMPER (WITH ACCESS DOOR)FT or 'FEET (OF HEAD)FTRFIN TUBE RADIATIONGGRILLEGALGALLONSGCGENERAL CONSTRUCTION CONTRACTORGPHGALLONS PER HOURHPHORSEPOWERHWRHOT WATER RETURNHWSHOT WATER SUPPLYKWKILOWATTSLLOUVERLATLEAVING AIR TEMPERATURE (°F)LBSPOUNDSLDLOUVER/DAMPERLDBLEAVING DRY BULBLWBLEAVING WET BULBLWTLEAVING WATER TEMPERATURE (°F)MAXMAXIMUMMBHTHOUSAND BTUHMCMECHANICAL CONTRACTORMCAMINIMUM CIRCUIT AMPACITYMINMINIMUMNCNORMALLY CLOSEDNICNOT IN CONTRACTNONORMALLY OPENNTSNOT TO SCALEOAOUTDOOR AIRPCPLUMBING CONTRACTORPDPRESSURE DROPPRVPRESSURE REDUCING VALVEPSIPOUNDS PER SQUARE INCHUNIT HEATERVIBRATION ISOLATORPIPING SYMBOLDESCRIPTIONPIPING SYMBOL2-WAY CONTROL VALVEGLOBE VALVETRIPLE DUTY VALVEOPEN BUTTERFLY VALVEGATE VALVESOLENOID - ELECTRIC - ON/OFFDESCRIPTIONPIPING RISEUNION CONNECTIONBOTTOM PIPE CONNECTIONTOP PIPE CONNECTIONFLANGE CONNECTIONPIPING DROPPIPING SYMBOLPRESSURE REDUCING VALVECLOSED BUTTERFLY VALVESTRAINERBALANCE VALVEFUSIBLE LINK VALVECIRCULATING PUMPPRESSURE GAUGEPRESSURE SENSORAQUASTATDESCRIPTIONMISC. SYMBOLSDIAL THERMOMETERPRESSURE SWITCHPIPE ANCHORPIPE GUIDEPREMANUFACTURED EXPANSION LOOPFLEXIBLE CONNECTORDIRECTION OF FLUID FLOWPITCH PIPING DOWNPIPE CAP/ PLUGPIPING REDUCER - CONCENTRICPIPING REDUCER - ECCENTRICVACUUM BREAKERMISC. SYMBOLSTHERMOSTATNEW TO EXISTING CONNECTIONTHERMOMETERCEILING GRILLE (G)CEILING DIFFUSER (D)REGISTER (R)LINEAR DIFFUSER (D)DESCRIPTIONDOOR LOUVER OR UNDERCUTFIN TUBE RADIATION WITH ENCLOSUREFIN TUBE RADIATION BARE ELEMENTPRESSURE/TEMP PLUGMANUAL AIR VENTFLOW METERTEMPERATURE WELLBACKFLOW PREVENTERSTEAM TRAPAUTOMATIC AIR VENT3-WAY CONTROL VALVE(MIXING APPLICATION)(DIVERTING APPLICATION)3-WAY CONTROL VALVERELIEF VALVECHECK VALVEBALL VALVE - CLOSEDBALL VALVE - OPENFLOW SWITCHDESCRIPTIONAIR FLOWWALL REGISTER OR GRILLE -ROOF EXHAUST FANNON-POWERED ROOF VENTILATORDUCT SYMBOLCAPPED DUCTDESCRIPTIONDUCT TRANSITION FROMRECTANGULAR TO ROUNDFIRE/SMOKE DAMPERSMOKE DAMPERRECTANGULAR TODUCT TRANSITION FROMRECTANGULARSQUARE TO ROUND BRANCH DUCTRADIUS ELBOW (MIN R/W = 1.5)ELBOW WITH TURNING VANESMAKE UP WATERPUMPED DISCHARGEREFRIGERANT LIQUIDGLYCOL WATER SUPPLYGLYCOL WATER RETURNREFRIGERANT SUCTIONMUPDRLGWSGWRRSDESCRIPTIONDUCT SYMBOLDUCT - DOWN - NEGATIVE PRESSUREDUCT - UP - NEGATIVE PRESSUREDUCT - DOWN - POSITIVE PRESSUREDUCT SIZE - FIRST FIGURE IS SIZEDUCT - UP - POSITIVE PRESSUREDUCT - UP THRU ROOF - POSITIVE PRESSUREDUCT - UP THRU ROOF - NEGATIVE PRESSURESHOWNFLEXIBLE CONNECTIONACOUSTICALLY LINED DUCTWORKFLEXIBLE DUCTFIRE DAMPERVOLUME DAMPERDUCT SMOKE DETECTORPIPING SYMBOLSATVCDBBDATMOSPHERIC VENTBOILER BLOW DOWNCONDENSATE DRAINDESCRIPTIONCHILLED WATER SUPPLYCHILLED WATER RETURNCHWSCHWRGHWSHWRNATURAL GASHOT WATER SUPPLYHOT WATER RETURNCAST IRON RADIATIONCIRGPMGALLONS PER MINUTERVROOF VENTSLSKYLIGHTUHUNIT HEATERRTUROOF TOP UNITMAUMAKE UP AIR UNITUVUNIT VENTILATORVVENTRARETURN AIR / RELIEF AIREFEXHAUST FANMAMIXED AIRSCCVSELF CONTAINED CONTROL VALVETEMPERATURE SENSORM Binary InputBinary OutputAnalog Input Analog OutputTTWater Temperature SensorWater Flow MeterMotorCurrent TransducerOutside Air Temperature Sensor withSun ShieldAir Temperature SensorNormally OpenNormally ClosedFreezstatSupply AirReturn AirExhaust AirOutside AirAirflow SensorMotorized DamperSmoke DetectorDifferential Pressure SensorVariable Frequency DriveTwo-Way Control ValveZone SensorCirculating PumpCONTROL LEGENDBIBOAIAOMCTN.O.N.C.SARAEAOAMTTHLVFDTTCarbon Dioxide SensorCO2MThree-Way Control ValveEnd SwitchEXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019HVAC GENERAL NOTES ANDLEGENDSM0.01Project Number: 18.007No. Description Date
DNLKJH764.5354GFEDD.5C.7EXSTAHU14" CHWS14" CHWR14" CHWR14" CHWS10"ø10"ø10"ø10"ø3/4" COND1 1/4" SAN2" CHWR2" CHWS1 1/2" HWR4" SAN3" DCW4" SAN1" DCW3/4" DCW4" SAN1 1/2" HWS1" DCW3/4" DCW3" HWS3/4" DCW3/4" DCW1" HWS1" HWS1" HWS1" HWS1" HWS1" HWS1" HWS1" HWS1" HWS1" HWS1" HWS3" HWS3" HWS3" HWS3" HWS1/2" DCW3" HWS3" HWS4" HWR4" HWR1 1/4" HWS1 1/4" HWR2" HWR2" HWS1 1/2" HWR6" CHWS6" CHWR1" CHWR1" CHWS2" CHWR2" CHWS10"ø1 1/4" HWR1 1/4" HWS1 1/2" HWR1 1/2" HWS2" HWS2" HWR1" DCW1 1/2" HWR2" CHWS2" CHWR3/4" CONDEXSTAHUEXISTINGCOIL TYP (5)EXSTCW PUMPEXSTSEWAGE EJECTOREXISTINGHW HX AND PUMP SET3/4" BURIED PIPE TO TRAILERSVALVED OFF (NOT USED). REMOVE BACK TO MAIN AND CAP. CAP AT WALL PENETRATION.REMOVE DUCT AND CAP AT AHUREMOVE 2" SANITARY BACK TO SEWAGE EJECTOR IN MECHANICAL ROOMREMOVE 4" SANITARY TO CLEANOUT AND CAPEXISTING 4" FOOTER DRAIN TO REMAINREMOVE 4" FOOTER DRAIN TO ACCOMODATE NEW STAIR2" HWS3/4" DCWSystems EngineeringLabB05StorageB05AEXISTING 4" FOOTER DRAIN TO REMAINMechanical RoomB06Transformer VaultB04EXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019B05 HVAC DEMOLITION PLANM1.01Project Number: 18.007 1/4" = 1'-0"1B05 HVAC DEMOLITION PLANPLANNORTHNo. Description Date
DN. ...LKJH764.5354GFEDD.57.5C.7EXSTAHUCAPCAPx32"42"18"ø10"ø10"ø12"øP-1CONNECT HWS/R TO EXISTING 4" HWS/R PROVIDE PUMP AND CONTROL VALVEP-2CONNECT CWS/R TO EXISTING CWS/R LOW POINT DRAINS. PROVIDE NEW LOW POINT DRAINS. PROVIDE PUMP AND CONTROL VALVE.PROVIDE BTU METER MONITORED THROUGH BAS. SEE DETAIL SHEET FOR ADDITIONAL INFORMATION.F-1AHU-136x30x72" EXHAUST PLENUM, ACOUSTICALLY LINED36"x18"36"x18"18"x12"16"ø1 1/2" HWS1 1/2" HWR14"øL-136"x18"PROVIDE FLOOR DRAIN. CONNECT TO NEW DRAIN PIPINGPROVIDE DUST COLLECTION HOOD FOR MITER SAW. PROVIDE DUST COLLECTOR IN MECHANICAL ROOM WITH 5" DUCTED CONNECTION TO HOOD.10" LASER CUTTER EXHAUST DUCTF-2Meeting Room 05B05GLoungeB05FMeeting Room 04B05EMeeting Room 03B05DMeeting Room 02B05CMeeting Room 01B05BMech WorkshopB05HSystems EngineeringLabB05Meeting Room 06B05JR-A420 CFMTYP.5M3.013M3.014" FOOTER DRAIN (E)EXISTING 4" FOOTER DRAINL-2NEW 4" FOOTER DRAIN ROUTE AROUND NEW STAIR2M3.011M3.01R-B 170 CFMR-B 170 CFMPROVIDE VD (TYP)12"x6"14"ø8"øG-A 340 CFMG-A 240 CFMG-A 220 CFMG-A 220 CFMG-A 300 CFMPROVIDE VD (TYP)R-B150 CFMR-B150 CFMPROVIDE VD (TYP)R-B180 CFMR-B180 CFMR-B180 CFMR-C220 CFMR-C220 CFMR-C240 CFM36"x18"36"x18"1 1/2" HWS1 1/2" HWR2 1/2" CHWS2 1/2" CHWR2 1/2" CHWR2 1/2" CHWS4M3.01EXHAUST PLENUM, ACOUSTICALLY LINEDG-B550 CFMACOUSTICALLY LINE ALL RETURN DUCTWORK IN MEETING ROOM 01, 02, 03, & 04.ACOUSTICALLY LINE ALL SUPPLY BRANCH DUCTWORK SERVING MEETING ROOM 01, 02, 03, & 04.10"ø24"x6"12"x6"12"x6"24"x6"10"ø24"x6"14"ø12"x6"12"x6"12"x6"CONTROL DAMPERCONTROL DAMPERR-C INSTALLED IN CEILING OF B05H400 CFMG-A INSTALLED IN CEILING OF B05H400 CFMD-A 320 CFM16"øG-C850 CFM PROVIDE VD (TYP)TS(AHU-1)CAP EXISTING FITTINGR-A 50 CFMR-A 50 CFMR-A 50 CFM6M3.01VD (TYP)BACKDRAFT DAMPERTSTSTSTSTSTSBALANCE VALVE, BALANCE FLOW IN CROSSOVER LOOP UNTIL HWS TO AHU IS 130 DEG FDN TO LASER CUTTERPROVIDE WYE FITTING AND 2- 4" DUCTED CONNECTIONSCONNECT NEW FLOOR DRAIN PIPING FROM STAIR TO EXISTING DRAIN LINE UNDER THE SLAB. SAW CUT FLOOR TO MAKE CONNECTION. PROVIDE CLEANOUT AND PATCH THE FLOOR TO MATCH THE EXISTINGNEW 4" FLOOR DRAIN PIPINGTransformer VaultB04Mechanical RoomB06StorageB05AR-A420 CFMR-A420 CFMR-A420 CFMR-A420 CFMR-A420 CFMR-A420 CFMR-A420 CFMG-C850 CFM PROVIDE VD (TYP)G-C850 CFM PROVIDE VD (TYP)GENERAL NOTE:COORDINATE SUSPENSION ATTACHMENT POINTS WITH ACOUSTICAL PANEL LAYOUT.14"ø12"ø10"øTYP. 8EXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019B05 HVAC RENOVATION PLANM2.01Project Number: 18.007 1/4" = 1'-0"1B05 HVAC RENOVATION PLANPLANNORTHNo. Description Date
