Loading...
HomeMy WebLinkAboutWall DesignF40 FND WALL 1'-1 1/4" ICF (T Y P ) 1' - 8 " F T G (T Y P ) 1' - 8 " F T G FOOTING DRAIN AT BUILDING PERIMETER FOOTING DRAIN AT BUILDING PERIMETER. EXTEND TO DAYLIGHT WA L L 8" F N D N [640'] [640'] [640'] [640'] [6 4 0 ' ] [640'] [640'] [XX] CRAWLSPACE: 15 MIL VAPOR BARRIER OVER 6" PEA GRAVEL. T/SLAB = XX'-X" T/WALL @ OPNG = 642'-8" [640'] T/WALL=650' (TYP) T/WALL = 645'-4" (TYP) T/WALL = 645'-4" (TYP) ICF WALL TRANSITION ICF WALL TRANSITION T/WALL = 650' BEARING POCKET FOR SIMPSON STRONG TIE TYP GLB5D BEAM SEAT SUPPORTING (3) 16" LVL'S. BEARING POCKET FOR SIMPSON STRONG TIE TYP GLB5D BEAM SEAT SUPPORTING (3) 16" LVL'S. BEARING POCKET FOR SIMPSON STRONG TIE TYP GLB5D BEAM SEAT SUPPORTING (3) 16" LVL'S. [6 4 0 ' ] T/WALL = 644' 4" SLAB OVER 6" COMPACTED SLAB SUBBASE. REINFORCE WITH 6x6-W4xW4 WWR. T/SLAB = 643'-0" [XX] T/WALL = 645'-4" (TYP) [XX] T/WALL AT CRAWLSPACE ACCESS = -4'-0 3/4" PROVIDE (2) ROWS #6 DOWELS @ 12" O.C. GROUT 6" INTO ICF WALL. TYPICAL @ EACH END OF WALL TYPICAL ALL PSL BASE CONNECTORS: SIMPSON STRONG-TIE MODEL BC POST BASE. 12 ' - 0 " 24'-0"16'-0"18'-0" 24'-0"11'-10"11'-6"10'-8" 4' - 0 " 8' - 0 " 64 ' - 0 " 8' - 0 " 56 ' - 0 " 8'-2"4'-3 1/2"3'-10 1/2"6'-8 1/2"9'-7 1/2" 32'-8" 8'-4"8'-4" 16 ' - 6 3 / 4 " 12 ' - 0 " 8'-2"6'-9 1/2"6'-2 1/2"11'-6"11'-8" 9' - 8 " 9' - 8 " F36 F40 F40 F40 F36 F24 [XX]F36 F36 F36 F30F26[XX] F36 SLAB F36 F36F24F24F24 F36 [XX][XX] 4' - 0 " 40 ' - 0 " [642'-4"] [642'-4"] [642'-4"] [640'] [-3'-0"] [-3'-0"] [640'][640'] [640'] FT G ( T Y P ) 1' - 8 " C O N C 13 5 . 0 0 ° 135.00 ° FND WALL 8" CONC FTG (TYP) 1'-8" CONC [640'] [640'] [640'] [640'] [640'] [640'] T/WALL = 645'-4" (TYP)T/WALL= 650'10 ' - 0 " 30'- 0 " 10'-0" 12'-0" T/WALL= 650' T/WALL = 645'-4" T/WALL @ DR OPNG = 650' [640'] T/WALL = 644'T/WALL = 644' T/WALL @ OPNG = 642'-8" T/WALL = 644'-4" (TYP) T/WALL = 645'-4" (TYP) [6 4 0 ' ] [640'][640'] [6 4 0 ' ] BEARING POCKET FOR SIMPSON STRONG TIE TYP GLB5D BEAM SEAT SUPPORTING (3) 16" LVL'S. [XX] FOUNDATION SYMBOLS KEY: INDICATES LOCATION OF CONTRACTION JOINTS. SEE TYPICAL SLAB DETAIL. INDICATES FOUNDATION WALL STRIP FOOTING INDICATES SPREAD FOOTING & CONCRETE PIER. INDICATES TYP CONC FND WALL INDICATES TYP SHELF IN CONCRETE FOUNDATION WALL PX FX [XXX'-XX"] (XXX'-X") INDICATES PIER TYPE. INDICATES TOP OF PIER ELEVATION. INDICATES SPREAD FOOTING TYPE. INDICATES TOP OF SPREAD FOOTING ELELVATION. [+/-0'-0"] INDICATES TOP/FTG ELEVATION FROM DATUM. [-3' -0" ] [-4' -0" ] TOP/FTG ELEVATOIN (HIGH SIDE) TOP/FTG ELEVATION (LOW SIDE) INDICATES ELEVATION CJ INDICATES GRADE ELEVATIONXXXX.XX' ALLOWABLE SOIL BEARING PRESSURE (PSF) CONCRETE COMPRESSIVE STRENGTH (PSI) REINFORCEMENT YIELD STRENGTH (GRADE 60) (KSI) 2000 3000 60 FOOTING MARK F26 2'-2" X 2'-2" X 10" FOOTING SIZE LEGTH X WIDTH X DEPTH REINFORCING BOTTOM SHORT TOP LONG (3) #4 (3) #4 SHORT LONG N/A N/A FOOTING SCHEDULE F30 2'-6" X 2'-6" X 10"(3) #4 (3) #4 F24 2'-0" X 2'-0" X 10"(3) #4 (3) #4 N/A N/A F40 3'-4" X 3'-4" X 10"(4) #4 (4) #4 F36 3'-0" X 3'-0" X 10"(4) #4 (4) #4 N/A N/A N/A N/A N/A N/A DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 213 East Seneca Street Ithaca, New York 14850 www.ElwynPalmer.com 607.272.5060 Elwyn Palmer& CONSULTING ENGINEERS, PLLC "Unauthorized Alteration or Addition To Plans Bearing a Licensed Engineer's or Architect's Seal is a Violation of Section 7209 of the New York State Education Law." S100 FOUNDATION PLAN 2021.10.20 2019002 Author 21 1 S u n s e t D r i v e CO N S T R U C T I O N D O C U M E N T S RE S I D E N C E 3/16" = 1'-0"1 FOUNDATION PLAN 1. DATUM ELEVATION (0") AT FIRST FLOOR EQUALS SITE ELEVATION (XXX'). 2. ELEVATIONS NOTED ARE WITH RESPECT TO DATUM ELEVATION. 3. TOP OF PIER ELEVATION = (-8") (@ STEEL COLUMNS) TYPICAL UNLESS NOTED OTHERWISE AS (+X'-XX") 4. TOP OF FOOTING ELEVATION = AS SHOWN ON DRAWINGS AS [-X'-XX"] 5. Px INDICATES PIER TYPE. SEE S301 FOR PIER PLAN DETAILS. 6. SEE S300 FOR TYPICAL SLAB DETAILS. 7. SEE S500 FOR COLUMN SCHEDULE. 8. SEE S300 FOR PIER PLAN DETAILS. 9. SEE S300 FOR BASE PLATE DETAILS. 10. SEE S001 FOR CONCRETE AND MASONRY REINFORCING LAP SCHEDULES. 11. PROVIDE (2) #4 x4'-0" LONG DIAGONAL AT SLAB REENTRANT CORNERS. 12. REFERENCE S500 FOR SHEARWALL SCHEDULE AND DETAILS.