Loading...
HomeMy WebLinkAboutCornell-Statler-Hall-Elevator_Drawing-SetArchitectural Resources 505 Franklin Street Buffalo, NY 14202 303 West 13th Street New York, NY 10014 716 883-5566 716 883-5569 fax mail@archres.com Statler Hall and Hotel Elevator Modernization and Fire Alarm Upgrade 7 East Ave, Ithaca, NY, 14583 Bid Documents 05.18.2018 A I r 564.07 Site Location Consultants ADELTA Drawing List G-001 A-101 General A-102 General A-401 Construction A-402 Construction A-403 Construction A-501 Construction A-502 Construction H-401 HVAC H-402 HVAC H-500 HVAC E-100 Electrical E-101 Electrical E-102 Electrical E-401 Electrical E-402 Electrical E-501 Electrical E-502 Electrical Cover Sheet Floor Plans, Legends, and General Notes Second and Third Thru Fifth Floor Plans Elevators #1 and #2 Enlarged Floor Plans Elevators #3 and #5 Enlarged Floor Plans Elevators #1, #2, #3, and #5 Elevations Architectural and Elevator Details Architectural and Elevator Details Elevators # I, #2, #3, and #5 Enlarged Floor Removal Plans Elevators #1, #2, #3, and #5 Enlarged Floor Plans Symbols, Abbreviations, Schedules, Details, and Notes General Notes and Symbols Ground Floor & First Floor Plan 2nd Thru Roof Elevators #1 and #2 Enlarged Floor Plans Elevators #3 and #5 Enlarged Floor Plans Details Details D 2 L oa 0 iv D c 0 0 0 N c i Q) D 0 0 and Hotel Eleva 564.07 Sta 05.18.2018 Bid Documents 77.=-117- .= 17 , :: A. ALL DIMENSIONS ARE TO THE FINISHED FACE OF SURFACES UNLESS OTHERWISE NOTED B. THE CONTRACTOR IS NOT TO SCALE DRAWINGS OR DETAILS. C. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH THE REQUIREMENTS OF LOCAL AUTHORITIES THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCITON AREA, THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR STRUCTURAL OR REMOVAL TASKS. Architectural Resources 71688 113202 New Yrr1 1001 1' x566 716-883-55 E. THE CONTRACTOR SHALL PERFORM ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE D DRAWINGS. F. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL SCOPE. 100311 EVATOR REFERENCE LABEL SECTION NUMBER SHEET NUMBER REFERENCE LABEL DETAIL NUMBER SHEET NUMBER OMEN SIME116 a ROOM NAME, NUMBER AND CEILING TYPE ACT - ACOUSTIC CEILING TILE EXP - EXPOSED CEILING TYPE GYP - GYPSUM 74EVATOR #4 • 2016 NEW YORK STATE UNIFORM BUILDING CODE USE AND OCCUPANCY CLASSIFICATION: OCCUPANCY GROUP: MIXED USE • HOTEL: R-1 RESIDENTIAL • HALL: B BUSINESS FIRE RESISTANCE REQUIREMENTS FOR EXISTING BUILDING ELEMENTS (TABLE 601, IBC 2015): GYP .a.. ELEVATOR ATS SPRINKLER PROTECTED: YES EXTERIOR AND INTERIOR LOAD BEARING WALLS: 2 HOURS INTERIOR NON -LOAD BEARING WALLS: NO RATING ROOF SUPPORTING WALLS/FRAMING: 1 HOUR FLOORS: 2 HOURS ROOF: 1 HOUR G65D REPLACE PHASE I AND PHASE II FIREFIGHTERS' OPERATION KEY SWITCHES REMOVE AND STORE EXISTING CEILING TILES FOR INSTALLATION OF CONDUITS AND EQUIPMENT - COORDINATE WITH E -SERIES DRAWINGS AS REQUIRED - REINSTALL CEILING TILES UPON COMPLETION OF WORK OR AS DIRECTED BY OWNER'S REPRESENTATIVE MAIN TELECOM ROOM Floor Plans, Legends, and General Notes A 1r Job No: 564.07 Client No: Drawn by: Sheet No: Architec oral Resources 716-8 �vk 18202 1 rigsr f New Yrrk1001 666 716-883-55 Hotel Typical Floor Plan (6th - 9th) 1"=20-0" Typical Floor Plan (3rd - 5th) = 20'-0" Second and Third Thru Fifth Floor Plans A l r Job No: 564.07 Client No: Drawn by: Sheet No: 1 2 D C B f A 00071 GYP 3 A4 • ELEVATOR #2 • • ELEVATOR #1 H 10 MI11111111110 01111111=1 Enlarged Ground Floor Plan 1/4" = 1'-0" 10049 ACT 127 •0•11110101111II0 • FIRE CONTROL 129 • J 10065 Enlarged Fire Control Room Plan 1/4"= 1'-0" L 1 2 3 123 10064 G0040 ACT • 4 EXISTING 3'-0" X 7-0" ACCESS DOOR 16 • • • • • • • • • • • • L.. 7 20 MACHINE ROOM 10064 EXP L 8— 7 20 32 LINE OF HOISTWAYS BELOW • • • • • • • • • • • •• 00 001111100 00 0101100110 00 0111011.10 00011.11111111100 Enlarged Machine Room Plan 1/4" = 1 `-0° A-403 30072 GYP • 311 Enlarged Typical Floor Plan (3 - 9) 1/4'= 1'-0' 4 Enlarged Second Foor Plan 1/4" = 1'-0" 107 ACT 10037 GYP B4 21 • • • MD 0111111111111110 0 4111111111111110 8' - 4" V.I.F. CLEAR HOISTWAY 8' - 4" V.I.F. Enlarged First Floor Plan 1/4" = 1'-0" 4 CLEAR HOISTWAY CLEAR HOISTWAY G0145 ACT 5 Drawing Notes ## 1 REMOVE EXISTING GEARED HOISTING EQUIPMENT - PROVIDE GEARLESS HOISTING MACHINE AND ALL ASSOCIATED EQUIPMENT INCLUDING BUT NOT LIMITED TOO EMERGENCY BRAKE, BLOCKING BEAMS, AND DEFLECTOR SHEAVE 2 PROVIDE CAR TOP GUARD RAIL 3 EXISTING ELEVATOR HOISTWAY DIVIDER BEAM TO REMAIN - TYPICAL 4 EXISTING ELEVATOR SILL TO REMAIN - TYPICAL 5 EXISTING CAR AND COUNTERWEIGHT GUIDE RAILS FULL HEIGHT TO REMAIN - PREPARE AND PAINT FULL HEIGHT - TYPICAL 6 RETAIN & RESTORE EXISTING CAR FRAME & PLATFORM - REMOVE EXISTING CAR ENCLOSURE IN ITS ENTIRETY - PROVIDE CAR ENCLOSURE - REFER TO SHEET A-501 FOR CAR INTERIOR ELEVATIONS 7 REMOVE EXISTING ELEVATOR CONTROL SYSTEM - PROVIDE ELEVATOR CONTROL SYSTEM 8 REMOVE EXISTING MOTOR GENERATOR IN ITS ENTIRETY 9 APPROXIMATE LOCATION OF ELEVATOR RELATED DISCONNECTS & ELECTRICAL EQUIPMENT - COORDINATE REQUIREMENTS & CONNECTIONS WITH ELECTRICAL CONTRACTOR - REFER TO E -SERIES DRAWINGS FOR LOCATION OF EQUIPMENT 10 REMOVE EXISTING ELEVATOR EQUIPMENT NO LONGER UTILIZED AS PART OF THE MODERNIZATION IN ITS ENTIRETY - INCLUDING, BUT NOT LIMITED TO, ELECTRICAL CONDUITS, WIRE -WAYS, AND CONTROL WIRING - PATCH/FIRESTOP PENETRATIONS IN FLOORS AND WALLS LEFT BY REMOVALS TO MAINTAIN FIRE RATINGS AND MATCH EXISTING ADJACENT FINISHES 11 REMOVE EXISTING PIT LADDER - PROVIDE PIT LADDER - REFER TO SHEET A-501 FOR PIT LADDER DETAIL 13 EXISTING COUNTERWEIGHT ASSEMBLY TO BE RETAINED AND RESTORED 14 REMOVE EXISTING PIT EQUIPMENT SPECIFIED FOR REPLACEMENT - PROVIDE PIT EQUIPMENT AS SPECIFIED 16 REMOVE AND REINSTALL EXISTING PIPE HANDRAIL IF REQUIRED FOR ELEVATOR EQUIPMENT ACCESS 19 REMOVE EXISTING GOVERNOR - PROVIDE GOVERNOR 20 PROVIDE ISOLATION TRANSFORMER - REFER TO SHEET A-501 FOR ELEVATOR ONE -LINE DIAGRAM 21 EXISTING WOOD WRAPPED ENTRANCE EACH SIDE TO REMAIN - PROVIDE TEMPORARY PROTECTION TO PROTECT WOOD FINISH 22 PROVIDE ELEVATOR EMERGENCY PANEL - PROVIDE FINAL CONNECTIONS TO COMPLETE SYSTEM - COORDINATE WITH E -SERIES DRAWINGS - REFER TO SHEET A-502 FOR ELEVATOR EMERGENCY PANEL DETAIL 30 REMOVE ASBESTOS CONTAINING TRANSITE BRAKE SHOE PADS FROM EXISTING ELEVATOR MACHINE - APPROXIMATELY 1 SF PER MACHINE 31 REMOVE WOOD PANELING, ASSOCIATED WOOD TRIM, MIRRORS AND ASSOCIATED "ASSUMED" ASBESTOS CONTAINING ADHESIVE FROM INTERIOR ELEVATOR CAB WALLS - APPROXIMATELY 112 SF "ASSUMED" ACM ADHESIVE TOTAL - REFERENCE SPECIFICATION SECTION 028213, FOR ADDITIONAL CAR ABATEMENT INFORMATION, DETAILS, AND PHASING REQUIREMENTS 32 HVAC EQUIPMENT - REFER TO H -SERIES DRAWINGS 34 REMOVE & SALVAGE EXISTING MOTOR GENERATOR AS SPARE PARTS - STORE FOR DURATION OF PROJECT & DISPOSE OF AT SUBSTANTIAL COMPLETION 61 RETAIN EXISTING PAINTED ENTRANCE FRAME - PREPARE AND PAINT 62 REMOVE EXISTING ELEVATOR HOISTWAY DOORS & ASSOCIATED DOOR EQUIPMENT - PROVIDE PAINTED HOISTWAY DOORS & ASSOCIATED DOOR EQUIPMENT 65 IN THE FIRST PHASE, REMOVE EXISTING MOTOR GENERATOR AND STORE IN PENTHOUSE FOR USE AS SPARE PARTS - UPON COMPLETION OF ALL PHASES, REMOVE AND DISPOSE OF 5 Architectural ResoResources 3202 1 u?r t New York 1001 1' 566 716-883.5569. and Hotel Statler Hal o � •_ 0 • 0) .N o. C E o 8 • I - (I) W Ithaca, New York 14850 Seal Bid Documents 05.18.2018 Revisions No. Description Date Construction Elevators #1 and #2 Enlarged Floor Plans A l r Job No: 564.07 Client No: Drawn by: Sheet No: A-401 D C B f A L 1 G0093 EXP Enlarged Ground Floor Plan 1/4"= 1`-0" G50 2 -•-._411111111111111111111, •-- .1 --.- LINE OF HOISTWAY BELOW UP EXISTING 3'-0" X 7'-0" ACCESS DOOR 66 D2 Enlarged Machine Room Plan 385 EXP Enlarged Typical Floor Plan (3 - 5) 1/4 = 1 '-0" B 285 EXP 352 Enlarged Second Foor Plan 1/4" = V-0" 8' - 4 1/2" V.I.F. CLEAR HOISTWAY 2 Enlarged First Floor Plan 1/4" = V-0" 1 2 10075 GYP 146D ib EXISTING 3'-0" X 7'-0" ACCESS DOOR 10039 3 8' - 1" V.I.F. CLEAR HOISTWAY Enlarged First Floor Plan 1/4" = 1 '-0" G15 Enlarged Ground Floor Plan CLEAR HOISTWAY 117 G0041 ACT 1/4" = 1 '-0" 3 4 ••_••—••_•••—••—••_•1 • • • • • • • • MACHINE ROOM 10063 EXP 20 ••i• •• •• ••4•• Enlarged Machine Room Plan 1/4" = 1'-0" EXISTING 3'-4" X 7' 0" ACCESS DOOR 8' - 6 1/8" V.I.F. 0 3'-9" V.I.F. DN r EXISTING 3'-0" x 7'-0" ACCESS DOOR 100063 EXP • LINE OF HOISTWAY BELOW ELEVATOR #3 -i N - Enlarged Mechanical Penthouse Plan 1 /4" = 1 '-0" Enlarged Typical Floor Plan (3 - 9) 1/4" = 1'-0" 215 Enlarged Second Foor Plan 1/4" = 1'-0" 5 Drawing Notes ## 1 REMOVE EXISTING GEARED HOISTING EQUIPMENT - PROVIDE GEARLESS HOISTING MACHINE AND ALL ASSOCIATED EQUIPMENT INCLUDING BUT NOT LIMITED TOO EMERGENCY BRAKE, BLOCKING BEAMS, AND DEFLECTOR SHEAVE 2 PROVIDE CAR TOP GUARD RAIL 4 EXISTING ELEVATOR SILL TO REMAIN - TYPICAL 5 EXISTING CAR AND COUNTERWEIGHT GUIDE RAILS FULL HEIGHT TO REMAIN - PREPARE AND PAINT FULL HEIGHT - TYPICAL 6 RETAIN & RESTORE EXISTING CAR FRAME & PLATFORM - REMOVE EXISTING CAR ENCLOSURE IN ITS ENTIRETY - PROVIDE CAR ENCLOSURE - REFER TO SHEET A-501 FOR CAR INTERIOR ELEVATIONS 7 REMOVE EXISTING ELEVATOR CONTROL SYSTEM - PROVIDE ELEVATOR CONTROL SYSTEM 8 REMOVE EXISTING MOTOR GENERATOR IN ITS ENTIRETY 9 APPROXIMATE LOCATION OF ELEVATOR RELATED DISCONNECTS & ELECTRICAL EQUIPMENT - COORDINATE REQUIREMENTS & CONNECTIONS WITH ELECTRICAL CONTRACTOR - REFER TO E -SERIES DRAWINGS FOR LOCATION OF EQUIPMENT 10 REMOVE EXISTING ELEVATOR EQUIPMENT NO LONGER UTILIZED AS PART OF THE MODERNIZATION IN ITS ENTIRETY - INCLUDING, BUT NOT LIMITED TO, ELECTRICAL CONDUITS, WIRE -WAYS, AND CONTROL WIRING - PATCH/FIRESTOP PENETRATIONS IN FLOORS AND WALLS LEFT BY REMOVALS TO MAINTAIN FIRE RATINGS AND MATCH EXISTING ADJACENT FINISHES 1 1 REMOVE EXISTING PIT LADDER - PROVIDE PIT LADDER - REFER TO SHEET A-501 FOR PIT LADDER DETAIL 12 REMOVE EXISTING WOOD STAIRS IN THEIR ENTIRETY 13 EXISTING COUNTERWEIGHT ASSEMBLY TO BE RETAINED AND RESTORED 14 REMOVE EXISTING PIT EQUIPMENT SPECIFIED FOR REPLACEMENT - PROVIDE PIT EQUIPMENT AS SPECIFIED 16 REMOVE AND REINSTALL EXISTING PIPE HANDRAIL IF REQUIRED FOR ELEVATOR EQUIPMENT ACCESS 17 EXISTING STAINLESS STEEL ELEVATOR HOISTWAY DOOR FRAME TO BE RETAINED AND REFINISHED 18 EXISTING STAINLESS STEEL ELEVATOR HOISTWAY DOOR TO BE RETAINED AND REFINISHED - REMOVE AND PROVIDE ASSOCIATED DOOR EQUIPMENT AS SPECIFIED 19 REMOVE EXISTING GOVERNOR - PROVIDE GOVERNOR 20 PROVIDE ISOLATION TRANSFORMER - REFER TO SHEET A-501 FOR ELEVATOR ONE -LINE DIAGRAM 23 ELECTRICAL EQUIPMENT - REFER TO E -SERIES DRAWINGS 24 EXISTING PARTIAL HEIGHT WIRE MESH PARTITION 28 REMOVE EXISTING ABANDONED ELECTRICAL DISCONNECT 30 REMOVE ASBESTOS CONTAINING TRANSITE BRAKE SHOE PADS FROM EXISTING ELEVATOR MACHINE - APPROXIMATELY 1 SF PER MACHINE 32 HVAC EQUIPMENT - REFER TO H -SERIES DRAWINGS 61 RETAIN EXISTING PAINTED ENTRANCE FRAME - PREPARE AND PAINT 63 RETAIN EXISTING ELEVATOR HOISTWAY DOORS - REMOVE AND PROVIDE ASSOCIATED DOOR EQUIPMENT AS SPECIFIED - PREPARE AND PAINT HOISTWAY DOOR PANELS 66 PROVIDE OPENING IN EXTERIOR WALL FOR EXHAUST FAN AND LOUVER - COORDINATE SIZE WITH LOUVER - REFER TO H -SERIES DRAWINGS FOR PROPELLER FAN DETAIL 4 5 Architectural ResoResources 3202 1 ut New York 1001 566 716-883-55 and Hotel Statler Hal o � •_ 0 • 0) .N o. C „ham) E o 8 • II: (I) W Ithaca, New York 14850 Seal Bid Documents 05.18.2018 Revisions No. Description Date Construction Elevators #3 and #5 Enlarged Floor Plans A l r Job No: 564.07 Client No: Drawn by: Sheet No: A-402 D C B f A L 1 1 B 60 ELEVATOR #5 2 63 61 58 64 51 EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING RUBBER BASE TO REMAIN Typical Elevation (3-5) 1/4" = 1'-0" L 60 ELEVATOR #5 EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING RUBBER BASE TO REMAIN Second Floor Elevation 1/4" = V-0" ELEVATOR #5 EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING RUBBER BASE TO REMAIN First Floor Elevation 1/4" = 1'-0" — EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED ELEVATOR #5 EXISTING TILE BASE TO REMAIN Ground Floor Elevation 1/4" = 1'-0" 2 3 Typical Elevation (3-9) 1/4" = 1'-0" EXISTING BULLETIN BOARD EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING RUBBER BASE TO REMAIN u > ELEVATOR #3 Second Floor Elevation 1/4" = F-0" > EXISTING WALL TILE TO REMAIN EXISTING TILE BASE TO REMAIN ELEVATOR #3 First Floor Elevation 1/4'' = 1 '-0" EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING RUBBER BASE TO REMAIN EXISTING WOOD HANDRAIL ELEVATOR #3 Ground Floor Elevation 1/4" = F-0" 3 EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING RUBBER BASE TO REMAIN 4 61 58 1 62 1 1 29 62 ELEVATOR # 1 Typical Elevation (3-9) 1/4" = l'-0" 2 62 61 ELEVATOR #2 58 29 62 2 4 ELEVATOR #1 ELEVATOR #2 Second Floor Elevation 1/4" = 1'-0" ELEVATOR #1 First Floor Elevation 1/4" = 1 '-0" ELEVATOR #2 EXISTING GYP/WALLPAPER SOFFIT EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING WOOD BASE TO REMAIN EXISTING GYP/WALLPAPER SOFFIT EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED EXISTING WOOD BASE TO REMAIN EXISTING WOOD PANELING TO REMAIN EXISTING WOOD BASE TO REMAIN Ground Floor Elevation EXISTING WALLPAPER TO REMAIN - PROTECT AS REQUIRED .x EXISTING WOOD BASE TO REMAIN 1/4" = 1 '-0" 4 5 Drawing Notes ## 17 EXISTING STAINLESS STEEL ELEVATOR HOISTWAY DOOR FRAME TO BE RETAINED AND REFINISHED 18 EXISTING STAINLESS STEEL ELEVATOR HOISTWAY DOOR TO BE RETAINED AND REFINISHED - REMOVE AND PROVIDE ASSOCIATED DOOR EQUIPMENT AS SPECIFIED 21 EXISTING WOOD WRAPPED ENTRANCE EACH SIDE TO REMAIN - PROVIDE TEMPORARY PROTECTION TO PROTECT WOOD FINISH 29 OWNER PROVIDED SIGNAGE TO INCLUDE CODE REQUIRED PICTOGRAPH 51 REMOVE EXISTING HALL CALL FIXTURE - PROVIDE HALL CALL STATION - REFER TO SHEET A-502 FOR HALL CALL FIXTURE DETAIL 52 REMOVE EXISTING BRAILLE SIGNAGE - OWNER TO FURNISH CODE D REQUIRED BRAILLE SIGNAGE FOR CONTRACTOR INSTALLATION ON THE INSIDE FACE OF EACH ENTRANCE JAMB 53 PROVIDE HOISTWAY ACCESS FIXTURE AND BACKBOX AT TERMINAL LANDINGS - REFER TO SHEET A-502 FOR HOISTWAY ACCESS FIXTURE DETAIL 54 REMOVE EXISTING HALL LANTERN - PROVIDE HALL LANTERN WITH POSITION INDICATOR - REFER TO SHEET A-502 FOR POSITION INDICATOR DETAIL 57 REMOVE EXISTING FIXTURE - PROVIDE COMMUNICATION FAILURE FIXTURE - REFER TO SHEET A-502 FOR COMMUNICATION FIXTURE DETAIL 58 REMOVE EXISTING HALL LANTERN - PROVIDE HALL LANTERN - REFER TO SHEET A-502 FOR HALL LANTERN DETAILS 59 OWNER TO FURNISH CODE REQUIRED ELEVATOR IDENTIFICATION SIGNAGE FOR CONTRACTOR INSTALLATION ON THE INSIDE FACE OF EACH ENTRANCE JAMB 60 REMOVE EXISTING BRAILLE SIGNAGE - PROVIDE BRAILLE SIGNAGE - TYPICAL EACH SIDE OF JAMB AT EACH ENTRANCE 61 RETAIN EXISTING PAINTED ENTRANCE FRAME - PREPARE AND PAINT 62 REMOVE EXISTING ELEVATOR HOISTWAY DOORS & ASSOCIATED DOOR EQUIPMENT - PROVIDE PAINTED HOISTWAY DOORS & ASSOCIATED DOOR EQUIPMENT 63 RETAIN EXISTING ELEVATOR HOISTWAY DOORS - REMOVE AND PROVIDE ASSOCIATED DOOR EQUIPMENT AS SPECIFIED - PREPARE AND PAINT HOISTWAY DOOR PANELS 64 TEMPORARILY REMOVE EXISTING APPLIED SIGNAGE AFFECTED BY THE SCOPE OF WORK - REINSTALL SIGNAGE AS COORDINATED WITH OWNER 67 PROVIDE ELEVATOR IDNETIFICATION SIGNAGE ON THE INSIDE FACE OF EACH ENTRANCE JAMB 5 Architec oral ResoResources 4202 New York 1001 1' 566 716-883-55 and Hotel Statler Hal o � •_ o • CP .N o. C E -10 o 0 •cc P. o I- > -0 4� c W Ithaca, New York 14850 Bid Documents 05.18.2018 Revisions No. Description Date Construction Elevators #1, #2, #3, and #5 Elevations A 1r Job No: 564.07 Client No: Drawn by: Sheet No: A-403 D B A 1 0 '10 SUPPLY 10 SUPPLY D CD T s MAC HINE RO 0 M 0 NE -LINE DIAG RAM MS AU10 MATEC TRANSFER SWIM H SIGNALS C: =VAT) R C 0 NIRO HER CD: C AB LIG HTDISC 0 NNEC TING MEANS 0: EIEVAIO R MAINLINE DISC 0 NNEC TING MEANS FA: EIRE ALARM MO DUTES M: ETEVAIO R M010 R SC: SEC URITY C AMERA SD: SEC URIIY DEVIL E ISO IATE0 N TRANSFO RMER TC EVIERG ENO Y TELE- C 0 MMUNTC A110 N F1 UIPMENTIO BE PRO VII)ED BY ETEC IRE AL C 0 NTRACIO R EX UIPMENTIO BE PRO VIDED BY ELEVAIO R C 0 NIRACIO R — 10 BE PRO VIDED UNDER SEPARATE C 0 N1RACT(N.IC ) Elevator One Line Diagram 1 3" 1' -0" 1' - 4" 2 1/ 2" X 1/2" BENT PIA1E BRAG KE1S MIN. (4) PER SIDE - PAINT- SEC UREIO MASONRY (G RO UIED SO UD) AND C 0 NC RETE WATTS WIIH 5/8" X 3" EMBEDMENT EPO XY ANC HO RS AND STEEL WITH 5/ 8" BO ITS, DO UBTE NUTTED PRO VIDE PIT SK) P SWEIC H 2" x 1/2" HATSIOCK S1EEL - PAINT ELE'VAII) R SRL ELE'VA'R) R DO 0 R FRAME FINISHED FIDORAS SPEC IIIIED ELEVATD R P1F A C C IBS LADDER 3/4" DIAMETER SOUD STEEL RUNG 1HRU SIDEBARS AND WE'D ALL ARO UND - PAINT Willi NON -SUP SURFAC ES ATIO P 0 F R -UNG - IYPIC AL PITWAIL prr FLO 0 R 2 3 6' - 6" - 0 • c_ c_ NO 1E 1. PIT IADDER SHAM BE ID C A TED 0 N IRE SAME SIDE AND WIIHIN 39" 0 F1HE HO ISTWAY 100 KING DEVIC E Pit Ladder Detail 3/4" = 1'-0" V. I F. HIO NT WAIL BARREL VAULTED C HUNG SYSTEVI — STAINLESS blEEL IRANSO M STAINLESS S1EEL REIURN CAR 0 PERA1ING PANELAS SPECIFIED CARDOORAS SPEC WED Elevators #1 & #2 Car Elevations 1/2" = 1-0" 6' - V.IF. FRO NT WALL Elevator #3 Car Elevations 1/2" = 1'-o" 6' - 9" V.IF. EQ FRO NT WA IL Elevator #5 Car Elevations 1/2" = 1'-O" SPA INIESS STEEL 'IRANSO M STANIESS STEEL RETURN CAR 0 PERA1ING PANELAS SPEC IFIED CARDOOR AS SPEC IFIED STAINIESS 'IRANSO M STAINLESS SIEEL REIURN C AR 0 PERAIING PANEL AS SPEC DIED C AR DO OR AS SPEC IFIED 2 3 SIDE WALL - 1/9" 4 5 BARREL VAULIED C HUNG SYSTEM STAINLESS S1EEL PAD STUDS PRO IEE T1VE PADS INTERLD C KING MO DUIAR WALL PANEL SYSTEM SIAINTESS SIEEL HANDRAIL zz C A RPET TEE FID 0 RING 10 MATO H EXTSIING -,- ;. 1 • • 1 e i V. IF. 1' - 3 1/4" 4 / r . P2 cl, Al 1 P2 Al 11 P2 Al P2 Al 1" IYP. P2 Al S2 (HANDRAIL PANEL) --\ P2 Al / N\ 1 53 1 , / --\-- I)' _KTYP. P2 Al 1 1 4 52 (BASE) P2 L Al Vii/ SIDE WALL - 1/9" 4 5 BARREL VAULIED C HUNG SYSTEM STAINLESS S1EEL PAD STUDS PRO IEE T1VE PADS INTERLD C KING MO DUIAR WALL PANEL SYSTEM SIAINTESS SIEEL HANDRAIL zz C A RPET TEE FID 0 RING 10 MATO H EXTSIING SIDEWAIL 5' - 5 1/ 2" 11" V. I F. 1-4 S1 , P1 -,- . , 11" V. I F. 4 / N.-- / Al -A,- -,---4 - SI 52 (BASE) iZI \4. _ i ° 0 4, S3 f 1 N\ 1 53 1 , / --\-- I)' _KTYP. , 1 S3 VII' I 1" 71 N "c•::,- 4-4 Co • Al i .14.. S3 S3 4 t SERVICE / S2 (BASE) . -7r -4, ,44-4 '7 CI SIDEWAIL 5' - 5 1/ 2" 11" V. I F. 1-4 S1 , P1 . . , P1 TYPE 4 P1 N.-- / Al P2 r P1 1" 52 (BASE) iZI DOGHOUSE STAINLESS STEEL PAD SIUDS — STAINLESS SIEEL MEFAL PAN C EYING WITH REMO VABIE PANELS F0 R D 0 G HO USE A C C FSS STAINLESS S1EEL REVEALS - 'TYPIC AL NTERLO C KING MO DUIAR WALL PANEL SYSTEM STAINLESS SEEL HANDRAIL PRO TEC TIVE PADS STAINLESS SIEEL BUMPERS DIAMOND PIATE FID 0 RING DOGHOUSE N STUNIESS SIEEL PAD STUDS STAINLESS STEEL METAL PAN C Fll ING WIIH REMO VA BLE PANELS RD R DOGHOUSEACCESS STA INIESS STEEL REV FA LS - TYPIC A L zz PRO TEC 'JIVE PADS SIDE WAIL SAINIESS S1EEL HANDRAIL INTERIO C KENG MODULAR WAIL PANEL SYSTEM DTA MO ND PIXIE FLOORING REAR WAIL Car Finish Notes HURD ING SEC ITO N ._ ., MAC BINE TYPE 4 V.LF. N.-- PITDEPIH (V. 1 F.) Al P2 . o Fl 1 1 • Al P2 \4. 350 Al P2 SI yr \ii, 11% Al P2 "c•::,- 4-4 Co --1160 Al P2 0 S3 Al P2[ S2 (HANDRAIL PANEL) SERVICE / S2 (BASE) . -7r -4, ,44-4 '7 CI L Al P2 i #5 Al P2 S2 (BASE) L_ G RO UND THRO UG H 5TH _7 N STUNIESS SIEEL PAD STUDS STAINLESS STEEL METAL PAN C Fll ING WIIH REMO VA BLE PANELS RD R DOGHOUSEACCESS STA INIESS STEEL REV FA LS - TYPIC A L zz PRO TEC 'JIVE PADS SIDE WAIL SAINIESS S1EEL HANDRAIL INTERIO C KENG MODULAR WAIL PANEL SYSTEM DTA MO ND PIXIE FLOORING REAR WAIL Car Finish Notes REAR WALL HURD ING SEC ITO N ._ ., MAC BINE TYPE 4 SPEED (FPM) N.-- PITDEPIH (V. 1 F.) '10 TAL TRAVEL (V.IF) V. IE \1/4 # 1 'MAC ITO N S 1 \4. 350 GRO UND IHRO UG H 9TH 5' - 0" SI yr \ii, 11% #2 TRAC TIO N "c•::,- 4-4 Co --1160 0 o 0 S3 0-1 # 3 V' 1 4 SERVICE / S2 (BASE) S3 L 87' - 7 1/2" \. i #5 'MAC 110 N S3 3,500 350 G RO UND THRO UG H 5TH 5' - 0" 57' - 3/4" 15' - 0" • 0, -ir b co ' E9 \r. S3 ro _I ;-1 REAR WALL REAR WAIL ELEVAIO R SC HEDIJLE HURD ING SEC ITO N ELEVAIO R NO. MAC BINE TYPE 4 SPEED (FPM) V. I F. PITDEPIH (V. 1 F.) '10 TAL TRAVEL (V.IF) CLEAR OVERHEAD (V. IF.) \1/4 # 1 'MAC ITO N S 1 2 - 6" rIOP 0 FHANDRAIL 8' - 10" 350 GRO UND IHRO UG H 9TH 5' - 0" P1 yr \ii, 11% #2 TRAC TIO N P1 3,500 350 GROUND IHRO UG H 9TET P1 87' - 7 1/ 2" 16' - 9" # 3 I SERVICE / S2 (BASE) P1 L 87' - 7 1/2" 18' - 11" i #5 'MAC 110 N SERVICE 3,500 350 REAR WAIL ELEVAIO R SC HEDIJLE HURD ING SEC ITO N ELEVAIO R NO. MAC BINE TYPE C A PA C BY (MS.) SPEED (FPM) LANDINGS PITDEPIH (V. 1 F.) '10 TAL TRAVEL (V.IF) CLEAR OVERHEAD (V. IF.) HO TEL # 1 'MAC ITO N PA SSENG ER 3,500 350 GRO UND IHRO UG H 9TH 5' - 0" 87' - 7 1/2" 16' - 9" #2 TRAC TIO N PASSENGER 3,500 350 GROUND IHRO UG H 9TET 5' - 0" 87' - 7 1/ 2" 16' - 9" # 3 'IRA C TEO N SERVICE 3,500 350 GROUND TORO UG H 91H 5' - 0" 87' - 7 1/2" 18' - 11" HALL #5 'MAC 110 N SERVICE 3,500 350 G RO UND THRO UG H 5TH 5' - 0" 57' - 3/4" 15' - 0" 4 1. FINAL C AB TNIERIO R IAYO UTAND FINISH SELEC 110 N FO R NEVA 10 RS 10 BE APPRO VED BY 0 WNER. 2. REFER '10 ELEVAIO R SPEC IFTC ATE0 NS PO R PANEL DESIG NATIO NS (A 1, P1, S1, ETC . ). 0-▪ 4 5 Architectural Resources 505 FrenMin Beffelo, New York 14202 303 Wesg 13$ Streef New Yerk, New Yerk 10014 716-883-5566 716-383-5569 7 ........ 11, 00 ES113N LiRUP and Hotel Statler Hal o 0 • 0.) .o. 71hami E 6 8 O it > -0 c u.1 0 Ithaca , New Yo Tic 14850 Bid Documents 05.18.2018 Re visio ns No. De sc rip tio n Date Construction Arc hite c tura 1 a nd Elevator Details A I r Jo b No: 564.07 Client No: Drawn by: Author She e t No: A-501 D C B f A L 1 2 1 Hall Lantern Detail PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS REUSE EXISTING BACK BOX LED ILLUMINATED ARROWS - COORDINATE UP/DOWN ARROWS WITH INTERMEDIATE AND TERMINAL LANDINGS VANDAL RESISTANT FASTENERS - TYPICAL 3" = 1'-0" 1'-8" ti > 1 V.I.F. ELF R FLETOR ELEVATOR w t=7 EVATOR E EVATO 0 OUTOEp=RVICE O 0 NORMALPOWER O 0 0 STANDBY POWER O 0 0 0 0 O 0 Cl O 0 O� O 0 0- o 6 666 'bL o IMP 4 INSIDE PANEL POSITION AND DIRECTION INDICATOR - TYPICAL OF (7) LED LAMP TO INDICATE THAT ELEVATOR IS OUT OF SERVICE - TYPICAL OF (7) LED LAMP TO INDICATE THAT ELEVATOR IS OPERATING ON NORMAL POWER - TYPICAL OF (7) LED LAMP TO INDICATE THAT ELEVATOR IS OPERATING ON STANDBY POWER - TYPICAL OF (7) PROVIDE ELEVATOR RECALL KEY SWITCH (TWO POSITION) AND FIRE HAT INDICATOR LIGHT - TYPICAL OF (6) MANUAL SELECTOR KEY SWITCH FOR ELEVATORS #1 & #2 (POSITIONS: "AUTO", "#1" "#2") LED LAMP TO INDICATE THAT DOORS ARE OPEN AT THE DESIGNATED LEVEL TWO-WAY VOICE COMMUNICATION SYSTEM WITH INSTRUCTION SIGNAGE NOTE: 1. ALL CHARACTERS SHALL BE ENGRAVED IN STAINLESS STEEL. 2. PANEL SHALL BE SURFACE MOUNTED. 