Floor - Level 010"Floor - Level 00-13' - 0"AHU-1CWS/R (E)EXHAUST DUCT DOWN TO LASER CUTTER PROVIDE TRANSITION AND OFFSET TO AVOID EXISTING ELECTRICAL AND PIPING INFRASTRUCTURE SystemsEngineering LabB05Mech WorkshopB05HPROVIDE 1" NEOPRENE PAD BETWEEN UNIT BASE RAIL AND SUPPORT STEEL10' - 5 +/-KJHFloor - Level 010' - 0"KJH3M3.01KJHL-1L-2AREAWAY DRAINSTAIR DRAINCONNECT TO NEW DRAIN PIPINGFloor - Level 010"Floor - Level 00-13' - 0"764.53764.53547EXHAUST PLENUMR-BR-BR-CR-CR-CMeeting Room 04B05EMeeting Room 03B05DMeeting Room 02B05CMeeting Room 01B05B16"øEXISTING 4" FOOTER DRAINFloor - Level 010"Floor - Level 00-13' - 0"SystemsEngineering LabB0514"ø18"x36"18"x36"36"x18"-28"x18"10' - 5 +/-8' - 10" +/-10' - 0" +/-Floor - Level 010"Floor - Level 00-13' - 0"4.5Floor - Level 010' - 0"4.54ROUTE DUCT OVER CWS/R PIPINGSystemsEngineering LabB0511' - 0 +/-CWS/R PIPING (E)Floor - Level 010"Floor - Level 00-13' - 0"HHH18"x36"18"x36"EXISTING CONDUITSystemsEngineering LabB058' - 7" +/-EXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019HVAC SECTIONSM3.01Project Number: 18.007 1/4" = 1'-0"1Section Trough Workshop/AHU Elevation 1/4" = 1'-0"5Exterior Wall Elevation 1/4" = 1'-0"3Sidewall DRG Elevation 1/4" = 1'-0"2Duct Offset to Clear Existing Electric Devices 1/4" = 1'-0"4Duct Offset at CWS/R 1/4" = 1'-0"6OA Plenum ConnectionNo. Description Date
WHERE REQ'D. AN ADDITIONAL PUMP SUPPORT BRACKET MAY BE PROVIDED . PUMP SUPPORTS MUST BE INSTALLED IN SUCH A WAY AS TO NOT CREATE ANY STRESSES ON PUMP COMPONENTS. PUMP SUPPORTS SHALL NOT BE SO RIGIDLYMOUNTED THAT IT LIMITS THE PUMPS ABILITY TO MOVE WITH PIPE EXPANSION MOVEMENT.VERTICAL INLINE PUMPTYPICAL PIPE HANGER. REFER TO SPECIFICATIONS FOR TYPE AND SPACINGDRAW THROUGH UNITCOOLING COILMIN. FAN STATIC PRESSURE PLUS 1"MIN. 1/2 FAN STATIC PRESSURE PLUS 1"MIN. 1" WATER SEAL3/8" DIA. THREADED STEEL RODS,SUPPORT FROM BUILDING STRUCTURE, LENGTH OF RODS TO SUIT SPACE AVAILABLE.ADJUSTABLE MOTOR MOUNTMOUNTING BRACKETAIR FLOWFLEX CONNECTION (TYP.)CONNECT DUCTWORK TO FAN WITH 1/8"THICK NEOPRENE GASKET.STEEL SPRING AND RUBBER IN SHEAR TYPE VIBRATIONISOLATORS.DUCT SIZE AS SHOWN ON PLANMOUNTING BRACKET14"4 1/2"6"8"HOOD DETAILNOT TO SCALECLAMP, TYP. 2X30° MAX.5" INSIDE DIA.FLEXIBLE HOSE.5 DUCT.6" FLANGEON EACH SIDE.14"4 1/2"SECTION A-AA30"2" INSIDE DIAM.FLEXIBLE HOSEA45°SIDE VIEWEQUIPMENT BY OTHERSCLAMP, TYP. 2XBLAST GATE,SET @500 CFM4" DUCT. ATTACH TOEXISTING TABLEUSING MOUNTINGANGLESBLAST GATE,SET @ 430 CFMPRESSURE GAUGEw/GAUGE COCK (TYP.)MANUAL AIR VENT DRAINVALVECONTROL VALVECHWSCHWRCOILTHERMOMETER (TYP)1/2" GAUGE MANIFOLDDRAINPAN & TRAPPT PORT (TYP)PRESSURE GAUGEw/GAUGE COCK (TYP.)MANUAL AIR VENT DRAINVALVECONTROL VALVEHWSHWRCOILTHERMOMETER (TYP)1/2" GAUGE MANIFOLDPT PORT (TYP)PRESSURE GAUGEw/GAUGE COCK (TYP.)MANUAL AIR VENT PUMPPRIMARY CHWRTHERMOMETER (TYP)1/2" GAUGE MANIFOLDPT PORT (TYP)PRIMARY CHWSFLOW METERETHERNET/BAS MONITORINGSERIAL TO ETHERNET CONNECTIONTEMP SENSORTEMP SENSOR3/4" BALL VALVE DRAIN/VENT PROVIDE WITH BRASS HOSE CONNECTION AND CAP WITH CHAIN (TYP)BASKET STRAINERTEMPERATURE SENSOR TO BAS (TYP)TO AHU COILSEE DETAILFROM AHU COILBALANCE VALVECHECK VALVEPRESSURE GAUGEw/GAUGE COCK (TYP.)MANUAL AIR VENT PUMPPRIMARY HWRTHERMOMETER (TYP)1/2" GAUGE MANIFOLDPT PORT (TYP)PRIMARY HWS3/4" BALL VALVE DRAIN/VENT PROVIDE WITH BRASS HOSE CONNECTION AND CAP WITH CHAIN (TYP)BASKET STRAINERTEMPERATURE SENSOR TO BAS (TYP)TO AHU COILSEE DETAILFROM AHU COILBALANCE VALVECHECK VALVEEXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019HVAC DETAILSM3.02Project Number: 18.007SCALE - NONE1INLINE PUMP SUPPORT DETAILSCALE - NONE2A/C CONDENSATE DETAILSCALE - NONE5INLINE FAN DETAILSCALE - NONE6MITER BOX DETAILSCALE - NONE3CW COIL PIPING DETAILSCALE - NONE4HW COIL PIPING DETAILSCALE - NONE7CHILLED WATER SCHEMATIC/DETAILSCALE - NONE8HOT WATER WATER SCHEMATIC/DETAILREFER TO SCHEMATICS ON THIS PAGE FOR VALVES AND INSTRUMENTATION No. Description Date
LOUVER - LOUVER/DAMPER SCHEDULEUNIT NO.CFMNOTESDESIGN BASISLOCATIONSYSTEM SERVEDSERVICEDIMENSIONShieght"width"L-16000B 05AHU-1INTAKE48321, 2ELF375DFLL-25500B 05F-1/F-2EXHAUST42321, 3ELF375DFLNOTES: 1. COORDINATE ROUGH OPENING SIZE AND LOCATION WITH EXISTING FOUNDATION WALL DEMOLITION. 2. PROVIDE FRAME WITH FLANGE AT EXTERIOR FACE. 3. PROVIDE FRAME WITHOUT FLANGE AT EXTERIOR FACE.UNITDIFFUSER, REGISTERS & GRILLE SCHEDULESERVICEMAX. NCFACESIZE(INCH)DESIGN BASISNOTESMAX. S.P.(IN W.G.)ARRANGEMENTMAX. CFMNECKSIZE(INCH)R-ASUPPLY19-3/4 x 13-3/418x12600180.05SIDEWALL/DUCTTITUS 300 RL-R-BSUPPLY21-3/4 x 7-3/420x6240220.05SIDEWALL/DUCT/VAVTITUS T3SW1G-ARETURN25-3/4 x 7-3/424x6500180.05SIDEWALL/DUCTTITUS 350 RL-R-CSUPPLY25-3/4 x 7-3/424x6500220.05SIDEWALL/DUCT/VAVTITUS T3SW1G-BEXHAUST73-3/4 x 25-3/472x245500180.05SIDEWALL/DUCTTITUS 350 RL-D-ASUPPLY2712400180.05DUCTTITUS TMRA-G-CRETURN25-3/4 x 13-3/424x12900180.05SIDEWALL/DUCTTITUS 350 RL-NOTES: 1. PROVIDE VAV DIFFUSER WITH ALL REQUIRED POWER TRANSFORMERS, POWER MODULES, AND BACNET MS/TP MASTER COMMUNICATION MODULES. M.C. IS RESPONSIBLE FOR ALL POWER AND CONTROL WIRING ASSOCIATED WITH THE VAV DIFFUSER CONTROLS.AIR HANDLING UNIT SCHEDULEUNIT NO.MIN. O.A. C.F.M.NOTESDESIGN BASISSUPPLY FANVOLT/PHASEH.P.FAN R.P.M.T.S.P.LOCATIONARRANGEMENTPHYSICAL PROPERTIESLENGTH"WIDTH"HEIGHT"SUPPLY AIR C.F.M.COOLING/HEATINGWEIGHT LBS.UNIT MOPUNIT FLAMOUNTINGHOT WATER COILMBHGPMEWT/LWTTOTALMAT/LATCHILLED WATER COILMBHGPMEWT/LWTTOTAL/SENSIBLELDB/LWBFT-H20WPDFT-H20WPDAHU-1B 0561001810305.620130/9946/93252.4/154.61.3350.347/5953.8/53.7208/37.518003.635.028.1INDOOR143PLATFORM66.5452109TRANE CSAA012-6.66NOTES: 1. UNIT CONTROLLED BY VFD. ROWS4RPMPUMP SCHEDULEHPGPMSYSTEM SERVEDFT. OF HEADCAPACITYUNIT NO.MOTOR DATADESIGN BASISNOTESLOCATIONVOLTS/PHASEUNIT MCAUNIT MOPCONN. POINTSELECTRICALARRANGEMENTP-2P-1MECHANICAL ROOMHOT WATER COIL20INLINE201/63476208/12.91BELL & GOSSETT ECOCIRC XL 36-45NOTES: 1. PUMP SHALL BE PROVIDED WITH ECM MOTOR AND BACNET CONTROL INTERFACE1CHILLED WATER COIL50INLINE2012149208/111MECHANICAL ROOMBELL & GOSSETT ECOCIRC XL 65-1301510.420VOLTS/PHASEEXHAUST FAN SCHEDULEUNIT NO.AREA SERVEDHPTYPEDESIGN BASISDRIVENOTESLOCATIONCONN. POINTSELECTRICAL(in)LENGTHROOF OPG.ROOF OPG.WIDTH(in)PHYSICAL PROPERTIESLENGTH"WIDTH"HEIGHT"SONESFAN SPEEDTOTALC.F.M.RPMS.P.PERFORMANCEWEIGHT LBS.F-1B 05B 05208/33/4113.512260.35500INLINEBELTN/A3738.1338.13241GREENHECK BSQ-240-7-F-2LASER CUTTERB 05120/11/4113.417090.75650INLINEDIRECT21151548-GREENHECK SQ-99-VGN/AN/AN/ANOTES: 1. FAN CONTROLLED BY VFD. 2. FAN CONTROLLED BY MANUAL SWITCH.EXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019HVAC SCHEDULESM4.01Project Number: 18.007No. Description Date
