Loading...
HomeMy WebLinkAboutSPR-Document408 E. Upland Road Office Building Site Plan Review Application January 14, 2022 Pg. 2 THIS PAGE INTENTIONALLY LEFT BLANK Pg. 3 TWM - A Fisher Associates Landscape Architecture Studio Fisher Associates, P.E., L.S., L.A., D.P.C. 1001 West Seneca Street, Suite 201 Ithaca, New York 14850 ph: 607.277.1400 www.twm.la | www.fisherassoc.com January 14, 2022 Brent Cross Village of Cayuga Heights Marcham Hall 836 Hanshaw Road Ithaca, NY 14850 RREE:: 440088 EE.. UUppllaanndd RRooaadd OOffffiiccee BBuuiillddiinngg Dear Brent and Members of the Planning Board, Attached please find SEQR and site plan review materials for the proposed 408 E. Upland Office Road Building. Located on a half-acre sized parcel along East Upland Road, the existing site consists of a single story 5,500 SF building in approximately the center of the parcel, with parking and driveway around the north, west, and south of the building. Areas of small shrub plantings, trees, and lawn are on the site as well. The proposed project includes the removal of the existing building and parking, to be replaced with a new 5,500 SF single story building and parking lot. The proposed building consists of two tenant spaces, one of which will serve as additional office space for Sciarraba Walker & Company, whose offices are located on the parcel to the north,410 East Upland Road. The second space will be leasable office space. A current tenant for the second space is not defined yet, however the space intends to attract a professional business tenant. Adjacent parcel uses include commercial to the north and west, and residential to the south of the site. A vegetative buffer in addition to the existing wood fence are proposed along the south side for privacy and separation from the adjacent residence. Proposed stormwater management practices on site consist of a rain garden as well as a below-grade alternative pre- manufactured hydrodynamic unit to provide water quality treatment of runoff from the sidewalk and parking area north of the new building. In this submission you will find the Village’s Review Application, Short Environmental Assessment Forms (SEAF) a detailed project narrative, illustrated site plan, and exterior building perspectives. An 11 x 17 drawing set depicting the proposed work is also included. The technical drawing set includes: C000 Survey Map C100 Civil Legend and Notes C101 Existing Site Conditions Plan C102 Site Utility Demolition Plan C201 Site Utility Plan C202 Erosion and Sediment Control Plan C301 Details C302 Details L101 Site Demolition Plan L201 Site Layout and Materials Plan L301 Site Grading Plan L401 Site Planting Plan L402 Site Mulch and Soils Plan L501 Site Details A101 First Floor Plan A105 Roof Plan A201 Exterior Elevations A301 Building Section In addition to site plan approval, this project will require a zoning variance for side, front, and rear yard setbacks, as well as a Special Permit due to the interior floor area of the building exceeding 5,000 SF. Thank you for your review of this project. If you have any questions or require further information, please do not hesitate to call. At your January 24 meeting, we are hoping to receive action on the following items: declaration of lead agency, set public hearing date, and referral to the zoning board for the variance and special permit. Sincerely, Lauren E. Butts, RLA, ASLA TWM - A Fisher Associates Landscape Architecture Studio Fisher Associates, P.E., L.S., L.A., D.P.C. 1001 West Seneca Street, Suite 201 Ithaca, New York 14850 ph: 607.277.1400 www.twm.la | www.fisherassoc.com January 14, 2022 Brent Cross Village of Cayuga Heights Marcham Hall 836 Hanshaw Road Ithaca, NY 14850 RREE:: 440088 EE.. UUppllaanndd RRooaadd OOffffiiccee BBuuiillddiinngg Dear Brent and Members of the Planning Board, Attached please find SEQR and site plan review materials for the proposed 408 E. Upland Office Road Building. Located on a half-acre sized parcel along East Upland Road, the existing site consists of a single story 5,500 SF building in approximately the center of the parcel, with parking and driveway around the north, west, and south of the building. Areas of small shrub plantings, trees, and lawn are on the site as well. The proposed project includes the removal of the existing building and parking, to be replaced with a new 5,500 SF single story building and parking lot. The proposed building consists of two tenant spaces, one of which will serve as additional office space for Sciarraba Walker & Company, whose offices are located on the parcel to the north,410 East Upland Road. The second space will be leasable office space. A current tenant for the second space is not defined yet, however the space intends to attract a professional business tenant. Adjacent parcel uses include commercial to the north and west, and residential to the south of the site. A vegetative buffer in addition to the existing wood fence are proposed along the south side for privacy and separation from the adjacent residence. Proposed stormwater management practices on site consist of a rain garden as well as a below-grade alternative pre- manufactured hydrodynamic unit to provide water quality treatment of runoff from the sidewalk and parking area north of the new building. In this submission you will find the Village’s Review Application, Short Environmental Assessment Forms (SEAF) a detailed project narrative, illustrated site plan, and exterior building perspectives. An 11 x 17 drawing set depicting the proposed work is also included. The technical drawing set includes: C000 Survey Map C100 Civil Legend and Notes C101 Existing Site Conditions Plan C102 Site Utility Demolition Plan C201 Site Utility Plan C202 Erosion and Sediment Control Plan C301 Details C302 Details L101 Site Demolition Plan L201 Site Layout and Materials Plan L301 Site Grading Plan L401 Site Planting Plan L402 Site Mulch and Soils Plan L501 Site Details A101 First Floor Plan A105 Roof Plan A201 Exterior Elevations A301 Building Section In addition to site plan approval, this project will require a zoning variance for side, front, and rear yard setbacks, as well as a Special Permit due to the interior floor area of the building exceeding 5,000 SF. Thank you for your review of this project. If you have any questions or require further information, please do not hesitate to call. At your January 24 meeting, we are hoping to receive action on the following items: declaration of lead agency, set public hearing date, and referral to the zoning board for the variance and special permit. Sincerely, Lauren E. Butts, RLA, ASLA Landscape Architect I Pg. 4 THIS PAGE INTENTIONALLY LEFT BLANK Pg. 5 Pg. 6 X X X X 408 East Upland Road Ithaca, NY 14850 1001 West Seneca St. Ste 201 Ithaca NY 14850 (607)210-8339 408 Upland Road LLC 01/14/22 TWM, A Fisher Associates Landscape Architecture Studio 408 Upland Road Office Building The existing building at 408 East Upland Road will be removed to accommodate a new 5,500 SF single story multi-tenant office building. The building will be contextual, respecting the scale of the residential properties, and will accommodate two tenants. Sciarabba Walker will be one of the tenants. The other tenant is anticipated to a professional business. Site work will consist of grading for a new parking lot, stormwater management, new plantings, as well as a wood fence and vegetative buffer screen. McPherson Builders, Inc.129 West Falls St. Ithaca, NY 14850 (607)273-2373 Pg. 7Page 1 of 3 Short Environmental Assessment Form Part 1 -Project Information Instructions for Completing Part 1 – Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Part 1 –Project and Sponsor Information Name of Action or Project: Project Location (describe, and attach a location map): Brief Description of Proposed Action: Name of Applicant or Sponsor:Telephone: E-Mail: Address: City/PO:State:Zip Code: 1.Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, administrative rule, or regulation? If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that may be affected in the municipality and proceed to Part 2. If no, continue to question 2. NO YES 2.Does the proposed action require a permit, approval or funding from any other government Agency? If Yes, list agency(s) name and permit or approval:NO YES 3.a. Total acreage of the site of the proposed action? __________ acres b. Total acreage to be physically disturbed? __________ acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor? __________ acres 4.Check all land uses that occur on,are adjoining or near the proposed action: Rural (non-agriculture) Industrial Commercial Residential (suburban) Aquatic Other(Specify):Agriculture □ Urban □ Forest SEAF 2019 Parkland 408 E.Upland Road Office Building 408 East Upland Road Ithaca,NY 14850 The existing building at 408 East Upland Road will be removed to accommodate a new 5,500 SF single story multi-tenant office building.The building is being designed to be carbon-neutral and net-zero,with anticipation of photovoltaic panel installation at time of construction.The building will be contextual,respecting the scale of the residential properties that border two sides of the site,while creating contemporary space to attract business tenants.The building is designed to accommodate two tenants.Sciarabba Walker will be one of the tenants.The other tenant,not yet under contract,is anticipated to a professional business.Site work will consist of grading for a new parking lot,stormwater management,new plantings,as well as a wood fence and vegetative buffer screen. Lauren Butts,TWM A Fisher Associates Landscape Architecture Studio 607-210-8339 leb@twm.la 1001 West Seneca St.Suite 201 Ithaca NY 14850 Village of Cayuga Heights Zoning Board (setback variance and special use permit) .5 .5 .5 Pg. 8Page 2 of 3 5.Is the proposed action, a.A permitted use under the zoning regulations? b.Consistent with the adopted comprehensive plan? NO YES N/A 6.Is the proposed action consistent with the predominant character of the existing built or natural landscape?NO YES 7.Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? If Yes, identify: ________________________________________________________________________________ NO YES 8.a.Will the proposed action result in a substantial increase in traffic above present levels? b.Are public transportation services available at or near the site of the proposed action? c.Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed action? NO YES 9.Does the proposed action meet or exceed the state energy code requirements? If the proposed action will exceed requirements, describe design features and technologies: _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 10.Will the proposed action connect to an existing public/private water supply? If No, describe method for providing potable water: _________________________________________ _____________________________________________________________________________________________ NO YES 11.Will the proposed action connect to existing wastewater utilities? If No, describe method for providing wastewater treatment: ______________________________________ _____________________________________________________________________________________________ NO YES archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory? NO YES 13.a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies regulated by a federal, state or local agency? b.Would the proposed action physically alter, or encroach into, any existing wetland or waterbody? If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: _____________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 12.a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district which is listed on the National or State Register of Historic Places, or that has been determined by the Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? b.Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for The building is designed to be net-zero ready with photovoltaic panels anticipated to be installed at the time of construction.Heating and cooling will be provided by either air source heat pumps or ground source heat pumps.Lighting will be LED. Pg. 9Page 3 of 3 14.Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply: □Shoreline □ Forest Agricultural/grasslands Early mid-successional Wetland □ Urban Suburban 15.Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or Federal government as threatened or endangered?NO YES 16.Is the project site located in the 100-year flood plan?NO YES 17.Will the proposed action create storm water discharge, either from point or non-point sources? If Yes, a.Will storm water discharges flow to adjacent properties? b.Will storm water discharges be directed to established conveyance systems (runoff and storm drains)? If Yes, briefly describe: _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 18.Does the proposed action include construction or other activities that would result in the impoundment of water or other liquids (e.g., retention pond,waste lagoon, dam)? If Yes, explain the purpose and size of the impoundment:______________________________________________ ____________________________________________________________________________________________ _ NO YES 19.Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste management facility? If Yes, describe: _______________________________________________________________________________ _____________________________________________________________________________________________ NO YES 20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or completed) for hazardous waste? If Yes, describe: _______________________________________________________________________________ _____________________________________________________________________________________________ NO YES I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Date:_____________________Applicant/sponsor/name:____________________________________________________ __________________________ Signature: _____________________________________________________Title:__________________________________ Discharge of runoff will be to existing open drainage channel. No change in drainage patterns are proposed. Stormwater management is subject to review by Village of Cayuga Heights which is a registered MS4. Lauren Butts 01/14/22 Landscape Architect I PRINT FORM Pg. 10 THIS PAGE INTENTIONALLY LEFT BLANK Pg. 11 Project Narrative Pg. 12 EXISTING SITE The existing site consists of a single story, approximately 3,600 SF building located approximately in the center of the site. Areas of lawn and small shrub