3. EQUIPMENT ASSOCIATED WITH ELEVATORS #4, #8, AND #9 SHALL NOT BE MADE OPERABLE. Elevator Emergency Lobby Panel 1 1/2" = 1'-0" 1 2 6" V.I.F. TYP. OF ELEV. #1, 2, & 3 7" V.I.F. Hoistway Access Fixture VANDAL RESISTANT FASTENERS - TYPICAL ELEVATOR HOISTWAY ACCESS KEY SWITCH (POSITIONS: 'OFF", AND "UP"OR"DN") REUSE OR PROVIDE BACK BOX AS REQUIRED PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS 3" = 1'-0" TERMINAL LANDINGS m PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS ELEVATOR HALL CALL PUSH BUTTON REUSE EXISTING BACKBOX VANDAL RESISTANT FASTENERS - TYPICAL INTERMEDIATE LANDINGS Hall Call Fixtures - Elevators #1 and #2 3 ELEVATOR HALL CALL PUSH BUTTON PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS REUSE EXISTING BACKBOX VANDAL RESISTANT FASTENERS - TYPICAL 5 3/4" V.I.F. r0 O 00 0 0 0 0 0 0 o 0 0 0 Z N JO < 0 0 (� 0 E 0 0 0 0 - 00 0 ' 'olV REUSE EXISTING BACK BOX ,l PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS --- DIGITAL CAR POSITION INDICATOR LED ILLUMINATED ARROWS VANDAL RESISTANT FASTENERS - TYPICAL Position Indicator Detail 3' = 9 1 /4" TYPICAL 3 3/4" V.I.F. PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS - EXISTING BACKBOX TO BE RETAINED I LoJ ORE RECALL I707 ELEVATOR HALL CALL PUSH BUTTONS VANDAL RESISTANT FASTENERS - TYPICAL 1 —1 ELEVATOR COMMUNICATIONS FAILURE • ELEVATOR EMERGENCY POWER l o7 3 3/4" jr 3 1/4" jr V.I.F. V.I.F. 3 3/4" DESIGNATED LANDING (LOBBY) V.I.F. FIRE SERVICE INDICATOR COMMUNICATION FAILURE SPEAKER COMMUNICATION FAILURE RESET KEY SWITCH COMMUNICATION FAILURE LED INDICATOR FIRE RECALL KEY SWITCH AND IDENTIFICATION (POSITIONS: "ON", "OFF", "BYPASS") PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS EMERGENCY POWER LED INDICATOR 3" = 1'-0" 5 1/4" V.I.F. / VANDAL RESISTANT 0 d` FASTENERS - TYPICAL IN FIRE EMERGENCY, 00 NOT USE ELEVATOR. USE EXIT STARS o INTERMEDIATE LANDINGS PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS ENGRAVED PICTOGRAPH EXISTING BACKBOX TO BE RETAINED ELEVATOR HALL CALL PUSH BUTTONS 5 1/4" V.I.F. 0 IN 00 EMERGENCY, 00 NOT USF ELEVATOR. o/ USE EXIT STAIRS VANDAL RESISTANT FASTENERS - TYPICAL PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS ENGRAVED PICTOGRAPH Tom L J EXISTING BACKBOX TO BE RETAINED HALL CALL ELEVATOR PUSH BUTTON 0 TERMINAL LANDINGS Hall Call Fixtures - Elevators #3 and #5 = 1'-0" W CN 3 51/4" co N > V.I.F. TOT L ELEVATOR COMMUNICATION FAILURE • ELEVATOR EMERGENCY POWER Io 0 HU. EMERGENCY, 00 NOT USE ELEVATOR. Ir� NN JLSSALRS i L J FIRE RECALL LED EMERGENCY POWER INDICATOR EXISTING BACKBOX TO BE RETAINED COMMUNICATION FAILURE SPEAKER COMMUNICATION FAILURE LED INDICATOR COMMUNICATION FAILURE RESET KEY SWITCH 07 PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS DESIGNATED LANDING (FIRST) ENGRAVED PICTOGRAPH VANDAL RESISTANT FASTENERS - TYPICAL FIRE SERVICE INDICATOR FIRE RECALL KEY SWITCH AND INDENTIFICATION (POSITIONS: "ON", "OFF", "BYPASS") ELEVATOR HALL CALL PUSH BUTTONS EXISTING BACKBOX TO BE RETAINED 4 TT— O 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 O VANDAL RESISTANT FASTENERS - TYPICAL LED ILLUMINATED ARROWS Note: 1. PROVIDE FIXTURE IN EACH JAMB OF CENTER OPENING DOORS AND RETURN SIDE OF SIDE -SLIDE DOORS. n -Car Lantern Detail = 1'-0" 10 1/2" o o _ J L _ Capacity Car No. TYP. OF ELEV. #1, 2, & 3 7" V.I.F. i / TYP. OF ELEV. #5 TYP. OF ELEV. #1, 2, & 3 5 1 /2" V.I.F. • TYP. OF ELEV. #5 1 �'o Z\ N 1— L° I� 77 0 00 0 0 O O 0 0 O O 0 0 0 0._________ O O -,0 0 Q o 0 U o 0 O O O O ,_ oO r 1 ° K 1 Hall Lantern Detail PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS REUSE EXISTING BACK BOX LED ILLUMINATED ARROWS - COORDINATE UP/DOWN ARROWS WITH INTERMEDIATE AND TERMINAL LANDINGS VANDAL RESISTANT FASTENERS - TYPICAL 3" = 1'-0" 1'-8" ti > 1 V.I.F. ELF R FLETOR ELEVATOR w t=7 EVATOR E EVATO 0 OUTOEp=RVICE O 0 NORMALPOWER O 0 0 STANDBY POWER O 0 0 0 0 O 0 Cl O 0 O� O 0 0- o 6 666 'bL o IMP 4 INSIDE PANEL POSITION AND DIRECTION INDICATOR - TYPICAL OF (7) LED LAMP TO INDICATE THAT ELEVATOR IS OUT OF SERVICE - TYPICAL OF (7) LED LAMP TO INDICATE THAT ELEVATOR IS OPERATING ON NORMAL POWER - TYPICAL OF (7) LED LAMP TO INDICATE THAT ELEVATOR IS OPERATING ON STANDBY POWER - TYPICAL OF (7) PROVIDE ELEVATOR RECALL KEY SWITCH (TWO POSITION) AND FIRE HAT INDICATOR LIGHT - TYPICAL OF (6) MANUAL SELECTOR KEY SWITCH FOR ELEVATORS #1 & #2 (POSITIONS: "AUTO", "#1" "#2") LED LAMP TO INDICATE THAT DOORS ARE OPEN AT THE DESIGNATED LEVEL TWO-WAY VOICE COMMUNICATION SYSTEM WITH INSTRUCTION SIGNAGE NOTE: 1. ALL CHARACTERS SHALL BE ENGRAVED IN STAINLESS STEEL. 2. PANEL SHALL BE SURFACE MOUNTED. 3. EQUIPMENT ASSOCIATED WITH ELEVATORS #4, #8, AND #9 SHALL NOT BE MADE OPERABLE. Elevator Emergency Lobby Panel 1 1/2" = 1'-0" 1 2 6" V.I.F. TYP. OF ELEV. #1, 2, & 3 7" V.I.F. Hoistway Access Fixture VANDAL RESISTANT FASTENERS - TYPICAL ELEVATOR HOISTWAY ACCESS KEY SWITCH (POSITIONS: 'OFF", AND "UP"OR"DN") REUSE OR PROVIDE BACK BOX AS REQUIRED PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS 3" = 1'-0" TERMINAL LANDINGS m PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS ELEVATOR HALL CALL PUSH BUTTON REUSE EXISTING BACKBOX VANDAL RESISTANT FASTENERS - TYPICAL INTERMEDIATE LANDINGS Hall Call Fixtures - Elevators #1 and #2 3 ELEVATOR HALL CALL PUSH BUTTON PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS REUSE EXISTING BACKBOX VANDAL RESISTANT FASTENERS - TYPICAL 5 3/4" V.I.F. r0 O 00 0 0 0 0 0 0 o 0 0 0 Z N JO < 0 0 (� 0 E 0 0 0 0 - 00 0 ' 'olV REUSE EXISTING BACK BOX ,l PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS --- DIGITAL CAR POSITION INDICATOR LED ILLUMINATED ARROWS VANDAL RESISTANT FASTENERS - TYPICAL Position Indicator Detail 3' = 9 1 /4" TYPICAL 3 3/4" V.I.F. PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS - EXISTING BACKBOX TO BE RETAINED I LoJ ORE RECALL I707 ELEVATOR HALL CALL PUSH BUTTONS VANDAL RESISTANT FASTENERS - TYPICAL 1 —1 ELEVATOR COMMUNICATIONS FAILURE • ELEVATOR EMERGENCY POWER l o7 3 3/4" jr 3 1/4" jr V.I.F. V.I.F. 3 3/4" DESIGNATED LANDING (LOBBY) V.I.F. FIRE SERVICE INDICATOR COMMUNICATION FAILURE SPEAKER COMMUNICATION FAILURE RESET KEY SWITCH COMMUNICATION FAILURE LED INDICATOR FIRE RECALL KEY SWITCH AND IDENTIFICATION (POSITIONS: "ON", "OFF", "BYPASS") PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS EMERGENCY POWER LED INDICATOR 3" = 1'-0" 5 1/4" V.I.F. / VANDAL RESISTANT 0 d` FASTENERS - TYPICAL IN FIRE EMERGENCY, 00 NOT USE ELEVATOR. USE EXIT STARS o INTERMEDIATE LANDINGS PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS ENGRAVED PICTOGRAPH EXISTING BACKBOX TO BE RETAINED ELEVATOR HALL CALL PUSH BUTTONS 5 1/4" V.I.F. 0 IN 00 EMERGENCY, 00 NOT USF ELEVATOR. o/ USE EXIT STAIRS VANDAL RESISTANT FASTENERS - TYPICAL PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS ENGRAVED PICTOGRAPH Tom L J EXISTING BACKBOX TO BE RETAINED HALL CALL ELEVATOR PUSH BUTTON 0 TERMINAL LANDINGS Hall Call Fixtures - Elevators #3 and #5 = 1'-0" W CN 3 51/4" co N > V.I.F. TOT L ELEVATOR COMMUNICATION FAILURE • ELEVATOR EMERGENCY POWER Io 0 HU. EMERGENCY, 00 NOT USE ELEVATOR. Ir� NN JLSSALRS i L J FIRE RECALL LED EMERGENCY POWER INDICATOR EXISTING BACKBOX TO BE RETAINED COMMUNICATION FAILURE SPEAKER COMMUNICATION FAILURE LED INDICATOR COMMUNICATION FAILURE RESET KEY SWITCH 07 PROVIDE OVERSIZED STAINLESS STEEL PLATE TO COVER ALL VOIDS DESIGNATED LANDING (FIRST) ENGRAVED PICTOGRAPH VANDAL RESISTANT FASTENERS - TYPICAL FIRE SERVICE INDICATOR FIRE RECALL KEY SWITCH AND INDENTIFICATION (POSITIONS: "ON", "OFF", "BYPASS") ELEVATOR HALL CALL PUSH BUTTONS EXISTING BACKBOX TO BE RETAINED 4 TT— O 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 O VANDAL RESISTANT FASTENERS - TYPICAL LED ILLUMINATED ARROWS Note: 1. PROVIDE FIXTURE IN EACH JAMB OF CENTER OPENING DOORS AND RETURN SIDE OF SIDE -SLIDE DOORS. n -Car Lantern Detail = 1'-0" 10 1/2" MAIN OPERATING PANEL Car Operator Panel VITAL CAR )SITION INDICATOR TH DIRECTIONAL ROW EPHONE SPEAKER CROPHONE EFIGHTERS OPERATION BINET - PHASE II NAGE ENGRAVED ON CK OF COVER Y LOCK E SERVICE INDICATOR NDAL RESISTANT STENERS - TYPICAL OVIDE STAINLESS EL FIXTURE PLATE CTILE CHARACTERS / NTIFICATION TAGS - 'ICAL R CALL BUTTONS - )ORDINATE WITH MBER OF LANDINGS �R CALL BRAILLE GES FOR LANDINGS LOW THE MAIN ENTRY DOR SHALL INDICATE -2, -3 ETC... AS QUIRED BY CODE EMERGENCY STOP KEYSWITCH (POSITIONS: "RUN", "STOP") 5 General Elevator Notes A. CONTRACTOR SHALL COORDINATE WORK BETWEEN ALL TRADES PRIOR TO STARTING CONSTRUCTION TO UNDERSTAND FULL EXTENT OF WORK. B. WORK IS TO BE PERFORMED IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS AND AGENCIES HAVING JURISDICTION. C. DIMENSIONS ARE TO THE FINISH FACE OF SURFACES UNLESS NOTED OTHERWISE. THE CONTRACTOR IS NOT TO SCALE THE DRAWINGS OR DETAILS AND IS RESPONSIBLE FOR VERIFYING EXISTING CONDITIONS AND DIMENSIONS. WHERE DIMENSIONAL DISCREPANCIES ARISE, REVIEW FIELD CONDITIONS WITH ARCHITECT BEFORE PROCEEDING WITH WORK OR ORDERING MATERIAL. D. THE CONTRACTOR SHALL PERFORM ANY CUTTING, PATCHING, AND REPAIRING AS REQUIRED TO PERFORM THE WORK INDICATED WITHIN THE DRAWINGS. E. DETAILS, SECTIONS, AND MATERIALS SHOWN AND/OR NOTED ON DRAWINGS SHALL APPLY TO OTHER SIMILAR LOCATIONS UNLESS NOTED OTHERWISE. F. FIRESTOP AND SEAL PENETRATIONS THROUGH NEW AND EXISTING RATED CONSTRUCTION. NOTIFY DIRECTOR'S REPRESENTATIVE WHERE MISCELLANEOUS UNPROTECTED/UNSEALED PENETRATIONS HAVE OCCURRED AT RATED CONSTRUCTION. G. ASBESTOS CONTAINING MATERIALS (ACM) AND LEAD BASED PAINT, (LBP) MAY BE PRESENT WITHIN THIS PROJECT SITE. ANY QUESTIONABLE REPRESENTATIVE FOR AN ACCURATE INTERPRETATION AND OR SAMPLING AND ANALYSIS. ALL CONTRACTORS ARE RESPONSIBLE FOR MAKING THEMSELVES AND THEIR EMPLOYEES AWARE OF THE PRESENCE, LOCATION AND QUANTITY OF EXISTING ACM, AND TO WARN THEIR EMPLOYEES OF THE POTENTIAL DANGER OF EXPOSURE TO ASBESTOS. ANY DISTURBANCE OF ACM MUST BE PERFORMED BY A LICENSED ASBESTOS ABATEMENT CONTRACTOR EMPLOYING CERTIFIED WORKERS. SEE SURVEY "RENOVATION SURVEY FOR ASBESTOS CONTAINING MATERIALS, LEAD BASED PAINT AND PCB'S" DATED APRIL 18, 2017, AMENDED SEPTEMBER 1, 2017 WITHIN THE SPECIFICATIONS. H. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT SHALL APPLY. I. TEMPORARY FIRE EXTINGUISHERS TO BE PROVIDED AND MAINTAINED PER NYS FIRE CODE SECTION 906. EXISTING EGRESS SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES. J. ELEVATOR FIXTURE DETAILS ARE SCHEMATIC AND ARE INTENDED TO DEFINE THE GENERAL DESIGN INTENT AND FUNCTIONS OF THE ELEVATOR SYSTEM. ACTUAL SIZE AND LAYOUT OF ALL FIXTURES SHALL BE VERIFIED WITH THE APPROVED MANUFACTURER AND EXISTING FIELD CONDITIONS. ALL FIXTURES SHALL BE APPROVED BY ARCHITECT PRIOR TO ODERING AND INSTALLATION. ALL VERBIAGE SHALL BE ENGRAVED IN THE FACEPLATE OF EACH RESPECTIVE FIXTURE UNLESS OTHERWISE NOTED. K. PAINTED SURFACES SHALL BE TREATED AS LEAD BASED POINT. WHEN DRILLING OVERHEAD, USE A CONE DEVICE WITH A NEPA VACUUM ATTACHED TO COLLECT ALL PARTICLES. L. ALL FIXTURES SHALL USE VANDAL RESISTANT FASTENERS UNLESS OTHERWISE NOTED. M. REFER TO A -SERIES DRAWINGS FOR OVERALL BUILDING FLOOR PLANS. INSTALL SECURITY DEVICE AS FURNISHED BY ELECTRICAL CONTRACTOR - ELEVATORS #1 AND #2 ONLY LOCKABLE SERVICE CABINET - REFER TO SPECIFICATIONS FOR ELEVATOR SPECIFIC FUNCTIONS 3" = 1'-0" 4 5 Architec oral ResoResources 3202 New York 1001 566 716-883.6569. and Hotel Statler Hal Ithaca, New York 14850 Seal Bid Documents 05.18.2018 Revisions No. Description Date Construction Architectural and Elevator Details A 1 r Job No: 564.07 Client No: Drawn by: Sheet No: Author A-502 o o _ J L _ Capacity Car No. DI( PC WI AF g/ r , TEI 0p00 0 0°0 0 0 0 0 0 0 0 000 0 00 0 00 r_ MI FIREFIGHTERS OPERATION r7/ Cf SIC BA KE FIF o� r J 1 -0,7.. -----FA L_ VF PR STI TA IDI E 8 0) C ii ii ) TY 6 �(�)J fiii iii % Cf Ci NL 4. HE 0 -I '::i iii ® C/ TA o no- II %ii.kHifi: BE FU -1, EiiBB ar �� 000R >1.