SABI - Supply Air Smoke DetectorCHWSCHWRCHWAI - Return Air Carbon Dioxide PPMCO2BI - Return Air Smoke DetectorHLAI - Filter Differential PressureMMAO - Return Air DamperN.O.N.C.AI - Heat Air TempTBI - FreezestatTTAI - Return Air TempAI - Return AirflowAI - Supply AirflowHWSHWRHWAHU A. Run Conditions - Requested: The unit shall run whenever:•The zone is occupied.B. Emergency Shutdown: The unit shall shut down and generate an alarm upon receiving an emergency shutdown signal.C. Freeze Protection: The unit shall shut down and generate an alarm upon receiving a freezestat status.D. High Static Shutdown: The unit shall shut down and generate an alarm upon receiving a high static shutdown signal.E. Return Air Smoke Detection: The unit shall shut down and generate an alarm upon receiving a return air smoke detector status.F. Supply Air Smoke Detection: The unit shall shut down and generate an alarm upon receiving a supply air smoke detector status.G. AHU Optimal Start: The unit shall start prior to scheduled occupancy based on the time necessary for the zone to reach it'soccupied setpoints. The start time shall automatically adjust based on changes in outside air temperature and zone temperatures.H. Supply Fan: The supply fan shall run anytime the unit is commanded to run, unless shutdown on safeties. To prevent shortcycling, the supply fan shall have a user definable (adj.) minimum runtime. 1. Alarms shall be provided as follows:•Supply Fan Failure: Commanded on, but the status is off.•Supply Fan in Hand: Commanded off, but the status is on.I. Hot Water Coil Valve: The controller shall measure the mixed air temperature and modulate the heating coil valve tomaintain its setpoint 5°F (adj.) less than the supply air temperature setpoint. 1. The heating shall be enabled whenever:•Outside air temperature is less than 60°F (adj.).•AND the economizer is disabled.•AND the supply fan status is on. 2. The heating coil valve shall open for freeze protection whenever:•Mixed air temperature drops from 40°F to 35°F (adj.).•OR the freezestat is on.K. Supply Air Temperature Setpoint - Optimized: The controller shall monitor the supply air temperature and shall maintain asupply air temperature setpoint reset based on zone cooling and heating requirements. 1. The supply air temperature setpoint shall be reset for cooling based on zone cooling requirements as follows:•The initial supply air temperature setpoint shall be 55°F (adj.).•As cooling demand increases, the setpoint shall incrementally reset down to a minimum of 53°F (adj.).•As cooling demand decreases, the setpoint shall incrementally reset up to a maximum of 72°F (adj.) .L. Cooling Coil Valve: The controller shall measure the supply air temperature and modulate the cooling coil valve to maintain its cooling setpoint. 1. The cooling shall be enabled whenever:•Outside air temperature is greater than 60°F (adj.).•AND the economizer (if present) is disabled or fully open.•AND the supply fan status is on.•AND the heating is not active. 2. The cooling coil valve shall open to 100% (adj.) whenever the freezestat is on.M. Alarms shall be provided as follows:•High Supply Air Temp: If the supply air temperature is 5°F (adj.) greater than setpoint.•Low Supply Air Temperature Alarm: The controller shall alarm if the supply air temperature is less than 45°F (adj.).N. Economizer Mode:The system shall be equipped with differential dry bulb integrated economizer control.When return air continues to rise above the cooling setpoint, the return air temperature is above the outdoor air temperature, and theoutdoor dew point temperature is below 60 deg. F, integrated economizer shall be initiated. Outside and relief air dampers shall open and the returns air damper shall be closed. The relief air fan (F-1), shall increase speed based on outdoor airflow measuring stationsignal The minimum outside air damper shall open. Chilled water control valve shall modulate as required to maintain the discharge air temperature setpoint.Low Limit Shutoff:Integrated economizer control shall be disabled, and modulated economizer mode shall be initiated when outside air temperaturefalls below 55 deg. F.High Limit Shutoff:Integrated economizer control shall be disabled when the outdoor air temperature exceeds the return air temperature. The outsideair and relief dampers shall index to minimum, the return air damper shall index to maximum position and cooling mode shall be initiated.O. Minimum Outside Air Ventilation - Carbon Dioxide (CO2) Control: 1. When in the occupied mode, the controller shall monitor zone CO2 levels served by this air handling unit. The controllershall take the highest zone CO2 level and modulate the outside air dampers open on rising CO2 concentrations,overriding normal damper operation to maintain a CO2 setpoint of 750 ppm (adj.). 2. Alarms shall be provided as follows:•High Zone Carbon Dioxide Concentration: If the highest zone CO2 concentration is greater than 1000 ppm (adj.).P. Prefilter Differential Pressure Monitor: The controller shall monitor the differential pressure across the prefilter. 1. Alarms shall be provided as follows:•Prefilter Change Required: Prefilter differential pressure exceeds a user definable limit (adj.).Q. Mixed Air Temperature: The controller shall monitor the mixed air temperature and use as required for economizer control orheating control. 1. Alarms shall be provided as follows:•High Mixed Air Temp: If the mixed air temperature is greater than 90°F (adj.).•Low Mixed Air Temp: If the mixed air temperature is less than 45°F (adj.).R. Return Air Carbon Dioxide (CO2) Concentration Monitoring: The controller shall measure the return air CO2 levels. 1. Alarms shall be provided as follows:•High Return Air Carbon Dioxide Concentration: If the return air CO2 concentration is greater than 1000ppm (adj.) when inthe unit is running.OARAAI - Supply Air TempSoaAI - OA Airflow Measuring Station 3. Outside Air Flow Measuring Station:•The air flow station shall monitor the amount of ventilation air and track it against the CO2 levels in the space.TAI - Mixed Air TempTAI - Chilled Water Return TempTAI - Chilled Water Supply TempTTAI - Hot Water Return TempAI - Hot Water Supply TempTMCTVFDBO - Supply Fan Start/StopBI - Supply Fan StatusAO - Supply Fan VFD SpeedBI - Supply Fan VFD FaultSFMAO - Cooling ValveMAO - Heating ValveS. Return Air Temperature: The controller shall monitor the return air temperature and use as required for setpoint control oreconomizer control. 1. Alarms shall be provided as follows:•High Return Air Temp: If the return air temperature is greater than 90°F (adj.).•Low Return Air Temp: If the return air temperature is less than 45°F (adj.).T. Supply Air Temperature: The controller shall monitor the supply air temperature. 1. Alarms shall be provided as follows:•High Supply Air Temp: If the supply air temperature is greater than 120°F (adj.).•Low Supply Air Temp: If the supply air temperature is less than 55°F (adj.).MN.C.AO - Outside Air DamperAO - Outside Air Damper 2 Position at LouverH LAI - Duct Pressure SensorThe fan VFD shall modulate speed based on duct mounted pressure sensor. The system shall utilize variable air volume diffusers to maintain temperatures in the meeting room areas. SAMN.C.AI - Variable Air Volume DiffusserTBASSAMN.C.AI - Variable Air Volume DiffusserTSAMN.C.AI - Variable Air Volume DiffusserTSAMN.C.AI - Variable Air Volume DiffusserTSEE PLAN FOR QTY. OF VAV DIFFUSERSEXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019HVAC CONTROLSM5.01Project Number: 18.007SCALE - NONE1AHU WITH HW AND CWNo. Description Date