plantings surround the building. Two driveways border the north and south edges of the site, providing access with two curb cuts on East Upland Road, and connect along the west side of the site where parking is located. Several parallel parking spots are also located along the north and south driveways. Approximately 20 parking spaces are found on site. The site gently slopes from the southeast to the northwest corner of the site. A small drainage channel exists in the northwest corner of the site. Approximately five feet of grade change occurs across the site. The site is zoned for commercial use. Adjacent parcel use consists of commercial to the north and east, with residential to the west and south. The parcel to the north, 410 East Upland Road is owned by Sciarraba Walker Corporation. Buffers between the adjacent parcels consist of tall trees and shrubs on the other side of the property line to the west, an area of lawn to the north, and a wood fence that runs along the south property line adjacent to the residence. N Ea s t U p l a n d R o a d Existing 408 E. Upland Building Existing Asphalt Driveway and Parking Residential Parcel Scale: 1:10 SITE LAYOUT PLAN1 DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 10 / 2 7 / 2 0 2 1 4 : 5 9 : 5 5 P M 10/29/21 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 JVB/LEB REVISION SCHEDULE NAME DATE L201 SITE LAYOUT AND MATERIALS PLAN GENERAL SHEET NOTES - LAYOUT LAYOUT NOTES: 1.GENERAL CONTRACTOR SHALL NOTIFY ALL UTILITY OWNERS HAVING UNDERGROUND UTILITIES ON SITE PRIOR TO EXCAVATION. 2.CONTRACTOR SHALL CONTACT UTILITY LOCATING COMPANY AND LOCATE ALL UTILITIES PRIOR TO ANYEXCAVATION.3.SEE CIVIL AND ELECTRICAL DRAWINGS FOR LAYOUT OF UNDERGROUND UTILITIES AND SITE LIGHTING. 4.INSTALL EXPANSION JOINTS EVERY 30' MAX IN CONCRETE PAVEMENT AND IN AREAS WHERECONCRETE ABUTS CURBS OR OTHER FIXED OBJECTS.5.CONCRETE SCORING TO BE EQUALLY SPACED UNLESS OTHERWISE NOTED 6.VERIFY DIMENSIONS AND ACCEPT CONDITIONS BEFORE PROCEEDING WITH WORK. REPORT ANYDISCREPANCIES TO LANDSCAPE ARCHITECT BEFORE PROCEEDING.7.DO NOT SCALE FROM MEASURING DRAWINGS. 8.WALKS, DRIVES, CURBS AND PARKING TO BE STAKED OUT IN THE FIELD BY A LICENSED SURVEYOR.9.LAYOUT DIMENSIONS AND RADII ARE TO EDGE OF CONCRETE WALKS AND FACE OF CURB.10.ALL PAVEMENT RADII ARE 5' UNLESS OTHERWISE NOTED ON PLAN. KEY MATERIAL DETAIL HEAVY DUTY ASPHALT PAVEMENT MEDIUM DUTY CONCRETE PAVING STONE DUST PAVING BOARD FENCE CONTRACT LIMIT LINE A9 L501 A7 L501 A1 L501 ## L501 410 E. Upland Road (Sciarraba Walker Offices - Commercial) Re s i d e n t i a l P a r c e l Residential Parcel 0 10 205Exiting Site Plan Pg. 13 BUILDING Project Needs And Goals The current Sciarabba Walker Corporation anticipates outgrowing their current office space at 410 East Upland Road in Ithaca, NY in the near future. To be prepared for this growth the adjacent site at 408 East Upland was purchased. On the site there is currently a one-story building that will be demolished to accommodate the construction of a new building. The Client has asked HOLT to design a 5,500-sf single story office building that will be divided into two spaces. One space will host Scriabba Walker, and the other will be leasable space for a new tenant. The new office building will sit on the southwest corner of the site to optimize building square footage for leasable space and parking. Proposed Program The program includes a shared vestibule and lobby space for the two tenants, 3,000 sf of leasable space, two gender neutral bathrooms, two drinking fountains, storage closet provided for leasable space, shared janitorial closet, shared mechanical space, and Scriabba Walker open and private offices. The second tenant is not yet defined but is anticipated to be a professional business. Building Design The building is a simple 5,500 sf rectangular building with a single slope roof. The sloped roof is designed to maximize daylighting on the north side of the building, while also mitigating sun exposure on the south. This roof was also designed with the intent to house photovoltaic panels, as the building is designed to be net- zero. The sloped roof system wraps down the south façade to create a strong anchor on the backside of the building which holds private office and mechanical space. Materials were chosen to emphasize this simple diagrammatic expression. Building materials include: •Standing seam metal roof that folds down the south façade – creating a clean solid edge condition. •Linear wood panel siding along half of the east and west façade as a response to the private offices, and mechanical space located in the southern side of the building. •Storefront windows open to the North and wraps along each side of the east and west, engaging the urban edge. •Precast concrete or stone base that anchors the storefront windows and entrance to create a connection to the ground. Mechanical Systems The project participated in the Tompkins County Building Energy Advisors program to get recommendations on energy saving measures for this specific building. The building will be fully electrified (fossil fuel free) for all mechanical systems. Additionally the building is designed to be net-zero, with the installation of photovoltaic panels at the time of construction. The space will be heated and cooled with either air source heat pumps or ground source heat pumps and a dedicated outdoor air system will provide occupant control of the ventilation. The domestic hot water will be served with either a hybrid heat pump water heater or an electric resistance tanked water heater. Lighting will all be LED and the project includes vehicle charging stations. The project will comply with the Ithaca Energy Code Supplement. Pg. 14 Proposed Building Renderings View of northeast corner of proposed building View of northwest corner of the building Pg. 15 View of southeast corner of building and buffer at southern property line View of building entrance and exterior of leasable space Pg. 16 SITEWORK The scope of the sitework for this project will include both demolition of the existing paving and building on site, as well as site improvements. Site improvements include a new asphalt parking lot, concrete walkways with granite curbs, stormwater management practices, as well as site plantings which include plans for a vegetative buffer. Circulation Vehicular: 408 East Upland is currently accessed by two driveways along East Upland Road, with the driveway wrapping around the south, west, and north side of the building located approximately in the center of the site (see existing site plan ). The proposed project removes the southern driveway, locating the driveway and parking lot on the north side of the site and building to the south. This orientation removes vehicular traffic away from the residential neighbor to the south. Pedestrian: Concrete walkways are provided around the west, north, and east sides of the proposed building. The walkway along the north of the building provides pedestrian access from the parking lot to the building entrance. Walkways along the east and the west of the building provide emergency egress from the two interior office spaces. A stone dust pathway connection in the parking lot is proposed to connect to the existing Sciarraba Walker property to the north (410 East Upland