< DOoo OPEN iiii ii ii ii CLOSE RE PUSH TO rift ALARM HELP _ 4151,, I \ ALL RUN O) STOP ii ii.ii � 0 _J SERVICE CABINET o L_ u: to co ° o 1 _ MAIN OPERATING PANEL Car Operator Panel VITAL CAR )SITION INDICATOR TH DIRECTIONAL ROW EPHONE SPEAKER CROPHONE EFIGHTERS OPERATION BINET - PHASE II NAGE ENGRAVED ON CK OF COVER Y LOCK E SERVICE INDICATOR NDAL RESISTANT STENERS - TYPICAL OVIDE STAINLESS EL FIXTURE PLATE CTILE CHARACTERS / NTIFICATION TAGS - 'ICAL R CALL BUTTONS - )ORDINATE WITH MBER OF LANDINGS �R CALL BRAILLE GES FOR LANDINGS LOW THE MAIN ENTRY DOR SHALL INDICATE -2, -3 ETC... AS QUIRED BY CODE EMERGENCY STOP KEYSWITCH (POSITIONS: "RUN", "STOP") 5 General Elevator Notes A. CONTRACTOR SHALL COORDINATE WORK BETWEEN ALL TRADES PRIOR TO STARTING CONSTRUCTION TO UNDERSTAND FULL EXTENT OF WORK. B. WORK IS TO BE PERFORMED IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS AND AGENCIES HAVING JURISDICTION. C. DIMENSIONS ARE TO THE FINISH FACE OF SURFACES UNLESS NOTED OTHERWISE. THE CONTRACTOR IS NOT TO SCALE THE DRAWINGS OR DETAILS AND IS RESPONSIBLE FOR VERIFYING EXISTING CONDITIONS AND DIMENSIONS. WHERE DIMENSIONAL DISCREPANCIES ARISE, REVIEW FIELD CONDITIONS WITH ARCHITECT BEFORE PROCEEDING WITH WORK OR ORDERING MATERIAL. D. THE CONTRACTOR SHALL PERFORM ANY CUTTING, PATCHING, AND REPAIRING AS REQUIRED TO PERFORM THE WORK INDICATED WITHIN THE DRAWINGS. E. DETAILS, SECTIONS, AND MATERIALS SHOWN AND/OR NOTED ON DRAWINGS SHALL APPLY TO OTHER SIMILAR LOCATIONS UNLESS NOTED OTHERWISE. F. FIRESTOP AND SEAL PENETRATIONS THROUGH NEW AND EXISTING RATED CONSTRUCTION. NOTIFY DIRECTOR'S REPRESENTATIVE WHERE MISCELLANEOUS UNPROTECTED/UNSEALED PENETRATIONS HAVE OCCURRED AT RATED CONSTRUCTION. G. ASBESTOS CONTAINING MATERIALS (ACM) AND LEAD BASED PAINT, (LBP) MAY BE PRESENT WITHIN THIS PROJECT SITE. ANY QUESTIONABLE REPRESENTATIVE FOR AN ACCURATE INTERPRETATION AND OR SAMPLING AND ANALYSIS. ALL CONTRACTORS ARE RESPONSIBLE FOR MAKING THEMSELVES AND THEIR EMPLOYEES AWARE OF THE PRESENCE, LOCATION AND QUANTITY OF EXISTING ACM, AND TO WARN THEIR EMPLOYEES OF THE POTENTIAL DANGER OF EXPOSURE TO ASBESTOS. ANY DISTURBANCE OF ACM MUST BE PERFORMED BY A LICENSED ASBESTOS ABATEMENT CONTRACTOR EMPLOYING CERTIFIED WORKERS. SEE SURVEY "RENOVATION SURVEY FOR ASBESTOS CONTAINING MATERIALS, LEAD BASED PAINT AND PCB'S" DATED APRIL 18, 2017, AMENDED SEPTEMBER 1, 2017 WITHIN THE SPECIFICATIONS. H. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT SHALL APPLY. I. TEMPORARY FIRE EXTINGUISHERS TO BE PROVIDED AND MAINTAINED PER NYS FIRE CODE SECTION 906. EXISTING EGRESS SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES. J. ELEVATOR FIXTURE DETAILS ARE SCHEMATIC AND ARE INTENDED TO DEFINE THE GENERAL DESIGN INTENT AND FUNCTIONS OF THE ELEVATOR SYSTEM. ACTUAL SIZE AND LAYOUT OF ALL FIXTURES SHALL BE VERIFIED WITH THE APPROVED MANUFACTURER AND EXISTING FIELD CONDITIONS. ALL FIXTURES SHALL BE APPROVED BY ARCHITECT PRIOR TO ODERING AND INSTALLATION. ALL VERBIAGE SHALL BE ENGRAVED IN THE FACEPLATE OF EACH RESPECTIVE FIXTURE UNLESS OTHERWISE NOTED. K. PAINTED SURFACES SHALL BE TREATED AS LEAD BASED POINT. WHEN DRILLING OVERHEAD, USE A CONE DEVICE WITH A NEPA VACUUM ATTACHED TO COLLECT ALL PARTICLES. L. ALL FIXTURES SHALL USE VANDAL RESISTANT FASTENERS UNLESS OTHERWISE NOTED. M. REFER TO A -SERIES DRAWINGS FOR OVERALL BUILDING FLOOR PLANS. INSTALL SECURITY DEVICE AS FURNISHED BY ELECTRICAL CONTRACTOR - ELEVATORS #1 AND #2 ONLY LOCKABLE SERVICE CABINET - REFER TO SPECIFICATIONS FOR ELEVATOR SPECIFIC FUNCTIONS 3" = 1'-0" 4 5 Architec oral ResoResources 3202 New York 1001 566 716-883.6569. and Hotel Statler Hal Ithaca, New York 14850 Seal Bid Documents 05.18.2018 Revisions No. Description Date Construction Architectural and Elevator Details A 1 r Job No: 564.07 Client No: Drawn by: Sheet No: Author A-502 1 D -r-7 C B A EXISTING 20"x18" DOOR LOUVER 1 1 1 1 1 1 / 1 1 v X r\ 11 / 1 1 1 1 1 1 1 1 r 1 1 1 1 1 1 11 x r\ / 1 / 1 / 1 1 1 1 1 f 1 1 1 1 1 1 1 11 x 11 1 1 / 1 1 1 1 1 1 1 66x08 DN EXISTING ELECTRIC UNIT HEATER AND THERMOSTAT TO REMAIN MACHINE ROOM 10064 EXP 66x08 DN EXISTING BACKDRAFT DAMPER TO REMAIN. /ri 32"x16" DUCT WITH GOOSENECK AND SCREEN LINE OF HOISTWAYS BELOW I I 1 1 IJ n 111 - Enlarged fb Enlarged Machine Room Plan (Elevators 1-2) 1/4' = 1 -0" ELEVATOR #2 EXISTING 35"x30" LOUVER LOW AT ROOF ELEVATOR #1 EXISTING 35"x30"LOUVER LOW AT ROOF Enlarged Top Of Hoistway Plan (Elevators 1-2) 1/4" = 1'-0" 1 36"x18" LOUVER BOL 10" AFF. 48"x17" LOUVER BOL 48" AFF. - r 2 3 4 5 30"xl 8" LOUVER BOL 23" AFF DN EXISTING ELECTRIC UNIT HEATER AND THERMOSTAT TO REMAIN MACHINE ROOM 10063 EXP 36"X18" LOUVER EXISTING BACKDRAFT BOL 23" AFF DAMPER TO REMAIN. r 35"X18" LOUVER BELOW AT TOP OF HOISTWAY Enlarged Machine Room Plan (Elevator 3) 1/4' = 1'-0' 24 LA - r /i 1 36"X16" LOUVER WI /II BOL 52" AFF MACHINE ROOM 60067 EXP UP CD3 Enlarged Floor Plan (Elevator 5) 1 1/4,�_ �,A�. /4" = 1 '-0" 25 T EXISTING 35"X23" LOUVER 24 AND CONTROL DAMPER L ELEVATOR #5 EXISTING 35"X23" LOUVER AND CONTROL DAMPER Enlarged Roof and Penthouse Plan(Elevator 5) 1/4" = GENERAL NOTES: 1 CONTRACTOR SHALL FIELD VERIFY EXISTING LOUVER DIMENSIONS AND LOCATIONS. REMOVAL NOTES: 1 2 3 4 REMOVE EXISTING FAN, ACCESSORIES, AND ASSOCIATED PNEUMATIC CONTROLS. REMOVE AND SALVAGE TWO (2) EXISTING FANS AND CONTROLS AND TURN OVER TO OWNER. REMOVE AND STORE ASSOCIATED DUCTWORK FOR REINSTALLATION. EXISTING LOUVER AND BACKDRAFT DAMPER TO REMAIN. REMOVE EXISTING PLYWOOD BLANK OFF PANEL. REMOVE AND SALVAGE TWO (2) EXISTING FANS AND TURN OVER TO OWNER. REMOVE ASSOCIATED DUCTWORK, BACKDRAFT DAMPER, AND CONTROLS AND WIRING BACK TO SOURCE. EXISTING LOUVER TO REMAIN. 2 3 4 5 tom W w :1 a o 6 O) .N L 2E O p 0 0 W � O A c GO) ILJ Ithaca, New York 14854 BID DOCUMENTS 05.18.2018 Revisions HVAC Elevators #1, #2, #3, and #5 Enlarged Floor Removal Plans A ( r Job No: 564.07 Client No: Drawn by: TJE Sheet No: H-401 B D C B EXISTING 20"x18"1 DOOR LOUVER t 66x1 DN (E) EXISTING ELECTRIC UNIT HEATER. 66x18 DN (E) 66x18 DN (E) 3/8" LIQUID & 5/8" GAS REFRIGERANT PIPING EF -24 (TYP. 2) MACHINE ROOM 10064 EXP EXISTING BACKDRAFT DAMPER. MOUNT HIGH ON WALL 7 LINE OF HOISTWAYS BELOW 1l AC -1 AC -1 Enlarged Machine Room Plan (Elevators 1-2) 1 /4" =1 -0' ELEVATOR #2 d EXISTING 35"x30" LOUVER AT TOP OF HOISTWAY ELEVATOR #1 EXISTING 35"x30" LOUVER AT TOP OF HOISTWAY Enlarged Top Of Hoistway Plan (Elevators 1-2) 1 /4" = 1'-0" 36"x18" LOUVER BOL 10" AFF. 3/4" CONDENSATE DRAIN THROUGH WALL TO BUILDING EXTERIOR 48"xl 7" LOUVER BOL 48" AFF. 30"x18" LOUVER BOL 23" AFF 610 00 DN EXISTING ELECTRIC UNIT HEATER EF -24 (TYP. 2)—\ Q MACHINE ROOM 10063 EXP EXISTING BACKDRAFT DAMPER 0 36"X18" LOUVER BOL 23" AFF 35"X18" LOUVER AT TOP OF HOISTWAY BELOW Enlarged Machine Room Plan (Elevator 3) 1 /4' = MACHINE ROOM 60067 EXP ©O EXISTING 36"X18" LOUVER BOL 52" AFF UP EF -24A CD3 Enlarged Floor Plan (Elevator 5) 1/4"_ �,A�. = 1 '-0" 25 WEATHER HOOD GRAVITY BACKDRAFT DAMPER EXISTING 35"X23" LOUVER AND (2:4) CONTROL DAMPER ELEVATOR #5 EXISTING 35"X23" LOUVER AND CONTROL DAMPER Enlarged Roof and Penthouse Plan(Elevator 5) 1/4" = 1.-0' GENERAL NOTES: 1 CONTRACTOR SHALL FIELD VERIFY EXISTING LOUVER DIMENSIONS AND LOCATIONS AND COORDINATE WITH REQUIRED CONTROL DAMPER SIZING. KEY NOTES: CLEAN EXISTING DUCTWORK AND BACKDRAFT DAMPER PRIOR TO REINSTALLATION. INSTALL NEW EXHAUST FANS WITHIN EXISTING DUCTWORK AND RECONNECT TO EXISTING ELECTRICAL AND TEMPERATURE CONTROLS. REFER TO SCHEDULE, H-500 FOR FAN DETAILS. PROVIDE SHEET METAL BLANK OFF PANEL FOR EXISTING DOOR LOUVER. ANCHOR THROUGH EXISTING LOUVER MOUNTING HOLES. DO NOT DRILL NEW HOLES INTO EXISTING DOOR STRUCTURE. PROVIDE ELECTRONIC CONTROL DAMPER IN SHEET METAL WALL SLEEVE. CONTROL DAMPER SHALL POWER OPEN UPON EXHAUST FAN ACTIVATION. WIRE TO EXISTING FAN CIRCUIT. PROVIDE CONTROL DAMPER IN 16 GA GALVANIZED SHEET METAL WALL SLEEVE. CONTROL DAMPER SHALL BE GREENHECK MODEL: VCD-23, GALVANIZED, WITH BELIMO ACTUATOR, MODEL: AFBUP. ACTUATOR SHALL BE 120 VAC, 2 -POSITION, SPRING RETURN, NORMALLY CLOSED. COORDINATE ACTUATOR CONNECTION AND CONTROL TO FIRE PROTECTION PANEL TO POWER OPEN UPON DETECTION OF SMOKE. CONTROL DAMPER SHALL BE 12 INCHES SMALLER IN WIDTH THAN LOUVER OPENING FOR SIDE MOUNTING OF DAMPER ACTUATION. NO PART OF CONTROL DAMPER OR ACTUATOR SHALL EXTEND INTO THE ELEVATOR SHAFT. PROVIDE WALL PENETRATION ABOVE DOOR FOR FAN INSTALLATION. (6) PROVIDE TOP ACCESS FILTER HOUSING TO MATCH THE SIZE OF THE EXISTING INTAKE WITH 2" PLEATED MERV 8 FILTERS AND REMOVABLE ACCESS PANEL WITH GASKET SEAL FOR FILTER REPLACEMENT. SUPPORT UNIT FROM VERTICAL STAIR FRAMING USING MANUFACTURERS WALL MOUNT BRACKET. D -4 C A A 1 2 3 4 5 er Hall and Hotel witiz Ithaca, New York 14850 BID DOCUMENTS 05.18.2018 Revisions HVAC Elevators #1, #2, #3, and #5 Enlarged Floor Plans A I r Job No: 564.07 Client No: Drawn by: TJE Sheet No: H-402 B D C A MECHANICAL SYMBOL LIST A 12/8 12/8 k y 140 24/12 t DUCT (FIRST FIGURE, SIDE SHOWN, DIMENSIONS IN INCHES) SINGLE LINE DUCT (FIRST FIGURE, SIDE SHOWN, DIMENSIONS IN INCHES) DUCT SECTION - SUPPLY DUCT SECTION - RETURN DUCT SECTION -EXHAUST 14" ROUND DUCT 24" x 12" FLAT OVAL DUCT VOLUME DAMPER - MANUAL OPERATION VOLUME DAMPER - MANUAL OPERATION TURNING VANES ACOUSTICAL TURNING VANES RISE IN DIRECTION OF ARROW — - D I IL DROP IN DIRECTION OF ARROW AD IL 12/8 FIRE DAMPER ACCESS DOOR TO BE LOCATED ON MOST ACCESSIBLE SIDE OF DUCT –4 VERTICAL BLADE POSITION –. HORIZONTAL BLADE POSITION SMOKE DAMPER ACCESS DOOR TO BE LOCATED ON MOST ACCESSIBLE SIDE OF DUCT COMBINATION FIRE / SMOKE DAMPER ACCESS DOOR TO BE LOCATED ON MOST ACCESSIBLE SIDE OF DUCT LINED DUCT (DIM. IS INTERNAL) FLEXIBLE DUCT FLEXIBLE CONNECTION QT THERMOSTAT [�T PNEUMATIC THERMOSTAT 12 — L—�—+-- - UC SENSOR HUMIDISTAT CO2 SENSOR REGISTER OR GRILLE - TOP NUMBER REPRESENTS TAG, SEE SCHEDULE; BOTTOM NUMBER REPRESENTS CFM. DIFFUSER - LETTER REPRESENTS TAG, SEE SCHEDULE; NUMBER REPRESENTS CFM. KEY NOTE ROOM NUMBER SUPPLY AIR RETURN OR EXHAUST AIR LOUVERED DOOR UNDERCUT DOOR GENERAL NOTES A. DO NOT SHUT DOWN ANY MECHANICAL, PLUMBING, FIRE PROTECTION, NATURAL GAS, ELECTRICAL, OR RELATED SYSTEMS WITHOUT BUILDING OWNER'S PRIOR WRITTEN APPROVAL. FOLLOW ALL OWNER REQUIREMENTS AND SHUT DOWN PROCEDURES AS WELL AS ALL REQUIREMENTS OF THS PROJECT. B. IF REQUIRED, PROVIDE SHUT DOWNS AND TIE-INS DURING OFF HOURS TO AVOID DISRUPTION OF BUILDING SYSTEMS. COORDINATE ALL SHUT DOWN REQUIREMENTS PRIOR TO SUBMITTING BID (INCLUDE ALL SHUT DOWNS REQUIRED DURING OFF HOURS IN BID). C. PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. OBTAIN ALL REQUIRED PERMITS. D. PROVIDE ALL REQUIRED EXCAVATION, BACKFILL AND COMPACTION FOR ALL UNDERGROUND WORK. E. FIELD VERIFY EXACT LOCATION, DEPTH, COMPOSITION AND CONDITION OF ALL PIPING, VALVES AND SYSTEMS AS REQUIRED FOR WORK OF THE CONTRACT. F. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS AND DECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITH OWNER AND GENERAL CONTRACTOR AND ALL TRADES. G. REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECT SPECIFICATIONS FOR ANY PROJECT PHASING REQUIREMENTS. H. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF FLASHING TO CURBS, ROOF PENETRATIONS AND SUPPORTS. GENERAL MECHANICAL NOTES 1.) THE ENTIRE MECHANICAL SYSTEM SHALL BE IN ACCORDANCE WITH THE THE 2015 INTERNATIONAL MECHANICAL CODE AND LOCAL INSPECTOR 2.) THE CONTRACTOR SHALL OBTAIN AND PAY ALL FEES RELATED TO PERMITTING, INSPECTIONS, TAP -ON FEES, ETC. 3.) CONTRACTOR SHALL COORDINATE ANY MECHANICAL, PLUMBING OR PIPING SYSTEM SHUTDOWN WITH THE OWNER 48 HOURS IN ADVANCE. 