StarterHWS/CWSHWS/CWSPCTBI -Pump StatusBO - Pump Start/StopPump Control (typical)A. Run Conditions - Each respective pump (HW and CHW) shall be energized upon a call for either heating or cooling.B. Upon a call for heating or cooling the respective control valve shall open and the pump shall be energized. When the load is satisfied the pump shall de-energize and the control valve shall close.C. Pump speed shall modulate to maintain differential pressure input setting. The pressure differential sensor shall be provided for both hot water and chilled water pumps.D. Pump status: The controller shall monitor the pump status. 1. Alarms shall be provided as follows:•Failure: Commanded on, but the status is off.•Pump in Hand: Commanded off, but the status is on.Hot Water & Chilled Water Temperature Monitoring:The following temperaturesshall be monitored:•Hot & Chilled water supply.•Hot & Chilled water return.Alarms shall be provided as follows:•High Hot Water Supply Temp: If the hot water supply temperature is greater than 200°F(adj.).Low Hot Water Supply Temp: If the hot water supply temperature is less than 100°F(adj.).H LAI - Differential Pressure SensorHWR/CWRHWR/CWRHWS/CWS PUMPSMCTBI - Fan StatusBO - Fan Start/StopEAExhaust Fan - Variable Speed ControlA. Run Conditions - Scheduled: The fan shall run according to a userdefinable schedule (occupied/unoccupied).B. Fan: The fan shall have a user definable (adj.) minimumruntime.C. ExhaustAir Damper: The exhaust air damper shall open anytime the fan is energized and shall close anytime the unit stops, unless Fan F-2 is energized.D. Fan speed shall be adjusted to maintain neutral pressure in the space.control signal for speed adjustment shall be provided from the outdoorair flow measuring station at AHU-1. E. DamperStatus:The fan shall be enabled after the damper status has proven.F. Fan Status: The controller shall monitor the fan status. 1. Alarms shall be provided as follows:•Fan Failure: Commanded on, but the status is off.•Fan in Hand: Commanded off, but the status is on.•Fan Runtime Exceeded: Fan status runtime exceeds a user definable limit (adj.).AI - Outdoor Air Flow Measuring StationMN.C.Fan Start/StopEAExhaust Fan - Manual Switch (Laser Cutter)A. Run Conditions - The fan shall be controlled by a manual switch.B. The fan shall be energized when the laser engraver is in use.C. ExhaustAir Damper: The exhaust air damper shall open anytime the Fan is energized and shall close anytime the unit stops, unless fan F-1, is energized. MANUAL SWITCHMBI - Exhaust Air Damper StatusN.C.SBO - Exhaust Air DamperEAExhaust Louver/DamperA. ExhaustAir Damper: The exhaust air damper shall open anytime Fan F-1, or F-2 in energized and shall close anytime the both fans are de-energized.The exhaust air damper shall close 30sec (adj.) after the fan stops. 1. Alarms shall be provided as follows:•Damper Failure: Commanded open, but the status is closed.•Damperin Hand: Commanded closed, but the status is open.EXCELSIROPETROSPAPATHOMOPO U L O S 089554L I C E N S E DPROFESSIONALENGINEERSTATEOFNEWYORK Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019HVAC CONTROLSM5.02Project Number: 18.007SCALE - NONE1PUMP CONTROLSSCALE - NONE2EXHAUST FAN ON/OFF VFD CONTROLSSCALE - NONE3EXHAUST FAN ON/OFF MANUAL SWITCHSCALE - NONE4EXHAUST LOUVER/DAMPER CONTROLNo. Description Date
BUILDING CODEAPPLICABLE CODES2016 NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE ("UNIFORM CODE") WHICH AMENDS THE 2015 INTERNATIONAL BUILDING CODE (IBC) AND THE 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC)ELECTRICAL CODE2014 EDITION OF NFPA 70, NATIONAL ELECTRICAL CODEENERGY CODE2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) AS AMENDED BY THE UNIFORM CODEACCESSIBILITY2010 ADA STANDARDS FOR ACCESSIBLE DESIGNTHE FOLLOWING ARE THE CURRENTLY ADOPTED CODES AT THE TIME THESE CONTRACT DOCUMENTS WERE PREPARED:OTHERVARIOUS NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES AND STANDARDS AS REFERENCED BY THE CODES LISTED ABOVEFIRE ALARM2013 EDITION OF NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE1. THESE GENERAL ELECTRICAL NOTES SHALL APPLY TO ALL E SERIES DRAWINGS, IN COORDINATION WITH DIVISION 26, 27 & 28 SECTIONS, AND FRONT END (DIVISION 0 AND 1) REQUIREMENTS. ALL WORK ASSOCIATED WITH THE E SERIES DRAWINGS SHALL BE COORDINATED WITH ALL OTHER TRADES TO AVOID CONFLICTS. 2. ALL WORK SHALL BE PERFORMED IN COOPERATION WITH THE OWNER AND THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE CONSTRUCTION SCHEDULE ESTABLISHED BY THE OWNER, AND SHALL IMMEDIATELY REPORT ANY DELAYS IN MATERIALS RECEIPT INCLUDING CIRCUMSTANCES CAUSING DELAYS.• COMMENCE WORK AFTER PRECONSTRUCTION MEETING AND PROCEED DILIGENTLY AND CONTINUOUSLY TO COMPLETION.• PRIOR TO STARTING WORK, SUBMIT FOR OWNER'S APPROVAL, A DETAILED SCHEDULE INDICATING ALL WORK THAT MAY AFFECT THE BUILDING AND NEARBY BUILDINGS/STRUCTURES, SUCH AS UTILITY SHUT DOWNS, NOISE GENERATING EQUIPMENT, ETC.• PERFORM WORK IN A MANNER WHICH MINIMIZES NOISE. OPERATIONS IN WHICH NOISE CANNOT BE MINIMIZED SHALL BE SCHEDULED WITH OWNER.3. CONTRACT DRAWINGS FOR THE ELECTRICAL WORK ARE DIAGRAMMATIC, INTENDED TO CONVEY THE SCOPE OF WORK AND TO INDICATE THE GENERAL ARRANGEMENT AND APPROXIMATE LOCATION OF EQUIPMENT, PIPING, AND ACCESSORIES. THE INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING AND VERIFYING ALL CONDITIONS, DIMENSIONS, AND LOCATIONS PRIOR TO BIDDING PROJECT. CHECK PROJECT DRAWINGS PRIOR TO INSTALLATION FOR INTERFERENCES WITH OTHER TRADES. SHOULD THE CONTRACTOR FIND SUCH INTERFERENCES, THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING HIS WORK WITH OTHERS. THE OWNER RESERVES THE RIGHT TO MAKE REASONABLE CHANGES PRIOR TO ROUGH-IN WITHOUT ADDED EXPENSE. DIMENSIONS INDICATED ARE SUBJECT TO VERIFICATION OF EXACT SITE CONDITIONS AT THE TIME OF INSTALLATION.• THE CONTRACTOR SHALL INSTALL ALL CONDUIT, WIRE, EQUIPMENT, LIGHT FIXTURES, ETC. IN A WORKMAN LIKE MANNER WITH QUALIFIED ELECTRICIANS.• ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO THE OWNER.4. ALL ELECTRICAL WORK SHALL BE INSTALLED TO MEET THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, NEW YORK STATE BUILDING CODE, ENERGY CONSERVATION CODE, AND NYS FIRE CODE. ALL WORK SHALL COMPLY TO ACCORDANCE OF LOCAL, STATE AND FEDERAL REGULATIONS AND OTHER AUTHORITIES HAVING JURISDICTION. 5. CONTRACTOR RESPONSIBLE FOR PAYING FOR ALL FEES ASSOCIATED WITH OBTAINING INSPECTIONS. 6. THE ELECTRICAL CONTRACTOR SHALL BE LICENSED IN THE LOCAL JURISDICTION PRIOR TO BIDDING ON PROJECT. CONTRACTOR TO CONTACT CITY/TOWNSHIP TO VERIFY LICENSE TO ENSURE THEY ARE CURRENT.7. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER RECOMMENDATIONS. ANY CONFLICTS WITH INSTALLATION AND MANUFACTURER RECOMMENDATIONS SHALL BE REPORTED TO ENGINEER.8. CUTTING AND PATCHING - ALL NOTES BELOW HOLD THE COMMON CONDITION "UNLESS OTHERWISE NOTED". • NEW CONSTRUCTION:ALL CUTTING AND PATCHING THROUGH ALL WALL, CEILING, ETC. SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR IN COORDINATION WITH HIS WORK. ALL PAINTING AND FINISHING SHALL BE DONE BY GENERAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH GENERAL CONTRACTOR.• OPENINGS MADE POST-FINISH: IF AN OPENING IS REQUIRED IN A FINISHED SURFACE, AFTER COMPLETION, DUE TO LACK OF COORDINATION OR PROPER SCHEDULE MAINTENANCE, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CUTTING AND PATCHING REQUIRED TO FINISH SPECIFIC ELECTRICAL WORK AND RESTORE THE FINISHED SURFACE TO PREVIOUS CONDITION.9. PROVIDE (FURNISH AND INSTALL) ALL NEW EQUIPMENT AND MATERIALS AS DESCRIBED HEREIN. ANY MATERIAL, OPERATION, METHOD, OR DEVICE MENTIONED, LISTED OR NOTED WITHIN THIS SPECIFICATION SHALL BE FURNISHED BY THIS CONTRACTOR UNLESS SPECIFICALLY MENTIONED AS BEING FURNISHED OR INSTALLED BY OTHERS.• ALL MATERIALS SHALL BE AS SPECIFIED, OR EQUAL, AS APPROVED BY OWNER. MATERIALS SPECIFIED INDICATE QUALITY INTENT THAT WILL BE USED AS A BASIS FOR REVIEW OF SUBSTITUTES. SEE GENERAL CONDITIONS FOR SUBSTITUTION PROCEDURES.• MATERIALS SHALL BE STORED AT A LOCATION DETERMINED BY THE OWNER.• DELIVERY OF MATERIALS SHALL BE AS DIRECTED BY THE OWNER.10. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE COMPLETE AND OPERABLE SYSTEMS, INCLUDING OPERATIONAL PROPERTIES TO THE EXTEND NECESSARY TO LINK MULTIPLE COMPONENTS OF THE SYSTEMS TOGETHER AND TO INTERFACE WITH SYSTEMS PROVIDED BY OTHERS. THE ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL SYSTEMS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE.• THE CONTRACTOR SHALL PROVIDE OWNER WITH ALL NECESSARY OPERATION AND MAINTENANCE MANUALS, SHOP DRAWINGS, WIRING DIAGRAMS, AND WARRANTY PAPERWORK UPON COMPLETION OF THE PROJECT.• THE CONTRACTOR SHALL REPAIR, ADJUST, OR REPLACE ANY EQUIPMENT, MATERIAL, OR WORKMANSHIP FOUND TO BE DEFECTIVE.11. THE ELECTRICAL CONTRACTOR SHALL HOLD THE OWNER, ARCHITECT, AND ENGINEER HARMLESS AGAINST ANY AND ALL CLAIMS ARISING FROM WORK PERFORMED BY THIS CONTRACTOR ON THE SITE.12. DISCONNECTION OF SERVICES SHALL BE PERFORMED AT A TIME AUTHORIZED BY THE OWNER. TEMPORARY UTILITIES, IF NEEDED, WILL BE COORDINATED WITH THE OWNER.13. CONTRACTOR SHALL PROVIDE PROTECTION OF ADJACENT PROPERTY INCLUDE ALL EXISTING SITE AND LANDSCAPE ELEMENTS. FURTHERMORE, EVERY EFFORT SHALL BE MADE TO PROTECT BUILDING COMPONENTS DURING CONSTRUCTION. A PROTECTION PROPOSAL MUST BE SUBMITTED TO THE OWNER FOR REVIEW.14. CONTRACTOR SHALL KEEP SITE FREE OF DEBRIS AND ACCUMULATED REFUSE. SITE SHALL BE BROOM SWEPT AT THE END OF EACH WORKING DAY.15. ALL PENETRATIONS MADE IN EXISTING FIRE RATED WALLS, FLOORS, OR CEILINGS SHALL BE SEALED TO MAINTAIN THE FIRE RATING. REFER TO DIVISION 7 SPECIFICATIONS FOR ADDITIONAL INFORMATION.GENERAL NOTESFFVDUPLEX RECEPTACLEDUPLEX RECEPTACLE - ABOVE COUNTER, GFI# - WAY LIGHT SWITCHDIMMER SWITCHDMANUAL PULL STATIONAUDIO/VISUAL DEVICE (15CD UNLESS NOTED)VISUAL DEVICE ONLY (15CD UNLESS NOTED)LIGHT FIXTURE, REFER TO FIXTURE SCHEDULEXKEY NOTE, REFER TO KEY NOTES ON DRAWINGMANUAL MOTOR STARTERFUSED DISCONNECT (POLES, SIZE, FUSE) (3,30,20)JJUNCTION BOXLEGENDPCEILING MOTION SENSOR - PASSIVE INFRARED TECHNOLOGY (LINE VOLTAGE)EXIT SIGN - SINGLE SIDEDEXIT SIGN - TRIANGLES INDICATE DIRECTION ARROWSDDATA JACK - (2) DROPS UNLESS NOTEDWAPWIRELESS ACCESS POINTFBSURFACE MOUNTED MOTION SENSOR SWITCHMSFLOOR BOX##WBWALL BOXCRCARD READERDCDOOR CONTACT"WP"WEATHERPROOF#"ETR"EXISTING TO REINSTALLPLCEILING MOTION SENSOR - PASSIVE INFRARED TECHNOLOGY (LOW VOLTAGE)COMBINATION STARTER (POLES, NEMA SIZE, FUSE) (3,0,30)PCPHOTOCELL* DEMO PLANS USE SAME SYMBOLS ABOVE, EXCEPT DASHED LINETYPE.FLOOR18"TYPICAL DATA JACKTYPICALRECEPTACLE44"CEILINGLIGHT SWITCHFIRE ALARMPULL STATIONABOVE THE COUNTERRECEPTACLEF.A. A/VUNITS80" MIN. WHERE POSSIBLE42"108" (9') TOP OF FIXTURE FOR ALL SUSPENDED/ STEM MOUNT FIXTURES UNLESS OTHERWISE NOTEDABOVE THE COUNTERDATA JACKWAP BACKBOX (DEVICE BY OTHERS)90"CLEAR OF LIGHT FIXTURES, DUCTWORK, AND PIPESLIGHT FIXTUREVACANCY SENSORW/OWITHOUTUV UNIT VENTILATORTOILSYS SYSTEMUNDERGROUNDUGTOP AND BOTTOMTO BE DETERMINEDTEMPERATURETBTBDTCTEMPTOMTVTYPUEUHUNFUNOUTVVERTVIFTOILETTOP OF MASONRYTELEVISIONVERIFY IN FIELDVERTICALVOLTUNLESS NOTED OTHERWISEUNFINISHEDUNIT HEATERUNDERGROUND ELECTRICTYPICALUNDERGROUND TELEPHONEVOLUMEVOLTEL TELEPHONEW/WPWMWITHWATER PROOFINGWIREMOLDWINDOWWDWTIME CLOCK, TELECOMMUNICATIONS CONTRACTORREV REVISION, REVISEDROOMREVOLUTIONS PER MINUTEROOF TOP HOODROOF TOP UNITRMRPMRTHRTUSSCHEDSDSECSHTSLVSPKRSQSSSTDSTLSOUTHSCHEDULESMOKE DAMPERSECTIONSTEELSTANDARDSTAINLESS STEELSQUARESPRINKLERSLEEVESHEETSTORAGESTRUCTURALSURFACESUSPENDEDSUSPSURFSTRSTORSPECIFICATION (S)SPECRIGID GALVANIZED STEELRGSSQUARE FEETSFREFRIGERATORREFRPERIMETERPERIREINFREMREQDREQUIREDREMOVEREINFORCE (D) (ING)PAINTEDPRESSURE TREATED PRESERVATIVEPOLYVINYL CHLORIDEPAVEMENTROOFING CONTRACT (OR) RECEPTACLEPROJECTPREFORMEDPREPARE (ATION)POWER ROOF EXHAUSTERPAIRPOSITIVEPANELPLUGMOLDRECEPTRCPVMTPVCPTPPTDPROJPRFPREPPREPRPOSPNLPMPLYWDPLASPCPARTPPLYWOODPLASTER, PLASTICPLUMBING CONTRACT (OR)PARTITIONPAINTPTFR PRESSURE TREATED FIRE RETARDANTMOUNTMTLOUVERMANUALMATERIALMAKE UP AIR UNITMAXIMUMLVRMANMATMAUMAXMDMECHMEDMEMEZZMFRMHMINMISCMTDMTGMTLMTRNNATNCNECNEGNEUTNICNONTSMOTORIZED DAMPERMECHANICALMEDIUMMECHANICAL EQUIPMENTMEZZANINEMANUFACTURE (R)MAN HOLEMINIMUMNOT TO SCALENUMBER, NORMALLY OPENNOT IN CONTRACTNEUTRALNEGATIVENATIONAL ELECTRIC CODENORMALLY CLOSEDNATURALNORTHMETALMOUNTINGMOUNTEDMISCELLANEOUSMETEROVERALLON CENTEROUTSIDE DIAMETEROVERHEADOHODOCOALV LOW VOLTAGEJUNCTIONJCTHHEIGHTHEAVY DUTYHORIZONTALHORSEPOWERHANDRAIL, HOURHEIGHTHEATINGHEATINGHDHORZHPHRHTHTGHVACHVUHWHWHHWPHVIDININCLINTJCKWLLABLBLBLLCHEATING AND VENTILATING UNITHOT WATERHOT WATER HEATERHOT WATER PUMPHIGH VOLTAGEINSIDE DIAMETERINCHESINCLUDE (D) (ING)LANDSCAPE CONTRACTOR (SITE)LABELPOUNDLABORATORYLENGTH, LONGKILOWATTJANITORS CLOSETINTERIORLINEAR FOOTLFHDW HARDWAREJB JUNCTION BOXKV KILOVOLTKVA KILOVOLT AMPEREFEETFTF FAHRENHEITFA FIRE ALARMFIRE DEPARTMENT CONNECTIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFINISH FLOOR ELEVATIONFINISH FLOOR LINEFINISH (ED)FIXTUREFLUSHFDCFEFECFFEFFLFINFIXTFLFLEXFLRFLUORFMFNDFPFRCFRDFTGFVGGAGALVGASKGCGRFLEXIBLEFLOOR (ING)FLUORESCENTFLOOR MOUNTEDFOUNDATIONFIREPROOF (ING)GRADE (ING)GENERAL CONTRACT (OR)GASKET (ED)GALVANIZEDGAUGEFLUSH VALVEFOOTINGFIRE AND SMOKE DAMPERFIRE RESISTANT COATINGGASFF FINISH FLOOR, FACTORY FINISHDEGREESDEGEXGEXP EXPANSIONEXISTINGELECTRICAL CONTRACTORDETAILDUMBWAITER, DISHWASHEREASTEACHELECTRIC (AL)ELEVATION, ELEVATOREMERGENCYENCLOSUREEDGE OF DECKEDGE OF SLABEQUALEQUIPMENT CONTRACTOREQUIPMENTDRAWINGDAMPPROOF (ING)DOWNDIVISIONDIMENSIONEQUIPEQCEQEOSEODENCEMELEVELECECEAEDWDTLDWGDPDNDIVDIMDIAGDIADFDETDEMODDCDCDIAGONALDIAMETERDRINKING