Road). It is anticipated that some Sciarraba Walker employees will regularly need to travel between the 408 and 410 properties. Currently a small gravel path connection exists which would be relocated and replaced by the proposed stone dust path. The proposed path connects from the edge of the 410 parking lot and is aligned with the 408 building entrance. Where adjacent to the parking lot, concrete walkways and the stone dust path are separated by a granite curb to ensure pedestrian safety and separation from vehicular traffic. Curb ramps are provided and grades of less than 2% on the walkways ensure ADA accessibility. Parking and Traffic: Per zoning, one parking space is required for every 200 SF of leasable and occupied office space. The proposed building contains approximately 4,950 SF of total leasable office space, which would require 25 parking spaces. The proposed parking lot provides 25 parking spaces, one of which is to be ADA accessible. All parking spaces, including the ADA parking space and adjacent access aisle, are nine feet wide and 18 feet long. The parking lot drive aisle is 24’ wide. Wheel stops will be provided along the south parking bays to prevent overhang onto walkway. An electric vehicle charging station will be provided in the northeast corner of the lot. Based on the proposed building use, as well as both the known tenant (Sciarraba Walker) and anticipated professional business as the second building tenant, a significant increase in traffic is not expected. Site Lighting and Signage The project will include exterior building lights and pole lights in the parking lot. Exterior building lights will be located above all building entrances/exits, as well as recessed in the roof overhang to help illuminate the parking lot. Additional pole lights will be between 18’-22’ in height and located on the north side of the parking lot to illuminate all driveways, parking aisles and parking stalls. Selected lighting fixtures will be dark sky compliant and shielded to prevent light trespassing. A new building sign in the front yard will replace the existing sign. The style and design of this signage is still to be determined but will conform to code. Pg. 17 Site Buffer and Vegetation Areas within the project will be landscaped with hardy deciduous shade trees, evergreens, ornamental trees and shrub plantings. Per code, site perimeters adjacent to parcels of a different zoning use must have a vegetative screen. For the 408 East Upland project site, parcels to the south and west are zoned residential, therefore requiring a vegetative buffer to be provided. The south edge of the project will utilize the existing wood fence and added plantings to create a vegetative screen. Proposed plantings will include woody shrubs and ornamental grasses, as well as deciduous and evergreen trees. Input from the adjacent residential neighbor at 406 East Upland Road will inform final planting selections. Shrub plantings, in addition to the significant mature vegetation on the adjacent parcel, will create a vegetative buffer along the west edge. Additional plantings will be provided in the front yard of the parcel and in the proposed bioretention filter practice (rain garden) to the east of the building. Additional tree and shrub plantings are proposed in the northeast quadrant of the site. Site Materials All vehicular paving is to be heavy duty asphalt, with granite curb where indicated. The walkways around the building are proposed as medium duty concrete. N Ea s t U p l a n d R o a d 410 Upland Road 408 Upland Proposed Building 5,500 SF Asphalt Parking Lot Rain Garden Sign Property Line, Typ. Stone Dust Path Sub-Surface Hydrodynamic Separator Location Vegetative Buffer Existing Wood Fence Concrete Walkway Electric Vehicle Charging Station Site Light, Typ. 0 10 205Proposed Site Plan Pg. 18 STORMWATER Stormwater Drainage The site slopes down generally from the southeast to the northwest and discharges to an open channel near the northwest corner of the site. Roof runoff from the existing flat roof is piped to the open channel. In general, the runoff from the site pavements and landscaped areas flows overland to a swale along the north edge of the site or directly to the open channel noted above. The existing storm piping from the building will be removed or cut, cap and abandoned in-place. There are no existing stormwater management practices on the site. Runoff from the new building will be collected with interior roof leader piping discharging above grade on the east face of building near the southeast corner of the building. The roof runoff will drain to a proposed bioretention filter (rain garden) located in the front landscaped area of the site. Runoff from the front lawn as well as pavements in the street and the proposed entrance drive will also drain to the rain garden. Runoff from the walk and parking pavements north of the new building will be collected by drainage inlets located at the north curb line of the new parking area. Runoff from the rain garden and the drainage inlets will be piped to the open channel at the northeast corner of the site. The outfall of the storm piping will be equipped with rip-rap outlet protection at the outfall to the channel. Relatively minor areas of the site will drain to the existing swale along the north edge of the site or will sheet drain away from the building to the west. Stormwater Management The site disturbance for the project is estimated to be approximately 0.5 acres, and preparation of a Full Stormwater Pollution Prevention Plan (Full SWPPP) and submission of a Notice of Intent for permit coverage under the NYSDEC General Permit for Construction Activities (GP-0-20-001) will not be required. The project will however provide temporary erosion and sediment control practices to prevent sediment from leaving the site during construction, as well as permanent stormwater practices to manage post-construction runoff. The permanent practices will provide water quality treatment of the runoff and will also reduce the peak rates of runoff leaving the site. Two separate post-construction practices are proposed. The first, as noted above, will be a rain garden in the front lawn that will provide quality treatment of runoff from the roof of the new building, the entrance drive and areas within the adjacent street. The control structure for the rain garden will be equipped with a 24- inch wide weir to detain runoff within the practice and attenuate peak discharge rates of runoff from the site. A second practice will be a below-grade alternative pre-manufactured hydrodynamic unit to provide water quality treatment of runoff from the sidewalk and parking area north of the new building. A standard practice at this location is not possible given the limited vertical space at the outfall to the existing open channel. The total water quality treatment provided by the two practices is more than double the amount required by the New York State design standards. Calculations and site data related to the site and the proposed stormwater management practices are attached. Pg. 19 SITE UTILITIES Water Service The existing water service to the site is provided by a 1-inch copper service line connected to a 6-inch Village water main in the street. The project will remove the existing service