4.) ALL WORK SHALL BE COORDINATED WITH THE EQUIPMENT VENDORS. 5.) ALL MECHANICAL SYSTEMS SHALL BE SUPPORTED AS REQUIRED BY THE STATE LOCAL CODE REQUIREMENTS AND PER MANUFACTURER'S RECOMMENDATIONS. 6.) THE MECHANICAL SYSTEM(S) SHALL BE TESTED AS REQUIRED BY STATE AND LOCAL CODE OR BY THE REQUIREMENTS OF THE LOCAL INSPECTOR. 2 HVAC ABBREVIATIONS AC ACU(S) ADJ AF AFF AFG AHU ALT AMB AMP ANSI APD APPROX AVG AFUE BHP BLDG BO BSMT BTU CAP CFM CLG CLR CMPR COL CONN COMB CONC GOND CONT CHWR CHWS CU IN CU FT CV DB db DC DEG DEMO DIA DWG E EAT EC EDR ELEV ENGR EQ ESP EST ETR EVAP EWT EX EXIST EXP EXT F FA FIN FL FLA FPC FPM FPS FT FUT FV G GA GAL GC GPM GPD GPH GR HC HD HG HORIZ HP HPS HWR HWS HR HVAC HZ ID IN INSUL INT IPS PERCENT ALTERNATING CURRENT AIR CONDITIONING UNIT(S) ADJACENT AIR FOIL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALTERNATE AMBIENT AMPERE (AMP, AMPS) AMERICAN NATIONAL STANDARD INSTITUTE AIR PRESSURE DROP APPROXIMATE (LY) AVERAGE ANNUAL FUEL UTILIZATION BRAKE HORSE POWER BUILDING BOTTOM OF BASEMENT BRITISH THERMAL UNIT CAPACITY CUBIC FEET PER MINUTE CEILING CLEAR COMPRESSOR COLUMN CONNECTION COMBUSTION CONCRETE CONDES (-ER,-ING,-ATION,ATE) CONTINUOUS CHILLED WATER RETURN CHILLED WATER SUPPLY CUBIC INCH CUBIC FEET VALVE FLOW COEFFICIENT DECIBEL DRY BULB DIRECT CURRENT DEGREE DEMOLITION DIAMETER DRAWING PREFIX FOR EXISTING ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR EQUIVALENT DIRECT RADIATION ELEVATION ENGINEER EQUAL EXTERNAL STATIC PRESSURE ESTIMATED EXISTING TO REMAIN EVAPTORAT (-E,-ING,-ED,-OR) ENTERING WATER TEMPERATURE EXISTING EXISTING EXPANSION EXTERIOR FAHRENHEIT FREE AREA FINISHED FLOOR FULL LOAD AMPS FIRE PROTECTION CONTRACTOR FEET PER MINUTE FEET PER SECOND FOOT OR FEET FUTURE FACE VELOCITY GLYCOL GAGE OR GAUGE GALLONS GENERAL CONTRACTOR GALLONS PER MINUTE GALLONS PER DAY GALLONS PER HOUR GRAINS HVAC CONTRACTOR HEAD MERCURY HORIZONTAL HORSEPOWER HIGH PRESSURE STEAM HEATING WATER RETURN HEATING WATER SUPPLY HOUR HEATING, VENTILATION AND AIR CONDITIONING FREQUENCY DIAMETER, INSIDE INCH INSULATION INTERIOR IRON PIPE SIZE KW KILOWATT KWH KILOWATT HOUR LAT LBS LF LEAVING AIR TEMPERATURE POUNDS LINEAR FEET LG LIN FT LOC LPS LRA LWT MATL MAX MBH MCA MECH MFG MIN MISC MOCP MPS MTG N/A NC NC NIC NO NO NTS OC OA OD OPP OZ ODWS OPG OS OT PC PLBG PH PPM PR PRESS PSF PSI PSIG R R12,R22 RA RAD RCVR RECIRC RH REF RLA RO ROW RPM SA SEER SCFM SIM SP SPEC SPLY SQ SQ FT SQ IN ST STD SUCT T' STAT TA TBD TC TD TEMP TO TSP TYP LENGTH LINEAL FOOT OR FEET LOCATION LOW PRESSURE STEAM LOCKED ROTOR AMPS LEAVING WATER TEMPERATURE MATERIAL MAXIMUM BTU PER HOUR (THOUSAND) MINIMUM CIRCUIT AMPS. MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MAXIMUM OVERCURRENT PROTECTION MEDIUM PRESSURE STEAM MOUNTING NOT APPLICABLE NOISE CRITERIA NORMALLY CLOSED NOT IN CONTRACT NUMBER NORMALLY OPEN NOT TO SCALE ON CENTER OUTSIDE AIR DIAMETER, OUTSIDE OPPOSITE HAND OUNCE ON DEMAND WATER HEATER OPENING OPEN SITE OFF TOP PLUMBING CONTRACTOR PLUMBING PHASE (ELECTRICAL) PARTS PER MILLION PAIR PRESSURE POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PSI GAUGE THERMAL RESISTANCE REFRIGERANT (12,22,ETC) RETURN AIR RADIATION RECEIVER REFRIGERANT (12,22,ETC) RETURN AIR RADIATION RECEIVER REFRIGERANT (12,22,ETC) RETURN AIR RADIATION SUPPLY AIR SEASONAL ENERGY EFFICIENCY RATING CFM, STANDARD CONDITIONS SIMILAR SEASONAL ENERGY EFFICIENCY RATING CFM, STANDARD CONDITIONS SIMILAR SEASONAL ENERGY EFFICIENCY RATING CFM, STANDARD CONDITIONS SIMILAR SEASONAL ENERGY EFFICIENCY RATING CFM, STANDARD CONDITIONS SIMILAR THERMOSTAT THROW AWAY TO BE DETERMINED TEMPERATURE CONTROL CONTRACTOR TEMPERATURE DIFFERENCE TEMPERATURE TOP OF TOTAL STATIC PRESSURE TYPICAL U HEAT TRANSFER COEFFICIENT UNO UNLESS NOTED OTHERWISE V VAC VAR VAV VEL VENT VERT VIF VOL W wb W/ WBT WH W/0 WPD WT WTF VOLT VACUUM VARIABLE VARIABLE AIR VOLUME VELOCITY VENTILATION, VENT VERTICAL VERIFY IN FIELD VOLUME WATT WET BULB WITH WET BULB TEMPERATURE WHITE WITH OUT WATER PRESSURE DROP WEIGHT WATER TEMPERATURE DROP ASBESTOS AWARENESS THE EXISTING BUILDING MATERIALS MAY CONTAIN ASBESTOS MATERIALS. REFER TO PROJECT MANUAL AND ASBESTOS CONSULTANT DOCUMENTS FOR MORE INFORMATION. IF ASBESTOS AND/OR SUSPECTED MATERIALS ARE DISTURBED AND/OR ENCOUNTERED, CEASE WORK OPERATION AND NOTIFY DIRECTOR'S REPRESENTATIVE IMMEDIATELY. 2 3 4 5 FAN SCHEDULE NO. LOCATION SERVICE TYPE QUANTITY CFM ESP (IN) HP (WATTS) FAN RPM DRIVE V/PH/HZ ELECTRIC DATA CONTROL NOTES MANUFACTURER MODEL EF -24 MACHINE ROOM MACHINE ROOM EXHAUST 2 1200 0.25 1/4 - DIRECT 115/1/60 EXISTING 4 DAYTON 10D963 EF -24A MACHINE ROOM (ELEVATOR 5) MACHINE ROOM SIDEWALL 1 2400 0.50 3/4 1522 DIRECT 115/1/60 2 -SPEED TSTAT 1, 2, 3 GREENHECK SEI -16 -436 -VG NOTES: 1. PROVIDE WITH FACTORY MOUNTED DISCONNECT SWITCH. 2. PROVIDE WITH WALL HOUSING WITH EXTERIOR FLANGE, GRAVITY BACKDRAFT DAMPER AND WEATHER HOOD. 3. PROVIDE WITH FACTORY WALL MOUNTED THERMOSTAT FOR 2 -SPEED FAN CONTROL. 4. RECONNECT NEW FANS TO EXISTING ELECTRICAL. SPLIT SYSTEM COOLING (DX) SCHEDULE NO. (INDOOR, OUTDOOR) LOCATION DX COOLING COIL DATA INDOOR UNIT OUTDOOR UNIT BASIS OF DESIGN MANUFACTURER MODEL NO. (INDOOR, OUTDOOR) CAP. MBH MIN. EER REFR. TYPE DRY CFM WET CFM WEIGHT (LB) TYPE MCA FAN MOTOR FLA POWER MAX FUSE MCA FAN MOTOR FLA WEIGHT (LB) AC -1, ACCU-1 MACHINE ROOM (ELEV 1/2) 30 9.5 R41OA 775 700 46 HIGH -WALL 1 .36 208/230V, 1 -PHASE 25 19 .40 151 MITSUBISHI PKA-A3OKA7, PUY-A3ONHA7 NOTES: 1. PERFORMANCE AT AHRI RATED CONDITIONS OF 80F DB, 67F WB (INDOOR) AND 95F DB5F WB (OUTDOOR). 2. PROVIDE WITH 3 -POLE DISCONNECT SWITCH. 3. PROVIDE WITH FACTORY WALL MOUNTED CONTROLLER. 4. PROVIDE WITH ADVANCED LOW AMBIENT KIT INCLUDING SIDE AND REAR WIND BAFFLES FOR OPERATION DOWN TO -20F OUTDOOR TEMPERATURES. 5. PROVIDE WITH 316 STAINLESS STEEL WALL MOUNTING BRACKET. A EXISTING LOUVER WALL / / / / / / M WALL SLEEVE HINGED ACCESS DOOR FOR FILTER REPLACEMENT (REQUIRED WHERE NOTED ON DRAWINGS) A REMOVABLE SAFETY GRILLE CONTROL DAMPER ELECTRONIC DAMPER ACTUATOR Machine Room Control Damper Detail NOT TO SCALE 3 EXISTING LOUVER / / / / / M GYPSUM WALL BOARD EXTERIOR SHEATHING. PROVIDE INFILL AS REQUIRED AT OPENING EXTERIOR INSULATION FINISH SYSTEM. CUT AS REQUIRED FOR INSTALLATION OF FAN. PATCH TO MATCH. MAINTAIN EXISTING WARRANTIES. FLASHING TAPE PERIMETER MOUNTING ANGLE WEATHER HOOD BIRD SCREEN BACKER ROD AND SEALANT AT PERIMETER 1 11111 fink,. " ... GRAVITY BACKDRAFT DAMPER PROVIDED WITH FAN ASSEMBLY WALL EXISTING WALL LOUVER. FIELD VERIFY DIMENSIONS. CONTROL DAMPER (REFER TO DRAWINGS FOR SIZING REQUIREMENTS) WALL SLEEVE OSHA APPROVED REMOVABLE SAFETY GRILLE CONTROL DAMPER ELECTRONIC DAMPER ACTUATOR (2) LAYERS 5/8" GYMSUM WALL BOARD TYPE "X". PROVIDE INFILL AS REQUIRED AT OPENING. CUT OPENING FOR NEW EXHAUST FAN. PROVIDE 6", 18 GAUGE METAL STUD AT PERIMETER OF OPENING. WALL HOUSING CLOSURE ANGLE 1"H E 111111; , 23 Propeller Fan Detail NOT TO SCALE Hoistway Control Damper Detail NOT TO SCALE 4 12" ELECTRONIC DAMPER ACTUATOR GALVANIZED SHEET METAL BLANK -OFF PANEL. FAN MOUNTED IN WALL HOUSING 5 A REMOVABLE REAR WIRE GUARD WALL HOUSING CONSISTING OF CONTINUOUS WALL SLEEVE AND EXTERIOR FLANGE FOR MOUNTING FAN FLUSH TO BUILDING EXTERIOR Statl er Hall and Hote Ithaca, New York 14850 BID DOCUMENTS 05.18.2018 Revisions HVAC Symbols, Abbreviations, Schedules, Details and Notes A I r Job No: 564.07 Client No: Drawn by: TJE Sheet No: H-500 D C B A 1 D C B A 1- 1 2 GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2014 EDITION OF THE NATIONAL ELECTRICAL CODE NFPA 70, LATEST NFPA 72, 110 & 720. 2. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND REPRESENT A COMPLETED PROJECT. MINOR MODIFICATIONS OF WORK SHALL BE PROVIDED BY THS TRADE TO COMPLY WITH PROJECT REQUIREMENTS, LOCATIONS OF DEVICES AND EQUIPMENT SHOW A GENERAL ARRANGEMENT AND INTENDED FUNCTION. ALL COMPONENTS SHOWN ON THE RISER DIAGRAMS, BUT NOT ON THE PLAN OR VICE VERSA, SHALL BE INCLUDED AS IF SHOWN ON BOTH. EXACT LOCATION OF MECHANICAL EQUIPMENT THAT REQUIRE ELECTRICAL CONNECTIONS ARE SHOWN ON THE MECHANICAL DRAWINGS. BEFORE INSTALLATION OF WORK, CHECK FOR SWINGS AND ALL REQUIRED CLEARANCES, TO AVOID INTERFERENCE WITH OTHER TRADES. COORDINATE WITH ALL CONTRACT DOCUMENTS, SHOP DRAWINGS AND EQUIPMENT DRAWINGS. 3. PROVIDE ELECTRICAL CONNECTION FOR EVERY FIXTURE, OR ITEM OF EQUIPMENT REQUIRING SAME, WHICH IS SHOWN ON ANY CONTRACT DRAWING OR NOTED IN ANY TECHNICAL SPECIFICATION. 4. INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND CONDITIONS FOR WARRANTY AND GUARANTEE. PROVIDE ALL ACCESSORIES REQUIRED FOR A COMPLETE AND SATISFACTORY INSTALLATION READY FOR CONTINUOUS USE. 5. GROUNDING: PROVIDE GROUNDING & BONDING IN ACCORDANCE WITH NEC ARTICLE 250. CONDUCTORS SHALL BE COPPER. ALL FEEDERS, BRANCH CIRCUITS, AND OTHER WIRING SYSTEMS SHALL HAVE A SEPARATE DEDICATED GREEN INSULATED GROUND WIIRE. BONDING: PROVIDE BONDING IN ACCORDANCE WITH NEC ARTICLE 250. ELECTRICALLY CONDUCTIVE MATERIALS ASSOCIATED WITH THE PROJECT SHALL BE CONNECTED TOGETHER IN A MANNER THAT CREATES A PERMANENT, LOW IMPEDANCE PATH FOR GROUND FAULT CURRENT. 6. ALL BRANCH CIRCUITS REQUIRING A NEUTRAL SHALL HAVE SEPARATE DEDICATED FULL SIZE NEUTRAL AND GROUND CONDUCTORS. 7. EXISTING SYSTEMS FEEDERS AND BRANCH CIRCUITS WHICH PASS THROUGH ALTERED AREAS AND SERVE OTHER AREAS SHALL BE MAINTAINED AS REQUIRED. THIS TRADE SHALL BE RESPONSIBLE FOR LOCATING AND AVOIDING THESE FEEDERS AND BRANCH CIRCUITS. IF DISTURBED, THEY SHALL BE REPAIRED AND BROUGHT BACK ON-LINE AS SOON AS POSSIBLE AND AT THE CONTRACTORS EXPENSE. 8. COORDINATE ARRANGEMENT, MOUNTING AND SUPPORT OF ELECTRICAL CONDUIT TO ALLOW MAXIMUM POSSIBLE HEADROOM IN THE CEILING CAVITIES. 9. PERFORM WORK AS REQUIRED BY CODES, REGULATIONS AND LAWS OF LOCAL, STATE AND FEDERAL GOVERNMENTS AND OTHER AUTHORITIES WITH LAWFUL JURISDICTION. APPROVED FOR INTENDED SERVICE. ALL MATERIAL AND EQUIPMENT SHALL BE UL, NEMA, ANSI, IEEE, ADA & CBM. COMPLY WITH APPLICABLE CORNELL STANDARDS AND GUIDELINES. 10. ALL WIRING SHALL BE RUN CONCEALED UNLESS SPECIFIED OTHERWISE. 11. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, RECTILINEAR/PARALLEL TO BUILDING STRUCTURE. 12. ALL RACEWAYS RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH EXPANSION FITTINGS. 13. MINIMUM BRANCH CIRCUIT WIRING SHALL BE NO. 12 AWG SOLID COPPER. BRANCH CIRCUITS LONGER THAN 75 FEET FOR 120V CIRCUITS SHALL BE AT LEAST #10 AWG FROM PANEL TO LAST OUTLET. 14. CUT AND PATCH BUILDING STRUCTURE AS REQUIRED. PROVIDE U.L. LISTED FIRE STOP METHODS FOR PENETRATIONS OF FIRE -RATED BUILDING COMPONENTS OR BARRIERS PER CONTRACT SPECIFICATIONS. 15. ELECTRICAL TRADE SHALL HELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK OR SHOP FABRICATION. REQUIRED CHANGES TO WORK SHOWN ON CONSTRUCTION DRAWINGS SHALL BE APPROVED BY THE ENGINEER IN WRITING AND OTHER TRADES AS REQUIRED PRIOR TO ANY CONSTRUCTION. 16. COORDINATE THE WORK OF THIS CONTRACT WITH THE WORK OF OTHER CONTRACTS/TRADES. COORDINATE ALL ROOF PENETRATIONS, SOFFITS, CHASES, AND PADS. COORDINATE WITH MECHANICAL CONTRACTOR, SPECIFICATIONS, AND POWER OUTLET SCHEDULES ON DRAWINGS FOR DETERMINATION OF RESPONSIBILITY TO FURNISH AND INSTALL ELECTRICAL COMPONENTS OF MECHANICAL EQUIPMENT. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WITH OTHER TRADES. 