FOUNTAINDETAILDEMOLISHDIRECT DIGITAL CONTROLDIRECT CURRENTCOMBINATIONCOMBBSMT BASEMENTBACKSPLASHCONDUITCABINETCIRCUIT BREAKERCEMENTBSPLCCABCBCEMCGCHCHANCHUVCIPCIRCCLCLGCLRCLRMCMUCOLCOMPCONCCONDCONNCONSTCONTCTCEILING GRILLECABINET HEATERCHANNELCEILING HUNG UNIT VENTILATORCAST IN PLACECIRCUMFERENCECENTER LINECEILINGCOMPUTER TERMINALCONTINOUSCONSTRUCTIONCONNECTIONCONDUITCONCRETECOLUMNCONCRETE MASONRY UNITCLASSROOMCLEAR (ING)COMPRESS (ED) (ION) (IBLE)CENTERCABINET UNIT HEATERCUHCTRBODBOTBRDG BRIDGINGBOTTOMBOTTOM OF DUCTARCHITECT (URAL)ASBESTOSASPHALTAUTOMATICAVERAGEBOTTOM OF CURBBOARDBOTTOM OF FOOTINGBUILDINGBLOCKBEAMBY OTHERSAPPROXIMATE (LY)ACCESS PANELAMPEREALUMINUMALTERNATEAIR HANDLING UNITABOVE FINISH FLOORBOBMBLKBLDGBOFBDBCAVEAUTOASPHASBARCHAPPROXAPAMPALUMALTAHUAFFADJADDADAADJACENTADDENDUMAMERICAN DISABILITIES ACTBOTTOM OF STEELBOSEXTERIOR, EXTERNALEXTCATV CABLE TELEVISIONCCTV CLOSED CIRCUIT TELEVISIONEMT ELECTRICAL METALLIC TUBINGELECTRIC WATER COOLEREWCGWB GYPSUM WALL BOARDGND GROUNDGYP GYPSUM HEATING/VENTILATING/AIR CONDITIONINGXFMR TRANSFORMERGFI GROUND FAULT INTERRUPTABBREVIATIONS LISTREFER TO DRAWING SET PREPARED BY TOMEI AV CONSULTING LLC FOR POWER, DATA, CONDUIT, PULL BOXES, JUNCTION BOXES, BOX COVERS, LOW VOLTAGE CONTROL CABLING, MOUNT HARDWARE, SUPPORTING STRUCTURES, ETC. RELATED TO AV EQUIPMENT. E.C. IS RESPONSIBLE FOR ALL WORK STATED TO BE INSTALLED OR FURNISHED BY THE E.C. IN THE AFOREMENTIONED DRAWING SET. ALTHOUGH DEVICE BOXES AND CONDUIT (WITH PULL STRING) RISERS ARE NOT SHOWN ON THIS ELECTRICAL SET, IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLETE THIS WORK AS SHOWN ON THE AV DRAWING SET. ADDITIONALLY, IT IS THE CONTRACTOR'S RESPONSIBLITY TO INSTALL ALL LOW VOLTAGE CABLES (CABLES TO BE SUPPLIED BY OTHERS).AUDIO/VISUAL SCOPE OF WORKBASIS OF DESIGN FOR RENOVATION LIGHTING CONTROLS - STANDALONE, STEM MOUNTED, PASSIVE INFRARED VACANCY SENSORS. ACUITY CONTROLS CM 9 OR CMR 9. PROVIDE PP20 POWER PACK WHERE REQUIRED.1. CONTRACTOR SHALL PROVIDE PASSIVE INFRARED MOTION SENSORS IN MEETING ROOMS, OPEN SPACES, WORKSHOPS, AND SIMILAR SPACES.2. MOTION SENSORS SHALL HAVE AN ADJUSTABLE, 30-MINUTE MAXIMUM TURN-OFF TIME DELAY. CONTRACTOR TO COORDINATE WITH OWNER IN FIELD FOR TURN-OFF TIME DELAY SETTING.3. IN SPACES WHERE MORE THAN ONE MOTION DETECTOR IS PRESENT, THE DETECTORS SHALL BE CONNECTED IN PARALLEL FOR EXPANDED DETECTION AND TO ACT AS ONE CONTROL ZONE COVERING THE ENTIRE SPACE.4. ALL LIGHTS TO BE MANUAL ON, AUTOMATIC OFF.LIGHTING CONTROL NOTESSheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019Electrical General Notes andLegendE0.01Project Number: 18.007N.T.S.1TYPICAL MOUNTING HEIGHTS DETAILNo. Description Date
DNFSMSMSMSMSMSMSMDFHH2233 31EXISTING ELECTRICAL EQUIPMENT TO REMAIN (TYP.)EXISTING FACP TO REMAINSINGLE RECEPTACLE MOUNTED ON CEILING FOR LIGHT FIXTURE POWER CORD. (TYP.)LKJH764.53M5421GFEDCBAD.5C.5B.57.5C.74LLP-2555CIT-EXISTING IT ROOMPP-APP-1PP1ARP1664LIBRARY STACKSABANDONEDAREAWAY-ELEVATOR LOBBY-CRAWL SPACE-MACHINE ROOM-JANITOR CLOSET-STORAGE-MECH ROOM-StorageB05ATRANSFORMER VAULT-MECHANICAL ROOM-ELEVATOR-Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019Basement Demolition PlanE1.01Project Number: 18.007 1/8" = 1'-0"1Demolition Floor Plan - Level 00KEY NOTESEXISTING CABLE TRAY TO REMAIN.EXISTING WIRELESS ACCESS POINTS TO BE REMOVED AND RETURNED TO CORNELL UNIVERSITY CIT. REMOVE EXISTING BACK BOX AND CABLING BACK TO IT ROOM. REMOVE EXISTING CONDUIT BACK TO EXISTING CABLE TRAY. SURFACE RACEWAY WITH RECEPTACLES TO BE REMOVED. REMOVE ALL ASSOCIATED CIRCUITRY, BOXES, AND DEVICES BACK TO SOURCE PANEL IN MECHANICAL ROOM.REMOVE EXISTING FIRE ALARM INITIATION/NOTIFICATION DEVICE. REMOVE ASSOCIATED BOXES, CONDUIT, AND WIRING BACK TO NEAREST ACCESSIBLE JUNCTION BOX. PHASE REMOVAL OF EXISTING DEVICES WITH THE INSTALLATION OF NEW DEVICES SUCH THAT THE SPACE MAINTAINS INITIATING/NOTIFICATION CAPABILITIES THROUGHOUT FULL CONSTRUCTION DURATION.REMOVE EXISTING DUAL HEAD EMERGENCY LIGHT FIXTURES. REMOVE ASSOCIATED BOXES, CONDUIT, AND WIRING BACK TO SOURCE POWER PANEL LLP-2. STORE AND MAINTAIN (1) FIXTURE FOR REINSTALLATION.REPLACE EXISTING SMOKE DETECTORS WITH HEAT DETECTORS COMPATIBLE WITH EXISTING FCI FIRE ALARM SYSTEM (FC-72 FACP). STORE EXISTING SMOKE DETECTORS IN A DRY AND COOL LOCATION FOR REINSTALLATION IN SAME LOCATION AFTER CONSTRUCTION HAS REACHED A POINT OF SUBSTANTIAL COMPLETION.123GENERAL NOTES1. REMOVE ALL EXISTING LIGHTING FIXTURES, LIGHTING CONTROL DEVICES, DATA OUTLETS, RECEPTACLES, ETC. SHOWN AS DARK &/OR DASHED UNLESS OTHERWISE NOTED. REMOVE ALL ASSOCIATED BOXES, EXPOSED CONDUIT, AND WIRING BACK TO SOURCE POWER PANEL IN MECHANICAL ROOM UNLESS OTHERWISE NOTED. 456PLANNORTHNo. Description Date
DNFBDDDDDDWB WB WBWBWB DCDDDDJWB
WB DD D D D
D
D DMech WorkshopB05HMeeting Room 06B05JMeeting Room 05B05GLoungeB05FMeeting Room 01B05BMeeting Room 04B05ESystems EngineeringLabB05LLP-2PP-3PP-4-12PP-4-3PP-4-21PP-4-16PP-4-14PP-4-2PP-4-5 PP-4-17PP-4-18PP-4-23PP-4-24PP-4-11PP-4PP-4-911117Meeting Room 03B05DMeeting Room 02B05CPP-4-20PP-4-2212PP-4-35334CIT-AHU-1PP-4-15PP-4-8PP-4-6PP-4-13PP-4-777777LKJH764.53M5421GFEDCBAD.5C.5B.57.5C.7542"PP-4-10PP-4-19P-1P-2F-2F-13/4HP(2,0,15)(2,0,20)PP-17PP-1-33PP-4-2600100869PP-1-34PP-1-35PP-1-361717101010PP-1-37PP-1-3711777PP-1-38PP-APP-4-37,39,4142"PP-1-31777777PP-A-26,28,30810HPPP-4-36,38PP-4-40,42111111111111111111711TRANSFORMER VAULT-AREAWAY-ELEVATOR LOBBY-CRAWL SPACE-JANITOR CLOSET-StorageB05ALIBRARY STACKSABANDONEDMECH ROOM-STORAGE-MECHANICAL ROOM-ELEVATOR-MACHINE ROOM-Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019Basement Power, Security, &Telecom PlanE2.01Project Number: 18.007 1/8" = 1'-0"1Renovation Power, Security, & Telecom Plan - Level 00KEY NOTESPROVIDE A LARGE STORAGE WALL BOX RECESSED IN WALL. BASIS OF DESIGN CHIEF PAC526. PROVIDE A DUPLEX RECEPTACLE RECESSED IN WALL BOX. PROVIDE A PANDUIT MINICOM 2-POSITION "106" SERIES FRAME ADAPTER FOR (2) DATA DROPS INSTEAD OF THE STANDARD EXECUTIVE SERIES FACEPLATE SPECIFIED IN DIVISION 27 SPECIFICATIONS. REFER TO TOMEI AV CONSULTING DRAWING SET FOR ADDITIONAL INSTALLATION DETAILS, INCLUDING BUT NOT LIMITED TO MOUNTING, CONDUITS, COMPATIBLE JUNCTION BOXES, RECEPTACLE, AND DATA REQUIREMENTS. PROVIDE A FLUSH 4-GANG FLOOR BOX DESIGNED TO BE INSTALLED IN CONCRETE. PROVIDE (2) DUPLEX RECEPTACLES, (1) 4-DROP DATA DEVICE PLATE, AND (1) BLANK. PROVIDE TRIM RING, FLUSH STYLE COVER AND ALL MISC. ACCESSORIES FOR A FULLY FUNCTIONAL INSTALLATION. SAW CUT INTO EXISTING SLAB TO NEAREST WALL AS SHOWN FOR CONDUIT FEEDS TO FLOOR BOX. PROVIDE AN ADDITIONAL 1-1/4" SPARE CONDUIT IN TRENCH. REPAIR SURFACE AFTER INSTALLATION IS COMPLETE WITH 5000 PSI CONCRETE. BASIS OF DESIGN: LEGRAND EVOLUTION SERIES EFB45. REFER TO 2/E4.01 FOR ADDITIONAL INFORMATION.PROVIDE A 120/208V, 3PH, 4W, 225A MAIN, 150A MCB, 42 CIRCUIT PANELBOARD PP-4. PROVIDE RGS CONDUIT WITH STEEL STRUT SUPPORT/BRACING AS REQUIRED TO MOUNT FREE STANDING PANELBOARD. PROVIDE A 150A, 3PH CIRCUIT