between the building and the curb valve located at the street line. To serve the new building, the project will install new or salvaged 1-inch copper piping between the curb valve and the new building. The service will enter into a mechanical space on the south side of the new building where the water meter assembly will be located. The Village main is supplied through the Christopher Circle storage tank and normal operating pressures at the site are expected to range between approximately 66 and 72 psi. Water use in the new building will be relatively modest and no appreciable change from the existing building is expected. Sanitary Service The existing sanitary service lateral is 4-inch in size and connects to an 8-inch Village sewer main in the street. The existing lateral will be disconnected at the main by Village DPW staff or by the project as directed by the Village. Reuse of the existing service lateral for the new building is not expected to be possible given the lower floor elevation of the new building. The new 4-inch PVC service lateral will exit the building at the east wall and will be equipped with a house trap outside the building. A cleanout will be installed at the street line to demarcate the division between the Village and private piping. The connection to the Village main and the piping in the street will be installed by the Village or by the project as directed by the Village. Natural Gas The existing gas service and meter assembly will be disconnected and purged by NYSEG, and the existing gas piping on the site removed by the project. Equipment in the new building will be electric and no new gas service is proposed. Electric and Telecommunications The existing electric and telecom utilities serving the existing building is provided within below-grade conduit from an existing NYSEG utility pole located at the north edge of the site. The new building will be served in a similar fashion from this same pole. The existing conduits will be reused if possible or replaced and extended as necessary. Power to the new building is expected to be supplied from the existing or a new pole-mounted transformer as determined by NYSEG. Pg. 20 ZONING CODE Setbacks The site is zoned commercial. In this zone, requirements for building setbacks states that “ buildings in the Commercial Zone shall be set back from property lines a minimum of 35 feet, said dimension to be measured at right angles to the property lines.” (§ 305-38. Building setbacks). Where the commercial zone abuts another zoning district, setback distance will be contingent on building height. In the front yard, setback distances may equal the maximum height of the building and side and rear yard setbacks may equal one and a half times the maximum height, but for any setback no less than 35 feet is required. The maximum height of the roof is 15 feet, which under existing zoning setbacks would require the building to be setback 35 feet on all sides of the building. (See existing building footprint and commercial zone setbacks diagram) This project will seek variances for side (south), front, and rear yard setbacks. The building has been sited along the south of the property in order to move disruptive vehicular traffic away from the adjacent residential home. This building placement has also eliminated a curb cut from East Upland Road to create a single driveway entrance to the site. A 10’ buffer space has been created between the existing (to remain) wood fence along the property line and the back of the proposed building. This space will be planted as a vegetative buffer for added privacy. Additionally, due to the site grading and proposed building elevation, most of the fence is at a slightly higher elevation than the building FFE. Therefore, in certain locations along the site boundary the four-foot-tall fence is providing the screening benefit or a five or six foot tall fence (see section of south yard buffer). Based on the dimensions required to create a building of a desirable size that also allows space on the site to provide enough parking, the siting of the building falls within both the front and rear yard setbacks. The rear of the 408 site abuts the rear of an adjacent residential property that is already separated by significant mature vegetation. The building is sited no less than approximately 13’ at any point from the rear property boundary, and will have a planted buffer to supplement the existing vegetative buffer on the adjacent property. In the front yard, a small portion of the east face of the building encroaches into the setback by approximately five feet. The remaining east face of the building is set further back than the required 35 feet. Please see the proposed building footprint and commercial zone setbacks diagram for reference. Special Use While the use of the building is permitted within the commercial zone, a special use permit will be required due to the square footage of the building exceeding 5,000 SF. As stated in § 305-35 of the code in regards to permitted uses in the commercial zone subject to the approval of the Village Planning Board, “any of the uses set forth in § 305-34 above as being permitted as of right in which case the interior floor area for such use exceeds 5,000 square feet but does not exceed 10,000 square feet.” It should be noted that the lot coverage of the proposed project is 22.5% which is below the 25% maximum coverage allowed. Section of South Yard Buffer 10’ 4’ Approx. 897.5 FFE 895.64 Existing Wood Fence Proposed 408 E. Upland Building Residence to the South Pg. 21 EXISTING CONDITIONS Fi l e : T: \ P R O J E C T S \ 4 0 8 U p l a n d R d . F e a s i b i l i t y 2 1 0 0 8 \ G R A P H I C S \ d i a g r a m s \ S P R S e t b a c k D i a g r a m . d w g Plo t D a t e : 1/1 2 / 2 0 2 2 ######## #### #### ### ### 2/6/2020 1:10 N PROPERTY LINE 35’ SETBACK NO PARKING ZONE VEGETATIVE BUFFER ZONE 0 10 205 N LOT S I Z E 2 4 , 3 7 0 . 1 5 s q . f t . ( 0 . 5 A c r e s ) PROPOSED CONDITIONS Fil e : T: \ P R O J E C T S \ 4 0 8 U p l a n d R d . F e a s i b i l i t y 2 1 0 0 8 \ A C A D \ T W M L A B A S E 2 1 0 0 8 . d w g Pl o t D a t e : 1/ 1 2 / 2 0 2 2 ######## #### #### ### ### 2/6/2020 00 10'20' 1:10 N PROPERTY LINE 35’ SETBACK NO PARKING ZONE VEGETATIVE BUFFER ZONE 0 10 205 N LO T S I Z E 2 4 , 3 7 0 . 1 5 s q . f t . ( 0 . 5 A c r e s ) EXISTING CONDITIONS Fi l e : T: \ P R O J E C T S \ 4 0 8 U p l a n d R d . F e a s i b i l i t y 2 1 0 0 8 \ A C A D \ 2 1 0 0 8 T W M L A D R A F T C O N C E P T . d w g Pl o t D a t e : 3/ 3 1 / 2 0 2 1 ######## #### #### ### ### 2/6/2020 1:10 N PROPERTY LINE 35’ SETBACK NO PARKING ZONE VEGETATIVE BUFFER ZONE LOT S I Z E 2 4 , 3 7 0 . 1 5 s q . f t . ( 0 . 5 A c r e s ) EXISTING CONDITIONS Fil e : T: \ P R O J E C T S \ 4 0 8 U p l a n d R d . F e a s i b i l i t y 2 1 0 0 8 \ A C A D \ 2 1 0 0 8 T W M L A D R A F T C O N C E P T . d w g Plo t D a t e : 3/ 3 1 / 2 0 2 1 ######## #### #### ### ### 2/6/2020 1:10 N PROPERTY LINE 35’ SETBACK NO PARKING ZONE VEGETATIVE BUFFER ZONE LO T S I Z E 2 4 , 3 7 0 . 1 5 s q . f t . ( 0 . 