17. EXCEPT AS NOTED IN SPECIFICATIONS, ALL CUTTING AND PATCHING OF BUILDING COMPONENTS REQUIRED TO ACCOMMODATE THE WORK OF THIS CONTRACT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL TRADE, ALL PATCHING SHALL MATCH THE EXISTING COMPONENTS AND FINISHES. CUTTING AND PATCHING WORK SHALL BE PERFORMED BY PERSONNEL TRAINED AND REGULAR EMPLOYED FOR SUCH SERVICES. 18. ELECTRICAL TRADE SHALL PROVIDE NECESSARY SUPPORT FRAMING, STIFFENERS, BRACING, AND HANGERS WHETHER SHOWN OR NOT TO ENSURE A COMPLETE AND DURABLE SYSTEM. SUPPORT FRAMING CONNECTIONS SHALL BE WELDED UNLESS SPECIFICALLY SHOWN OTHERWISE. ACTUAL SUPPORTS MAY VARY FROM THOSE SHOWN IN DETAILS AND AS REQUIRED FOR EQUIPMENT TO BE FURNISHED OR FOR EXISTING FIELD CONDITIONS. 19. CEILING GRID MOUNTED LIGHTING FIXTURES WITH WEIGHT OF LESS THAN 10 POUNDS SHALL BE PROVIDED WITH ONE (1)12 GAGE HANGER FROM FIXTURE HOUSING TO STRUCTURE ABOVE. HANGER WIRE SHALL NOT HAVE MORE THAN ONE INCH SLACK. WIRING OF FIXTURES SHALL BE BY THE ELECTRICAL TRADE (TYP). CEILING GRID MOUNTED LIGHTING FIXTURE WEIGHING MORE THAN 10 LB. AND LESS THAN 56 LB SHALL BE PROVIDED WITH THREE (3) 12 GAGE HANGER WIRES CONNECTED TO THE FIXTURE HOUSING AND TO THE STRUCTURE ABOVE. HANGER WIRE SHALL NOT HAVE MORE THAN ONE INCH SLACK. 20. ALL FA CABLES AND CONDUCTORS SHALL BE INSTALLED IN CONDUIT PER THE CORNELL CONSTRUCTION STANDARD 16721 SECTION 2.03 FA SYSTEMS PATHWAYS . 21. LIGHTING IN HOISTWAY PITS SHALL BE ORIENTATED TO ILLUMINATE THE PIT LADDER AND ILLUMINATE THE PIT FLOOR TO AT LEAST 10 FOOT CANDLES. 22. ALL HEAT DETECTORS SHALL BE SELECTED TO COORDINATE WITH EXISTING SPRINKLERS. SUBMIT COORDINATION TO DIRECTOR'S REPRESENTATIVE FOR APPROVAL. 23. PROVIDE PULL STRING FOR ANY CONDUITS WHICH ARE INSTALLED AND EMPTY OR SPARE. 24. CONTRACTOR TO COORDINATE FINAL ELECTRICAL REQUIREMENTS WITH ELEVATOR CONTRACTOR. 25. CONTRACTOR TO FOLLOW CORNELL PROCEDURES FOR ACCESS AND WORK FACILITIES, 26. ARES OF WORK AND OTHER DISTRUBED AREAS DO FOLLOW A PHASING PLAN AND/ OR CONSTRUCTION SEQUENCE, REFER TO FRONT END DOCUMENTS AND OTHER DISCIPLINE PLANS. 27. RELATED POWER SHUT -DOWNS SHALL BE SCHEDULED IN ADVANCE WITH DIRECTOR'S REPRESENTATIVE, INDICATING AFFECTED CIRCUITS, AREAS/ROOMS AND POWER SHUT -DOWN DATE(S) AND TIME(S). CONSIDER AFTER BUSINESS AND/ OR WEEKEND HRS. TO COMPLETE PROJECT WORK WITH MINIMAL DISTURBANCE AND INTERRUPTIONS. 28. ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE SUITABLE FOR AREAS OF WORK. I.E HOISTWAY. ALL EXPOSED RACEWAYS SHALL BE PAINTED AND MATCH TO EXISTING WALL COLOR. UTILIZE SURFACE MOUNT RACEWAYS IN FINISH SPACES. 29. SALVAGE AND/OR RE -USED EQUIPMENT/MATERIAL SHALL BE PROTECTED FROM CONSTRUCTION OR STORED AND RE -INSTALL AS INDICATED. CLEAN AND PROVIDE NEW MOUNTING SUPPORTS AS REQUIRED 30. RELOCATE UNFORESEEN ELECTRICAL ITEM(S) IMPACTED BY NEW WORK AND NOT INDICATED SPECIFICALLY ON DOCUMENTS. MATCH WIRE, CONDUIT CHARACTERISTICS. 31. CONTRACTOR TO PROVIDE WALUFLOOR PENETRATIONS, AND PROVIDE FIREPROOF MATERIALS FOR INSTALLED CONDUIT(S) IN FIRE RATED FLOORS, WALLS. REFER TO DIVISION 7 SPECIFICATIONS. 32. CONTRACTOR TO PATCH, PAINT AND RESTORE TO ORIGINAL CONDITIONS DISTURBED AREAS OF WORK. MATCH TO FINISH COLOR, COORDINATE WITH GENERAL CONSTRUCTION CONTRACT. 33. PROVIDE 1P -20A CIRCUIT BREAKER(S) FOR NEW GENERATED 120V CIRCUITS AT EXISTING PANEL BOARDS. MATCH KAIC RATING AND PROPERTIES TO EXISTING PANEL BOARD(S). ASBESTOS AWARENESS THE EXISTING BUILDING MATERIALS MAY CONTAIN ASBESTOS MATERIALS. REFER TO PROJECT MANUAL AND ASBESTOS CONSULTANT DOCUMENTS FOR MORE INFORMATION. IF ASBESTOS AND/OR SUSPECTED MATERIALS ARE DISTURBED AND/OR ENCOUNTERED, CEASE WORK OPERATION AND NOTIFY CORNELL'S PROJECT REPRESENTATIVE IMMEDIATELY. 1 2 3 1 MISCELLANEOUS SYMBOLS #c PANELBOARD, WALL MOUNTED PANELBOARD, FLUSH MOUNTED MAGNETIC MOTOR STARTER FUSED DISCONNECT AS INDICATED. INDOOR NEMA 1. MOTOR CONNECTION - 1/2 INDICATES HORSEPOWER RATING MECHANICAL EQUPIMENT ITEM - # KEYED TO EQUIPMENT CIRCUITING & CONTROL SCHEDULE MECHANICAL EQUIPMENT ITEM EQUIPMENT ITEM CONTROL LOCATION - # KEYED TO EQUIPMENT CIRCUITING & CONTROL SCHEDULE -� HOMERUN TO PANEL LA -2. 2-#12 AWG IN 3/4" CONDUIT, FED FROM A 20AMP-1 POLE CIRCUIT /` `A-2 BREAKER FROM CIRCUIT #2; IS INTENDED UNLESS NOTED OTHERWISE. E JUNCTION BOX OR PULL BOX CIRCUIT BREAKER AS INDICATED EMERGENCY REMOTE PUSH BUTTON FIRE HEAD SPRINKLER Ex ELEVATOR WITH "X" REPRESENTING THE ELEVATOR NUMBER WIRING DEVICE SYMBOLS AM MEM e - DUPLEX RECEPTACLE GROUND FAULT INTERRUPTING TYPE RECEPTACLE GROUND FAULT INTERRUPTING TYPE RECEPTACLE INSTALLED ABOVE COUNTER BACKSPLASH DUPLEX RECEPTACLE - GFCI WITH WEATHERPROOF COVER QUAD RECEPTACLE SINGLE RECEPTACLE SPECIAL OUTLET (WITH CHARACTERISTICS AS NOTED ON PLANS) Eli WALL MOUNTED CABLE TV OUTLET - 1 GANG BOX WITH 3/4" CONDUIT (WITH PULLWIRE) TO ACCESSIBLE CEILING SPACE DATA OUTLET LUMINAIRE SYMBOLS A LUMINAIRES - A,B, ETC. INDICATE TYPES - REFER TO LUMINAIRE SCHEDULE B ETR OS 2'X4' LUMINAIRE (ETR INDICATES EXISTING TO REMAIN) LIGHT SWITCH - OS INDICATES OCCUPANCY SENSOR CEILING MOUNT OCCUPANCY SENSOR 4 FIRE ALARM SYSTEM SYMBOLS F MANUAL PULL STATION HEAT DETECTOR - MATCH TO EXISTING, UNLESS INDICATED OTHERWISE SMOKE DETECTOR CARBON MONOXIDE DETECTOR COMBINATION BELL/STROBE 15,30,75 ON PLANS INDICATES OF STROBE CANDELA "CO INDICATES CARBON MONOXIDE STROBE ONLY ACCESS CONTROL SYMBOLS (M) MOTORIZED DOOR OPENER ©l HANDICAP PUSH BUTTON ACTUATOR CR CARD READER DC DOOR CONTACT DS DOOR STRIKE © MAGLOCK DEVICE PB PUSH BUTTON El INTERCOM STATION DEVICE ER EXIT REQUEST BUTTON GENERAL REMOVAL NOTES 1. REMOVE INDICATED EXISTING ELECTRICAL IN AREA OF NEW CONSTRUCTION, UNLESS NOTED OTHERWISE. 2. CONTRACTOR IS ENCOURAGED TO VISIT SITE DURING PRE-BID MEETING TO IDENTIFY EXISTING CONDITIONS AND POSSIBLE DIFFICULTIES THAT WILL AFFECT THE DEMOLITION WORK. ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE DURING THE BID PROCESS. NO COMPENSATION WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED WILL BE GRANTED FOR ADDITIONAL WORK BY EXPERIENCED OBSERVERS. 3. EXISTING FIRE ALARM SYSTEM COMPONENTS TO REMAIN SHALL BE KEPT OPERATIONAL DURING THE CONSTRUCTION PERIOD. DETECTION DEVICES IN THE AREA UNDER RENOVATION WHERE CONSTRUCTION IS ONGOING MUST BE MANAGED WITH DIRECTOR'S REPRESENTATIVE'S APPROVAL BY EITHER SCHEDULING A FIRE PROTECTION SHUTDOWN THRU CUSTOMER SERVICES FOR EH EH&S TO REMOVE ON A DAILY BASIS OR THEY CAN BE CHANGED TO HEAT DETECTOR FOR THE DURATION AT THE PROJECT, AT PROJECT COMPLETION THE ORIGINAL SMOKE DETECTORS SHALL BE RETURNED TO SERVICE AND TESTED. 4. ELECTRICAL EQUIPMENT AND DEVICES WITHIN DEMOLITION AREA SHOWN TO BE DEMOLISHED, SHALL BE DEMOLISHED ALONG WITH ALL FEEDERS, BRANCH CIRCUITS, AND CONDUITS. WIRING SHALL BE REMOVED BACK TO SOURCE. REMOVE ALL CONDUITS ASSOCIATED WITH DEMOLISHED EQUIPMENT EXCEPT CONDUITS CONCEALED IN WALLS OR FLOOR SLABS, UNLESS NOTED OTHERWISE ON PLANS. 5. CONTRACTOR SHALL DISCONNECT, REMOVE AND MAKE SAFE ALL LIGHT FIXTURES, AND OTHER ASSOCIATED ELECTRICAL EQUIPMENT AND ALL ASSOCIATED CIRCUITRY WITHIN DEMOLITION AREA, EXCEPT AS SHOWN OTHERWISE. UPON REMOVAL, INVENTORY MAJOR ELECTRICAL ITEMS THAT ARE REMOVED AND PROVIDE A LIST TO THE OWNER FOR THEIR SELECTION OF ITEMS TO BE RETAINED. ALL ITEMS REJECTED BY THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. 6. IN ANY AREA REQUIRING THE PERFORMANCE OF ANY TRADE'S WORK, THIS TRADE SHALL CAREFULLY REMOVE AND STORE ANY OR ALL ELECTRICAL ITEMS IN PATH OF WORK, REINSTALLING AND RECONNECTING SAME AS REQUIRED, IN ACCORDANCE WITH THE PLANS AND/OR AS DIRECTED AFTER COMPLETION OF OTHER TRADE'S WORK IN THAT AREA. 7. AFTER RENOVATING EXISTING ELECTRICAL WORK, THE CONTRACTOR SHALL ENSURE THAT ALL REMAINING AND NEW EQUIPMENT WILL OPERATE PROPERLY. 8. ALL ELECTRICAL WORK INDICATED TO REMAIN SHALL BE SUITABLY PROTECTED TO PREVENT ANY DAMAGE. 9. WHERE ELECTRICAL SYSTEMS PASS THROUGH RENOVATED AREAS TO SERVE OTHER PORTIONS OF THE PREMISES NOT PART OF THIS PROJECT, SYSTEMS SHALL BE SUITABLY PROTECTED TO PREVENT DAMAGE OR RELOCATED AND THE SYSTEMS RESTORED TO NORMAL OPERATION. ANY OUTAGES IN SYSTEMS SHALL BE COORDINATED WITH OWNER. RESTORE POWER TO EXISTING TO REMAIN EQUIPMENT IF INTERRUPTED BY DEMOLISHED CIRCUITS IN THE AREA. 10. DAMAGE TO EXISTING FACILITIES AND EQUIPMENT SHALL BE REPAIRED OR REPLACED IMMEDIATELY AT NO ADDITIONAL EXPENSE. 11. CONTRACTOR TO MAINTAIN LIFE SAFETY SYSTEMS IN OPERATION AND HAVE MINMUM INTERUPTIONS DURING CONSTRUCTION PHASES. PROVIDE TEMPORARY POWER AND FIRE ALARM SYSTEMS AS REQUIRED, EXTEND SYSTEMS BEYOND WORK AREAS IF REQUIRED. 12. LIGHTING BALLAST, CAPACITORS AND LAMPS CONTAINING PCB'S, MERCURY OR OTHER HAZARDS AS DEFINED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA), SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE, FEDERAL, AND EPA REGULATIONS. THIS CONTRACTOR SHALL ALSO REFER TO OGS'S POLICY REGARDING REMOVAL AND DISPOSAL OF PCB BALLASTS. 3 4 5 GENERAL ABBREVIATIONS A ADA AFF AFG AHJ AHU AIC AL ANSI AR ARCH ATS ATC AWG BFG BLDG BMF C, CDT CAT CB CBM CKT CL CLF COL CPT CT CU DWG EC ETR EM EMT EPO ERGB EWC F FA FH FLA FMC FP FT GF GFCI GFI GND,G GRMC HOA IEEE IBGB IMC INT ITGB KCMIL KVA KW LTG LFMC MC MCB MCC MCP MISC MLO NC NEC NEMA NF NFPA NO NTS P PB PNL POS PR PVC PWR QTY REF REQ'D RMC RMS RNMC RTU SLC SP SS ST SW SYM TYP TEL TF TMCB UG UL UON, UNO V VP VT W WG WH WP XFMR XP Y 0 AMPERES AMERICANS WITH DISABILITIES ACT ABOVE FINISH FLOOR ABOVE FINISH GRADE AUTHORITY HAVING JURISDICTION AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY ALUMINUM AMERICAN NATIONAL STANDARDS INSTITUTE ALTERNATE RECALL ARCHITECT AUTOMATIC TRANSFER SWITCH AUTOMATIC TEMPERATURE CONTROL AMERICAN WIRE GAUGE BELOW FINISH GRADE BUILDING BALLAST MODULE - FLUORESCENT CONDUIT CATALOG CIRCUIT BREAKER CERTIFIED BALLASTS MANUFACTURERS CIRCUIT CENTERLINE CURRENT LIMITING FUSE COLUMN CONTROL POWER TRANSFORMER CURRENT TRANSFORMER COPPER DRAWING ELECTRICAL CONTRACTOR EXISTING TO REMAIN EMERGENCY ELECTRICAL METALLIC TUBING EMERGENCY POWER OFF ELECTRICAL ROOM GROUND BAR ELECTRIC WATER COOLER FUSE FIRE ALARM FIREMAN HAT LAMP IN CAB FULL LOAD AMPERES FLEXIBLE METAL CONDUIT FIRE PROTECTION FEET GROUND FAULT GROUND -FAULT CIRCUIT INTERRUPTER GROUND -FAULT INTERRUPTER GROUND OR GROUNDING GALVANIZED RIGID METALLIC CONDUIT HAND, OFF, AUTOMATIC SWITCH INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS INSPECTION BUILDING GROUND BUS INTERMEDIATE METAL CONDUIT INTERLOCK INFORMATION TECH. ROOM GROUND BAR THOUSAND CIRCULAR MILS KILOVOLT AMPERES KILOWATTS LIGHTING LIQUIDTIGHT FLEXIBLE METAL CONDUIT METAL CLAD CABLE MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOTOR CIRCUIT PROTECTOR MISCELLANEOUS MAIN LUGS ONLY NORMALLY CLOSED NATIONAL ELECTRIC CODE NATIONAL ELECTRICAL MANUFACTURES ASSOCIATION NON FUSED NATIONAL FIRE PROTECTION ASSOCIATION NORMALLY OPEN OR NUMBER NOT TO SCALE POLE PUSHBUTTON PANEL PROVIDED UNDER OTHER SECTIONS PRIMARY RECALL POLYVINYL CHLORIDE POWER QUANTITY ROOF EXHAUST FAN REQUIRED RIGID METAL CONDUIT ROOT MEAN SQUARED RIGID NON-METALLIC CONDUIT ROOF TOP UNIT SIGNAL LINE CIRCUIT SPARE SAFETY SWITCH SHUNT TRIP SWITCH SYMMETRICAL TYPICAL TELEPHONE TRANSFER FAN THERMAL MAGNETIC CIRCUIT BREAKER UNDERGROUND OR UNDERGRADE UNDERWRITERS LABORATORIES UNLESS OTHERWISE NOTED VOLT VANDAL PROOF VOLTAGE TRANSFORMER WIRE WIRE GUARD WATER HEATER WEATHER PROOF TRANSFORMER EXPLOSION PROOF DELTA WYE PHASE EQUIPMENT REMOVAL SYMBOLS �Y 1 ] I 0 i EXISTING LUMINANIRES(S) V3- EXISTING SWITCH Fes_ EXISTING DUPLEX RECEPTACLE F� EXISTING FIRE HEAT DETECTOR 01 EXISTING FIRE ALARM SMOKE DETECTOR HP EXISTING MOTOR CONNECTION K1 EXISTING DOOR ENTRY HANDICAP PUSH PLATE Li5;i EXISTING DOOR ENTRY INTERCOM STATION 5 G) 4- 0 Z 0 c 0 ru. 0 thaca, New York 14850 Seal BID DOCUMENTS 05.18.2018 Revisions ELECTRICAL General Notes and Symbols A 1 r Job No: 564.07 Client No: Drawn by: WHM Sheet No: E-100 M (D7) (26! 