HomeMy WebLinkAboutBuilding 3 - Elevator Inspection ReportElectric Elevator
Acceptance Inspection & Witness
of Test Report
#2 MRL Trac Build 3A
210 College Ave.
Ithaca, NY 14850
Owner: Catherine Commons Apartments
Passenger
3500
2024
Schindler
Type
Rated Load
Year Constructed
Manufacturer
5/21/2024
Winslow, Dan
E000570
QEITF
Date of Report
Inspector
QEI Certification #
QEI Cert. Issuer
240516-00-1F73-T
Ithaca, City of
Workorder Designator
Authoritative Jurisdiction
All Inspection & Test Items in Compliance Per ASME A17.1
Test Results
Normal Car Operation
Empty Car Speed Up: 150 fpm
Empty Car Speed Down: 150 fpm
Full Car Speed Up: 150 fpm
Full Car Speed Down: 150 fpm
Standby Power Car Operation
Empty Car Speed Up: 150 fpm
Empty Car Speed Down: 150 fpm
Full Car Speed Up: 150 fpm
Full Car Speed Down: 150 fpm
Load
Load Placed on Car: 4375 lbs
Governor
Data Plate: 196 fpm
Trip Speed: 190 fpm
Buffers
Runby to CW Buffer: 7 inches
Miscelaneous
Top of Car Clearance: 60 inches
Notes
Re-acceptance of previous acceptance see previous report for additional results.
DJW Inspected to ASME A17.1 - 2016 and BCNYS - 2020
NYS Inspectors license # 23-6L5P9-SHEL
NYS Licensed Schindler Mechanic Nick Griesmyer
Inspector's Note:
Building 1, Elevator #2, Schindler MRL Traction, 3500 Lbs Capacity, 150 FPM.
Duplex with Elevator #1
JH located top landing across the hall continued on next page
#2 MRL Trac Build 3A
210 College Ave.
Ithaca, NY 14850
Owner: Catherine Commons Apartments
2
5/21/2024
Winslow, Dan
240516-00-1F73-T
Page
Date of Report
Inspector
Workorder Designator
Inspector's Signature
This conveyance inspection was performed in compliance with the applicable provisions of ASME A17.2 Guide for Inspection of Elevators, Escalators, and Moving walks. The
owner retains full responsibility to maintain this conveyance in compliance with all applicable laws, ordinances and regulations. The Authority Having Jurisdiction retains all
rights and responsibilities, as defined by applicable law, regarding verification of compliance.
Electric Elevator
Acceptance Inspection & Witness
of Test Report
#1 MRL Trac Build 3A
210 College Ave.
Ithaca, NY 14850
Owner: Catherine Commons Apartments
Passenger
3500
2024
Schindler
Type
Rated Load
Year Constructed
Manufacturer
5/21/2024
Winslow, Dan
E000570
QEITF
Date of Report
Inspector
QEI Certification #
QEI Cert. Issuer
240516-00-1F72-T
Ithaca, City of
Workorder Designator
Authoritative Jurisdiction
All Inspection & Test Items in Compliance Per ASME A17.1
Test Results
Normal Car Operation
Empty Car Speed Up: 150 fpm
Empty Car Speed Down: 150 fpm
Full Car Speed Up: 150 fpm
Full Car Speed Down: 150 fpm
Standby Power Car Operation
Empty Car Speed Up: 150 fpm
Empty Car Speed Down: 150 fpm
Full Car Speed Up: 150 fpm
Full Car Speed Down: 150 fpm
Load
Load Placed on Car: 4375 lbs
Governor
Data Plate: 196 fpm
Trip Speed: 190 fpm
Buffers
Runby to CW Buffer: 7 inches
Miscelaneous
Top of Car Clearance: 60 inches
Notes
Re-acceptance of previous acceptance see previous report for additional results.
DJW Inspected to ASME A17.1 - 2016 and BCNYS 2020.
NYS Inspectors license # 23-6L5P9-SHEL
NYS Licensed Schindler Mechanic Nick Griesmyer
Inspector's Note:
Building 3A, Elevator #1, Schindler MRL Traction, 3500 Lbs Capacity, 150 FPM
Duplex with Elevator #2.
JH located top landing across the hall.continued on next page
#1 MRL Trac Build 3A
210 College Ave.
Ithaca, NY 14850
Owner: Catherine Commons Apartments
2
5/21/2024
Winslow, Dan
240516-00-1F72-T
Page
Date of Report
Inspector
Workorder Designator
Inspector's Signature
This conveyance inspection was performed in compliance with the applicable provisions of ASME A17.2 Guide for Inspection of Elevators, Escalators, and Moving walks. The
owner retains full responsibility to maintain this conveyance in compliance with all applicable laws, ordinances and regulations. The Authority Having Jurisdiction retains all
rights and responsibilities, as defined by applicable law, regarding verification of compliance.