5 A c r e s ) Existing building footprint and commercial zone setbacks Proposed building footprint and site with commercial zone setbacks Pg. 22 Technical Drawings C000 Survey Map C100 Civil Legend and Notes C101 Existing Site Conditions Plan C102 Site Utility Demolition Plan C201 Site Utility Plan C202 Erosion and Sediment Control Plan C301 Details C302 Details L101 Site Demolition Plan L201 Site Layout Materials Plan L301 Site Grading Plan L401 Site Planting Plan L402 Site Mulch and Soils Plan L501 Site Details A101 First Floor Plan A105 Roof Plan A201 Exterior Elevations A301 Building Sections THIS PAGE INTENTIONALLY LEFT BLANK DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 SURVEY MAP C000 THIS PAGE INTENTIONALLY LEFT BLANK DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 CIVIL LEGEND AND NOTES C100 THIS PAGE INTENTIONALLY LEFT BLANK DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 EXISTING SITE CONDITIONS C101 THIS PAGE INTENTIONALLY LEFT BLANK DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 SITE UTILITY DEMOLITION PLAN C102 THIS PAGE INTENTIONALLY LEFT BLANK +FFE 895.64 TR 896.00 BC 895.50 TR 896.00 BC 895.50 RIM 893.50 2% 89 6 . 0 0 898 . 0 0 897 . 0 0 TC 895.86 BC 895.36 TC 896.0 BC 895.5 893. 0 0 RIM 893.50 EE 895.62 INV. 890.50 PAD 895.50 2%2% 2% 894. 0 0 895 . 0 0 2%2%2% 2%2% 2% 895.25895.25895.25 894.00 897 . 0 0 89 5 . 0 0 89 4 . 0 0 89 5 . 0 0 89 4 . 0 0 89 6 . 0 0 +FFE 895.64 EE 895.62 +FFE 895.64 EE 895.62 TR 896.12 BR 895.62 BR 895.74 BR 895.62 BR 895.74 TR 896.12 TC 895.5 BC 895.0 TC 894.7 BC 894.2 TC 894.2 BC 893.7 TC 895.8 BC 895.4 TC 895.9 BC 895.4 895.88 895.5 TC 896.4 BC 895.9 TC 894.5 BC 864.0 TC 894.7 BC 894.2 TR 894.54 BR 894.34 TR 894.54 BR 894.34 RIM 894.3 895.8 896.12896.0 895.8 895.5 MATCH EXISTING GRADE MATCH EXISTING GRADE MATCH EXISTING GRADE 895.26895.26895.26 2% DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 SITE UTILITY PLAN C201 THIS PAGE INTENTIONALLY LEFT BLANK +FFE 895.64 TR 896.00 BC 895.50 TR 896.00 BC 895.50 RIM 893.50 2% 89 6 . 0 0 898 . 0 0 897 . 0 0 TC 895.86 BC 895.36 TC 896.0 BC 895.5 893. 0 0 RIM 893.50 EE 895.62 INV.890.50 PAD 895.50 2%2% 2% 894. 0 0 895 . 0 0 2%2%2% 2%2% 2% 895.25895.25895.25 894.00 897 . 0 0 89 5 . 0 0 89 4 . 0 0 89 5 . 0 0 89 4 . 0 0 89 6 . 0 0 +FFE 895.64 EE 895.62 +FFE 895.64 EE 895.62 TR 896.12 BR 895.62 BR 895.74 BR 895.62 BR 895.74 TR 896.12 TC 895.5 BC 895.0 TC 894.7 BC 894.2 TC 894.2 BC 893.7 TC 895.8 BC 895.4 TC 895.9 BC 895.4 895.88 895.5 TC 896.4 BC 895.9 TC 894.5 BC 864.0 TC 894.7 BC 894.2 TR 894.54 BR 894.34 TR 894.54 BR 894.34 RIM 894.3 895.8 896.12896.0 895.8 895.5 MATCH EXISTING GRADE MATCH EXISTING GRADE MATCH EXISTING GRADE 895.26895.26895.26 2% DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 EROSION & SEDIMENT CONTROL PLAN C202 THIS PAGE INTENTIONALLY LEFT BLANK DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 DETAILS C301 · · · THIS PAGE INTENTIONALLY LEFT BLANK DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 FLS REVISION SCHEDULE NAME DATE 01/12/22 E21-38 DETAILS C302 THIS PAGE INTENTIONALLY LEFT BLANK SIGN TO BE REMOVED BUILDING TO BE DEMOLISHED, SEE ARCHITECTURE VEGETATION TO BE REMOVED TREES TO BE REMOVED, TYP. UTILITY POLE TO REMAIN AND BE PROTECTED SEE CIVIL DRAWINGS WOOD POSTS TO BE REMOVED WOOD POSTS TO BE REMOVED WOOD FENCE TO REMAIN AND BE PROTECTED CONSTRUCTION GATE CONSTRUCTION FENCE Scale: 1:10 SITE DEMOLITION PLAN1 00 10'20' DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 10 / 2 7 / 2 0 2 1 4 : 5 9 : 5 5 P M 10/29/21 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 JVB/LEB REVISION SCHEDULE NAME DATE L101 DEMOLITION PLAN GENERAL SHEET NOTES - DEMOLITION 1.CONSTRUCTION FENCING TO BE INSTALLED AS NECESSARY TO PROTECT PEDESTRIANS, CONTROL VEHICULAR TRAFFIC AND PROTECT ON-SITE CONSTRUCTION MATERIALS. 2.CONTRACTOR TO PROVIDE TEMPORARY WALKWAYS AND TRAFFIC SIGNS TO PROTECT PEDESTRIANS 3.PROVIDE SEDIMENTATION CONTROLS AT ALL EXISTING CATCH BASINS AFFECTED BY NEW CONSTRUCTION. 4.PROTECT ALL SURFACE AND SUBSURFACE UTILITIES TO REMAIN DURING DEMOLITION WORK. SEE CIVIL PLANS. 5.ALL REMOVED/DEMOLISHED MATERIAL SHALL BECOME CONTRACTOR'S PROPERTY AND REMOVED FROM SITE, UNLESS NOTED OTHERWISE. OWNER TO RESERVE RIGHT OF FIRST REFUSAL ON ALL DEMOLISHED MATERIAL. 6.ALL TREE STUMPS ARE TO BE REMOVED COMPLETELY, ALONG WITH ALL ROOTS 6" AND LARGER. KEY MATERIAL DETAIL ASPHALT PAVING TO BE REMOVED REMOVE WALKWAYS AND WOOD DECK TO BUILDING VEGETATION TO BE REMOVED BUILDING TO BE DEMOLISHED, SEE ARCHITECTURE TREE TO BE REMOVED PROPERTY LINE CONSTRUCTION FENCE WOOD FENCE TO REMAIN AND BE PROTECTED CONTRACT LIMIT LINE THIS PAGE INTENTIONALLY LEFT BLANK STONE DUST PATH CONNECTION PROPOSED BUILDING 6. 0 0 ' 18 . 0 0 ' 24 . 0 0 ' 18 . 0 0 ' 9.00'9.00'9.00' TYP. 10 . 0 0 ' WHEEL STOP, TYP. 10.00' 5.00'5.00' SIGN. SIZE AND HEIGHT TO BE DETERMINED IN FUTURE PHASE 5.75' SITE LIGHT TYP (3) SEE ELECTRICAL ELECTRIC VEHICLE CHARGING STATION (2 VEHICLES). SEE ELECTRICAL 36 . 5 0 ' 10.00' 12 . 0 0 ' 44 . 0 0 ' A7 L501 MEDIUM DUTY CONCRETE WALKWAY A9 L501 HEAVY DUTY ASPHALT PAVING A2 L501 GRANITE CURB A5 L501 CONCRETE JOINTS, EQ. JOINT SPACING TYP 6.00'6.00' E7 L501 ADA PAVEMENT MARKINGS E5 L501 ADA PARKING SIGNAGE E9 L501 ADA CURB RAMP EQ . S P A C I N G T Y P . EQ. SPACING TYP.EQ. SPACING TYP. EQ . S P A C I N G T Y P . R13' R 2 3 . 0 0 ' R1.50 ' R1. 5 0 ' CATCH BASIN, TYP. SEE CIVIL DRAWINGS OUTLINE OF BASIN. SEE CIVIL EXISTING WOOD FENCE ALONG PROPERTY LINE TO REMAIN Scale: 1:10 SITE LAYOUT PLAN1 00 10'20' DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 10 / 2 7 / 2 0 2 1 4 : 5 9 : 5 5 P M 10/29/21 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 JVB/LEB REVISION SCHEDULE NAME DATE L201 SITE LAYOUT AND MATERIALS PLAN GENERAL SHEET NOTES - LAYOUT LAYOUT NOTES: 1.GENERAL CONTRACTOR SHALL NOTIFY ALL UTILITY OWNERS HAVING UNDERGROUND UTILITIES ON SITE PRIOR TO EXCAVATION. 2.CONTRACTOR SHALL CONTACT UTILITY LOCATING COMPANY AND LOCATE ALL UTILITIES PRIOR TO ANY EXCAVATION. 3.SEE CIVIL AND ELECTRICAL DRAWINGS FOR LAYOUT OF UNDERGROUND UTILITIES AND SITE LIGHTING. 4.INSTALL EXPANSION JOINTS EVERY 30' MAX IN CONCRETE PAVEMENT AND IN AREAS WHERE CONCRETE ABUTS CURBS OR OTHER FIXED OBJECTS. 5.CONCRETE SCORING TO BE EQUALLY SPACED UNLESS OTHERWISE NOTED 6.VERIFY DIMENSIONS AND ACCEPT CONDITIONS BEFORE PROCEEDING WITH WORK. REPORT ANY DISCREPANCIES TO LANDSCAPE ARCHITECT BEFORE PROCEEDING. 7.DO NOT SCALE FROM MEASURING DRAWINGS. 8.WALKS, DRIVES, CURBS AND PARKING TO BE STAKED OUT IN THE FIELD BY A LICENSED SURVEYOR. 9.LAYOUT DIMENSIONS AND RADII ARE TO EDGE OF CONCRETE WALKS AND FACE OF CURB. 10.ALL PAVEMENT RADII ARE 5' UNLESS OTHERWISE NOTED ON PLAN. A9 L501 A7 L501 A1 L501 KEY MATERIAL DETAIL HEAVY DUTY ASPHALT PAVEMENT MEDIUM DUTY CONCRETE PAVING STONE DUST PAVING EXISTING WOOD FENCE TO REMAIN CONTRACT LIMIT LINE PROPERTY LINE THIS PAGE INTENTIONALLY LEFT BLANK TR 896.00 BC 895.50 TR 896.00 BC 895.50 RIM893.50 2% 89 6 . 0 0 898 . 0 0 897 . 0 0 TC 895.86 BC 895.36 TC 896.0 BC 895.5 893. 0 0 RIM893.50 INV. 890.50 PAD 895.50 2% 894. 0 0 895 . 0 0 2%2%2%2%2% 895.25895.25895.25 894.00 897 . 0 0 89 5 . 0 0 89 4 . 0 0 89 3 . 0 0 89 5 . 0 0 89 4 . 0 0 89 3 . 0 0 896 . 