1 6A � 1O007 nu6o . 1o9 B A '4=74, 100081 l -Ka6E-� 1e6o . \ � � l00 |mF 186 (33) (32) 10056 / �- � � / �x \ \ \ 198 ._„3=_ .. — 197 /r— ' /i Jr, " �N L (38) (37) " 10092 10113 180 (3l) \30) FIRE ALARM V SOB PANEL ' 1,11 0114 )nOo4 r-- =— 199 (36) G0079 G8ON . G8OM i ; G0080 G85 3„; G85A -r ( /34•\ /33\ u 1 G80 � 0009 ^ FIRE ALARM; SUB PANEL G8OH G8OG ,,,,,,,,,,,,,,,,,,,,,,,,,,, G8o8 G800 ~ 091. 1 .1 10057 (29X20) `' + 10031 ` (27) 10030 10055 111 2 (26) • `~ 193 192 10076 | 10053 11006211 [ 90 10091 1 1n 10033 , 1) 0090 /3l\ (30) /29V2B) (Z7) (4`,:,,44) (24} /23) (22) 21) (2D/ (l8) I, 17) 3 I� (l5) (l4) () �EVATOR #5, ACT/ -(I'----- 100x2 ), 1 10059 (28i 146D 10075 GYP -sr 149E l400 149 ~~~~2 '-- 14ac 146 10051 ACT (25) G0051 -` FF 44.44.4.44 G0031 G70 [- ~� r � _ EXP 1 G75 � G0057 1 Goor6 1 [ G7Ux | F�� (P4} /4pA 149e 1 145B |46A| 145 14nA First Floor Plan 42 124 10046 GYP , 10038 121 121A 10003 ACT 135B 1 143 1 l43o 7,\ 135| 125 ' l2nx ELEVATOR #4 123 l3oo 11 201 LGVATOR- � Goo9u ] = � G0086 G0097 G57 | G0067 EXP U -- --'-------i! G55 ; �c ELEVATOR #5 ATS G0066 EXP ATS 4SB E4 &.E5 G5) G50 G52 ... sr ~~ ^ 1 G0069 ] r� _ | � ACT G0043 1 ACT G0099 FIRE ALARM SUB PANEL EXP t} G53A ACT Ground Floor Plan __ 1» 10064 FIRE �� �NTR�� 129 10063 �Z YH 3; ...� � � f� ] 10044 GYP EWE 10063 ACT ' UP 1003 10060 STATLER HALL 151, 1l4) STATLER HOTEL _� „� � 110 GYP 10042 GYP 10045 ELEVATOR #3 13l /l2! /l1| G0024 G0023 MAIN TELECOM ROOM UP „� 2013 117H , 117 nu^ 10020 n o, 107 ACT ELEVATOR #2 115F 108 • lox 10037 1 GYP 102 ACT ELEVATOR #1 ) 3i(2}(li k (4) /0} (9\ (8) (7)(<\ .„/ 008 G1Ox z4 ___ 10036 10041 (5} .^-'-----'^ � ~ 109 | 105 | DN ^ )� 7,(.32.„(33 ..... ===_N.=-,_-�� '----- ' G04 3s5 / ( }(2>( l} --' G0039 ELEVATOR #4 ACT ___ G0068 � v AT 1 G0020 s• ELECTRIC ROOM - NORTH 3 POWER . 00070 EX P Gpi 065 EXP u.� STATLER HALL __ UJ 0 t� G0059 EX P RATOR OM; 015 GO A L GO5D , ` GOO 10 ___ 4 5 SHEET KEYNOTE 0 1 PROVIDE REPLACEMENT 225A 3PB-REAKER FOR ELEVATOR EM DISTRIBUTION PANEL. 2 PROVIDE �" CONDUIT FROM ATS TO THE (3) PROPOSED ELEVATOR CONTROLLERS. El, E2, E3 EACH CONTROLLER SHALL RECEIVE (4) #12 CONDUCTORS FROM THE ATS. 3 REUSE CONDUIT FROM EDS4 TO EPHP, PROVIDE RE-ROUTING AND EXTENSION TO ATS 4SB & PROPOSED ELEVATOR CONTROLLER. PROVIDE (4) #12 CONDUCTORS FOR ATS SIGNALS TO E5 & (4) #12 CONDUCTORS FOR FUTURE E4 ELEVATOR CONTROLLER. THIS SECOND SET SHALL BE EXTENDED IN THE FUTURE. 4 GENERAL LOCATION OF HOTEL MAIN LOBBY DESK. EXISTING ANNUNCIATOR SHALL BE REMOVED AND PROPOSED ANNUNCAT0R INSTALLED. COORDINATE WITH DIRECTOR'S REPRESENTATIVE FOR EXACT LOCATION OF PROPOSED UNIT. 5 APPROXIMATE LOCATION OF PROPOSED REPLACEMENT ANNUNCIATOR USE EXISTING PATHWAY. 6 APPROXIMATE LOGATION OF FIRE ALARM CONTROL ROOM. CORE THROUGH CEILING / FLOOR AS NECESSARY FOR PROPOSED CONDUITS. 7 APPROXIMATE LOCATION OF COMMUNICATIONS VERTICAL CHASE. USE EXISTING 4" VERTICAL NIPPLE AT EACH FLOOR LEVEL TO PASS CONDUITS TO SPECIFIED DESTINATION. MAINTAIN CLEARENCES BETWEEN CONDUITS WITHIN SLEAVE. IF NIPPLE IS NOT AVAILABLE, CORE FLOOR AS NECESSARY. COORDINATE WITH OWNER ON CORING LOCATION WITHIN ELECTRIC ROOM PRIOR TO CORING HOLE. FIRE STOP AS REQUIRED AFTER INSTALLATION AT EACH PENETRATION CONFIRM METHOD WITDIRECTOR'S REPRESENTATIVE AND AHJ. IF NOT ALLOWED CORE FLOORI CEILING AS REQUIRED. 8 APPROXIMATE LOCATION OF ELECTRICAL VERTICAL CHASE. CORE FLOOR AS NECESSARY. COORDINATE WITH OWNER ON CORING LOCATION WITHIN ELECTRIC ROOM PRIOR TO CORING HOLE. FIRE STOP AS REQUIRED AFTER INSTALLATION AT EACH PENETRATION. 9 PROVIDE 2 ½" CONDUIT FROM EDS4 TO E5 MACHINE ROOM FOR REPLACEMENT EPHP. 10 FIELD VERIFY THE EXISTENCE OF PHYSICAL EQUIPMENT GROUNDING CONDUCTOR FROM EDS4 TO ATS 4SB & FROM ATS 4SB TO NORMAL POWER FEEDER BREAKER IN SOUTH MAIN ELECTRIC ROOM. IF NONE EXISTS PROVIDE PHYSICAL CABLE SIZED OR REQUIRED. 11 OWNER PROVIDED CONDUIT, CABLE / CONDUCTOR CONSISTING 0F3/4"CONDUIT, (2)1OAWG TWISTED PAIR SHIELDED FROM THE FACP TO EACH REMOTE FA PANEL IN A DAISY CHAIN METHOD. Acckitecturai Resources D 11u EXISTING DIRECTOR'S REPRESENTATIVE PROVIDED CONDUITS CONSISTING OF (2) 3/4' CONDUIT, ONE FOR FA AND ONE FOR ELEVATOR TELEPHONE 12 PROVIDE �»' CONDUIT. THE CONDUIT WILL BE FOR THE FA CIRCUITS. PROVIDE 4"X4" JUNCTION BOX ON EACH FLOOR IN ELECTRIC CLOSET FOR 24" SERVICE LOOP. CONDUIT SHALL TERMINATE IN E5 ELECTRIC MACHINE ROOM. IT WILL EXTEND TO E5 MACHINE ROOM & E4 FA CONDUIT. PROVIDE CABLE OR EQUAL BY FA. 13 PROVIDE 1^CONDUIT T0E5MACHINE ROOM. PROVIDE 474^ JUNCTION BOX. IT WILL EXTEND TO E4 DATA / ELEVATOR PHONE CONDUIT & E5 MACHINE ROOM. PROVIDE (4)22 AWG TWISTED PAIR FOR ELEVATOR TELEPHONE. LEAVE A 200' SERVICE LOOP FOR E4 IN E5 MACHINE ROOM IF CONDUIT BETWEEN E4 & E5 IS NOT PRESENT AND EXTEND 2 PAIR TO E5. PROVIDE (2)CAT GTOMACHINE ROOM. LEAVE 20O'SERVICE LOOP FOR E4|N E5 MACHINE ROOM IF CONDUIT 8ETWEEN E4 & E5 IS NOT PRESENT AND EXTEND THE 2ND CAT6 TO E5 TO ITS OWN J -BOX FOR FUTURE BMS. 14 PROV1DE �" CONDUIT FOR FA CIRCUITS. IT WILL EXTEND FROM FIRE CONTROL ROOM TO E3 ELECTRIC MACHINE ROOM, E3 MACHINE ROOM, PROVIDE FA CABLE AS SPECIFIED BY FA CONTRACTOR FOR EC INSTALLED AND OWNER PROVIDED CONDUIT. PROVIDE A 4"X4" JUNCTION BOX ON EACH FLOOR IN THE COMMUNICATIONS CLOSET & 24" SERVICE LOOP. CONDUIT WILL TERMINATE IN E3 ELECTRIC MACHINE ROOM. IT WILL BE EXTENDED TO E3 MACHINE ROOM. 15 PROVIDE 1" CONDUITTO E3 ELECTRIC MACHINE ROOM. PROVIDE 474^JUNCTION BOX. IT WILL EXTEND TO E3 MACHINE ROOM AND El & E2 MACHINE ROOM. PROVIDE (6)22 AWG TWISTED PAIR FOR ELEVATOR TELEPHONE (2) IN E3 AND (4) IN El & E2. PROVIDE (2) CAT6 TO EACH MACHINE ROOM, TERMINATE IN SEPARATE 4"X4" JUNCTION BOX. CONDUIT CONDUIT BETWEEN E3 ELECTRIC ROOM AND El, E2, ALL BE PROVIDED BY OWNER. EXTEND AS REQUIRED 5 C B _~ A thaca, New York 1 Seal BID DOCUMENTS 05.18.2018 Revisions ELECTRICAL GROUND FLOOR & FIRST FLOOR PLAN Client No: Drawn by: WHM Sheet No: E 101 H LINE OF ROOF BELOW 3 4 JNEE OF ROOF BELOW LINE OF HALL ROOF BELOW Roof Floor Plan D21 1" = 20'-0" 25) / —7 ( 24 ) ,„.. ) ( 12 ) 11 ) (,10) MACHINE ROOM 10063 EXP (9) (7)4-) / \ LINE OF HOTEL ROOF BELOW MACHINE ROOM 10064 EXP 6 ....... ,,,,,,, ROOM 60067 EXP Hotel Typical Floor Plan (6th - 9th) ( 26 ) 25) = 20'-0" .3-3333-3. In 24 ) ) (22 ) ( 21) ( 20 ( 19 ELEVATOR #4 MACHINE ROOM 44 LINE OF HALL ROOF BELOW 0 L 4 G B2 ( 26 ) 011 352 350 ELEVATOR #5 351 348 30045 ACT F.1 342 341 Typical Floor Plan (3rd - 5th) 340 338 n 1" = 20'-0" ( 24 ) 23 278A 4 272 270 9::: 33-37.37 ( 22 ) 20 ) 19) E ID) 4' 20052 2 253 250 ELEVATOR #5 255 255C 1 255A 1 040— 248 1 251 255G f 1.15)(14) 336 3 T DN I ELEVATOR #4 335 [ a35a 3a5c 626 624 622 ELEVATOR #3 STATLER HALL 1 STATLER HOTEL 620 618 3,5 3)1.2 616 628 621 619 ( 12 )( 11 ) „ (10) 9 } 61 4 ==, ELEVATOR #2 617 ........... 615 612 610 611 ( 8 ) 1— , 348 316 609 608 ELEVATOR #1 613 607 7 ) 314 5 4-) 312 30072 GYP 31-0 306 302 ELEVATOR #2 ,F) 335B 0 3a5A In 1? ( 16 ) 249B 20046 ACT 1 245 249A -1+ 241 243 243D 243C 15 ( 14) STATLER HALL 219_ 220 237 UP 235 243B Second Floor Plan = 2U-0" 2 STATLER HOTEL ( '3 <2 3 (, n., (1))) ( 8 ) 305 303 301 1 7 1 1 6 ) 4 ) 3,5 (3) ( 2 )(7) 3 20022 3.333,3. LEVATOR 20021 20020 I 215 #3 ELEVATOR #2 204A 204 (!,; 211 20042 4 204 443 201 203 5 SHEET KEYNOTES: 0 1 OWNER PROVIDED CONDUIT CONSISTING OF (4) CONDUITS .75" FOR FA, 1.25" FOR ELEC, 1" FOR ELEVATOR TELEPHONE & DATA, .75" FOR ATS SIGNALS. CONDUITS SHALL START IN THE ELECTRIC MACHINE ROOM UNDER E3 TO THE MACHINE ROOM OF E1, E2. 2 OWNER PROVIDED CONDUIT CONSISTING OF (4) CONDUITS .75" FOR FA, .75" FOR ELEC, 1" FOR ELEVATOR TELEPHONE & DATA, .75" FOR ATS SIGNALS. THESE SHALL SHALL EXTEND TO APPROXIMATELY UNDER THE MEDICINE ROOMS IN THE OVERHEAD. 3 PROVIDE - EXTEND CONDUIT IN BOTH ROOMS AS REQUIRED FOR THEIR CIRCUIT TERMINATIONS. CABLE AND CONDUIT AS INDICATED ON THESE DRAWINGS. 4 PROVIDE EXTENSION TO CONDUIT INTO MACHINE ROOM AND CORE DRILL AS REQUIRED INTO ROOMS. START IN THE ELECTRIC MACHINE ROOM E5 TO THE MACHINE ROOM OF E4. EXTEND CONDUIT IN BOTH ROOMS AS REQUIRED FOR THEIR CIRCUIT TERMINATIONS. CABLE AND CONDUIT AS INDICATED ON THESE DRAWINGS. 5 CORE DRILL AS REQUIRED. SEE SHEET E-101 FOR ADDITIONAL DETAILS. 6 CORE DRILL AS REQUIRED TO COMM ROOM BELOW AND FOR CONDUITS SEE SHEET E-101 FOR ADDITIONAL DETAILS. 5 D B A Arckitecturai Resources .3333.')1),.53F33,.<3.j3si.3.3'33.'4i.33.3.5.3333.3. 3 3 „ .3. • .13.333,33413<"334.333.„ ..<'.33.,333333.81'5,,..$$3'..0.: • ,3333313.3333333333.3333333331333333333333:333331),<333333333333:R3,3333.333333.333:33333333. ;33,33333<3331333333333333:3333333:333333333,3.:3333333,333333333:3333333333333333" G) x 0 c 0 ru. 0 G) c-0 o 00) .a. stu E .0- 00 •tc > c M 0 thaca, New York 1 Seal BID DOCUMENTS 05.18.2018 Revisions ELECTRICAL 2ND THRU ROOF A 1 r Job No: 564.07 Client No: Drawn by: WHM Sheet No: E-102 B A D C8> FI ELEVATOR #2 A 0 A G0071 GYP ELEVATOR #1 Enlarged Ground Floor Plan 1/4"= 1'-0n G0040 ACT 4 MACHINE ROOM El & E2 10064 EXP En En (6) UNE OFi"IOyT t t Enlarged Machine Room Plan 1/4" = 1'-0" (1-0) 5 KEYNOTES: Q 1. REMOVE EXISTING FA SYSTEM HEAD -END EQUIPMENT. PROVIDE FA SYSTEM AS OUTLINED IN VENDOR QUOTE. COORDINATE EXTENT OF REMOVALS WITH FA VENDOR. 2. AFTER THIS FA PANEL IS REMOVED THIS WILL BE THE LOCATION OF THE ELEVATOR EMERGENCY PANEL ELEVATOR TELEPHONE & ASSOCIATED UPS. THE OWNER WILL TERMINATE AN IP PHONE LINE WITH ATA IN THIS LOCATION. THE CONTRACTOR SHALL TERMINATE THE TELEPHONE LINE FROM THE ATA TO THE ELEVATOR TELEPHONE SYSTEM. 3. PROVIDE SHUNT TRIP CIRCUIT BREAKER FOR ELEVATOR FEEDER TO REPLACE EXISTING FUSED DISCONNECT SIZE CB TO EXISTING FUSE. FIELD VERIFY LOCATION. PROVIDE FA RELAY TO TRIP BREAKER CIRCUIT TO FACP. 4. APPROXIMATE LOCATION OF SPARE SLEEVES. 5. PROVIDE LUMINARIE(S), SNAP SWITCH, & GFCI DUPLEX RECEPTACLE TO REPLACE EXISTING. 6. PROVIDE DEVICES. CIRCUIT TO PROPOSED SLG. PROVIDE 3/4" CONDUIT FROM MACHINE ROOM. LOCATE DEVICES ADJACENT TO F.P. OR REQUIRED BY NFPA 72. 7. LOCATION OF ELEVATOR MACHINE ROOM PHONE. 8. PROVIDE REPLACEMENT SMOKE DETECTOR AND TERMINATE ON SLC. LOCATION OF DETECTOR PER NFPA 72. PROVIDE ALL CONDUIT AND CONDUCTORS AS REQUIRED. 9. PROVIDE ELEVATOR POWER SHUNT TRIP SUPERVISORY SIGNAL DEVICE AND CIRCUIT TO SLC. 10. SPLIT SYSTEM FOR MACHINE ROOM CLIMATE COOLING. COORDINATE EXACT LOCATION WITH DIRECTOR'S REPRESENTATIVE, PROVIDE 25A 208V IP BRANCH CIRCUIT 3# 10AW FROM ELECTRIC MACHINE E1.2.3 TO OUTDOOR UNIT. PROVIDE CIRCUIT FROM EPHP2. PROVIDE EXTENSION TO OWNERS PROVIDED CONDUIT AS REQUIRED AT BOTH END OF CIRCUIT AND INDOOR UNIT. 11. PROVIDE SMOKE DETECTOR WITH INTEGRAL BASE TO CONTROL SMOKE DAMPERS. 12. PROVIDE 20A 120V IP CIRCUIT FROM EPHP2 TO MACHINE ROOM El, 2 FOR SMOKE DAMPER, THIS SHALL BE WIRE THAN CONTROL RELAY INTEGRAL WITH THE SMOKE DETECTOR. 