FROM EXISTING SQUARE D SERIES E1 I-LINE PANELBOARD PP-3 AND A 150A, 3P COMPATIBLE BREAKER WITH 22KAIC. USE (4) 1/0, (1) #8G IN 2" EMT. PROVIDE ACCESS CONTROLS CABLING/EQUIPMENT PER 1/E4.02 AT DOOR 008. LOCATE NEW LNL 1320 DUAL READER INTERFACE MODULE AND NEW ALTRONIX AL175ULX2 POWER SUPPLY (AND ASSOCIATED ENCLOSURES), ON SECURE SIDE OF DOOR.PROVIDE ACCESS CONTROLS CABLING/EQUIPMENT PER 1/E4.02 AT DOOR 001.PROVIDE A 208V, 3PH, 10HP VARIABLE FREQUENCY DRIVE WITH 35A FUSES FOR AHU-1. MOUNT TO UNIT. PROVIDE CIRCUIT FROM EXISTING 400A, 120/208V, SQUARE D NQOD MECHANICAL EQUIPMENT PANEL PP-A. REMOVE EXISTING BREAKER IN SPACES INDICATED AND PROVIDE A NEW COMPATIBLE 40A, 3P CIRCUIT BREAKER.REFER TO AV DRAWING SET PREPARED BY TOMEI AV CONSULTING LLC FOR MOUNTING LOCATIONS, MOUNTING HEIGHTS, ADDITIONAL ROUGH-IN LOCATIONS, MOUNTING BRACKETS, SUPPORTING STRUCTURES, CONDUITS WITH PULL STRING, AND LOW VOLTAGE CABLING REQUIRED AT LOCATION.PROVIDE A 208V, 3PH, 3/4HP VARIABLE FREQUENCY DRIVE WITH 5A FUSES FOR F-1. MOUNT TO UNIT.PROVIDE A 120V, 20A, GENERAL PURPOSE AC TOGGLE SWITCH TO CONTROL OUTLET. OUTLET INTENDED TO SERVE A PLUG-IN DUST COLLECTOR.EXISTING CABLE TRAY SHOWN FOR REFERENCE. ALL DATA CABLING TO ROUTE BACK TO CIT ROOM THROUGH CABLE TRAY. REFER TO 3/E4.01 FOR DATA RISER DIAGRAM.ALL NEW AUDIO/VISUAL RELATED CIRCUITS AND RECEPTACLES TO BE FED FROM EXISTING PANEL PP-1. PP-1 IS A 225A, 120/208V, 3PH, 4W, SQUARE D, NQOD PANELBOARD WITH SPACES IN CIRCUITS 31, 33-42. PROVIDE 20A CIRCUIT BREAKERS AS REQUIRED FOR ALL NEW AV CIRCUITS. MODIFY EXISTING PANEL SCHEDULE BY PRINTING TYPED LABELS FOR EACH NEW CIRCUIT AND PASTING IT TO EXISTING PANEL SCHEDULE IN THE FOLLOWING FORMAT: "AUDIO/VISUAL RECEPTACLE - (ROOM #)".1234567891011PLANNORTHNo. Description Date
FVVVVDDDDV
V VFVVVFVD DDPL3VPLJPPPLPPPPPPPLPLDP PLPLPLPLPL43FJF31E2.03F1F1F1EF1EF1EF1EF1F1Meeting Room 04B05EMeeting Room 01B05BLoungeB05FMeeting Room 05B05GSystems EngineeringLabB05Mech WorkshopB05HMeeting Room 06B05JF3EF3F2F2F2EF2F1EF1F2EF2EF2EF2F2F3F2EF2F2EF3F1F2X1EXISTING CONVENTIONAL FCI (FIRE CONTROL INSTRUMENTS) FCI-72 FACPF3EF1F1EF1F1F1F1EF1F1F1EX1PP-4110WPPP-4-25PP-4-1(TYP. ALL EXIT SIGNS)7575PP-4-4Meeting Room 03B05DMeeting Room 02B05CF1EF6F4LKJH764.53M5421GFEDCBAD.5C.5B.57.5C.7PP-4-1X1X1TO EXISTING STAIRCASE LIGHTING CIRCUIT AND CONTROLSETRF6F6F6F6F6F4F4F4F4F4F4F4F4F42E2.03MOUNTED AT 8' 6" AFF MEASURED FROM TOP OF FIXTURE. REFER TO 1/E0.01 FOR MOUNTING HEIGHTS OF ALL OTHER FIXTURESF5F5F5F5F5F5F5ACOUSTICAL CEILING TILE (TYP). COORDINATE LIGHT FIXTURE LOCATIONS WITH TILES.SWITCH AND ELECTRICAL FEED TO LIGHTED SIGN. COORDINATE MOUNTING HEIGHT AND FINAL LOCATION OF JUNCTION BOX WITH SIGNAGE VENDORPP-4-27DSSAT SUPPLY AND RETURN DUCTS SERVING AHU-1. TYPICAL OF 2DIGITAL TIME CLOCK80" ABOVE LANDINGTO F5 FIXTURES30AREAWAY-TRANSFORMER VAULT-CIT-MECHANICAL ROOM-ELEVATOR LOBBY-CRAWL SPACE-ELEVATOR-MACHINE ROOM-JANITOR CLOSET-STORAGE-StorageB05ALIBRARY STACKSABANDONEDMECH ROOM-Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019Basement Lighting & Fire AlarmPlanE2.02Project Number: 18.007 1/8" = 1'-0"1Renovation Lighting & Fire Alarm Plan - Level 00PLANNORTHNo. Description Date
JHJHFloor - Level 010"Floor - Level 00-13' - 0"JHF5F5F5F5F5F5F5TYPICAL FOR ALL F5 FIXTURES UNLESS OTHERWISE NOTEDCOORDINATE INSTALLATION OF FIXTURES WITH NEW CONCRETE RETAINING WALL (TYP)1' - 0"0' - 7"EQEQNOTE: ALL F5 FIXTURES TO BE CONTROLLED BY DIGITAL TIME CLOCK THROUGH A REMOTE INVERTER120VCMR 9LIGHTING LOADNEUTRALMEETING ROOMS, MECH WORKSHOP, LOUNGESYSTEMS ENGINEERING LABDIMMER SWITCH+-(0-10V)EXTERIOR STEP LIGHTS120VCM 9CM 9PP20LIGHTING LOADNEUTRAL3-WAY DIMMER SWITCHQUANTITY OF VACANCY SENSORS AS SHOWN ON PLANS120VF5 FIXTURESNEUTRALSINGLE PHASE REMOTE LIGHTING INVERTER, 250VABASIS OF DESIGN MODEL NUMBERS:DESCRIPTIONPIR MOTION SENSOR - LINE VOLTAGEPIR MOTION SENSOR - LOW VOLTAGEPOWER PACKDIGITAL ASTRONOMIC TIME CLOCKREMOTE LIGHTING INVERTERMANUFACTURERACUITYACUITYACUITYNSI INDUSTRIESHUBBELLMODEL NUMBERCMR 9CM 9PP20DGLC100A-NCLG-250SIASTRONOMIC TIME CLOCK, 1CH 20A, 120-277V4-WAY SWITCH3-WAY SWITCH+-(0-10V)Floor - Level 010' - 0"Floor - Level 0212' - 4"KJ22' - 6"EQEQF7EF8EMOUNT WALL PACKS TO EXISTING BUILDING EXTERIOR. TAP OFF EXISTING INTERIOR CLASSROOM LIGHTING CIRCUIT ON SECOND FLOOR FOR POWER TO BOTH WALL PACKS. SPLICE AHEAD OF ANY EXISTING SWITCHES OR LIGHTING CONTROL DEVICES. WALL PACKS TO BE CONTROLLED BY INTEGRAL PHOTOCELL. SEAL ALL PENETRATIONS10' - 2"Sheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019Lighting DetailsE2.03Project Number: 18.007 1/4" = 1'-0"1STEP LIGHT INSTALLATION DETAILN.T.S.3LIGHTING WIRING SCHEMATICLighting Fixture ScheduleType Mark Description Manufacturer Model Voltage Mounting WattageF1 Corelite LED 8' Suspended Linear Cooper Lighting HGL-S-FR-50L-835-1-D-UNV-STD-W-AC38-UM-875 WF1E Corelite LED 8' Suspended Linear withIntegral BatteryCooper Lighting HGL-S-FR-50L-835-1-E-UNV-STD-ILB12-W-AC38-UM-875 WF2 Metalux LED 8' Industrial Linear Bay Cooper Lighting 8ILED-LD5-10-W-FL-UNV-L835-CD1-U 65 WF2E Metalux LED 8' Industrial Linear Bay withIntegral BatteryCooper Lighting 8ILED-LD5-10-W-FL-UNV-L835-EL14W-CD1-U65 WF3 Metalux LED 4' Industrial Linear Bay Cooper Lighting 4ILED-LD5-5-W-FL-UNV-L835-CD1-U 33 WF3E Metalux LED 4' Industrial Linear Bay withIntegral BatteryCooper Lighting 4ILED-LD5-5-W-FL-UNV-L835-EL14W-CD1-U33 WF4 Metalux LED 2' Striplight Cooper Lighting 2SLSTP2035DD-UNV23 WF5 LED Recessed Round Step Light H.E. Williams SR-C-L7/835-FTG-GRAY-DIM-12022 WF6 6" Acrylic Tube LED Pendant Prima Lighting 2846F-E6-LD-SV-SC-1A-35812 WF7E Exterior Wall Pack (CU Type B1) H.E. Williams VWPH-L30/730-T3-SLV-CGL-PC-EM/10WC-DIM-12036 WF8E Exterior Wall Pack (CU Type A1) H.E. Williams VWPH-L60/730-T3-SLV-CGL-PC-EM/10WC-DIM-12070 WX1 LED Exit Sign with NiCad Battery Cooper Lighting APLX7RGUNVUNVUNVUNVUNVUNVSuspendedSuspendedStemStemStemStemUNVUNV1 WUNVSurface120VWallUNVSuspended120VWall120VWall 1/8" = 1'-0"2WALL PACK INSTALLATION DETAILNo. Description Date