0 0 BR 895.62 BR 895.62 TC 895.5 BC 895.0 TC 894.7 BC 894.2 TC 894.2 BC 893.7 TC 895.8 BC 895.4 TC 895.9 BC 895.4 895.88 895.5 TC 896.4 BC 895.9TC 894.5 BC 864.0 TC 894.7 BC 894.2 TR 894.54 BR 894.34 TR 894.54 BR 894.34 RIM 894.3 895.8 895.8 895.5 MATCH EXISTING GRADE MATCH EXISTING GRADE MATCH EXISTING GRADE 895.26895.26895.26 2% 2%EE 895.622% 2% +FFE 895.64 EE 895.62 +FFE 895.64 EE 895.62 TR 896.12 BR 895.74 BR 895.74 TR 896.12 896.12896.0 +FFE 895.64 Scale: 1:10 GRADING PLAN1 00 10'20' DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 10 / 2 7 / 2 0 2 1 4 : 5 9 : 5 5 P M 10/29/21 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 JVB/LEB REVISION SCHEDULE NAME DATE L301 GRADING PLAN EXISTING CONTOUR PROPOSED MAJOR CONTOUR PROPOSED CONTOUR PROPOSED SPOT ELEVATION BC = BOTTOM OF CURB TC = TOP OF CURB EXISTING SPOT ELEVATION TC 389.30BC 388.80 HP = HIGH POINT RIM = RIM ELEVATION STORM INLET (SEE CIVIL) STORM CULVERT (SEE CIVIL) TW = TOP OF WALL BW = BOTTOM OF WALL HPS = HIGH POINT OF SWALE BS = BOTTOM OF STAIR TS = TOP OF STAIR FFE = FINISH FLOOR ELEVATION EE = ENTRY ELEVATION 1.PROPOSED LAYOUT BASED ON SURVEY COMPLETED BY T.G. MILLER, P.C. 2.GENERAL CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES HAVING UNDERGROUND UTILITIES ON SITE OR IN RIGHT-OF-WAY PRIOR TO EXCAVATION. CONTRACTOR SHALL CONTACT UTILITY LOCATING COMPANY AND LOCATE ALL UTILITIES PRIOR TO GRADING START. 3.SITE GRADING SHALL NOT PROCEED UNTIL EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 4.GRADING AROUND EXISTING TREES TO BE MINIMIZED. 5.MINIMIZE IMPACT TO EXISTING, REMAINING LANDSCAPE WHILE EXCAVATING. GREAT CARE IS TO BE TAKEN TO AVOID DISTURBING ROOTS OF EXISTING TREES. HAND EXCAVATION AND/OR EXCAVATION WITH AN AIR SPADE WILL BE REQUIRED WHERE EXISTING TREE ROOTS ARE PRESENT. 6.MATCH EXISTING GRADE AT ALL EDGES WHERE PROJECT WORK MEETS EXISTING SITE. 7.SEE CIVIL DRAWINGS FOR PROPOSED UTILITIES. GENERAL SHEET NOTES - GRADING THIS PAGE INTENTIONALLY LEFT BLANK 1 ACf 1 Plvp 1 ACab 1 ACab 1 Plvp 1 Plvp 1 ACab 2 ACf 5 COse 10 SPn 6 COse 3 COse 4 COse 8 COse 9 SPn 3 COse 4 COse 4 COse 2 ILgb 3 LIbe 3 SPn 4 COse 7 ILgb 10 SPn 11 CEam 3 ROpa 3 COse 3 COse 4 ROpa 5 ROpa 10 ROpa 14 CAV 6 CAV 3 COse 1 ACf 4 CEam 6 SPn 3 LIbe 3 LIbe 6 CEam 7 ILgb 9 ILgb 7 DIlo 2 ILgb 2 ILgb 2 CEam 2 ILgb 2 LIbe 9 CEam 5 COse 5 LIbe 6 COse 8 CEam 6 CEam 1 PIvp Scale: 1:10 PLANTING PLAN1 00 10'20' DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 10 / 2 7 / 2 0 2 1 4 : 5 9 : 5 5 P M 10/29/21 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 JVB/LEB REVISION SCHEDULE NAME DATE L401 PLANTING PLAN KEY MATERIAL DETAIL TREE PLANTING SHRUB PLANTING CONTRACT LIMIT LINE PROPERTY LINE GENERAL SHEET NOTES - PLANTING PLANTING NOTES: 1.ALL PLANTING BEDS TO BE PREPARED AS SPECIFIED: SHRUB BEDS TO BE PREPARED IN THEIR ENTIRETY WITH PLANTING SOIL MIX. TREE PITS TO BE DUG TO DEPTH OF ROOTBALL BY 3X THE DIAMETER. 2.AFTER BEDS ARE PREPARED, THE LANDSCAPE CONTRACTOR IS TO LOCATE TREES, SHRUBS AND VINES AS SHOWN ON PLANS. TREE, SHRUB AND PERENNIAL LOCATIONS ARE TO BE APPROVED BY LANDSCAPE ARCHITECT BEFORE THEY ARE PLANTED. 3.NO PLANTS ARE TO BE PLANTED UNDER ROOF OVERHANGS OR CANOPIES. 4.ANY AND ALL AREAS DISTURBED BY CONSTRUCTION THAT ARE NOT SHOWN AS PAVED OR PLANTED BED ARE TO BE SEEDED AS TURF, UNLESS INDICATED OTHERWISE. PREPARE AND SEED TURF AS PER SPECIFICATIONS AND DETAILS. 5.ALL TREES AND PLANTS TO COMPLY WITH APPLICABLE REQUIREMENTS OF ANSI 260.1 "AMERICAN STANDARD FOR NURSERY STOCK". 6.MAINTAIN AND WARRANTY ALL LIVING PLANT MATERIAL AS PER SPECIFICATIONS. 7.ANY EXISTING TREES DAMAGED BY CONSTRUCTION ACTIVITIES TO BE PRUNED BY A QUALIFIED ARBORIST OR REPLACED IN KIND AT NO COST TO THE OWNER AS DETERMINED BY LEVEL OF DAMAGE AND LANDSCAPE ARCHITECT RECOMMENDATION 8.HAND DIG AND PLANT SHRUBS AND PERENNIALS WITHIN CANOPY OF EXISTING TREES. PROTECT ROOTS OF EXISTING TREES DURING INSTALLATION. 9.TURF IS TO BE ESTABLISHED EARLY ENOUGH TO ACHIEVE 80% COVERAGE BY THE END OF THE GROWING SEASON. 10.ALL NON PLANTING AREAS DISTURBED BY CONSTRUCTION TO BE SEEDED C1 L501 C2 L501 C6 L501 THIS PAGE INTENTIONALLY LEFT BLANK Scale: 1:10 MULCH AND SOILS PLAN1 00 10'20' DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 10 / 2 7 / 2 0 2 1 4 : 5 9 : 5 5 P M 10/29/21 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 JVB/LEB REVISION SCHEDULE NAME DATE L402 MULCH AND SOILS PLAN KEY MATERIAL DETAIL BIORETENTION SOIL TREE AND SHRUB PLANTING SOIL GRAVEL MULCH CONTRACT LIMIT LINE PROPERTY LINE GENERAL SHEET NOTES - SOILS PLANTING NOTES: 1.ALL PLANTING BEDS TO BE PREPARED AS SPECIFIED: SHRUB BEDS TO BE PREPARED IN THEIR ENTIRETY WITH PLANTING SOIL MIX. TREE PITS TO BE DUG TO DEPTH OF ROOTBALL BY 3X THE DIAMETER. 2.AFTER BEDS ARE PREPARED, THE LANDSCAPE CONTRACTOR IS TO LOCATE TREES, SHRUBS AND VINES AS SHOWN ON PLANS. TREE, SHRUB AND PERENNIAL LOCATIONS ARE TO BE APPROVED BY LANDSCAPE ARCHITECT BEFORE THEY ARE PLANTED. 3.NO PLANTS ARE TO BE PLANTED UNDER ROOF OVERHANGS OR CANOPIES. 4.ANY AND ALL AREAS DISTURBED BY CONSTRUCTION THAT ARE NOT SHOWN AS PAVED OR PLANTED BED ARE TO BE SEEDED AS TURF, UNLESS INDICATED OTHERWISE. PREPARE AND SEED TURF AS PER SPECIFICATIONS AND DETAILS. 5.ALL TREES AND PLANTS TO COMPLY WITH APPLICABLE REQUIREMENTS OF ANSI 260.1 "AMERICAN STANDARD FOR NURSERY STOCK". 6.MAINTAIN AND WARRANTY ALL LIVING PLANT MATERIAL AS PER SPECIFICATIONS. 7.ANY EXISTING TREES DAMAGED BY CONSTRUCTION ACTIVITIES TO BE PRUNED BY A QUALIFIED ARBORIST OR REPLACED IN KIND AT NO COST TO THE OWNER AS DETERMINED BY LEVEL OF DAMAGE AND LANDSCAPE ARCHITECT RECOMMENDATION 8.HAND DIG AND PLANT SHRUBS AND PERENNIALS WITHIN CANOPY OF EXISTING TREES. PROTECT ROOTS OF EXISTING TREES DURING INSTALLATION. 9.TURF IS TO BE ESTABLISHED EARLY ENOUGH TO ACHIEVE 80% COVERAGE BY THE END OF THE GROWING SEASON. 10.ALL NON PLANTING AREAS DISTURBED BY CONSTRUCTION TO BE SEEDED THIS PAGE INTENTIONALLY LEFT BLANK NYSDOT TYPE 7 TOP COURSE NYSDOT TYPE 3 BINDER COURSE SUBBASE SHOULDER TO EXTEND 12" BEYOND EDGE OF PAVEMENT COMPACTED SUBGRADE 112" 1' - 3 " 2" SEPARATION FABRIC TO WRAP UNDER ASPHALT 2'-0" WRAP TAMP EDGES 212" NYSDOT TYPE 1 BASE COURSE CONCRETE PAVING 6 X 6 X W2.9 X W 2.9 WELDED WIRE MESH, FLAT SHEETS SET ON CHAIRS SUBBASE COMPACTED SUBGRADE NOTES: 1.2" MINIMUM CONCRETE COVERAGE ON MESH AND TIES WIDTH AS SHOWN ON PLAN CROSS SLOPE AS SHOWN ON GRADING PLAN 5" 8" 212" 2" EXPANSION JOINT (EJ) AND JOINT FILLER 1/2" x 24" EPOXY COATED, W/ PLASTIC SLEEVE AT 18" O.C. TJ EJ & CJ CONC WALK - DEPTH VARIES SUBBASE COMPACTED SUBGRADE 1" DEEP TOOL JOINT (TJ) W/ 14" RADIUS NOTES: 1.NO SAW CUT JOINTS ALLOWED. HAND TOOL JOINTS. 6'-0" TYP 6'-0" PITCH 1:12 DETECTABLE WARNINGS - SEE SPECS. NOTES: 1.SEE LAYOUT PLAN FOR LOCATION AND DIMENSION OF CURB RAMPS 2.GRADE CHANGES TO BE SMOOTH AND EVENLY PITCHED. 6' - 0 " T Y P PITCH 1:12 SEE LAYOUT PLAN 121 ISOMETRIC VIEW N.T.S. PLAN 6' TYP. 6' TYP. 1 12 6' TYP. 6" T Y P SEE LAYOUT PLAN HANDICAP PAVEMENT MARKING TRAFFIC WHITE 4" WIDE PAINT LINE, TYP. CURB FACE TRAFFIC WHITE 4" WIDE PAINT LINE, TYP. NOTES: 1.CONTRACTOR SHALL PROVIDE ANY NEW OR ADDITIONAL SIGNS NEEDED TO MEET ADA PARKING CODE REQUIREMENTS. 2.POSTS AND MOUNTING HARDWARE SHALL BE GALVANIZED TAMPER RESISTANT BOLTS, LENGTH AS NECESSARY. TRAFFIC BLUE PAINT 4' - 0 " NEW YORK STATE ACCESSIBLE ICON TRAFFIC WHITE PAINT 4'-0" WHEEL STOP 3' - 0 " TY P . 12" 7' - 0 " C L E A R MI N . , T Y P . 