HomeMy WebLinkAbouts1021
FOUNDATION DRAIN,
SEE C103 AND A501
2
REBUILD PORCH STEPS
TO MATCH EXIST
STEP FOOTING DOWN AS
REQ'D TO MATCH B/EXIST
FOOTING
REBUILD FOUNDATION
WALLS WHERE REMOVED
REBUILT PORCH
FRAMING (TYP)
TOP PAINTED TONGUE
AND GROOVE PORCH
BOARD TO MATCH
EXISTING (TYP)
3
SEE L301 FOR
ELEVATIONS OF
EXIST FIN FLR
CONCRETE PIER AND FOOTINGS
NEW PORCH FRAMING
BEARING ON NEW PIER
7x11,875 WOLMANIZED TJ PARALLAM
AT EA INTERIOR GIRDER (TYP)
5.25x9.5 WOLMANIZED TJ PARALLAM
AT EA DOUBLE GIRDER (TYP)
4
3A
3'-2"
/ /
S301
FIRST FLOOR - Phase 3 Rebuilt
1/8" = 1'-0"
3'-2"
5
GALV L6x4x5/16 (LLV) (TYP
OF TWO)
ALUMINUM GRATING (TYP)
AT 3 AREAWAYS. SEE ARCH
DRAWINGS.
REBUILD AREAWAY (TYP OF
THREE)
PROVIDE CONTROL
JOINTS WHERE
SHOWN
NEW CONCRETE
RAMP. SEE C1/A503
FOR GEOMETRY.
STEP FOOTING DOWN AS
REQ'D TO MATCH B/EXIST
FOOTING
REBUILD PORCH STEPS
TO MATCH EXIST
REBUILD PORCH FRAMING
WITH PRESSURE TREATED
NO.1/N0.2 2x10 SPRUCE -
PINE -FIR JOISTS AT 16" OC
OR EQUIVALENT
6
7
NAILING SCHEDULE
LOCATION
REQUIREMENTS
JOIST TO GIRDER
3-8d COMMON, TOE NAIL
JOIST TO SILL
3-8d COMMON, TOE NAIL
JOIST TO RIM JOIST
3-16d COMMON, END NAIL
BLOCKING TO JOIST
2-8d COMMON EA END, TOE NAIL
TONGUE AND GROOVE DECKING TO JOIST
2-8d COMMON, FACE NAIL
8
9
10
RYAN BIGGS
CLARK DAVIS
4592 JORDAN ROAD
SKANEATELES FALLS, NY 13153
p 315.685,4732 f 315.685.4753
www.ryanbiggs.com
E
U
0
0
c
0
0
0
U
a)
is
0
•
•
0
CO
0
LL
C
to N 0-
_1_0=
E U
(0
a) 2 criP
0) a (/)
E o0
haca, New York 14850
DATE:
14 December 2018
PROJECT:
1711
E
D
C
B
OTHER:
DRAWN BY:
Author
PHASE 3
REBUILT PLAN
S102
A
1
2
4
5
6
7
8
10