FIRE ALARM PULL STATIONAUDIO/VISUAL DEVICE - 15/75 cdFIRE ALARM LEGENDINITIATION CIRCUITNOTIFICATION CIRCUITFFNOTE: THIS DETAIL IS DIAGRAMATICAL ONLY. SEE DRAWINGS FOR DEVICE COUNTSEXISTING FIRE CONTROL INSTRUMENTS FCI-72 FIRE ALARM CONTROL PANEL (CONVENTIONAL)FVFEXISTING INITIATION AND NOTIFICATION APPLIANCE CIRCUITS TO REMAINN/AMODEL NO.N/AMS-7P2RLADD TO EXISTING BASEMENT ZONE 1. CLASS B WIRINGEXISTING SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL LOCATED AT THE BOTTOM OF FACP. MODEL NO. FCI SNAC-9.POWER SUPPLYEVENLY DISTRIBUTE NEW LOADS ON THE (2) EXISTING CIRCUITS. CLASS A WIRING. VERIFY EXISTING BATTERY IN SNAC-9 PANEL IS SIZED SUFFICIENTLY TO MEET POWER SUPPLY REQUIREMENTS OF NFPA 72. UPSIZE AS REQUIRED.RELAYPROVIDE A SUPERVISED RELAY MODULE WITH DUAL RELAYS FOR ACCESS CONTROLS TIE-IN AND HVAC UNIT SHUTDOWN. NEW BASEMENT DUCT DETECTOR ZONE. CLASS B WIRING, SUPERVISORY SIGNAL. REUSE SPARE ZONESVISUAL ONLY DEVICE - 15/75 cdFIRE ALARM LEGENDVMODEL NO.SRLWEATHERPROOF AUDIO/VISUAL DEVICE - 110 cdFP2RKWPSDUCT SMOKE DETECTORD4120PROVIDE DUCT DETECTOR WITH REMOTE INDICATOR/TEST/RESET STATION. MOUNT REMOTE INDICATOR/TEST/RESET STATION IN ACCESSIBLE LOCATION.EXISTING NOTIFICATION APPLIANCE CIRCUIT CURRENT READINGS:FACP CIRCUIT #1: 1.0 AFACP CIRCUIT #2: 1.7 A (MAX)SNAC-9 CIRCUIT #1 & #2: 0.8 A, CLASS ASNAC-9 CIRCUIT #3 & #4: 0.6 A, CLASS AFIRE ALARM VENDOR CONTACT INFORMATION:TIMOTHY R. MCGEEVICE PRESIDENT/CHIEF OPERATING OFFICERWEST FIRE SYSTEMS. INC.TMCGEE@WESTFIRESYSTEMS.COM(585) 663-8530 EXT. 103TO ACCESS CONTROL POWER SUPPLY. FAIL-SECURE OPERATION DURING FIRE ALARM EVENT.TO CONTROL RELAYS AT AHU-1 AND F-1 FOR UNIT SHUTDOWN. CONTROL RELAYS AT UNITS SHALL BE UL-LISTED AND SUITABLE FOR USE WITH FIRE ALARM AND HVAC. MODEL NO. MR-101/CRRELAYSUPERVISED RELAY MODULESRB-6(1) 1-1/4" CONDUIT WITHIN FLOOR TO CLOSEST WALL FOR DATA. PROVIDE CONDUIT TO EXISTING CABLE TRAY AND CABLING BACK TO IT ROOM. PANDUIT MINI-COM UTP JACK MODULE FOR CAT6 CABLES. PART NUMBER CJ688TG.PANDUIT EXECUTIVE SERIES FACEPLATE WITH (2) 1/2 FLAT INSERTS FOR A TOTAL OF (4) DATA DROPS. PART NUMBER CBEE1YLABEL OUTLET IN ACCORDANCE WITH OUTLET NUMBER CONFIGURATION OBTAINED FROM CIT (TYP.)125V-20A RECEPTACLE (TYP.)BLANK DEVICE PLATEMOUNTING BRACKET HOLDING UP TO (4) DEVICES. ACCEPTS STANDARD SIZE 2.75" X 4.5" DEVICE PLATES.(1) 1-1/4" CONDUIT WITHIN FLOOR TO CLOSEST WALL AS A SPAREGENERAL NOTES:1. PROVIDE ALL MISC. BRACKETS, BARRIERS, DEVICES, DEVICE PLATES, AND ACCESSORIES FOR A COMPLETE AND FUNCTIONAL INSTALLATION AS INDICATED.2. COORDINATE ROUTING OF IN FLOOR CONDUITS WITH GENERAL CONTRACTOR.3. REFER TO FLOOR PLANS FOR ACTUAL DEVICE QUANTITIES AND LOCATIONS.4. PROVIDE ALL NECESSARY MOUNTING PROVISIONS AND CONDUIT SLEEVES.5. DETAIL IS GENERIC AND MEANT TO SHOW INTENT ONLY. REFER TO SUBMITTED MANUFACTURER SHOP DRAWINGS FOR ACTUAL KNOCKOUT LOCATIONS4-GANG RECESSED FLOOR BOX WITH FLUSH COVER AND AN EPOXY COATING FOR ON-GRADE APPLICATIONS . BASIS OF DESIGN LEGRAND WIREMOLD EFB45-OG(1) 3/4" CONDUIT WITHIN FLOOR TO CLOSEST WALL FOR POWER:CIT ROOMBASEMENTTYPICAL DATA OUTLETPROVIDE 1" CONDUIT AND CAT6 CABLING TO CIT ROOM THROUGH EXISTING CABLE TRAY FOR ALL DATA DROPS.PROVIDE 1" CONDUIT AND CAT6A CABLING TO CIT ROOM THROUGH EXISTING CABLE TRAY FOR ALL WAP ROUGH-IN LOCATIONS.TYPICAL WIRELESS ACCESS POINT DEVICE BOX. DEVICE TO BE PROVIDED AND INSTALLED BY OWNER.NEATLY SPOOL 25' OF CAT6/CAT6A CABLING FOR ALL CABLE RUNS. ALL FINAL TERMINATIONS TO DATA RACKS TO BE DONE BY OWNER.EXISTING DATA RACK (SHOWN FOR REFERENCE ONLY)EXISTING CABLE TRAYSheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019Electrical DetailsE4.01Project Number: 18.007Notes:Receptacle11880 VA 92.09% 10940 VATotal Est. Demand Current:47 APower600 VA 100.00% 600 VATotal Conn. Current:55 AOther3 VA 100.00% 3 VATotal Est. Demand:17018 VALighting2822 VA 100.00% 2822 VATotal Conn. Load:19727 VAHVAC4422 VA 60.00% 2653 VALoad ClassificationConnected Load Demand Factor Estimated Demand Panel TotalsLegend:Total Amps:45 A 64 A 70 ATotal Load:5441 VA 7407 VA 8139 VAPP-4-41 ---- --420 VA 1082... -- -- --PP-4-42PP-4-39 ---- -- 420 VA 1082... 2 20 A P-2PP-4-40PP-4-37 F-120 A 3 420 VA 302 VA-- -- --PP-4-38PP-4-35 F-220 A 11656... 302 VA 2 20 A P-1PP-4-36PP-4-33 Spare20 A 1 0 VA 0 VA 1 20 A SparePP-4-34PP-4-31 Spare20 A 1 0 VA 0 VA1 20 A SparePP-4-32PP-4-29 Spare20 A 10 VA 0 VA 1 20 A SparePP-4-30PP-4-27 Time Clock - Exterior Step Lights 20 A 1 50 VA 0 VA 1 20 A SparePP-4-28PP-4-25 Lighting - Meeting Rooms 20 A 1 1495... 500 VA1 20 A Access Controls - Systems Engineering Lab B05 PP-4-26PP-4-23 Receptacle Systems Engineering Lab B05 20 A 1720 VA 900 VA 1 20 A Receptacle Room B05, B05H PP-4-24PP-4-21 Receptacle Meeting Room 02 B05C 20 A 1 900 VA 900 VA 1 20 A Receptacle Meeting Room 01 B05B PP-4-22PP-4-19 Receptacle Systems Engineering Lab B05 20 A 1 360 VA 540 VA1 20 A Receptacle Mech Workshop B05H PP-4-20PP-4-17 Laser Cutter Systems Engineering Lab B05 20 A1180 VA 360 VA 1 20 A Receptacle Systems Engineering Lab B05 PP-4-18PP-4-15 Receptacle Meeting Room 05 B05G 20 A 1 720 VA 540 VA 1 20 A Receptacle Meeting Room 05 B05G PP-4-16PP-4-13 Chop Saw EF Systems Engineering Lab B05 20 A 1180 VA 180 VA1 20 A 3D Printer Systems Engineering Lab B05 PP-4-14PP-4-11 Receptacle Meeting Room 06 B05J 20 A 1720 VA 1080... 1 20 A Receptacle Meeting Room 04 B05E PP-4-12PP-4-9 Receptacle Systems Engineering Lab B05 20 A 1 180 VA 360 VA 1 20 A Receptacle Lounge B05F PP-4-10PP-4-7 Receptacle Systems Engineering Lab B05 20 A 1 540 VA 720 VA1 20 A Receptacle Room B05H, B05 PP-4-8PP-4-5 3D Printer Systems Engineering Lab B05 20 A 1180 VA 540 VA 1 20 A Receptacle Systems Engineering Lab B05 PP-4-6PP-4-3 Receptacle Meeting Room 03 B05D 20 A 1 900 VA 1355... 1 20 A Lighting - Open Space PP-4-4PP-4-1 Exit Signs Systems Engineering Lab B05 20 A 1 25 VA 180 VA1 20 A 3D Printer Systems Engineering Lab B05 PP-4-2CKT Circuit Description Trip PolesA B CPoles Trip Circuit Description CKTNotes:Enclosure:Type 1MCB Rating:100 AMounting:SurfaceWires:4Mains Rating:100 ASupply From:PP-3Phases:3Mains Type:MCBLocation:MECHANICAL ROOM -Volts:120/208VA.I.C. Rating:22,000Branch Panel: PP-4N.T.S.1FIRE ALARM RISER DIAGRAMN.T.S.2FLOOR BOX DETAILN.T.S.3DATA RISER DIAGRAMNo. Description Date
EXISTING LNL-2200 INTELLIGENT SYSTEM CONTROLLER (ISC)LNL-1320 DUAL READER INTERFACE MODULEALTRONIX AL175ULX2 POWER SUPPLY120V(PP-4-26)FIRE ALARM TIE-INSARGENT M1 80 SERIES, INTEGRATED WIEGAND CARD READER, ELECTRIC LOCK, DOOR POSITION SWITCH, AND REQUEST TO EXIT DEVICE BY G.C.. REFER TO DOOR HARDWARE SPECIFICATIONS FOR MORE INFORMATION.RECESSED DOOR CONTACT. GE 1076BASEMENT MECHANICAL ROOMEXISTING FCI FC-72 FACPSARGENT 3287 DOOR POSITION SWITCH BY G.C.1CABLE SCHEDULE1CONSTANT OUTPUT (12/24VDC), 18AWG TWISTED PAIR22-WIRE RS-485 (24AWG TWISTED PAIR WITH SHIELD) AND GROUND. BELDEN #984232 CONDUCTOR #22 AWG, DOOR CONTACT / DOOR POSITION SWITCH. BELDEN #8442256 CONDUCTOR #22 AWG, SHIELDED, CARD READER. BELDEN #9942JBOXTRIGGER62 CONDUCTOR #18 AWG, DOOR STRIKE POWER. BELDEN #846172 CONDUCTOR #22 AWG, REQUEST TO EXIT, BELDEN #8442336573567DOOR 008DOOR 001SECURE SIDE DOOR 0084UNUSEDSheet Number45 LEWIS STREET BINGHAMTON, NY 13901607.217.7013www.L2studioarch.comOwner:Project Address:Professional Seal:RevisionsNOTICE: It is a violation of the law for any person, unless acting under the direction of a licensed architect, to alter this Drawing in any way. If alterations are made to this Drawing, when bearing the seal of an architect, the altering party shall affix their own professional seal to his/her revisions, and add the notation "altered by" followed by his/her signature and the date of such alteration, and a specific written description of the alteration(s) made.FINAL BID SETSheet TitleConsultant:49 COURT STREETP.O. BOX 1980BINGHAMTON, NY 13902TEL: 607-723-9421MJINC.COMCarpenter Hall B05 Systems Engineering Lab CodeComplianceCornell University313 Campus RdIthaca, NY 14850Date: 03.05.2019Electrical DetailsE4.02Project Number: 18.007N.T.S.1ACCESS CONTROLS WIRING SCHEMATICNo. Description Date