2" GALVANIZED U-CHANNEL POST WITH BREAKAWAY BASE ADJACENT PAVEMENT 2500 PSI CONC. SONO TUBE RESERVEDPARKING TYPE A TYPE B IN AISLE RESERVEDPARKING NOTES: 1.PLANT AT SAME DEPTH AS PREVIOUSLY PLANTED IN NURSERY OR CONTAINER 2.PROVIDE COMPACTED BASE UNDER ROOT BALL ONLY TO PREVENT SETTLING SHREDDED BARK MULCH, EXTENT OF BEDLINE: ·4" (100mm) FOR SHRUBS ·3" (75mm) FOR PERENNIALS AND BULBS UNTIE AND ROLL BACK BURLAP FROM MIN. 1/3 OF ROOT BALL. SYNTHETIC WRAP IS UNACCEPTABLE. CUT WIRE BASKETS AND REMOVE. SPECIFIED PLANTING MIX SPADED BED EDGE COMPACTED BASE 2' - 0 " MI N . PLANT SHALL BE SET AT OR SLIGHTLY ABOVE THE ESTABLISHED FINISH GRADE 4" SPECIFIED SHREDDED BARK MULCH UNTIE AND ROLL BACK BURLAP FROM MIN. 1/3 OF ROOT BALL. SYNTHETIC WRAP IS UNACCEPTABLE. CUT WIRE BASKETS AND REMOVE. SPECIFIED PLANTING MIX SCARIFY SIDES AND BOTTOM OF TREE PIT TO PREVENT GLAZING OF SUBGRADE. SET TREE DIRECTLY ON SUBGRADE TO PREVENT SETTLING. 3X WIDTH OF ROOT BALL 6" M I N 6" TURF SOIL MIX, ROLL TO COMPACT TO 85% PROCTOR DENSITY 1'-0" MIN. CLEAN FILL OR DEEP RIPPED SUBSOIL AMENDED WITH 9.25 CY OF COMPOST PER 1000 SF 1' - 0 " M I N . UNDISTURBED SUBGRADE 4" NOTES: 1.LAWN RESTORATION WORK TO COMPLY WITH REQUIRMENTS PER "NYS DEC - STORMWATER MANAGEMENT DESIGN MANUAL - AUGUST 2010" AS WELL AS "NYS DEC DEEP RIPPING AND COMPACTION - APRIL 2008" 3" COMPOST TILL (DEEP RIP) INTO SUBSOIL 3" LAWN SEED OR HYDROMULCH PLACE EROSION CONTROL BLANKET ON SLOPES GREATER THAN 1V:3H NOTES: 1.DO NOT STORE EQUIPMENT OR MATERIALS WITHIN BIO-INFILTRATION BASIN WIDTH VARIES SPECIFIED BIO-RETENTION SOIL MIXTURE GEOTEXTILE FILTER FABRIC SEE CIVIL DWGS FOR UNDER DRAIN HEADER, LATERAL, AND PERFORATED PVC PIPE HEADER, CONNECTIONS AND DETAILS PLANTINGS IN BIO-RETENTION BEDS MULCH LAYER 3X WIDTH OF ROOT BALL FOR TREES AND SHRUBS BED TREES AND SHRUBS INSTALLED IN BIO-RETENTION FACILITIES IN SPECIFIED PLANTING SOIL MIXTURE 12" - 15" DRAINAGE STONE NOTES: 1.RADIUS CURBING SHALL BE USED ON ALL RADII LESS THAN 100 FEET. 6" 1' - 4 " 3" 5" 9" 6"6" ELEVATION ADJACENT PAVING ADJACENT PAVEMENT OR LAWN. SEE LAYOUT PLAN GRANITE CURBING 5"X16", SAWN TOP SPLIT FACE (4' MINIMUM LENGTH) LEAN CONCRETE CONTINUOUS FULL LENGTH OF CURB DRY CONCRETE MIX AS CURB BEDDING COMPACTED NYSDOT TYPE 4 SUBBASE (ITEM 304.14) UNDISTURBED EARTH 2" LIMESTONE SCREENINGS COMPACTED COMPACTED SUBBASE COMPACTED SUBGRADE WIDTH AS SHOWN ON PLAN CROSS SLOPE AS SHOWN ON GRADING PLAN 2" 6" SEPARATION FABRIC 1'-0" TAMP EDGES - FILL & FEATHER TO MEET EXISTING GRADE DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com DATE: PROJECT: OTHER: DRAWN BY: 10 / 2 7 / 2 0 2 1 4 : 5 9 : 5 5 P M 10/29/21 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 JVB/LEB REVISION SCHEDULE NAME DATE L501 SITE DETAILS 1" = 1'-0" HEAVY DUTY ASPHALT PAVINGA91" = 1'-0" MEDIUM DUTY CONCRETE WALKWAYA71" = 1'-0" CONCRETE JOINTSA5 1/4" = 1'-0" ADA CURB RAMPE91/4" = 1'-0" ADA PAVEMENT MARKINGSE71/4" = 1'-0" ADA PARKING SIGNAGEE5 1/4" = 1'-0" SHRUB PLANTINGC21/4" = 1'-0" TREE PLANTINGC1 1" = 1'-0" LAWN ESTABLISHMENT WITH SOIL DECOMPACTIONC91/2" = 1'-0" PLANT INSTALLATION IN BIORETENTION BEDC6 1" = 1'-0" GRANITE CURBA21" = 1'-0" LIMESTONE DUST PATHWAYA1 THIS PAGE INTENTIONALLY LEFT BLANK A201C6 A201 F3 A201 A3 A201 C3 A1 A301 A1 A301 A251 A1 A4 A3A6 100 VESTIBULE 101 LOBBY 112 CONFERENCE ROOM 111 SW&CO OPEN OFFICE 103 LEASABLE SPACE 108 OFFICE 109 OFFICE 110 OFFICE SW&CODATA 3149 sf KITCHENETTE 1A 1A 1A EWS 2 1B 2 2 EWS 4 EWS 4 EWS 4 1A 1A 1A EWS 4 EWS 4 1A 1A 1B 1A EWS 4 EWS 4 EWS 4 EWS4 EWS4 EWS 4 EWS 4 1B 1A1A 1A 105 TOILET 106 TOILET 113 JC/STOR 104 STOR/DATA 2 1A 1A 107 MECHANICAL/SW&CO DATA A1 A311 A251 B4 D7 B1B7 A251 D4 D2 D1 D5 1A EWS 1 A7 A301 A7 A301 A9 A311 A6 A311 EWS 4 FUTURE DRINKING FOUNTAIN FUTURE SINK FUTURE TOILET EXPOSED GLULAM COLUMN (TYP) FRAMING ONLY, NO GYP FRAMING ONLY, NO GYP A4 A311 EWS 2 1B1B1B EWS 2 111C 110 109 108 107 111B 111A 111 103 101A 101B 100 2 103B 103A 103C EWS 1 EWS 1 EWS 1 EWS 2 EWS 1 EWS 1 EWS 1 EWS 1 34' - 7 31/32"7' - 4 1/32"7' - 3"62' - 0"37 ' - 3 3 / 3 2 " 28' - 7 1/8"3 1/2"14' - 11 3/8"3 1/2"5' - 8" 11 ' - 6 1 1 / 1 6 " 6' - 1 1 / 2 " 3 1 / 2 " 7' - 7 " 3 1 / 2 " 5' - 0 " 3 1 / 2 " 7' - 7 1 3 / 3 2 " 9' - 8 1 5 / 1 6 " 3 1 / 2 " 10' - 10 7/16"3 1/2"11' - 8 3/32"3 1/2"11' - 6 15/32"3 1/2"14' - 10 17/32" 3/16" = 1'-0"A1 FLOOR PLAN DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. DATE: PROJECT: OTHER: DRAWN BY: 1/6/2022 5:15:18 PM A101 FIRST FLOOR PLAN Issue Date 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 EMA GENERAL ARCHITECTURAL NOTES KEYED CONSTRUCTION NOTES 1 CONTRACTOR SHALL PROVIDE FIRE RETARDANT WOOD BLOCKING AT ALL FLOOR,WALL, AND CEILING MOUNTED EQUIPMENT, MILLWORK, AND ACCESSORIES PROVIDED UNDER THIS CONTRACT AND EQUIPMENT TO BE PROVIDED BY THE OWNER. 2 CONTRACTOR SHALL PROVIDE BRACING WHERE REQUIRED TO SUPPORT OR STABILIZE ALL NON-STRUCTURAL FRAMING. 3 PROVIDE ACCESS PANELS IN WALLS AND CEILINGS AS REQUIRED TO OBTAINCONVENIENT MAINTENANCE ACCESS TO ALL VALVES, DAMPERS, CONCEALEDJUNCTION BOXES, AND OTHER EQUIPMENT REQUIRING ADJUSTMENT, SERVICE, OR MAINTENANCE. PROVIDE PROPOSED LOCATION AND SIZE OF ALL ACCESS PANELS FOR REVIEW AND APPROVAL BY ARCHITECT PRIOR TO INSTALLATION. 4 PROVIDE EXPANSION JOINT COVERS/ASSEMBLIES AT ALL INTERIOR AND EXTERIOREXPANSION JOINTS. 5 PROVIDE FIRE RATED ACCESSORIES AT ALL FIRE RATED PARTITIONS. 6 REFER TO CODE CONFORMANCE DRAWING FOR FIRE EXTINGUISHER CABINET LOCATIONS. REVISION SCHEDULE NAME DATE THIS PAGE INTENTIONALLY LEFT BLANK A1 A311 A9 A311 A6 A311 A4 A311 CONCEALED GUTTER SYSTEM STANDING SEAM METAL PANEL ROOF, BLACK DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. DATE: PROJECT: OTHER: DRAWN BY: 1/6/2022 5:15:19 PM A105 ROOF PLAN Issue Date 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 EMA 3/16" = 1'-0"1 ROOF PLAN REVISION SCHEDULE NAME DATE THIS PAGE INTENTIONALLY LEFT BLANK FIRST FLOOR 100' -0" STANDING SEAM METAL ROOF STANDING SEAM METAL WALL PANEL ROOF PLAN 111' -0" FIRST FLOOR 100' -0" GLULAM BEAM VERTICAL WOOD PANELING BOARD FORMED CONCRETE PANELING STOREFRONT, EFCO 403X WITH SHADOW BOX ROOF PLAN 111' -0" 15 ' - 5 1 3 / 1 6 " FIRST FLOOR 100' -0" GLULAM BEAM VERTICAL WOOD PANELING BOARD FORMED CONCRETE PANELING STOREFRONT, EFCO 403X WITH SHADOW BOX ROOF PLAN 111' -0" FIRST FLOOR 100' -0" METAL FASCIA VERTICAL WOOD PANELING BOARD FORMED CONCRETE PANELING STOREFRONT, EFCO 403X WITH SHADOW BOX ROOF PLAN 111' -0" DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. DATE: PROJECT: OTHER: DRAWN BY: 1/12/2022 4:08:19 PM A201 EXTERIOR ELEVATIONS Issue Date 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 EMA 3/16" = 1'-0"A3 EXTERIOR ELEVATION - SOUTH 3/16" = 1'-0"F3 EXTERIOR ELEVATION - NORTH 3/16" = 1'-0"C6 EXTERIOR ELEVATION - EAST 3/16" = 1'-0"C3 EXTERIOR ELEVATION - WEST REVISION SCHEDULE NAME DATE THIS PAGE INTENTIONALLY LEFT BLANK FIRST FLOOR 100' -0" 103 LEASABLE SPACE 113 JC/STOR 104 STOR/DATA 111 SW&CO OPEN OFFICE FIRST FLOOR 100' -0" 111 SW&CO OPEN OFFICE 109 OFFICE DESIGN DEVELOPMENT NOT FOR CONSTRUCTION OR BIDDING A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 619 W. State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. DATE: PROJECT: OTHER: DRAWN BY: 1/6/2022 5:15:25 PM A301 BUILDING SECTIONS Issue Date 40 8 E a s t U p l a n d R o a d I t h a c a N e w Y o r k 1 4 8 5 0 40 8 U p l a n d R o a d L L C 40 8 U p l a n d R o a d O f f i c e B u i l d i n g 20008 EMA 3/16" = 1'-0"A1 BUILDING SECTION EAST/WEST 3/16" = 1'-0"A7 BUILDING SECTION NORTH/SOUTH REVISION SCHEDULE NAME DATE THIS PAGE INTENTIONALLY LEFT BLANK