13. APPROXIMATE LOCATION OF CAR LIGHTING DISCONNECTS SEE E-501 VIEW 2 FOR CIRCUITING D C C B A 10049 ACT 127 FIRE CONTROL 129 10065 Enlarged Fire Control Room Plan 1/4' = 1'-O" COC (4) DATA ROOM 625 EXP Enlarged Data Room Plan 1/4"= 1'-0" 123 10064 B4 4 311 FP AT TOP OF HOISTWAY u u ELEVATOR #2 (6) 30072 GYP )X FP ELEVATOR #1 1 Enlarged Typical Floor Plan (3 - 9) 1 /4" = 1'-0" 215 (8) ELEVATOR #2 Enlarged Second Foor Plan 22040 GYP ELEVATOR #1 1/4"= 1'-0" 107 ACT (8) C] ELEVATOR #2 10037 GYP 309 20023 ELEVATOR #1 Enlarged First Floor Plan 3 1/4"= 1'-0" 4 5 G0145 ACT W c-0 o N �, E E p t3 Q x P.'i 15 CD c } i thaca, New York 14850 Seal BID DOCUMENTS 05.18.2018 Revisions ELECTRICAL Elevators #1 and #2 Enlarged Floor Plans A 1 r Job No: 564.07 Client No: Drawn by: WHM Sheet No: E-401 D C B A 1 D C B A 1- 1 G0093 EXP (Q) Enlarged Ground Floor Plan 1 /4" = 1 '-0" 1 G0075 ACT G50 2 Wv MACHINE ROOM E5 60067 EXP PROPOSED ELEVATOR PHONE U EPSP EPSP2 EXISTING E3 & E4 SHUNT \ TRIP BREAKERS— EIED Enlarged Machine Room Plan 1/4" = 1'-0" 385 EXP EXISTING TOP OF HOISTWAY ELEVATOR #5 C<> (10 Enlarged Typical Floor Plan (3 - 5) 1/4" = 1'-0" 25. 285 EXP 30045 ACT 352 ELEVATOR #5 DB2 Enlarged Second Foor Plan 1/4" = 1'-0" 10082 EXP C Ki 20046 ACT 253 146D ELEVATOR #5 4 1 Enlarged First Floor Plan M2 1/4!' = �s (10 2 10075 GYP 10052 ACT 1 3 10039 3 10063 ACT ELEVATOR #3 I Enlarged First Floor Plan 117 1/4" = 1 '-0" K10) G0041 ACT GFI A fr <0> ELEVATOR #3 A 0 G15 Enlarged Ground Floor Plan 1/4" = 1 '-0" 3 4 {, 1 2. 4 7_-.- 11 13 IT PROPOSED ELEVATOR PHONE E1 (14 MACHINE ROOM E3 10063 EXP Enlarged Machine Room Plan 1/4" = 1 '-0" N DN PROPOSED ELEVATOR PHONE PANEL EPHP2 MCC PANEL EPHP 5 KEYNOTES: 0 1 NOT USED. 2 PROVIDE LUMINARIE(S), SNAP SWITCH, & GFCI DUPLEX RECEPTACLE TO REPLACE EXISTING. 3 PROVIDE DEVICES. CIRCUIT TO PROPOSED SLC. PROVIDE 3/4" CONDUIT FROM MACHINE ROOM. LOCATE DEVICES ADJACENT TO F.P. OR REQUIRED BY NFPA 72. 4 APPROXIMATE LOCATION FOR PROPOSED CONDUITS. FIELD VERIFY WITH DIRECTOR'S REPRESENTATIVE FOR BEST LOCATION, SEE E-101 KEYNOTE FOR ADDITIONAL INFORMATION. 5 AREA WAY TO TRANSITION CONDUITS FROM ELECTRIC CHASE INTO MACHINE ROOM. 6 PROVIDE LUMINARIES, SNAP SWITCH, & GFCI DUPLEX RECEPTACLE. PROVIDE A 15A 120 V BRANCH CIRCUIT FROM CLOSEST NORMAL POWER PANEL. COORDINATE WITH DIRECTOR'S REPRESENTATIVE ON PANEL. PROVIDE CIRCUIT BREAKER, CONDUIT & CONDUCTORS AS REQUIRED. ASSUME 150' LINEAR FEET OF CIRCUIT. 7 EPSP PANEL TO BE REPLACED. SEE ONE LINE FOR DETAILS. E-502 8 PROVIDE DEVICE AND CIRCUIT TO NEAREST NAC. 9 PROVIDE 15A 120V CIRCUIT FROM EPSP2 TO THIS LOCATION FOR FAN. INCLUDE LOCAL NON FUSED DISCONNECT. 10 PROVIDE REPLACEMENT SMOKE DETECTOR AND TERMINATE ON SLC. LOCATION OF DETECTOR PER NFPA 72. PROVIDE ALL CONDUIT & CONDUCTORS AS REQUIRED. 11 PROVIDE SHUNT TRIP CIRCUIT BREAKER FOR ELEVATOR FEEDER TO REPLACE EXISTING FUSED DISCONNECT. FIELD VERIFY LOCATION. PROVIDE FA RELAY TO TRIP BREAKER CIRCUIT TO FACP SIZE CB TO EXISTING FUSE. 12 PROVIDE ELEVATOR POWER SHUNT TRIP SUPERVISORY SIGNAL DEVICE AND CIRCUIT TO SLC. 13 PROVIDE UPGRADE FEEDER CIRCUIT FROM EPDHP TO EPAP2. THIS INCLUDES 35 KWA XFMR, CONDUCTORS, AND 45 A FEEDER BREAKER. 14 PROVIDE SMOKE DETECTOR WITH INTEGRAL RELAY BACK TO CONTROL SMOKE DAMPER 15 PROVIDE 20 A 120V IP CIRCUIT TO POWER SMOKE DAMPERS CIRCUIT TO RELAY BASED SMOKE DETECTORS IN MACHINE ROOM E3 AND E1/2.CONTINUE FROM RELAY TO EACH SMOKE DAMPERS IN E3 AND El, E2 MACHINE ROOM Enlarged Electrical Penthouse Plan 1/4" = 30073 GYP 30042 ACT ELEVATOR #3 TOP OF HOISTWAY )x FP APPROXIMATE LOCATION AT THE TOP OF HOIST WAY 4 Enlarged Typical Floor Plan (3 - 9) 4/ 1/4"=1'-0" 20073 ACT ELEVATOR #3 L 215 Enlarged Second Foor Plan 1/4" = 1 '-0" 4 5 W O 0 � o E stu E c; p 8 •tt _�- „ O P.'0 15 CD c LiTI thaca, New York 14850 Seal BID DOCUMENTS 05.18.2018 Revisions ELECTRICAL Elevators #3 and #5 Enlarged Floor Plans Al r Job No: 564.07 Client No: Drawn by: WHM Sheet No: E-402 i D C B A 1 2 PFN EXISTING 1P CB FROM EM PANEL OF RESPECTIVE CAR FOR ELEVATORS 1, 2, 3, & 5. RE-ROUTE EXISTING LIGHTING CIRCUIT FROM ELEVATOR TRAVELING CABLE TO PROPOSED ELEVATOR CONTROLLER. PROPOSED DISCONNECT INSTALLED BEFORE ELEVATOR CONTROLLER. EXTEND TO ELEVATOR CONTROLLER AND TERMINATE. 2 PARTIAL POWER RISER DIAGRAM FOR ELEVATOR CAB LIGHT SCALE: NONE FACP RM 129 <SLC <SLC REMOTE ANNUNCIATOR FACILITY MGR. OFFICE REMOTE ANNUNCIATOR SCHOOL MAIN ENTRANCE REMOTE ANNUNCIATOR BEHIND MAIN HOTEL DESK REMOTE ANNUNCIATOR ROOM 10059 HOTEL SERVICE ENTRANCE REMOTE PANEL RM G0099 REMOTE PANEL RM G85A REMOTE PANEL RM 10114 1 2 VIEW NOTES: gi z ® SHUNT TRIP FOR ELEVATOR (PROVIDE ONE FOR EACH PROPOSED TRIP BREAKER) SERVICES ARE REQUIRED 1. EXISTING FACP, REMOTE PANELS & REMOTE ANNUCIATORS SHALL BE REPLACED WITH NEW EQUIPMENT. PER QUOTATION SUBMITTED BY DAVIS ULMER DATED 4/6/2018.ENSURE THE FOLLOWING BYPASS SWITCHES ARE INCLUDED ON THE ON THE FALVI HORNS, AUXILIARY, SPRINKLER AND ELEVATOR. INCLUDE TWO ADDITIONAL BYPASS SWITCH TO BE DETERMINED BY DIRECTOR'S REPRESENTATIVE. 2. FURNISH 2 SLC'S ONE IN EACH BUILDING. THE CHASE SHALL BE SHOWN ON THE PLAN DRAWINGS. DEVICES & APPLIANCES AS INDICATED ON THE TABLE IN DETAIL 2 ON SHEET E-502 AND ON DRAWINGS. 3. MAKE ALL CONNECTIONS, PROVISIONS FOR FIRE ALARM PANEL. EXTEND ALL CIRCUITS AS NECESSARY. 4. MAINTAIN EXISTING SEQUENCE OF OPERATION FOR THE ENTIRE SYSTEM. 5. PROVIDE TEMPORARY FIRE ALARM AND FIRE WATCH PROVISIONS AS REQUIRED. COORDINATE FIRE WATCH PERSONEL WITH DIRECTOR'S REPRESENTATIVE. THIS LABOR IS NOT INCLUDED IN THIS CONTRACT. 6. SEQUENCE OF CONSTRUCTION SHALL BE PER THE FRONT END DOCUMENTS AND WILL BE COORDINATED WITH THE FA CONTRACTOR AND DIRECTOR'S REPRESENTATIVE PARTIAL FIRE ALARM RISER DIAGRAM (REFERENCE ONLY) SCALE: NONE 3 3 TELEPHONE LINE IP i —FLUSH TYPE 16 ZONE`2500 16RCF F.A.C.P. ROOM 109 HOTEL FRONT DESK UPS RP700104 StBMA 1'6 Z0NE 25 OEM - SYSTEM ALARM BOARD (SUBRP7900600) & JUNCTION BOARD (RP7900601) VIEW NOTES: BASIS OF DESIGN RATH MICROTECH IP TELEPHONE LINE PROVIDED BY OWNER 4 ,(zs4/ MACHINE & ELECTRIC ROOM MACHINE ROOM 2$004$100,0R MACHINE ROOM 0 030RC< r 00 ORC MACHINE ROOM 1 G-9 El G-9 E2 E3 ;2300 30RC L MACHINE & ELECTRIC ROOM 10RC. E4 E5 ELEVATOR TELEPHONE SYSTEM DEVICES SCALE: NONE MASTER BASE STATION MACHINE & ELECTRIC ROOM ROOM 109 SUB MASTER HOTEL MAIN DESK E1, E2, E3 MACHINE ROOM MACHINE & ELECTRIC ROOM E4, E5 E1, E2 MACHINE ROOM E3 T El E2 E3 =1 MACHINE ROOM E4 E5 E4 HOTEL LOBBY G0071 SERVICE ELEVATOR G0041 FREIGHT ELEVATOR G0047 PASSENGER ELEVATOR G0075A LOCATION G0071 G0041 G0075A G0047 ELEVATOR TELEPHONE SYSTEM CABLE ONE -LINE SCALE: NONE VIEW NOTES: 1. "T" PART OF TRAVELING CABLE. COORDINATE WITH ELEVATOR CONTRACTOR FOR CONDUCTOR IN TRAVELING CABLE. 2. ELEVATOR CONTRACTOR SHALL CONFIRM WITH MANUFACTURER THAT ALL REQUIRED EQUIPMENT IS INCLUDED FOR THIS INSTALLATION. 4 5 SHEET KEYNOTES: 1. AF1 SHALL BE LOCATED IN CAR OPERATING PANEL AS SPECIFIED ON ELEVATOR DRAWINGS. 2. OWNER PROVIDED CONDUIT 3. NOT USED 4. CABINET SHALL BE INSTALLED FLUSH WITH ELEVATOR CONTROL CENTER IN FA CONTROL ROOM. FABRICATE NECESSARY BRACKETS TO ATTACH CABINET TO FRONT PANEL. 5. PROVIDE REQUIRED 22AWG TWISTED PAIR FOR INSTALLATION OF EQUIPMENT & CIRCUITS. INCLUDE AT LEAST ONE EXTRA PAIR IN EACH RUN FOR SPARE. COORDINATE WITH ELEVATOR CONTRACTOR FOR CONDUCTORS IN THE TRAVELING CABLE. 5 Aut es nes O c 0 0 c-0 0 �N o. c ri; •O 1- O 0 ED.0u- _W W 0 Ithaca, New York BID DOCUMENTS 05.18.2018 Revisions ELECTRICAL DETAILS Air Job No: 564.07 Client No: Drawn by: WHM Sheet No: E-501 D C B A 1 D C B A 1 VIEW Notes: 1) El, E2, E3 have three machine rooms 2) E4 & E5 have two machine rooms 3) SHADED SERVICES SHALL BE INSTALLED OR REPLACED 2 3 Device E1 ID# E2 Room # E3 Room E4 15W LED E5 Pit Main 129 FACP Room (FIRE CONTROL) smoke N/A N/A Remote Annunciator N/A GO5C N/A Maintenance Supervisor Heat N/A N/A N/A N/A 10049 Hotel Service Entrance 10059 School Front Entrance Ground Remote Panel smoke 2-40 G0099 2-40 Electric Room 2-46 n/a 2-17 Heat 10114 Janitor's Closet 1st smoke 1-54 1-54 1-39 1-44 25-17 Heat 2nd smoke 25-37 25-37 25-50 10-40 26-1 Heat 3rd smoke 26-50 26-50 10-23 21-9 21-22 Heat 4th smoke 21-51 21-52 10-11 21-20 21-16 Heat 5th smoke 22-2 22-2 10-18 10-32 10-35 Heat 6th smoke 22-5 22-5 23-4 Heat 7th smoke 23-51 23-51 23-11 Heat 8th smoke 24-21 24-21 23-19 Heat 9th smoke 24-51 24-51 9-4 Heat Shaft smoke Install Install Install Exists (need device number) Heat Install on SLC Install on SLC Install on SLC r 10-46 10-37 Machine Rm smoke Install Install Install 10-31 r 10-50 Heat Install " P" 9-58 9-58 r 10-48 10-58 Shunt Trip Install Install Install Exists Exists Horn/Strobe Install Install Install Install ST Supervisory Install Install Install NA NA Electric Rm Smoke Install Install Install NA NA Heat Install Install Install NA NA Horn/Strobe Install Install Install NA NA VIEW Notes: 1) El, E2, E3 have three machine rooms 2) E4 & E5 have two machine rooms 3) SHADED SERVICES SHALL BE INSTALLED OR REPLACED 2 3 Device FIXTURE TYPE ID# VOLTAGE Room # A Room 120-277V 15W LED Main 129 FACP Room (FIRE CONTROL) Remote Annunciator GO5C Maintenance Supervisor G0145 Hotel Main Desk 10049 Hotel Service Entrance 10059 School Front Entrance Remote Panel G0099 Electric Room G85A Mechanical Room 10114 Janitor's Closet FA EQUIPMENT LOCATION SCALE: NONE FA DEVICE & APPLIANCE: EXISTING & PROPOSED TABLE SCALE: NONE LUMINAIRE SCHEDULE FIXTURE TYPE DESCRIPTION AND CATALOG NUMBER VOLTAGE LAMPS A BASIS OF DESIGN, METALUX 4VT2-LD4-6-DR--WUN-V-L840-CD1-WL-SSL-TEH-VT2-SS-MBK-U 120-277V 15W LED 2 3 1 MS4H MS4S GEN SET N_400A 4 15A P 3 #12 AWG 24V CONTROL 3/4" EMT TRANSFORMER 15A roiN EPHP2 ECC -MCC 12 CHANNEL TRAVELING CABLE r 1 "GO FAR" MCC KIT INSTALLED IN MACHINE ROOM ADJACENT TO HOISTWAY 1 1 ECU 1 READER (----- INSTALLED IN CAR CALL PANEL BELDEN PN 9729 BUNDLED IN TRAVELING CABLE COORDINATE WITH ELEVATOR CONTRACTOR VIEW NOTES: 1. ELEVATOR ACCESS CONTROL SYSTEM SHALL BE SOURCED FROM SAFLOK. 2. PROGRAMMING OF SYSTEM SHALL BE COMPLETED BY CONTRACTOR. 3. CONTRACTOR SHALL PROVIDE 2 HOURS OF PROGRAMMING FOR 3 CORNELL DESIGNATED PERSONNEL. ELEVATOR FLOOR ACCESS SYSTEM: E l , E2, E3 SCALE: NONE N__400A EDP RTS 4HB • • 225A • L_ — — — —I ED4HB EPHP 0 O • 1 GENERAL NOTES: ATS 4SB 1. SIMPLIFIED DRAWING. NOT ALL DEVICES OR WIRING SHOWN. VIEW KEY NOTES: O THESE FUSED DISCONNECTS SHALL BE REPLACED WITH A SHUNT TRIP CIRCUIT BREAKER. THE POWER FOR THE SHUNT TRIP WILL BE SOURCED FROM A NEW BRANCH CIRCUIT FROM EPHP2 PANEL. EACH SHUNT TRIP WILL BE PROTECTED INDIVIDUALLY. Q THE CONTACTORS ARE INDIVIDUAL FIRE ALARM RELAYS FROM THE PROPOSED FA CONTROL CIRCUITS. 225A ED4SP 0 PROVIDE REPLACING EXISTING 100A PANEL WITH 225A-3PH-4W 42 CIRCUIT SPACE PANEL. 22 KAIC AND CIRCUIT BREAKERS TO MATCH EXISTING. THIS SHALL BE FULLY RATED TERMINATE ALL EXISTING CIRCUITS. PROVIDE ARC FLASH WARNING LABEL FOR PANEL FRONT. REPLACE 100A BREAKER IN ED45SP WITH 225A 3P BREAKER WITH SAME AIC AS EXISTING. ® 4 #4/0 AWG, CU + 1 #4 AWG,CU GND IN 2-1/2" EMT O BOTH ATS'S WILL HAVE A FULL UPGRADE TO THE CONTACTOR AND CONTROLLER. THIS WILL BE SOURCED TO RUSSELL ELECTRIC PER QUOTE 3281820542 ATS 4HB WILL HAVE 6 SIGNAL CIRCUITS & ATS 4SB WILL HAVE 4 SIGNAL CIRCUITS. THE SIGNAL CIRCUITS ARE TO CAUSE A DISPLAY WHEN THE ELEVATOR IS ON EMERGENCY POWER & TO SIGNAL THE ELEVATOR CONTROLLER BEFORE POWER IS RETURNED TO UTILITY WITH A DELAY IN THE TRANSITION. SPECIFY ELEV 3 FOR EACH CONTROLLER ITO HAVE REQUIRED NUMBER OF CONTROL CONTACTS, VERIFY WITH MANUFACTURER PROGRAM DELAYS AS REQUIRED FOR ELEVATOR CONTROLLER SIGNALING. ® PROVIDE REPLACEMENT BRANCH CIRCUITS CONDUCTORS FROM PANEL TO EACH SHUNT TRIP BREAKER. 4 5 ST 100A 100A EPSP ST 15A I EPHP2 E3 11— E5 El BREAKER SHUNT TRIP E2 BREAKER SHUNT TRIP E3 BREAKER SHUNT TRIP PROPOSED CIRCUIT FOR SHUNT TRIP BREAKERS PARTIAL EXISTING ONE -LINE WITH MODIFICATIONS SCALE: NONE 5 G) 4- 0 0 c 0 ru. 0 W c -0 0 O 0) .N o, W -o 0 Q • 11": O thaca, New York 14850 Seal BID DOCUMENTS 05.18.2018 Revisions ELECTRICAL DETAILS AlrJob No: 564.07 Client No: Drawn by: WHM Sheet No: E-502